• Title/Summary/Keyword: Disposal area

Search Result 332, Processing Time 0.027 seconds

Preliminary results of groundwater flow simulation for high level radioactive disposal in Yu-seong area

  • Park kyung-woo;Cho sung-il;Kim chun-soo;Kim kyung-su;Lee kang-keun
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.253-257
    • /
    • 2005
  • This research aims to demonstrate the regional and site scale groundwater flow simulation for the high level radioactive disposal research site in Yu-seong. We used the Modflow by a finite difference method for groundwater flow simulation, and Modpath module in Modflow package for particle tracking simulation. The range of numerical domain for regional groundwater flow model is $16.32km{\times}20.16km$. And, the depth of numerical domain was expanded to 6,000m. The area of numerical domain for the site scale groundwater flow simulation is $1.6km{\times}1.6km$. Since 2005, the underground research tunnel(URT) is being constructed at KAERI(Korea Atomic Energy Research Institute) site. In the site scale groundwater flow model, the groundwater flow around the KAERI site is simulated. And the change of groundwater level with tunnel excavation is also predicted.

  • PDF

A Study on Unit Treatment Cost of Sewage Disposal Plant in the Service Area under Highway (생물학적 처리시설의 처리비 원단위 산정에 관한 연구 -고속도로 휴게소를 중심으로-)

  • 장철현;박상우;홍태석
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.537-541
    • /
    • 2002
  • This study aimed to obtain the relative formula with the unit treatment cost according to the treatment of a sewage plant in the service area under highway. The following results were obtained. The correlative formula connected to amount of sewage(Q)generation was as follows ; between an annual amount of sale(C) showed Q=19.113$.$C$\^$0.9294/, and between the number of users(P) showed Q=2${\times}$10$\^$-8/ $.$P$^2$- 0.0298$.$P + 75,666. The correlative formula connected to the treatment cost was as follows , according to the amount of sewage generation showed S= 3${\times}$10$\^$-6/$.$Q 0-0.2266$.$Q+29,895, according to the elimination of BOD(E) showed S=6${\times}$10$\^$-5/$.$E$^2$-0.6717$.$E + 27,744, according to the annual amount of sale showed S=0.0005 C$^2$-4.8013$.$C + 35,118, with the number, of persons(P) using the service area showed S= 2${\times}$10$\^$-8/ $.$P$^2$- 0.046$.$P + 48,803.

Concentration of metallic elements in surface sediments at a waste disposal site in the Yellow Sea (황해 폐기물 투기해역(서해병) 표층 퇴적물의 금속원소 분포)

  • Koh, Hyuk-Joon;Choi, Young-Chan;Park, Sung-Eun;Cha, Hyung-Kee;Chang, Dae-Soo;Lee, Chung-Il;Yoon, Han-Sam
    • Journal of Environmental Science International
    • /
    • v.22 no.7
    • /
    • pp.787-799
    • /
    • 2013
  • The aim of this study was to investigate the accumulation of metallic elements and the control effect of marine pollution caused by ocean dumping in the sediments at a waste disposal area in the Yellow Sea. In July 2009, concentrations of organic matter and metallic elements (Al, Fe, As, Cd, Cr, Co, Hg, Ni, Mn, Pb, and Zn) were measured in surface sediments at the site. The ignition loss (IL) in the surface sediments showed a mean value of 15.4%, about 1.5 times higher than the mean value of the sediments in the coastal areas of Korea. The chemical oxygen demand (COD) at some disposal sites exceeded 20 mg $O_2/g{\cdot}dry$, which signifies the initial concentration of marine sediment pollutants in Japan. The disposal sites contain higher concentrations of Cr, Cu and Zn than the sediments of bays and estuaries that might be contaminated. The magnitude of both metal enrichment factors (EF) and adverse biological effects suggest that pollution with Cr and Ni occurred due to the dumping of waste in the study area. In addition, the geoaccumulation index (Igeo) showed that the surface sediments were moderately contaminated. By the mid-2000s, when the amount of waste dumped at this site was the highest, the concentration of metallic elements was higher than ever recorded. On the other hand, in 2008-09, the need for environmental management was relatively low compare with the peak. As a result, the quality of marine sediment has been enhanced, considering the effect of waste reduction and natural dilution in the disposal area.

