• Title/Summary/Keyword: Disk Imaging

Search Result 120, Processing Time 0.029 seconds

A Case of Treatment of Idiopathic Immune-Mediated Polyarthritis in a Dog (개에서 발생한 특발성 면역매개성 다발성관절염의 치료 증례)

  • Eom, Na-Young;Lee, Hee-Chun;Jang, Hyo-Mi;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.366-369
    • /
    • 2015
  • A 12-year-old, castrated male, mixed-breed dog was referred to us with a history of depression, lameness, neck and multiple joints pain. Clinical signs had been deteriorating from rear limbs lameness leading to pain on all four limbs lameness for 7 days. Mild leukocytosis and increased C-reactive protein concentration were revealed in blood work. On radiography, degenerative change of humerus and cervical intervertebral space narrowing were found. The results of synovial fluid analysis revealed severe neutrophilic pleocytosis, decreased viscosity, increased turbidity and bacterial culture was negative. The antinuclear antibody test was negative and MRI results revealed mild cervical intervertebral disk disease (IVDD). Based on all tests, we diagnosed this case as idiopathic immune-mediated polyarthritis (IMPA). Prednisolone and mycophenolate mofetil were administered and clinical signs were resolved after 7 days. This case report demonstrated that clinical, diagnostic imaging and synovial fluid analysis findings and successful treatment result with prednisolone and mycophenolate mofetil in canine idiopathic IMPA.

Evaluation of the radiopacity of restorative materials with different structures and thicknesses using a digital radiography system

  • Yaylaci, Ayla;Karaarslan, Emine Sirin;Hatırli, Huseyin
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.261-269
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the radiopacities of various types of restorative materials with different thicknesses compared with enamel, dentin, and aluminum. Materials and Methods: Four bulk-fill resins, 2 hybrid ceramics, 2 micro-hybrid resin composites, 6 glass ionomer-based materials, 2 zinc phosphate cements, and an amalgam were used in the study. Twelve disk-shaped specimens were prepared from each of 17 restorative materials with thicknesses of 1 mm, 2 mm, and 4 mm (n=4). All the restorative material specimens with the same thickness, an aluminum (Al) step wedge, and enamel and dentin specimens were positioned on a phosphor storage plate and exposed using a dental X-ray unit. The mean gray values were measured on digital images and converted to equivalent Al thicknesses. Statistical analyses were performed using 2-way analysis of variance and the Bonferroni post hoc test(P<0.05). Results: Radiopacity was significantly affected by both the thickness and the material type (P<0.05). GCP Glass Fill had the lowest radiopacity value for samples of 1 mm thickness, while Vita Enamic had the lowest radiopacity value for 2-mm-thick and 4-mm-thick samples. The materials with the highest radiopacity values after the amalgam were zinc phosphate cements. Conclusion: Significant differences were observed in the radiopacities of restorative materials with different thicknesses. Radiopacity was affected by both the material type and thickness.

Color Dispersion as an Indicator of Stellar Population Complexity for Galaxies in Clusters

  • Lee, Joon Hyeop;Pak, Mina;Lee, Hye-Ran;Oh, Sree
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.34.1-34.1
    • /
    • 2018
  • We investigate the properties of bright galaxies with various morphological types in Abell 1139 and Abell 2589, using the pixel color-magnitude diagram (pCMD) analysis. The 32 bright member galaxies ($Mr{\leq}-21.3mag$) are deeply imaged in the g and r bands in our CFHT/MegaCam observations, as a part of the KASI-Yonsei Deep Imaging Survey of Clusters (KYDISC). We examine how the features of their pCMDs depend on galaxy morphology and infrared color. We find that the g - r color dispersion as a function of surface brightness (${\mu}r$) shows better performance in distinguishing galaxy morphology, than the mean g - r color does. The best set of parameters for galaxy classification appears to be a combination of the minimum color dispersion at ${\mu}r{\leq}21.2mag\;arcsec-2$ and the maximum color dispersion at $20.0{\leq}{\mu}r{\leq}21.0mag\;arcsec-2$: the latter reflects the complexity of stellar populations at the disk component in a typical spiral galaxy. Moreover, the color dispersion of an elliptical galaxy appears to be correlated with its WISE infrared color ([4.6]-[12]). This indicates that the complexity of stellar populations in an elliptical galaxy is related to its recent star formation activities. From this observational evidence, we infer that gas-rich minor mergers or gas interactions may have usually occurred during the recent growth of massive elliptical galaxies.

