A Study on Mastitis Infection Rate and Investigation of Milk Contamination Level by Measuring the Bacteria and Somatic Cell Counts in Gyunggi Area (京畿一圓 乳牛의 乳房炎 感染率과 原乳의 細菌 및 體細胞數 測定에 따른 乳質 汚染度에 관한 연구)

  • Eu, Byung Woo
    • Journal of Environmental Health Sciences
    • /
    • v.11 no.2
    • /
    • pp.41-54
    • /
    • 1985
  • This study was conducted for the improvement of milk quality and milk hygiene in public health point of view. Investigation of mastiris infection rate, isolation and identification of causative microorganisms in CMT positive milk, investigation of milk contamination level by measuring the bacteria and soma tic cell counts and investigation of dairy management in farms were performed on 1.605 quarters milk of 434 cows of 20 dairy farms in Gyunggi-area from September 1983 to March 1984. The results were summarized as follows 1. Sixteen (3.7%) of 434 cows were found to be infected with clinical mastiris. 234 (53.9%) of 434 cows and 608(37.9%) of 1, 605 quarters were found to be infected with subclinical mastiris. 2. The causative microorganisms isolated were Staphylococcus aureus (38.3%), Staphylococcus epidermidis(21.0%), Micrococci(13.6%), Streptococcus spp. (12.3%), E. coli (7.4%), Fungus & Yeast (1.6%) and others (5.8%). 3. Total numbers of bacteria were $9.2{\times}10^6$ to $1.21{\times}10^7/ml$(av. $1.805{\times} 10^7/ml$), numbers of coliform bacteria were $4.1{\times} 10^5$ to $9.4{\times} 10^5$/ml(av. $7.05{\times} 10^5$/ml) and somatic cell counts were $4.8{\times} 10^5$ to $1.52{\times} 10^6$ cells/ml (av. $9.5{\times} 10^5$cells/ml) in bulk milk. 4. As comparing with CMT score of +, ++ and +++, somatic cell counts were $3.4{\times} 10^5$ to $1.64{\times} 10^6$ cells/ml (av. $6.41{\times} 10^5$cells/ml), $5.4{\times} 10^5$ to $2.75{\times} 10^6$ cells/ml(av. $1.762{\times} 10^6$cells/ml) and $1.97{\times} 10^6$ to $9.75{\times} 10^6$ cells/ml(av. $7.781{\times} 10^6$cells/ml), respectively. 5. In investigation on dairy management, performance of dry cow therapy, teat dipping after milking, disinfection of milking machine at every milking, replacement of milk liner within 6months and opportunity of acquirement for the mastiris control techniques by dairy education were 65%, 40%, 45%, 55% and 50% in 20 dairy farms, respectively.

  • PDF

Removal of Dissolved Organic Nitrogen from Surface Water and Reclaimed Water by Coagulation (지표수 및 재이용수내 용존 유기질소의 응집처리)

  • Lee, Wontae;Choi, June-Seok;Oh, Hyun Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.729-734
    • /
    • 2012
  • During chlorination processes dissolved organic nitrogen (DON) can form toxic nitrogenous disinfection byproducts and organic chloramines which have little or no bactericidal activity. DON needs to be removed before chlorination processes to reduce the formation of those products. This study investigated the removal of DON from surface water and reclaimed water by coagulation with aluminum sulfate (alum) and a cationic polymer (polyDADMAC). Removal characteristics of dissolved organic carbon (DOC) and ultraviolet absorbance at 254 nm ($UVA_{254}$) were compared with that of DON. Coagulation with alum removed DON, DOC, and $UVA_{254}$ with similar trends, but the removal of $UVA_{254}$ was highest. A dual coagulation strategy of alum and cationic polymer improved the removal of DON. Coagulation with cationic polymer alone was not effective due to its narrow range of charge neutralization. DON in reclaimed water was easier to remove than that in surface water, and higher molecular weight fraction (>10,000 Da) of DON was preferentially removed.