A Survey on the Use of Deep-fat-fried Foods and Treatment of the Used Oils at Home in Chonbuk Area (전북지역의 가정에서 튀김조리 이용과 사용된 튀김유의 관리실태)

  • 윤계순
    • Korean journal of food and cookery science
    • /
    • v.17 no.6
    • /
    • pp.533-541
    • /
    • 2001
  • This research was carried out to obtain the information about the use of deep-fat-fried foods and treatment of oils used for deep-fat-frying at home. Data were obtained through questionnaires from 442 housewives in Chonbuk area. The frequency of taking deep-fat-fried foods was affected by ages and residential area. Average score for the preference of deep-fat-fried foods was 3.60 in the 5 point scale. Fifty three percent of the respondents prepared deep-fat-fried foods by themselves at home. The oil most commonly used for deep-fat-frying was soybean oil followed by com oil. Proper frying temperature was determined by dropping salt or food coating materials into the oil. Oil color was used as a parameter for determining the life of frying oils by 81.2% of the respondents. Most of the respondents appealed to use oils one more time after filtering. For the disposal of used frying oil, 65.7% of the respondents used some kinds of absorbing papers; 16.1% made soaps and 10.7% discarded into a sink. According to correlation analysis, the frequency of taking deep-fat-fried food had positive relationships with housewives's health status, preference for foods prepared with oil and fats and family's preference for deep-fat-fried foods.

  • PDF

The Estimation of Pollution Loads in First-flush Overflows with Various Rainfall and Regional Characteristics (강우 및 지역특성별 초기우수월류에 의한 오염부하 기여도 평가)

  • Kim, Hongtae;Shin, Dongseok;Kim, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.622-631
    • /
    • 2014
  • The purpose of this research was to find a proper disposal rainfall extent to improve water quality. SWMM was applied to select catchment area and tested first flush load and rainfall extent. BOD 40mg/L was selected to dispose the first flush and sewer overflow with the same as the criteria of Sewerage Act. Design rainfall, BOD load ratio of first flush sewer overflow, and the ratio of disposal flow were analyzed under various rainfall distribution. BOD load and design rainfall to treat overflow in situation of first flush extent with 4.3~17.4% were 56~87% and 3.8~6.8 mm/day, respectively. In urban area, first flush loads were not correspond to land activities, but tend to increase with increasing rainfall amount and drainage area. The more the distribution of rainfall is similar to Huff-frontal or central distribution of rainfall, the more increase the first flush loads.

Research for Construction of Landfills at Sea Disposal of Wastes to be Reclaimed in the Metropolitan Area in the Future (폐기물 해상매립장의 도입방안에 관한 연구 - 장래 수도권 지역의 매립폐기물 처리를 중심으로 -)

  • 정공일;김영수
    • Journal of Korea Port Economic Association
    • /
    • v.17 no.1
    • /
    • pp.159-180
    • /
    • 2001
  • The quantity of waste has been increased due to the increase in population and consumption after industrialization. Accordingly it caused the urban environmental problems, the lack of landfill and the pollution around the landfill. Thus, it is necessary to research the adequate alternative in the long-term. In case of Japan, areas and quantities of landfills at sea are more great than those of landfills in land. And investigating our condition, landfills of the metropolitan area in land are to be fully filled with wastes up to 2020 and be closed. In this research, construction of landfill sites at sea is suggested as the alternative waste disposal method and it is suggested that in our country, the suitable landfill sites of the metropolitan area are the regions around Jangbong-do Island and Muei-do Island. It is expected that the best way to transport wastes is to transport through Kyungin canal from the middle collection center to the lower Han River. Rough cost for construction of landfill at sea, if it is used for 50 years, is expected to be 2 trillion won and total time to construct the landfill is expected to be 10 years. Many studies concerning to this research proposal are to be performed so that construction of landfills familiar to environment are to be accomplished.

  • PDF

A STUDY OF THE PRESSURE SOLUTION AND DEFORMATION OF QUARTZ CRYSTALS AT HIGH pH AND UNDER HIGH STRESS

  • Choi, Jung-Hae;Seo, Yong-Seok;Chae, Byung-Gon
    • Nuclear Engineering and Technology
    • /
    • v.45 no.1
    • /
    • pp.53-60
    • /
    • 2013
  • Bentonite is generally used as a buffer material in high-level radioactive waste disposal facilities and consists of 50% quartz by weight. Quartz strongly affects the behavior of bentonite over very long periods. For this reason, quartz dissolution experiment was performed under high-pressure and high-alkalinity conditions based on the conditions found in a high-level radioactive waste disposal facility located deep underground. In this study, two quartz dissolution experiments were conducted on 1) quartz beads under low-pressure and high-alkalinity conditions and 2) a single quartz crystal under high-pressure and high-alkalinity conditions. Following the experiments, a confocal laser scanning microscope (CLSM) was used to observe the surfaces of experimental samples. Numerical analyses using the finite element method (FEM) were also performed to quantify the deformation of contact area. Quartz dissolution was observed in both experiments. This deformation was due to a concentrated compressive stress field, as indicated by the quartz deformation of the contact area through the FEM analysis. According to the numerical results, a high compressive stress field acted upon the neighboring contact area, which showed a rapid dissolution rate compared to other areas of the sample.