  • PDF

Investigating the sensitivity of the clumpy torus model parameters to the IR data in QSOs

  • Kim, HyeongHan;Martinez-Paredes, Mariela;Sohn, Bong Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.73.3-73.3
    • /
    • 2019
  • The AGN unification model suggested the presence of obscuring material, a dusty torus, to explain the various types of AGN. IR SED model fitting is a crucial tool to probe the structure and properties of the dusty torus. We use a sample of 16 local quasi-stellar objects in Martinez-Paredes et al. (2017) with obtained NIR and MIR high-angular resolution (~0.3") imaging data from EMIR, CIRCE and CanariCam on the 10.4-m Gran Telescopio CANARIAS (GTC) while 4 objects have NIR high-angular resolution photometry from NICMOS/HST from the literature. The unresolved NIR emission from the NIR image analysis and low-resolution Spitzer/IRS spectra are used to construct NIR-MIR SEDs covering a larger spectral range. We investigate the sensitivity of the geometrical (e.g. viewing angle) and physical parameters (e.g. optical depth) of the clumpy dusty torus model of Nenkova et al. and the clumpy disk+outflow model of Hoenig et al. We aim to investigate the minimal dataset needed to well constrain the parameters of the models and derive the properties of the dusty torus. These results will allow us to plan future observations for a larger sample of high luminosity AGNs with the James Webb Space Telescope and the Giant Magellan Telescope.

  • PDF

Stellar photometric Properties in the outskirt of NGC 5236

  • Kim, Sanghyun;Kim, Minjin;Byun, Woowon;Sheen, Yun-Kyeong;Ho, Luis C;Lee, Joon Hyeop;Kim, Sang Chul;Jeong, Hyunjin;Park, Byeong-Gon;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.60.2-60.2
    • /
    • 2020
  • In the hierarchical framework, galaxies grow through mergers and accretion. Those mechanisms leave faint features, such as stellar streams, shells and smooth stellar halos in the outskirts of galaxies. In order to search for those features in the nearby galaxies, we are conducting a KMTNet Nearby Galaxy Survey using the Korea Microlensing Telescope Network. We present a deep and wide-field imaging of NGC 5236, a barred spiral galaxy. In one-dimensional surface brightness profiles, we reach 28, 29 mag/arcsec2 in the R- and B-band, respectively. We find that the outer disk of NGC 5236 can be well described with a single exponential profile up to 17 kpc (~3.8 Reff) indicating that the excess light due to the stellar halo is not clearly detected. B-R color gradually increases towards the outskirts of the galaxy. It may reveal that stellar properties in the outskirts are marginally distinctive from those in the central part.

  • PDF

DEVELOPMENT OF A LYMAN-α IMAGING SOLAR TELESCOPE FOR THE SATELLITE (인공위성 탑재용 자외선 태양카메라(LIST) 개발)

  • Jang, M.;Oh, H.S.;Rim, C.S.;Park, J.S.;Kim, J.S.;Son, D.;Lee, H.S.;Kim, S.J.;Lee, D.H.;Kim, S.S.;Kim, K.H.
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.3
    • /
    • pp.329-352
    • /
    • 2005
  • Long term observations of full-disk Lyman-o irradiance have been made by the instruments on various satellites. In addition, several sounding rockets dating back to the 1950s and up through the present have measured the $Lyman-{\alpha}$ irradiance. Previous full disk $Lyman-{\alpha}$ images of the sun have been very interesting and useful scientifically, but have been only five-minute 'snapshots' obtained on sounding rocket flights. All of these observations to date have been snapshots, with no time resolution to observe changes in the chromospheric structure as a result of the evolving magnetic field, and its effect on the Lyman-o intensity. The $Lyman-{\alpha}$ Imaging Solar Telescope(LIST) can provide a unique opportunity for the study of the sun in the $Lyman-{\alpha}$ region with the high time and spatial resolution for the first time. Up to the 2nd year development, the preliminary design of the optics, mechanical structure and electronics system has been completed. Also the mechanical structure analysis, thermal analysis were performed and the material for the structure was chosen as a result of these analyses. And the test plan and the verification matrix were decided. The operation systems, technical and scientific operation, were studied and finally decided. Those are the technical operation, mechanical working modes for the observation and safety, the scientific operation and the process of the acquired data. The basic techniques acquired through the development of satellite based solar telescope are essential for the construction of space environment forecast system in the future. The techniques which we developed through this study, like mechanical, optical and data processing techniques, could be applied extensively not only to the process of the future production of flight models of this kind, but also to the related industries. Also, we can utilize the scientific achievements which are obtained throughout the project And these can be utilized to build a high resolution photometric detectors for military and commercial purposes. It is also believed that we will be able to apply several acquired techniques for the development of the Korean satellite projects in the future.

