• 제목/요약/키워드: Dispersion evaluation

검색결과 358건 처리시간 0.027초

0.75[kW]급 삼상유도전동기 효율의 불확도 평가에 관한 연구 (Study on the Evaluation of Uncertainty for the Efficiency of 0.75[kW] Class Three Phase Induction Motor)

  • 전희득;박한석;김대경;우경일
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.653-659
    • /
    • 2015
  • In the last few years, the regulations for efficiency grade of the three phase induction motor are internationally being discussed and upgraded for the protection of environment and energy saving. So the efficiency improvement and the reliable test result are essential to determine the premium grade three phase induction motor. While a study on developing the efficiency motor is active, there is little research about the guarantee for efficiency. So in this paper, the dispersion characteristic of the efficiency is studied using uncertainty theory for the three phase induction motor to improve the reliability of efficiency. The values such as input voltage, current, speed, torque were obtained by loss separation method to evaluate the uncertainty. From the result, it was known that the important loss factor could affect the uncertainty is the stray loss.

Proposal of the Penalty Factor Equations Considering Weld Strength Over-Match

  • Kim, Jong-Sung;Jeong, Jae-Wook;Lee, Kang-Yong
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.838-849
    • /
    • 2017
  • This paper proposes penalty factor equations that take into consideration the weld strength over-match given in the classified form similar to the revised equations presented in the Code Case N-779 via cyclic elastic-plastic finite element analysis. It was found that the $K_e$ analysis data reflecting elastic follow-up can be consolidated by normalizing the primary-plus-secondary stress intensity ranges excluding the nonlinear thermal stress intensity component, $S_n$ to over-match degree of yield strength, $M_F$. For the effect of over-match on $K_n{\times}K_{\nu}$, dispersion of the $K_n{\times}K_{\nu}$ analysis data can be sharply reduced by dividing total stress intensity range, excluding local thermal stresses, $S_{p-lt}$ by $M_F$. Finally, the proposed equations were applied to the weld between the safe end and the piping of a pressurizer surge nozzle in pressurized water reactors in order to calculate a cumulative usage factor. The cumulative usage factor was then compared with those derived by the previous $K_e$ factor equations. The result shows that application of the proposed equations can significantly reduce conservatism of fatigue assessment using the previous $K_e$ factor equations.

A STUDY OF HYDRAULIC PROPERTIES IN A SINGLE FRACTURE WITH IN-PLANE HETEROGENEITY: AN EVALUATION USING OPTICAL MEASUREMENTS OF A TRANSPARENT REPLICA

  • Sawada, Atsushi;Sato, Hisashi
    • Nuclear Engineering and Technology
    • /
    • 제42권1호
    • /
    • pp.9-16
    • /
    • 2010
  • Experimental examinations for evaluating fracutres were conducted by using transparent replicas of a single fracture in order to obtain the fracture data to contribute to the methodlogy on how to improve the definitaion of representative parameter values used for a parallel plate fracture model. Quantitative aperture distribution and quantitative tracer concentration data at each point in time were obtained by measuring the attenuation of transmitted light through the fracture in high spatial resolution. the representative aperture values evaluated from the multiple different measurement methods, such as arithmetic mean of aperture distribution measured by the optical method, transport aperture evaluated from the tracer test, and average aperture evaluated from the fracture void volume measurement converged to a unique value that indicates the accuracy of this experimental study. The aperture data was employed for verifying the numerical simulation under the assuption of Local Cubic Law and showed that the calculated flow rate through the fracture is 10%-100% larger than hydraulic test results. The quantitative tracer concentration data is also very valuable for validating existing numerical code for advection dispersion transport in-plane heterogeneous fractures.

