• Title/Summary/Keyword: Dispenser

Search Result 136, Processing Time 0.029 seconds

A Study on Opinion of Korean Feminine Seniors on the Life Support Appliances for Healthy Ageing - Medication Dispenser, Video Phone, Activity Monitor, Sleep Monitor - (재가노인 생활지원기기에 대한 한국 여성노인의 인식 - 알약분배기, 비디오폰, 활동모니터, 취침모니터를 중심으로 -)

  • Steggell, Carmen D.;Park, Kyoung-Ok;Kim, Sun-Joong;Kwon, Myoung-Hee
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.4
    • /
    • pp.83-96
    • /
    • 2008
  • The purpose of this study is to grasp the opinion of Korean feminine seniors on the life support appliances for their healthy ageing: medication dispenser, video phone, activity monitor and sleep monitor. The focus group interviews, asking the usability of the appliances, were answered by each 6 feminine seniors of more than 65 years, residing in Corvallis of U.S.(group I), Cheongju(group II), and Ulsan(group III) of Korea. The results are as follows. (1) The medication dispenser proved to be very useful to all the respondents. All the seniors, who take more than one medicine a day, felt it helpful that the medication dispenser makes them to take medicines at fixed time. In addition, they hoped the medicine envelope to be developed for the dispenser use by the supply side. (2) The seniors showed interest in the manner the video phone works; to work by the voice, rather than by the finger. They expressed the hope of the video phone to display the communication contents, in consideration of their weakening hearing. (3) The seniors who live alone, especially, felt intimacy to the activity monitor, thinking as if some helpers were beside them. The fact that it can send emergency calls immediately when situations happen, gave the seniors emotional safety as a patron. (4) The sleep monitor, although essential to the serious cases without moving ability, was proved less necessary to the healthy seniors. They expressed the hope of this appliance to be evolved for the use with the mattress without bed.

Development of Wax-typed Pheromone Dispenser for Mating Discruption of the Oriental Fruit Moth, Grapholita molesta, and Its Application Technique (복숭아순나방(Grapholita molesta) 교미교란용 왁스형 페로몬방출기와 그 적용 기술 개발)

  • Jung, Sung-Chae;Park, Man-Woong;Lee, Soon-Won;Choi, Kyung-Hee;Hong, Yong-Pyo;Bae, Sung-Woo;Kim, Yong-Gyun
    • Korean journal of applied entomology
    • /
    • v.47 no.3
    • /
    • pp.255-263
    • /
    • 2008
  • A wax-typed pheromone dispenser has been developed and applied to control outbreak of the oriental fruit moth, Grapholita molesta, in apple orchard. To optimize its application technique, this study analyzed effect of different amounts of the pheromone dispenser on mating disruption('MD') of G. molesta. Different pheromone dispenser amounts significantly influenced the MD effect assessed by cumulative male adult catches monitored respectively by sticky delta trap and food trap, and resulted in differential damage on host plants. In a field test during entire growing season, a standard amount(120 g per 0.117 ha) of wax-typed pheromone dispenser was proved to be effective to suppress outbreak of G. molesta adults and to prevent host plant damage as much as a current commercial MD product($Isomate^{(R)}$). This study also demonstrated an effectiveness of deployment of food trap barriers around MD-treated area to prevent immigration of mated females from outside untreated areas. These results indicate that the wax-typed pheromone dispenser can be applied to control field G. molesta populations and its co-application with fuod trap barriers would be optimal to maximize MD efficacy.

Improvement for Response Delays of Displacement Magnifier in Jetting Dispenser (젯팅 디스펜서 변위확대장치의 응답지연 개선 연구)

  • Ha, Myeong-Woo;Lee, Kwang-Hee;Hong, Seung-Min;Lee, Chul-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.546-551
    • /
    • 2016
  • The objective of this study is to investigate the response delays between piezo-stack actuator and the displacement magnifier of jetting dispenser and to reduce its falling time in terms of displacement optimization. The dispenser is driven by the dual piezo-stack actuators with a hinge lever mechanism to precisely control flow rate of the working fluid (3000 cP). It is commonly found that piezo actuator-driven jetting dispensers involving viscous working fluids have displacement optimization problem for ideal performance. The response delay of the system is caused by the phenomenon that the displacement magnifier cannot exactly follow the motion of the piezo actuators. The response delay may lower the performance of the system due to the inaccurate discharge of working fluid or even damages to the system itself due to inharmonious motion of piezo actuators with lever system. To reduce its response delay, a new displacement profile obtained from displacement optimization is suggested; its performance is tested through finite element analysis; and experiments are carried out to verify the performance of the obtained displacement profile.

