• 제목/요약/키워드: Disposal Facility

검색결과 290건 처리시간 0.025초

Numerical Simulation of Rainfall Infiltration Into Disposal Cover of Performance Test Facility

  • Mijin Kwon;Seho Choi;Chunhyung Cho
    • 방사성폐기물학회지
    • /
    • 제22권2호
    • /
    • pp.185-199
    • /
    • 2024
  • Disposal cover as an engineered barrier of a near-surface disposal facility for low and very low-level radioactive waste is composed of a multi-layer to isolate radioactive waste from environmental influences for the long term. To acquire a realistic forecast for the post-closure period of the disposal facility, it is essential to carry out long-term experimental research in a similar condition to the actual disposal environment. Hence, a performance test facility of the disposal cover was constructed in Gyeongju low and intermediate level radioactive waste disposal center in 2022. The constructed performance test facility has differences from the material properties presented in the design. These differences are factors that affect the prevent rainfall infiltration, which is one of the important roles of the disposal cover. Therefore, in this study, a numerical simulation of rainfall infiltration into the performance test facility was performed for the designed case and the actual constructed case. To simulate the behavior of water infiltration, the FEFLOW software based on the finite element method is used. Through the analysis of numerical simulation results, it is confirmed that the hydraulic conductivity of the material constituting the multi-layer of the disposal cover greatly influences the amount of water infiltration.

방사성폐기물 표층처분시설 통합 모니터링 시스템 개발 (Development of an Integrated Monitoring System for the Low and Intermediate Level Radioactive Waste Near-surface Disposal Facility)

  • 최세호;강현구;권미진;하재철
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.359-367
    • /
    • 2023
  • In this study, the function and purpose of the disposal cover, which is an engineering barrier installed to isolate the disposal vault of the near-surface disposal facility for radioactive waste from natural/man-made intrusion, and the design details of the demonstration facility for performance verification were described. The Demonstration facility was designed in a partially divided form to secure the efficiency of measurement while being the same as the actual size of the surface disposal facility to be built in the Intermediate & low-level radioactive waste disposal site of the Korea Radioactive Waste Agency (KORAD). The instruments used for measurement consist of a multi-point thermometer, FDR (Frequency Domain Reflectometry) sensor, inclinometer, acoustic sensor, flow meter, and meteorological observer. It is used as input data for the monitoring system. The 3D monitoring system was composed of 5 layers using the e-government standard framework, and was developed based on 4 components: screen, control module, service module, and DBIO(DataBase Input Output) module, and connected them to system operation. The monitoring system can provide real-time information on physical changes in the demonstration facility through the collection, analysis, storage, and visualization processes.

Deployment of Radioactive Waste Disposal Facility with the Introduction of Nuclear Power Plants (NPP) in Kenya

  • Shadrack, A.;Kim, C.L.
    • Journal of Nuclear Fuel Cycle and Waste Technology
    • /
    • 제1권1호
    • /
    • pp.37-47
    • /
    • 2013
  • This paper describes basic plans for the development of a radioactive waste disposal facility with the introduction of Nuclear Power Plants (NPPs) for Kenya. The specific objective of this study was to estimate the total projected waste volumes of low- and intermediate-level radioactive waste (LILW) expected to be generated from the Kenyan nuclear power programme. The facility is expected to accommodate LILW to be generated from operation and decommissioning of nuclear power plants for a period of 50 years. An on-site storage capacity of 700 $m^3$ at nuclear power plant sites and a final disposal repository facility of more than 7,000 $m^3$ capacity were derived by considering Korean nuclear power programme radioactive waste generation data, including Kori, Hanbit, and APR 1400 nuclear reactor data. The repository program is best suited to be introduced roughly 10 years after reactor operation. This study is important as an initial implementation of a national LILW disposal program for Kenya and other newcomer countries interested in nuclear power technology.