A Study on the Management of Micropollutants in Water System Considering Climate Change and other Potential Effects (기후변화 등 잠재적 영향을 고려한 수중 미량오염물질의 관리방향 연구)

  • Kim, Hojeong;Hong, Yongsuk;Ahn, Jong Ho
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.645-654
    • /
    • 2013
  • In this study, the management polices of micropollutants (MPs) were reviewed and the future management strategy was discussed considering climate change and etc. In Korea, the investigation of drinking water has been actively carried out for the priority contaminants as well as MPs. Recently river and lake waters have been also examined for MPs. However, the coverage and depth of the investigation is limited. Moreover, climate change is likely to increase air & water temperature and it will affect the hydrological cycle. Such changes may increase the residual concentrations of MPs in water system. As water reuse increases, the residual MPs of the recycled water may create public concerns. Thus, in a viewpoint of the precautionary principle, more stringent management of MPs is recommended for the drinking water and the body-contact water use. For the surface water, more studies are necessary to understand the ecological risk by MPs.

Effects of Sewage Effluent on Organic Matters of Nakdong River: Comparison of Daily Loading (낙동강 수계 내 하수처리 방류수가 하류 하천 유기물에 미치는 영향: 부하량 비교)

  • Seong, Jin-Uk;Park, Je-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.2
    • /
    • pp.210-217
    • /
    • 2012
  • This study investigated the water quality of effluents from the wastewater treatment plants, located at the Gumi Complex 4, Gumi, and Wonpyong, in Gumi. DOC accounted for higher than 70% of TOC, and oxidation efficiencies, calculated from carbon, were 13~43% for BOD and 37~73% for CODMn, respectively. Based on the biological decomposition experiments, R-DOC account for higher than 70% of DOC, mostly being occupied by refractory organic matters. This indicated that the biodegradable organics occupied more proportions of organic loadings than the refractory organics. The effect of the organics from a discharge of a sewage treatment plant on rivers, Gumi industrial Complex 4, Gumi, and Wonpyong on lower streams of the Nakdong River were found to be 15%, 6% and 16% respectively. The ratio of 15% suggests that comparatively, no large portions of TOC loadings are occupied, but the problem is that the biodegradable organic matters occupy a lot more proportions than that of the refractory organic matters. Thus, it is highly estimated that the refractory organics can gradually increase the pollution level of organics and precursors of disinfection by-products to the down-stream water treatment plants.

Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool (일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가)

  • Park, Hae-Dong;Park, Hyun-Hee;Shin, Jung-Ah;Kim, Tae-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.5
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

A Case Study on Chlorine Dioxide Usage at a Conventional Water Treatment Plant (기존 정수장 이산화염소 시범도입 사례연구)

  • Lee, Song-Hee;Lee, Byung-Doo;Kim, Jin-Keun;Seog, Kwon-Soo;Lee, Joung-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.115-119
    • /
    • 2005
  • As the regulations on DBPs are tightened, many water treatment plants (WTPs) in Korea have already introduced or will introduce enhanced coagulation, alternative disinfectants and advanced treatments such as ozonization and granular activated carbon to improve drinking water qualify. After a phenol leakage accident at the Nakdong-River in 1991, 26 WIPs in Korea introduced carbon dioxide generators, but there has been no accumulation of significant operating data. This research summarizes things that should be considered for the introduction of carbon dioxide disinfection process to WTPs based on one year operation data from A WTP that has had high concentration of DBP during a specific period in the summer. The removal efficiency of DBP was $30{\sim}40%$, but those of 2-MIB, Geosmin were less than 10%. The generation rate of $ClO_2$ by-products such as chlorite and chlorate were $70{\sim}100%$ of input dosage, but the ratios increased over time. At the same time, strong chlorine odors may be produced in the distribution system when $ClO_2$ was used with $Cl_2$ as a result of reaction between the chlorite and residual chlorine.