Research about banking automation device design development (은행자동화기기 디자인개발에 관한 연구)

  • Ho, Sung-Jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.05a
    • /
    • pp.462-465
    • /
    • 2006
  • Now a days the banks, with a wide spread of credit transaction practice in every business, offer better services to their customers, while the automation of banking is being made more rapid progress in th light of efficient banking service. For example, it is true that the automation of cash payment for customers goes on its progress and the competition between companies is getting more serious. Lately the banks that pursue "Banking Automation System" expand distribution of cash dispenser for the better electronic computer service and for the better service for their customers in quality. Therefore the makers producing "CD" accelerate their development of CD in various ways in order to secure M/S as the leading group of th field. CD, a kind of an automatic paying, is being used generally, and has various functions and its design is getting more compact than ever. Under this situation, I studied more trustworthy and convenient CD design suggestions in the way of case study on the basis of the process of developing CD and I suggest the better way of developing the design of CD in the future.

  • PDF

Field Assessment of Two Commercial Sex Pheromone Mating Disruptors on Male Orientation of Oriental Fruit Moth, Grapholita molesta (Busck) (두 가지 상용 교미교란제의 야외 복숭아순나방 (Grapholita molesta (Busck)) 수컷 유인교란 효과 비교)

  • Jung, Sung-Chae;Park, Chun-Woo;Park, Man-Woong;Kim, Yong-Gyun
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.1
    • /
    • pp.46-51
    • /
    • 2007
  • In this study, two commercial mating disruptors were compared in terms of disruption of Oriental fruit moth, Grapholita molesta, male orientation, in which a new dispenser type, $SPLAT^{(R)}$, was compared with a current dispenser type, $Isomate^{(R)}$-M ROSSO. For this assessment, the last three year field monitoring data were analyzed for the efficacy of Isomate type dispenser. Then two commercial dispensers were compared in different localities with sub-locality replications during identical monitoring period from mid February to late August. There appeared to be four adult population peaks, in which the overwintering population size was positively correlated with the following reproductive population sizes. Isomate type dispenser effectively suppressed G. molesta populations during all growing seasons with some annual variation in its efficacy. Between two dispensers, SPLAT type was much effective. The difference in their efficacy may be caused by the difference in composition of major pheromone component.

Development of a Non-contact Liquid Dispenser for High Contents Screening System (세포 기반 고집적 스크리닝 시스템용 비접촉식 고정밀 마이크로 디스팬서 제작)

  • Cho, Seong J.;Kim, Intae;Lim, Geunbae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.581-585
    • /
    • 2016
  • Nowadays medical treatment service increase due to ageing population and improving the quality of life. Accordingly it is predicted that drug discovery market will expansion continuously. Therefore it is necessary that profit creation by drug discovery on the global market is important. HCS(High Contents Screening) has been emerging as a potential method to solve problems of the present drug discovery. This research is about liquid dispenser for HCS. The purpose of this research is to manufacture high performance liquid dispenser for HCS. The dispenser is designed to control 5 liquids separately. The liquid contact parts are designed disposably, biocompatibly and chemically inertly. Air curtain is equipped at the side of tip to dispense very small liquid volume and to prevent hanging drop on tip. Valving is performed by just controlling the pressure of the pressure driven pump without valve.

A Study on Developing A Design of Cash Dispenser - With a Focus on LG Co. Cash Dispenser - (현금 인출기 디자인 개발 사례 연구 - (주) LG 전자 현금 인출기를 중심으로 -)

  • 오성진
    • Archives of design research
    • /
    • v.12 no.2
    • /
    • pp.5-16
    • /
    • 1999
  • Nowadays the banks, with a wide spread of credit transaction practice in every business, offer better services to their customers, while the automation of banking is being made more rapid progress in th light of efficient banking service. For example, it is true that the automation of cash payment for customers goes on its progress and the competition between companies is getting more serious. Lately the banks that pursue "Banking Automation System" expand distribution of cash dispenser for the better electronic computer service and for the better service for their customers in quality. Therefore the makers producing "CD" accelerate their development of CD in various ways in order to secure MIS as the leading group of th field. CD, a kind of an automatic paying, is being used generally, and has various functions and its design is getting more compact than ever. Under this situation, I studied more trustworthy and convenient CD design suggestions in the way of case study on the basis of the process of developing CD and I suggest the better way of developing the design of CD in the future.of CD in the future.

  • PDF

Design and Control of Jetting Dispenser Driven by Piezoelectric Actuator (압전 작동기로 구동되는 젯팅 디스펜서의 설계 및 제어)

  • Choi, Min-Kyu;Nguyen, Quoc-Hung;Yun, Bo-Young;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1165-1171
    • /
    • 2006
  • This paper presents a new type of jetting dispenser for the integrated circuit (IC) fabrication and surface mount technology The proposed system is featured by the piezoelectric actuator and hydraulic magnification device. After describing structural component of the dispensing mechanism and its operation principle, both the fluid modeling and the hydraulic magnification modeling are undertaken with a lumped-parameter method based on the analogy of the fluid system and mechanical system. A mathematical governing equation is then derived by integrating the fluid model with the mechanical model of the driving piston and piezoelectric actuator. Subsequently, in order to achieve a desired dispensing amount, control algorithm adjusting duty cycle of the driving voltage is synthesized and control responses are presented in time domain.