• 제목/요약/키워드: Displacement current

검색결과 791건 처리시간 0.03초

DLPC 인지질 단분자막의 변위전류 특성 (Displacement Current Characteristics of DLPC Lipid Monolayer)

  • 최용성;송진원;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.10-11
    • /
    • 2006
  • The azobenzene dendrimer is one of the dendrimeric macromolecules that include the azo-group exhibiting a photochromic character. Due to the presence of the charge transfer element of the azo-group and its rod-shaped structure, these compounds are expected to have potential interest in electronics and photoelectronics, especially in nonlinear optics. In the present paper, we give pressure stimulation to organic thin films and detect the induced displacement current. Functional photoisometrization organic molecular the photo-stimulus to organic monomolecular L films and LB films of dendrimer and SASH were performed. The SASH organic monolayer in case of pressure stimulus occurred that positive course but in case of the photo-stimulus compared positive and negative. It is assumed that generation forms of displacement current were measured when photo-stimulus for impression.

  • PDF

생체박막의 유전완화특성 (Dielectric Relaxation Characteristics of Biology Thin Film)

  • 송진원;조수영;이경섭;신훈규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.107-110
    • /
    • 2003
  • In this paper, We introduced that the method for determing the dielectric relaxation time $\tau$ of floating monolayers on water interface. Displacement current flowing across monolayers is analyzed using a rod-like molecular model. It is revealed that the dielectric relaxation time $\tau$of monolayers in the isotropic polar orientational phase is determined using a linear relationship between the monolayer compression speed $\alpha$ and the molecular area Am. here Displacement current gives a peak at A = Am. The dielectric relaxation time $\tau$ of organic monolayers was examined on the basis of the analysis developed here.

  • PDF

인지질 단분자막의 유전완화현상에 관한 연구 (A study on the Dielectric Relaxation Phenomena of phospolipid monolayers Film)

  • 조수영;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.431-434
    • /
    • 2003
  • In this paper, We introduced that the method for deforming the dielectric relaxation time $\tau$ of floating monolayers on water interface. Displacement current flowing across monolayer is analyzed using a rod-like molecular model. It is revealed that the dielectric relaxation time $\tau$ of monolayers in the isotropic polar orientational phase is determined using a linear relashionship between the monolayer compression speed a and the molecular area $A_m$. A displacement current gives a peak at A=$A_m$. The dielectric relaxation time $\tau$ of phospolipid monolayers was examined on the basis of the analysis developed here.

  • PDF

전류변성기 절대 평가 기술과 전류변성기 두 대를 이용한 전류 범위 확장 (Current Range Extension of Current Transformers by Using Absolute Evaluation Technique and Two Different Current Transformers)

  • 김윤형;한상길;정재갑;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.69-71
    • /
    • 2008
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios of the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

  • PDF

자기 변형 작동기를 이용한 진동 절연 시스템 (The vibration isolating system using a magnetostrictive actuator)

  • 정학근;박기환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.276-279
    • /
    • 1997
  • When a magnetostrictive material is exposed to a magnetic field, its geometry changes due to a magnetostrictive effect. The magnetostriction is analogous to the piezoeletricity. The displacement of the magnetostrictive material is proportional to the applied current while that of the piezoelectric material is proportional to the voltage. A magnetostrictive material generates large displacement and higher compressive force compared with a piezoeletric material. These advantages provide a good performance of a vibration isolation of a platform. In this work, it is applied to a driving actuator for vibration isolation of a platform. The properties of a magnetostrictive material are investigated in terms of hysteresis and displacement vs. applied current for a various preload. Modeling of the displacement of the vibration isolating actuator is performed as it behaves as a flow source. A sliding mode controller is designed to demonstrate the ability of the magnetostrictive actuator to reduce the vibration at the platform. The effectiveness of the proposed scheme is demonstrated through experimental works. The experimental results of the vibration of the platform axe presented in terms of time response and frequency response.

  • PDF

고속회전체의 진동 측정용 비접촉 광섬유 변위센서 개발 (Development of Optical Fiber Displacement Sensor for Non-contact Vibration Measurement in the High Speed Rotation System)

  • 이기석;홍준희;신우철
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.50-56
    • /
    • 2005
  • This paper is described a development of an optical fiber displacement sensor. The optical fiber sensor using an intensity modulated measures the displacement between target and sensor. A prototype sensor is composed of a transmitting part, a receiving part and a signal processing circuit. The experiment was conducted not only the sensor performance but also factors that affect intensity. The main performance of this sensor is resolution of 0.37um and the non-linearity $0.7\%$ FS and the dynamic bandwidth of about 6.3kHz. As a result of rotation test, the prototype sensor showed an equivalent performance to a commercial eddy current sensor.

