• Title/Summary/Keyword: Displacement Period

Search Result 528, Processing Time 0.025 seconds

Structural seismic response versus epicentral distance and natural period: the case study of Boumerdes (Algeria) 2003 earthquake

  • Dorbani, S.;Badaoui, M.;Benouar, D.
    • Structural Engineering and Mechanics
    • /
    • v.48 no.3
    • /
    • pp.333-350
    • /
    • 2013
  • This paper deals with the development of expressions relating structural seismic response parameters to the epicentral distances of an earthquake and the natural period of several reinforced concrete buildings (6, 9 and 12 storey), with three floor plans: symmetric, monosymmetric, and unsymmetric. These structures are subjected to seismic spectrum of accelerations collected during the Boumerdes earthquake (Algeria, May $21^{st}$, 2003, Mw=6.8) at different epicentral distances. The objective of this study is to develop relations between structural responses namely: base shear, storey displacements, interstory drifts and epicentral distance and fundamental period for a given earthquake. The seismic response of the buildings is carried out in both longitudinal transverse and directions by the response spectrum method (modal spectral approach).

Earthquake response spectra estimation of bilinear hysteretic systems using random-vibration theory method

  • Yazdani, Azad;Salimi, Mohammad-Rashid
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.1055-1067
    • /
    • 2015
  • A theoretical procedure to estimate spectral displacement of a hysteretic oscillator with bilinear stiffness excited by band-limited excitation is presented. The stochastic method of ground-motion simulation is combined with the random vibration theory to compute linear and nonlinear structural response. The response is obtained by computing the root-mean-square oscillator response using dissipation energy balancing by integrating over all energy levels of system weighting with the stationary probability density of the energy. The results are presented in a convenient form, and the accuracy of the procedure is assessed by comparison with results obtained with the time-domain method using the recorded data. The model shows little or no bias at the structural period of engineering interest.

Design of Large Displacement Piezoelectric Bimorphs with Finite Element Method (유한 요소법을 이용한 대변위 압전 Bimorph 설계)

  • 임종인;노용래;김선욱
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.4
    • /
    • pp.337-342
    • /
    • 1997
  • This paper describes the design and evaluation of new type piezoelectric bimorph actuator that shows much large mechanical response than those conventional types. The bimorph actuator has modified structure combined with the multilayer actuator(MLA) and the composite multilayer actuator called "Moonie". The design and performancean alysis of bimorph actuator are carried out with Finite Element Method (FEM). Theoretical calculation results show that the generating force and displacement of Moonie-modified bimorph actuator can be improved by about 130% and 150%, respectively. The overshooting and ringing phenomena of the bimorph can be effectively restrained by the pseudo step electric field having a rising time coincied with a period of the fundamental vibration mode of the bimorph.e bimorph.

  • PDF

Propositions of the Ductility Reduction Factor for Estimating Inelastic Displacement Responses of Bridge Structures (교량구조물의 비탄성변위응답 평가를 위한 연성도감소계수 산정식 제안)

  • Song, Jong-Keol;Kim, Hak-Soo
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.153-161
    • /
    • 2006
  • The main objective of this study was to derive a formula of ductility reduction factor, expressed as $R_{\mu}$. To attain this objective, a study comprised reduction factors computed for stiffness degrading systems undergoing different levels of ductility and to investigate an accuracy of the formula. Based on this study, the main conclusions can be summarized :(1) The ductility reduction factor is primarily affected by the period of the system and the displacement ductility ratio. (2) The proposed formula is simpler and the inelastic deformations of bridge structures are better than those by the others formulas we used before.

  • PDF

Creep of Plate Anchors Embedded in Bentonite (Bentonite에 근입된 앵커의 Creep 특성)

  • Shin, B.W.;Lee, J.D.;Shin, J.H.;Lee, B.J.
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.3-8
    • /
    • 1995
  • Anchors find their use in providing tie-back resistance for submerged footings, transmission towers, tunnels and ocean structures. Laboratory model teats were performed for the short-term net ultimate uplift capacity of a circular anchors with respect to various embedment depths and moisture content in saturated bentonite. The tests have been conducted with the anchor at two different moisture contents. Based an the model test results, empirical relationships between the net load, rate of strain, and time have been developed. Test results are as follows. 1) In creep tests for load versus ultimate uplift capacity, the displacement of plate anchors rapidly increases during the primary stage but thereafter becomes constant over a period of time. 2) Displacement increased with the increase of the sustain load and embedded ratio in soil. 3) If the load is less than or equal to 75% of the short-term ultimate uplift capacity, a complete pullout does not occur due to creep.