방사성폐기물 처분장 부지감시 계획 (Site Monitoring and investigation plan for LILW disposal)

  • 백승종
    • 방사성폐기물학회지
    • /
    • 제6권4호
    • /
    • pp.369-385
    • /
    • 2008
  • 부지감시 및 조사의 목적은 운영 전, 운영중 및 폐쇄 후 단계에서 변화가 예상되는 주요 부지특성을 지속적으로 감시함으로써 방사성폐기물처분장의 성능평가 및 설계에 필요한 기초자료를 제공하는 것이다. 부지감시의 단계별 주요내용은 다음과 같다. 운영전 단계에는 부지의 적합성 평가 및 처분장 건설과 운영에 필요한 주요 부지특성을 감시하며, 운영 중 단계에는 안전하고 효율적인 운영과 환경에 미치는 영향을 판단하기 위하여 주변지역을 포함하여 주요 부지특성을 감시한다. 폐쇄 후 단계에는 처분장의 방사성 물질로 인한 영향을 사전에 예방하고, 처분장의 장기적 안전성을 위하여 필요한 주요 부지특성 항목을 감시한다.

  • PDF

Study on Rainfall Infiltration Into Vault of Near-surface Disposal Facility Based on Various Disposal Scenarios

  • Kwon, Mijin;Kang, Hyungoo;Cho, Chunhyung
    • 방사성폐기물학회지
    • /
    • 제19권4호
    • /
    • pp.503-515
    • /
    • 2021
  • In this study, rainfall infiltration in vault of the second near-surface disposal facility was evaluated on the basis of various disposal scenarios. A total of four different disposal scenarios were examined based on the locations of the radioactive waste containers. A numerical model was developed using the FEFLOW software and finite element method to simulate the behavior of infiltrated water in each disposal scenario. The effects of the disposal scenarios on the infiltrated water were evaluated by estimating the flux of the infiltrated water at the vault interfaces. For 300 years, the flux of infiltrated water flowing into the vault was estimated to be 1 mm/year or less for all scenario. The overall results suggest that when the engineered barriers are intact, the flux of infiltrated water cannot generate a sufficient pressure head to penetrate the vault. In addition, it is confirmed that the disposal scenarios have insignificant effects on the infiltrated water flowing into the vault.

중.저준위 방사성폐기물의 천층처분을 위한 인공방벽 실증시험시설의 건설 및 운전 경험 (Construction and Operational Experiences of Engineered Barrier Test Facility for Near Surface Disposal of LILW)

  • Jin-Beak Park;Se-Moon Park;Chang-Lak Kim
    • 방사성폐기물학회지
    • /
    • 제2권1호
    • /
    • pp.23-34
    • /
    • 2004
  • To validate the previous conceptual design of cover system, construction of the engineered barrier test facility is completed and the performance tests of the disposal cover system are conducted. The disposal test facility is composed of the multi-purpose working space, the six test cells and the disposal information space for the PR center. The dedicated detection system measures the water content, the temperature, the matric potential of each cover layer and the accumulated water volume of lateral drainage. Short-term experiments on the disposal cover layer using the artificial rainfall system are implemented. The sand drainage layer shows the satisfactory performance as intended in the design stage. The artificial rainfall does not affect the temperature of cover layers. It is investigated that high water infiltration of the artificial rainfall changes the matric potential in each cover layer. This facility is expected to increase the public information about the national radioactive waste disposal program and the effort for the safety of the planned disposal facility.

  • PDF

Evaluation of Exposure Dose and Working Hours for Near Surface Disposal Facility

  • Yeseul Cho;Hoseog Dho;Hyungoo Kang;Chunhyung Cho
    • 방사성폐기물학회지
    • /
    • 제20권4호
    • /
    • pp.511-521
    • /
    • 2022
  • Decommissioning of nuclear power plants generates a large amount of radioactive waste in a short period. Moreover, Radioactive waste has various forms including a large volumes of metal, concrete, and solid waste. The disposal of decommissioning waste using 200 L drums is inefficient in terms of economics, work efficiency, and radiation safety. Therefore, The Korea Radioactive Waste Agency is developing large containers for the packaging, transportation, and disposal of decommissioning waste. Assessing disposability considering the characteristics of the radioactive waste and facility, convenience of operation, and safety of workers is necessary. In this study, the exposure dose rate of workers during the disposal of new containers was evaluated using Monte Carlo N-Particle Transport code. Six normal and four abnormal scenarios were derived for the assessment of the dose rate in a near surface disposal facility operation. The results showed that the calculated dose rates in all normal scenarios were lower than the direct exposure dose limitation of workers in the safety analysis report. In abnormal scenarios, the work hours with dose rates below 20 mSv·y-1 were calculated. The results of this study will be useful in establishing the optimal radiation work conditions.