생체박막의 전기특성에 관한 연구 (A Study on the Electrical Properties of Biology Thin)

  • 오재한;김동관;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.243-246
    • /
    • 1999
  • The displacement current measuring system used for detecting the dynamic behavior of monolayers at the air-water interface is described. It basically consists of a film balance, a pair of electrodes connected to each other through a sensitive ammeter. Here, one electrode is suspended in air and the other electrode is the water, With Maxwll-displacement-current-measuring method, the phase transitions of Poly(λ-benzyl- L-glutamate)(PBLG) on a water surface were detected, Displacement currents generated during the compression of monolayers of PBLG on the surface of water were investigated. As results, the displacement pick was generated when the area per molecule was about 15 $\AA$$^{2}$ in low pressure, and tit was generarted when the area per molecule about 27$\AA$$^{2}$ in high pressure.

  • PDF

전류변성기 비교기를 이용한 인덕터의 절대 평가 (Absolute Evaluation of Inductor Using Current Transformer Comparator)

  • 김윤형;정재갑;한상길;김한준;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.279-284
    • /
    • 2008
  • We have developed two absolute evaluation technology of inductor using current transformer (CT) comparator. One is the method that the reactance of inductor is obtained by analysing the equivalent circuit of CT with inductor connected to series at secondary terminal of CT. The other is the method that the reactance of inductor is obtained by comparing phase displacement of current flowing on inductor by using CT comparator. These technologies have the advantage to apply up to rated current and voltage of inductor. The method was applied to inductors under test in the range of $100 {\mu}H{\sim}1\;H$. The inductance of the inductor under test obtained in this study are consistent with those measured by LCR meter using the same inductor within an expanded uncertainty (k = 2) in the overall range of inductance.

비접촉식 진동 변위센서의 특성에 관한 연구 (Study on characteristics of noncontact vibrating displacement sensor)

  • 조철환;조성태;양경현
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.13-18
    • /
    • 2011
  • This thesis is about the result of conducting a specific experiment for the development of noncontact vibration displacement sensor for measuring the spindle vibration that is used for conditional monitoring of machinery. One should be careful when using the eddy current type displacement sensor because the sensitivity of it is different according to the quality of the material. While the probe used for nondestructive inspection adopts the effect of transmitting the material by using the high frequency domain, the eddy current type displacement sensor uses the lower frequency of around 1MHz. Also, while the nondestructive probe uses the method of enhancing output by using the resonance zone, the vibration displacement sensor utilizes the stable zone by avoiding the resonance zone. Since the oscillator of the converter uses the "L" element as Probe, its characteristic changes with the variation of a relevant impedance. In other words, if the length of Probe's Cable gets extended (Impedance increase), the sensitivity declines accordingly. The effect of surrounding temperature was small, but the influence of the quality of Sensor Coil used was high. Moreover, following an experimental demonstration of the phenomenon where the sensitivity decreases as the frequency of the tested material increases from a frequency response test, the maximum frequency that could be measured was approximately 1KHz. It was noted that the degree of precision could be maintained by using the gap of the probe in the linear zone at the installation site.

A Study on Displacement Measurement Hardware of Retaining Walls based on Laser Sensor for Small and Medium-sized Urban Construction Sites

  • Kim, Jun-Sang;Kim, Jung-Yeol;Kim, Young-Suk
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.1250-1251
    • /
    • 2022
  • Measuring management is an important part of preventing the collapse of retaining walls in advance by evaluating their stability with a variety of measuring instruments. The current work of measuring management requires considerable human and material resources since measurement companies need to install measuring instruments at various places on the retaining wall and visit the construction site to collect measurement data and evaluate the stability of the retaining wall. It was investigated that the applicability of the current work of measuring management is poor at small and medium-sized urban construction sites(excavation depth<10m) where measuring management is not essential. Therefore, the purpose of this study is to develop a laser sensor-based hardware to support the wall displacement measurements and their control software applicable to small and medium-sized urban construction sites. The 2D lidar sensor, which is more economical than a 3D laser scanner, is applied as element technology. Additionally, the hardware is mounted on the corner strut of the retaining wall, and it collects point cloud data of the retaining wall by rotating the 2D lidar sensor 360° through a servo motor. Point cloud data collected from the hardware can be transmitted through Wi-Fi to a displacement analysis device (notebook). The hardware control software is designed to control the 2D lidar sensor and servo motor in the displacement analysis device by remote access. The process of analyzing the displacement of a retaining wall using the developed hardware and software is as follows: the construction site manager uses the displacement analysis device to 1)collect the initial point cloud data, and after a certain period 2)comparative point cloud data is collected, and 3)the distance between the initial point and comparison point cloud data is calculated in order. As a result of performing an indoor experiment, the analyses show that a displacement of approximately 15 mm can be identified. In the future, the integrated system of the hardware designed here, and the displacement analysis software to be developed can be applied to small and medium-sized urban construction sites through several field experiments. Therefore, effective management of the displacement of the retaining wall is possible in comparison with the current measuring management work in terms of ease of installation, dismantlement, displacement measurement, and economic feasibility.

  • PDF