뜨임한 구조용강 SCM435의 경도 및 충격 흡수에너지에 대한 신뢰성 평가 (Reliability Evaluation of Hardness and Impact Absorption Energy of Tempered Structure Steel SCM435)

  • 윤서현;구세훈;남기우
    • 한국산업융합학회 논문집
    • /
    • 제22권6호
    • /
    • pp.681-688
    • /
    • 2019
  • SM45C steel, which is widely used for mechanical structure, was carburized at 870℃ for 4 hours and tempered at 300℃ and 400℃ for 1, 3 and 6 hours. The tempered materials were evaluated for tensile test, hardness test and impact test. In particular, the hardness and the absorption energy were evaluate the reliability by the Weibull statistical analysis. 300℃-1h specimen is considered to be the best heat treatment condition in the tensile stress and the observation of fracture surface. 300℃-1h specimen showed larger shape and scale parameter than the other specimens, and Rockwell hardness variance was small and showed the best characteristics. 400℃-3h specimen showed larger shape and scale parameter than the other specimens, the dispersion of impact absorption energy is small, and showed excellent characteristics.

Cpk Index Estimation under Tw (the weakest t-norm)-based Fuzzy Arithmetic Operations

  • Hong, Dug-Hun
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제8권3호
    • /
    • pp.170-174
    • /
    • 2008
  • The measurement of performance of a process considering both the location and the dispersion of information about the process is referred to as the process capacity indices (PCIs) of interest, $C_{pk}$. This information is presented by the mean and standard deviation of the producing process. Linguistic variables are used to express the evaluation of the quality of a product. Consequently, $C_{pk}$ is defined with fuzzy numbers. Lee [Eur. J. Oper. Res. 129(2001) 683-688] constructed the definition of the $C_{pk}$ index estimation presented by fuzzy numbers and approximated its membership function using the "min" - norm based Zadeh's extension principle of fuzzy sets. However, Lee's result was shown to be invalid by Hong [Eur. J. Oper. Res. 158(2004) 529-532]. It is well known that $T_w$ (the weakest t-norm)-based addition and multiplication preserve the shape of L-R fuzzy numbers. In this paper, we allow that the fuzzy numbers are of L-R type. The object of the present study is to propose a new method to calculate the $C_{pk}$ index under $T_w-based$ fuzzy arithmetic operations.

Evaluation of a DDB design method for bridges isolated with triple pendulum bearings

  • Amiri, Gholamreza Ghodrati;Shalmaee, Mahdi Mohammadian;Namiranian, Pejman
    • Structural Engineering and Mechanics
    • /
    • 제59권5호
    • /
    • pp.803-820
    • /
    • 2016
  • In this study a direct displacement-based design (DDBD) procedure for a continuous deck bridge isolated with triple friction pendulum bearings (TFPB) has been proposed and the seismic demands of the bridge such as isolator's displacement and drift of piers obtained from this procedure evaluated under two-directional near-field ground motions. The structural model used here are continuous, three-span, castin-place concrete box girder bridge with a 30-degree skew which are isolated with 9 different TFPBs. By comparing the results of DDBD method with those of nonlinear time history analysis (NTHA), it can be concluded that the proposed procedure is able to predict seismic demands of similar isolated bridges with acceptable accuracy. Results of NTHA shows that dispersion of peak resultant responses for a group of ground motions increases by increasing their average value of responses. It needs to be noted that the demands parameters calculated by the DDBD procedure are almost overestimated for stiffer soil condition, but there is some underestimation in results of this method for softer soil condition.

Evaluation of dynamic behavior of coagulation-flocculation using hydrous ferric oxide for removal of radioactive nuclides in wastewater

  • Kim, Kwang-Wook;Shon, Woo-Jung;Oh, Maeng-Kyo;Yang, Dasom;Foster, Richard I.;Lee, Keun-Young
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.738-745
    • /
    • 2019
  • Coprecipitation using hydrous ferric oxide (HFO) has been effectively used for the removal of radionuclides from radioactive wastewater. This work studied the dynamic behavior of HFO floc formation during the neutralization of acidic ferric iron in the presence of several radionuclides by using a photometric dispersion analyzer (PDA). Then the coagulation-flocculation system using HFO-anionic poly acrylamide (PAM) composite floc system was evaluated and compared in seawater and distilled water to find the effective condition to remove the target nuclides (Co-60, Mn-54, Sb-125, and Ru-106) present in wastewater generated in the severe accident of nuclear power plant like Fukushima Daiichi case. A ferric iron dosage of 10 ppm for the formation of HFO was suitable in terms of fast formation of HFO flocs without induction time, and maximum total removal yield of radioactivity from the wastewater. The settling time of HFO flocs was reduced by changing them to HFO-PAM composite floc. The optimal dosage of anionic PAM for HFO-anionic PAM floc system was approximately 1-10 ppm. The total removal yield of Mn-54, Co-60, Sb-125, Ru-106 radionuclides by the HFO-anionic PAM coagulation-flocculation system was higher in distilled water than in seawater and was more than 99%.