폐밀봉선원 처분시스템 예비 폐쇄후 안전성평가 (Preliminary Post-closure Safety Assessment of Disposal System for Disused Sealed Radioactive Source)

  • 이승희;김주열
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권4호
    • /
    • pp.33-48
    • /
    • 2017
  • An optimum disposal plan of disused sealed radioactive sources (DSRSs) should be established to ensure long-term disposal safety at the low- and intermediate-level radioactive waste (LILW) disposal facility in Gyeongju. In this study, an optimum disposal system was suggested and preliminary post-closure safety assessment was performed. The DSRSs disposal system was composed of a rock cavern and near surface disposal facilities at the Gyeongju LILW disposal facility. The assessment was conducted using GoldSim program, and probabilistic assessment and sensitivity analysis were implemented to evaluate the uncertainties in the input parameters of natural barriers. Deterministic and probabilistic calculations indicated that the maximum dose was below the regulatory limits ($0.1mSvyr^{-1}$ for the normal scenario, $1mSvyr^{-1}$ for the well scenario). It was concluded that the DSRSs disposal system would maintain environmental safety over a long-time. Moreover, the partition coefficient of Np in host rock, Darcy velocity in host rock, and density of the host rock were the most sensitive parameters in predicting exposure dose in the safety assessment.

Parametric Study for Structural Reinforcement Methods of Disposal Container for NPP Decommissioning Radioactive Waste

  • Hyungoo Kang;Hoseog Dho;Jongmin Lim;Yeseul Cho;Chunhyung Cho
    • 방사성폐기물학회지
    • /
    • 제21권3호
    • /
    • pp.329-345
    • /
    • 2023
  • This paper described a method for analyzing the structural performance of a metal container used for disposing radioactive waste generated during the decommissioning of a nuclear power plant, and numerical analysis results of a method for reinforcing the container. The containers to be analyzed were those that can be used in near-surface and landfill disposal facilities scheduled to be operated at the Gyeongju radioactive waste disposal facility. Structural reinforcement of the container was performed by lattice reinforcement, column reinforcement, and bottom plate reinforcement. Accordingly, a total of 14 reinforcement cases were modeled. The external force causing damage to the container was set equivalent to the impact of a 9-m fall, accounting for the height of the vault at the near-surface disposal facility. The reinforcement methods with a high contribution to the structural performance of the container were concluded to be lattice and column reinforcements.

극저준위 콘크리트, 금속 해체방폐물의 방사선적 특성을 고려한 매립형 처분시설 방사선작업자 예비 피폭선량 평가 (Preliminary Radiation Exposure Dose Evaluation for Workers of the Landfill Disposal Facility Considering the Radiological Characteristics of Very Low Level Concrete and Metal Decommissioning Wastes)

  • 도호석;조예슬;강현구;하재철
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.509-518
    • /
    • 2023
  • The Kori Unit 1 nuclear power plant, which is planned to be dismantled after permanent shutdown, is expected to generate a large amount of various types of radioactive waste during the dismantling process. For the disposal of Very-low-level waste, which is expected to account for the largest amount of generation, the Korea Radioactive waste Agency (KORAD) is in the process of detailed design to build a 3-phase landfill disposal facility in Gyeongju. In addition, a large container is being developed to efficiently dispose of metal and concrete waste, which are mainly generated as Very low-level waste of decommissioning. In this study, based on the design characteristics of the 3-phase landfill disposal facility and the large container under development, radiation exposure dose evaluation was performed considering the normal and accident scenarios of radiation workers during operation. The direct exposure dose evaluation of workers during normal operation was performed using the MCNP computer program, and the internal and external exposure dose evaluation due to damage to the decommissioning waste package during a drop accident was performed based on the evaluation method of ICRP. For the assumed scenario, the exposure dose of worker was calculated to determine whether the exposure dose standards in the domestic nuclear safety act were satisfied. As a result of the evaluation, it was confirmed that the result was quite low, and the result that satisfied the standard limit was confirmed, and the radiational disposal suitability for the 3-phase landfill disposal facility of the large container for dismantled radioactive waste, which is currently under development, was confirmed.