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF

Evaluation of Dimensions of Kambin's Triangle to Calculate Maximum Permissible Cannula Diameter for Percutaneous Endoscopic Lumbar Discectomy : A 3-Dimensional Magnetic Resonance Imaging Based Study

  • Pairaiturkar, Pradyumna Purushottam;Sudame, Onkar Shekhar;Pophale, Chetan Shashikant
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.414-421
    • /
    • 2019
  • Objective : To evaluate 3-dimensional magnetic resonance imaging (MRI) of Kambin's safe zone to calculate maximum cannula diameter permissible for safe percutaneous endoscopic lumbar discectomy. Methods : Fifty 3D MRIs of 19 males and 31 females (mean, 47 years) were analysed. Oblique, axial and sagittal views were used for image analysis. Three authors calculated the inscribed circle (cannula diameter) individually, within the neural (original) and bony Kambin's triangle in oblique views, disc heights on sagittal views and root to facet distances at upper and lower end plate levels on axial views and their averages were taken. Results : The mean root to facet distances at upper end plate level measured on axial sections increased from $3.42{\pm}3.01mm$ at L12 level to $4.57{\pm}2.49mm$ at L5S1 level. The mean root to facet distances at lower end plate level measured on axial sections also increased from $6.07{\pm}1.13mm$ at L12 level to $12.9{\pm}2.83mm$ at L5S1 level. Mean maximum cannula diameter permissible through the neural Kambin's triangle increased from $5.67{\pm}1.38mm$ at L12 level to $9.7{\pm}3.82mm$ at L5S1 level. The mean maximum cannula diameter permissible through the bony Kambin's triangle also increased from $4.03{\pm}1.08mm$ at L12 level to $6.11{\pm}1mm$ at L5S1 level. Only 2% of the 427 bony Kambin's triangles could accommodate a cannula diameter of 8mm. The base of the bony Kambin's triangle taken in oblique view (3D MRI) was significantly higher than the root to facet distance at lower end plate level taken in axial view. Conclusion : The largest mean diameter of endoscopic cannula passable through "bony" Kambin's triangle was distinctively smaller than the largest mean diameter of endoscopic cannula passable through "neural" Kambin's triangle at all levels. Although proximity of exiting root to the facet joint is always taken into consideration before PELD procedure, our 3D MRI based anatomical study is the first to provide actual maximum cannula dimensions permissible in this region.

Spinal Cord Ependymoma Associated with Neurofibromatosis 1 : Case Report and Review of the Literature

  • Cheng, Hongwei;Shan, Ming;Feng, Chunguo;Wang, Xiaojie
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.1
    • /
    • pp.43-47
    • /
    • 2014
  • Patients with neurofibromatosis 1 (NF1) are predisposed to develop central nervous system tumors, due to the loss of neurofibromin, an inactivator of proto-oncogene Ras. However, to our knowledge, only three cases of ependymomas with NF1 have been reported in the literature. The authors present a case of NF1 patient with a spinal cord ependymoma. She was referred for about half a year history of increasing numbness that progressed from her fingers to her entire body above the bellybutton. Magnetic resonance imaging revealed a relative-demarcated, heterogeneously enhanced mass lesion accompanied by perifocal edema in C5-7 level, a left-sided T11 spinous process heterogeneously enhanced mass in soft tissue, intervertebral disk hernia in L2-5 level, and widespread punctum enhancing lesion in her scalp and in T11-L5 level. The patient underwent C5-7 laminectomies and total excision of the tumor under operative microscope, and intraoperative ultrasonography and physiological monitoring were used during the surgery. Histopathologically, her tumor was found to be a ependymoma without malignant features (grade II in the World Health Organization classification). Therefore, no adjuvant therapy was applied. Following the operation, the patient showed an uneventful clinical recovery with no evidence of tumor recurrence after one year of follow-up.

Bradycardia after Dobutamine Administration in a Dog (Dobutamine 투여 후 발생한 개의 서맥 1례)

  • Jang, Min;Son, Won-Gyun;Hwang, Hyeshin;Jo, Sang-Min;Yi, Kang-Jae;Yoon, Junghee;Lee, Inhyung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.350-353
    • /
    • 2014
  • A 13-year-old, castrated male, Shih Tzu dog with a history of acute ataxia was referred to veterinary medical teaching hospital and anesthetized for diagnostic magnetic resonance imaging of cervical intervertebral disk disease. After preanesthetic evaluation including physical examination, blood chemistry, radiography and ultrasound, the patient was premedicated with intravenous butorphanol (0.2 mg/kg). Anesthesia was induced by intravenous propofol (6 mg/kg) and maintained with isoflurane at 1.2 minimal alveolar concentrations. Because the mean arterial pressure (MAP) decreased from 70 to 58 mmHg at 70 minutes after induction, dobutamine was administered by constant rate infusion ($5{\mu}g/kg/min$) to treat hypotension. However MAP did not increase, and heart rate rapidly decreased from 100 to 55 beats per minute (bpm). To treat bradycardia, intravenous glycopyrrolate ($5{\mu}g/kg$) was administered, and heart rate increased to 165 bpm. After extubation of endotracheal tube, the patient showed normal recovery without any problems related to cardiovascular system. Unexpected dobutamine-induced bradycardia was considered as Bezold-Jarisch reflex. It is recommended that clinicians know and prepare the possibility of bradycardia during dobutamine therapy under general anesthesia.