Development of a Hospital Foodservice Facility Plan and Model based on General Sanitation Standards and RACCP Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설모델 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.4
    • /
    • pp.477-492
    • /
    • 2003
  • The purposes of the study were to establish HACCP-based standards and guidelines for conducting a plan review to build, or renovate, hospital food service establishments, and ensure the safety of foodservice and reduce the risk of food borne illness. The scope of the study included suggestion for the planning of hospital foodservice facilities: layout, design, equipment and modeling. The results of this study can be summarized as follows: 1) The development of a foodservice facility plan based on the results of a survey, literature reviews and the results of interviews with foodservice managers from 9 general hospitals. This was composed of operational policies in foodservices, layout characteristics, space allocation, selection, design, specification standards for equipment and the construction principles of foodservice facilities. 2) Two foodservice facility models were developed, one for general hospitals with 900 beds (2,000 patients and 2,500 employee meals per day) and the other for general hospitals with 300 beds (600 patients and 650 employees meals per day). 3) The suggested kitchen space requirements for the foodservice facility models were 341.2 ㎡ (W 17,100mm x L 23,700mm) and 998.8㎡ (W 35,600mm x L 32,800mm) for the 300 and 900 beds hospitals, respectively, with both designs being rectangular. The space requirements for the equipment, in relation to the total operational area, in terms of ratios were 1:3.5 and 1:3.8 for the 300 and 900 beds hospitals, respectively. The recommended space allowances per bed for the developed foodservice facility models were 1.15 ㎡ and 1.11 ㎡ for the 300 and 900 beds hospitals, respectively, which were increased by more than 30% compared to those suggested in the precedent study, and considered appropriate for the implementation of the HACCP system. 4) The hospital foodservice facilities plans and models were developed based on the general sanitation standards, guidelines and the HACCP system, and included foodservice facility layout, product flow, physical separation between contaminated and sanitary areas, foodservice facility specifications with a 1/300 scale for a 300 bed, and a 1/400 scale for a 900 beds blueprint. 5) The main features of the developed foodservice facility plans and models were; physical separation between contaminated and sanitary areas to prevent cross contamination, product flow in one direction from the arrival of the raw material to the finished product, and separation of different work areas and the process of receiving & preparation of products, refrigeration & storage, cooking, assembly, cleaning & disinfection, employee areas and janitorial facilities. The proposed models from this study were presented as examples for those wanting to build, or renovate, their facility for the production of foods.

Removal Characteristics of Chlorination Disinfection By-Products by Activated Carbons (활성탄 공정에서의 염소 소독부산물 제거특성)

  • Son, Hee-Jong;Roh, Jae-Soon;Kim, Sang-Goo;Bae, Seog-Moon;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.762-770
    • /
    • 2005
  • Adsorption and biodegradation performance of chlorinated by-products such as trihalomethanes(THMs) and haloacetic acids(HAA5) on granular activated carbon were evaluated in this study. The coconut-based activated carbon was found more effective than others in adsorption of THMs due to larger pore volume of less than $20{\AA}$. The wood-based activated carbon was less effective than coconut- and coal-based activated carbon in adsorption nevertheless having larger pore volume and specific surface area than others. The maximum adsorption capacity(X/M) of coconut-based carbon for THMS was 1.1-1.5 times larger than coal based carbon and 14.1-31.4 times larger than wood based activated carbons. Activated carbon usage rate(CUR) of coconut-, coal- and wood-based activated carbons for chloroform were 9.4, 11.2 and 38 g/day respectively. In the evaluation of adsorption isotherm of THM species for coconut-, coal- and wood-based activated carbons, k value of chloroform was the lowest in the THM species, It menas that chloroform is difficult to remove by activated carbon adsorption. and BDCM, CDBM, bromoform are in the succeeding order of adsorption. In the evaluation of biodegradation rate, mean biodegradation rate was chloroform 7%, BDCM 5%, CDBM 4% and bromoform 3%, respectively THMs are difficult materials to be biodegraded. In the evaluation of characteristics of adsorption and biodegradation for HAA5 species, HAA5 species appear to be removed effectively by activated carbon. Most of the HAA5 are adsorbed at the beginning of operation periods and HAA5 except TCAA were almost biodegraded from bed volume of 2,000 and more than 90 percent of biodegradation of TCAA was started from bed volume around 4,000 and after that biodegradation rate was increased with increasing bed volume.