  • PDF

Seismic performance evaluation of a building structure using direct displacement-based design method (직접변위설계법을 이용한 건축물의 지진응답 산정)

  • 김진구;방성혁
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.569-576
    • /
    • 2001
  • In this study a procedure for evaluation of performance point using direct displacement-based design method was developed to enhance the applicability of the method. Parametric study has been performed for the natural period of the structure, yield strength, and the stiffness after the first yield. The proposed method was also applied to a 10-story steel frame. To verify the accuracy of the result, the results from capacity spectrum analysis and time history analysis were compared. The results of the proposed method turned out to match well with the results of capacity spectrum method and the time history analysis.

  • PDF

A comparative study on aseismic performances of base isolation systems for multi-span continuous bridge (다경간 연속교에 대한 면진용 교좌장치의 내진성능 비교연구)

  • Park, Kyu-Sik;Lee, Chong-Heon;Lee, In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.383-390
    • /
    • 2001
  • Various base isolation systems, which are widely used, are compared for aseismic performances of multi-span continuous bridge. They are the P-F, RB, LRB, R-FBI and EDF systems. Sensitivity analyses are carried out to determine the design parameters of various devices. The design parameters, natural period of the isolated bridge and friction coefficient of the bearing, are determined by the reciprocal relationship between displacement and bending moment of the structure. Then the relative effectiveness of the bearings is described. Bridge with the R-FBI system shows the smallest peak displacement of deck whereas bridge with the EDF system shows the smallest peak bending moment of the lower end of pier in numerical examples. Furthermore, the peak responses of bridge with the friction type bearing are less sensitive to substantial variations in the frequency range and intensity of the ground excitation than those with the rubber type bearing.

  • PDF

Development of High Load/Large Displacement Actuator for Micro-press (마이크로 프레스용 고하중/대변위 액츄에이터 개발)

  • KIM B. H.;NAM K. S.;CHOI J. P.;KIM H. Y.;LEE N. K.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.458-461
    • /
    • 2005
  • In this paper, a new type of inchworm motion actuator is developed in fabrication of actuators for micro-press machine. This is consisted of three piezoelectric actuators, one is for moving the tool guide and the other are for clamping the guide. The inchworm motor provides both high load and large displacement in small size actuator. PZT has compressive strength and often fails under tensile stress and pulling. Thus, in order to prevent failure, we have designed pre-load housing and accomplished FEM analysis. The pre-load housing was used for determining the optimal design condition by comparing the von-mises stresses with the change of hinge stiffness. Also, in order to predict the performance of the motor under certain conditions, the system model was simulated using MATLAB. This is open loop control actuator and driven by the period of input voltage.

  • PDF

Dynamic responses of track according to the hardening of rail-pad (레일패드의 경화에 따른 궤도의 동적응답 변화 특성 분석)

  • Yoon, Tae-Hyoung;Choi, Jin-Yu;Yang, Shin-Chu;Kim, Eun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.454-459
    • /
    • 2006
  • A wheel force becomes large as increasing the stiffness of rail-pad, and it accelerates the deterioration of track, and it leads the maintenance cost rising. So, it is required to determine an appropriate replacement period for rail-pad. As a preliminary study to determine it, a numerical analysis was conducted to investigate the influence on a track behavior by the hardening of rail-pad. From the analysis, one knows that the dynamic wheel force is vary depend on the stiffness of rail-pad and the running speed of vehicle, the displacement and acceleration of rail is decreasing as increasing stiffness of rail-pad, and the displacement and acceleration increased in proportion to the rail-pad stiffness increasing.

  • PDF

Seismic Performance Evaluation for MCR of Nuclear Power Plant Isolated by FPS (FPS로 면진된 원전 주제어실의 내진 성능 평가)

  • 김대곤;김우범;서용표;문대식;김종엽
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.453-460
    • /
    • 2003
  • The objective of this study is to investigate the seismic performance for a seismically isolated main control room (MCR) of nuclear power plant. MCR was isolated by spherically shaped friction pendulum system (FPS). The FPS provided the simplest means of achieving long period in the isolation system under low gravity load. Some parametric studies were conducted with different properties of FPS. When the coefficient of friction in the sliding surface of FPS is low, the seismic performance of MCR was satisfactory However, the lateral displacement in the isolation level was rather large. To restrict this displacement into adequate range, a fluid viscous dampers were used.

  • PDF