Evaluation of ground motion scaling methods on drift demands of energy-based plastic designed steel frames under near-fault pulse-type earthquakes

  • Ganjavi, Behnoud;Hadinejad, Amirali;Jafarieh, Amir Hossein
    • Steel and Composite Structures
    • /
    • 제32권1호
    • /
    • pp.91-110
    • /
    • 2019
  • In the present study, the effects of six different ground motion scaling methods on inelastic response of nonlinear steel moment frames (SMFs) are studied. The frames were designed using energy-based PBPD approach with the design concept using pre-selected target drift and yield mechanism as performance limit state. Two target spectrums are considered: maximum credible earthquake spectrum (MCE) and design response spectrum (DRS). In order to investigate the effects of ground motion scaling methods on the response of the structures, totally 3216 nonlinear models including three frames with 4, 8 and 16 stories are designed using PBPD approach and then they are subjected to ensembles of ground motions including 42 far-fault and 90 near-fault pulse-type records which were scaled using the six different scaling methods in accordance to the two aforementioned target spectrums. The distributions of maximum inter-story drift over the height of the structures are computed and compared. Finally, the efficiency and reliability of each ground motion scaling method to estimate the maximum nonlinear inter-story drift of special steel moment frames designed by energy-based PBPD approach are statistically investigated, and the most suitable scaling methods with the lowest dispersion for two groups of earthquake ground motions are introduced.

PMSG 풍력발전기용 3L NPC와 ANPC 컨버터에서의 10kV IGCT 성능 비교 평가 (Comparative performance evaluation of 10kV IGCTs in 3L NPC and ANPC Converter in PMSG MV Wind Turbines)

  • 암리나라마;서용석;박병건;김지원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.86-88
    • /
    • 2018
  • The three level(3L) neutral point clamped (NPC) voltage source converter (VSC) topology is widely used for grid interface in high power wind energy due to its superior performance as compared to the two level(2L) VS. However, one of the major drawbacks of this topology is the unequal dispersion of loss and therefore the junction temperature among the power devices. The 3L ANPC topology derived from the NPC topology was proposed to resolve this drawback of unequal loss profile of 3L NPC. The 3L ANPC can work under various switching strategies. In this paper a comparative study of the various switching strategies of 3L ANPC using the recently developed 10kV IGCTs which has the capability to raise the current and voltage rating of the wind turbines is carried out. The comparison is performed using ABB make 10kV IGCT 5SHY17L9000 and PLECs simulations.

  • PDF

Evaluation of reaction site prediction in 3-ring PAHs according to calculation level

  • Lee, Byung-Dae
    • 한국응용과학기술학회지
    • /
    • 제39권4호
    • /
    • pp.535-541
    • /
    • 2022
  • The radical reaction position was calculated by varying the calculation level for ACEL and ANT, which are detected with the highest frequency and concentration in PAHs pollution sites. The results of each calculation level were compared and evaluated with the existing literature. HF, B3LYP, B3LYP-D, and MP2 were used as the method for each level used for calculation. Except for HF, the MK charge by B3LYP, B3LYP-D, and MP2 was consistent with the experimental results. It was found that the dispersion effect was negligible in the calculation of ACEL and ANT because the calculation results by the B3LYP and B3LYP-D methods were the same. In particular, it was found that the MK charge calculation result by MP2 agrees well with the product/PAH ratio obtained as a result of the experiment. Considering the calculation cost, it would be preferable to use B3LYP to predict the radical reaction site of ACEL and ANT. However, considering the product/PAH ratio, it takes more time to calculate, but it is judged that it is better to use the MP2.