Characteristics of Chlorination Byproduct Formation of Synthetic Nitrogenous Compounds (합성유기질소 성분에서의 염소 소독부산물 생성 특성)

  • Son, Hee-Jong;Hwang, Young-Do;Roh, Jae-Soon;Bean, Jae-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.523-530
    • /
    • 2010
  • This study was conducted to analyze and determine formation potentials for chlorination disinfection by-products (DBPs) from 14 synthetic nitrogen compounds with or without $Br^-$. 5 of 14 compounds were 3-aminobenzoic acid, 2-aminophenol, aniline, anthranilic acid and 4-nitroaniline that were relatively shown high for formation of THMs/DOC whether or not $Br^-$ presented. 6 compounds that were p-nitrophenol, 3-aminobenzoic acid, 2-aminophenol, aniline, anthranilic acid and 4-nitroaniline were shown high for formation of haloacetic acids (HAAs)/DOC whether or not $Br^-$ presented. Trichloroacetic acid (TCAA) was dominated in 6 compounds. The formation of haloacetonitriles (HANs)/DOC whether or not $Br^-$ presented was high in 3-aminobenzoic acid, 2-aminophenol, aniline and anthranilic acid. Specially, aniline was detected 14.6∼16.1 ${\mu}g/mg$. The formation of chloral hydrate (CH)/DOC and chloropicrin (CP)/DOC were shown high in 3-aminobenzoic acid and 2-aminophenol in 14 compounds. 6 compounds (3-aminobenzoic acid, 2-aminophenol, aniline, anthranilic acid, 4-nitroaniline, p-nitrophenol) and a commercial humic acid were tested for the formation of DBPs/DOC whether or not $Br^-$ presented. When $Br^-$ was added, the DBPs/DOC was higher for the order of aniline> anthranilic acid> 3-aminobenzoic acid> 4-nitroaniline> humic acid> p-nitrophenol> 2-aminophenol. And when $Br^-$ was not added, the DBPs/DOC was higher for the order of anthranilic acid> aniline> p-nitrophenol> humic acid> 4-nitroaniline> 3-aminobenzoic acid> 2-aminophenol.

African Swine Fever Outbreak in North Korea and Cooperation between South and North Korea (북한지역에서 ASF발병 현황 및 남북수의협력에 관한 연구)

  • Cho, Chung Hui
    • Journal of Appropriate Technology
    • /
    • v.6 no.1
    • /
    • pp.21-27
    • /
    • 2020
  • The ASF, which originated in Africa and threatens the world, landed in Asia in 2018 in China, and became a stern threat to the security of the Korean Peninsula when North Korea officially reported the ASF to the OIE in May 2019. In 1921, Montgomery, a British veterinary pathologist, made headlines by naming the African swine fever "African Swine Fever," or ASF, a disease caused by a high fatality virus that existed in East Africa. The ASF, which was a pandemic of endemic diseases in Africa, landed in Portgal around 1957 and swept through farms in Lisbon, Portugal. The ASF continued to settle in Spain and Portugal, causing 40 years of damage until the end of the 1990s, and is now in progress after landing on the Italian island of Sardinia in 1978. The virus, which landed in Portiport of Georgia on the Black Sea coast of the Black Sea in 2007, spread to Russia and caused massive damage to China in 2018, then rapidly spread to Vietnam, Laos and Myanmar in May 2019 and spread across the country, causing massive damage to the pork industry and is now in progress. Just three months after confirming the outbreak in North Korea, the outbreak at farms in Paju and Yeoncheon was confirmed on Sept. 16, 2019, leaving South Korea with the stigma of ASF-causing countries, and although the ASF's nationwide expansion has been blocked, it is currently underway in wild boars. If the ongoing ASF in the two Koreas becomes indigenous, it would be a major disaster not only for the pork industry but also for the Korean Peninsula economy. Under the current circumstances, it is impossible to focus only on veterinary areas limited to South Korea, ruling out risk factors from the ASF outbreak. Currently, it is difficult to prevent damage to the pork industry due to the ASF outbreak due to the poor water defense reality in North Korea, and as it is adjacent to China, which has a high risk of developing various epidemic diseases, there is a need for the two Koreas to jointly conduct quarantine and quarantine on the border areas. First of all, I think rapid exchange of information and education on ASF and other diseases is necessary before establishing a joint defense system on the Korean Peninsula. It is important to conduct thorough quarantine and disinfection of ASF-generated areas in North Korea, and areas bordering China and Russia, and jointly conduct thorough quarantine and control of livestock and livestock products in circulation. Cooperation by the South and North Korean water defense industries to prevent the protracted ASF on the Korean Peninsula by all means and methods is essential.