Landscape Design for Integrated Disposal Treatment Facility in Southern Region (남부 광역 생활폐기물 종합처리시설 조경설계)

  • 민권식
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.1
    • /
    • pp.11-22
    • /
    • 2003
  • This landscape design proposal was presented to a design competition for the Incheon-city Southern Region Integrated Disposal Treatment Facility. The site is located in Dongchun-dong, Yeonsu-gu, Incheon. The main design concepts are as follows: First, considering connection of the site with surrounding water, inner sea is designed as an environmentally friendly place and as a leisure-sports theme park in which several sports facilities and relaxing places are arranged. It is also designed for everyone: people of all ages, disabled, workers, visitors and local residents. The design was processed on the basis of survey, analysis of surrounding competing facilities and SWOT analysis. Second, the ecological planting model was developed by analyzing the natural vegetation map in the surrounding area and planted vegetation types in the seaside reclamation area. The model was then applied to the ecological community, park area and roadside trees, so as to harmonize with the local habitat. Third, the project is intended to launch private capital for managing the sports park and golf course. This will enable a entrepreneur to make flexible plans for golf training field that is expected to yield a good financial return. It is expected that this design would serve the local residents as a symbolic, environmentally friendly leisure-sports theme park.

A Numerical Analysis to Estimate Disposal Spacing and Rock Mass Condition for High Efficiency Repository Based on Temperature Criteria of Bentonite Buffer (벤토나이트 완충재 설계 기준 온도에 따른 고효율 처분시스템 처분 간격 및 암반 조건 산정을 위한 수치해석적 연구)

  • Kim, Kwang-Il;Lee, Changsoo;Kim, Jin-Seop;Cho, Dongkeun
    • Tunnel and Underground Space
    • /
    • v.31 no.4
    • /
    • pp.289-308
    • /
    • 2021
  • This study conducts coupled thermo-hydro-mechanical numerical modeling to investigate the maximum temperature and conditions for securing mechanical stability of the high-level radioactive waste repository when temperature criteria of bentonite buffer are 100℃ and 125℃, respectively. In case of temperature criterion of buffer as 100℃, the maximum temperatures at the interface between canister and buffer are calculated to be 99.4℃ and 99.8℃, respectively for a case with disposal tunnel spacing of 40 m and deposition hole spacing of 5.5 m and for the other case with disposal tunnel spacing of 30 m and deposition hole spacing of 6.5 m. In case of temperature criterion of buffer as 125℃, spacings of disposal tunnel and deposition hole could be decreased to 30 m and 4.5 m, respectively, which reduces the disposal area up to 55% compared to the disposal area of KRS+. According to analysis of mechanical stability for various disposal spacings, RMR of rock mass for KRS+ should be larger than 72.4 which belongs to good rock in RMR classification to prevent failure of rock mass. As disposal spacing is decreased, required RMR of rock mass is increased. In order to prevent failure of rock mass for a case with disposal tunnel spacing of 30 m and deposition hole spacing of 4.5 m, RMR larger than 87.3 is needed. However, mechanical stability of the repository is secured for all cases with RMR over 75 considering the enhancement of rock strength due to confining stress induced by swelling of the bentonite buffer and backfill.

A Study on the Space Composition for Department of Kidney Dialysis in Regional Public Hospital(1) (지역거점 공공병원의 인공신장부 공간구성에 관한 연구(1))

  • Chai, Choul Gyun;Park, Kyeong Hyeon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.2
    • /
    • pp.31-38
    • /
    • 2022
  • Purpose: This study presents the results of the analysis on space utilization of kidney dialysis units in regional public hospitals, which plays a key role in local public medical services. The result aims to achieve safety from infection, allow comfort for the dialysis environment, and stability for medical support. The purpose of this study is to present fundamental data for architectural plans for the kidney dialysis unit, as well as to alleviate potential infectious diseases such as COVID-19. Methods: For research purposes, the investigation and analysis of space utilization were based on architectural floor plans, research papers and literature, related legal systems, and public statistics. Of the main 35 regional public hospitals, in regards to data accessibility, 15 facilities were selected to conduct the survey and analysis for the objective. Results: The space composition by area research results of kidney dialysis units in public hospitals are as follows: Firstly, most targets do not have required rooms in the access and support area, except for the hemodialysis beds in the treatment section. Secondly, the access area requires necessary room and space design that took into consideration of convenience and accessibility for patients. Thirdly, in regards to infection prevention and control, proper circulation and room plan is essential for storage and disposal of contaminated products and linen after use. For the treatment area, the arrangement plan needs to establish a visual connection between the isolation room, the nursing station, and the bed area. Additionally, consideration of circulation in the preparation, treatment, observation, examination, and all other rooms in the facility is required. Lastly, for the support area, the room is designed to consider adequate working and meeting spaces for the medical staff, consultation space for patients or guardians, separate storage and disposal of clean and contaminated items, and the storage of various equipment for dialysis. Implications: In preparation for the increase in chronic kidney failure patients and the spread of infectious diseases, such as COVID-19, the researched data demonstrates the basic guidelines for space composition of kidney dialysis units and the significant role of regional public hospitals.