• Title/Summary/Keyword: Disinfection

Search Result 961, Processing Time 0.024 seconds

Disinfection Models to Predict Inactivation of Artemia sp. via Physicochemical Treatment Processes (물리·화학적 처리공정을 이용한 Artemia sp. 불활성화 예측을 위한 소독 모델)

  • Zheng, Chang;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.421-432
    • /
    • 2017
  • In this study, we examined the suitability of ten disinfection models for predicting the inactivation of Artemia sp. via single or combined physical and chemical treatments. The effect of Hydraulic Retention Time (HRT) on the inactivation of Artemia sp. was examined experimentally. Disinfection models were fitted to the experimental data by using the GInaFiT plug-in for Microsoft Excel. The inactivation model were evaluated on the basis of RMSE (Root Mean Square Error), SSE (mean Sum Square Error) and $r^2$. An inactivation model with the lowest RMSE, SSE and $r^2$ close to 1 was considered the best. The Weibull+Tail model was found to be the most appropriate for predicting the inactivation of Artemia sp. via electrolytic treatment and electrolytic-ultrasonic combined treatment. The Log-linear+Tail model was the most appropriate for modeling inactivation via homogenization and combined electrolytic-homogenization treatment. The double Weibull disinfection model was the most suitable for the predicting inactivation via ultrasonic treatment.

Feasibility Study of UV Disinfection system of Small Wastewater System for Water Reclamation (용수 재이용을 위한 소규모 하수처리시설의 UV disinfection system)

  • Joung, Kwang-Wook;Yoon, Chun-Gyeong;Ham, Jong-Hwa
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.421-424
    • /
    • 2002
  • Deterministic and probabilistic approaches to the design of ultraviolet (UV) disinfection system for water reclamation are reviewed and discussed. The high inactivation of TC, FC and E. coli by UV disinfection was demonstrated and the inactivations of TC, FC and E. coli were 97%, 98% and 99%, respectively. Within the range of 0.3-4.5mWs/cm, the effect of UV does on the inactivation ratio was not observed. However, in the highest wattage of UV lamp, 39W, the inactivation ratio of TC, FC and E. coli was 100%, regardless of the UV does so the UV density was more effective on inactivation ratio of TC, FC and E. coli rather than UV does. Under the 0.4 mWs/cm and 16W of UV lamp, the effect of dissolved organic matter and turbidity on the inactivations of TC, FC and E. coli could not be observed in this study within the range of 0-60mg/L and 0-40 NTU respectively.

  • PDF

Application of Disinfection Models on the Plasma Process (플라즈마 공정에 대한 소독 모델 적용)

  • Back, Sang-Eun;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.695-704
    • /
    • 2012
  • The application of disinfection models on the plasma process was investigated. Nine empirical models were used to find an optimum model. The variation of parameters in model according to the operating conditions (first voltage, second voltage, air flow rate, pH) were investigated in order to explain the disinfection model. In this experiment, the DBD (dielectric barrier discharge) plasma reactor was used to inactivate Ralstonia Solanacearum which cause wilt in tomato plantation. Optimum disinfection models were chosen among the nine models by the application of statistical SSE (sum of squared error), RMSE (root mean sum of squared error), $r^2$ values on the experimental data using the GInaFiT software in Microsoft Excel. The optimum model was shown as Weibull+talil model followed by Log-linear+ Shoulder+Tail model. Two models were applied to the experimental data according to the variation of the operating conditions. In Weibull+talil model, Log10($N_o$), Log10($N_{res}$), ${\delta}$ and p values were examined. And in Log-linear+Shoulder+Tail model, the Log10($N_o$), Log10($N_{res}$), $k_{max}$, Sl values were calculated and examined.

Inactivation of Ralstonia Solanacearum using Filtration-Plasma Process (여과-Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.6
    • /
    • pp.1165-1173
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor in nutrient solution culture, a filtration-DBD (dielectric barrier discharge) plasma reactor was investigated for the Ralstonia solanacearum which causes bacterial wilt in aquiculture. The filtration-DBD plasma reactor system of this study was consisted of filter, plasma reactor, reservoir. The DBD plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the inactivation of R. solanacearum with filter media type in filter reactor ranked in the following order: anthracite > fiber ball > sand > ceramic ball > quartz ceramic. In filtration + plasma process, disinfection effect with the voltage was found to small. In disinfection time of 120 minutes, residual R. solanacearum concentration was 1.17 log (15 CFU/mL). When the continuous disinfection time was 120 minute, disinfection effect was thought to keep the four days. In sporadic operation mode of 30 minutes disinfection - 24 hours break, residual R. solanacearum concentration after five days was 0.3 log (2 CFU/mL). It is considered that most of R. solanacearum has been inactivated substantially.

A Study on the Microbiological Quality of Vegetables in Relation to the Sanitization Method Used and Vegetable Types (채소군별 미생물학적 안전성 확보를 위한 적정 소독방법)

  • Kim, Heh-Young;Lee, Yun-Hee
    • Korean journal of food and cookery science
    • /
    • v.25 no.5
    • /
    • pp.632-642
    • /
    • 2009
  • In this study the microbiological quality of vegetables was evaluated in relation to the sanitization methods used and vegetable types which consisted of raw food ingredients used in foodservice operations. We analyzed the microbial quantities on lettuce and spinach, which were used as leaf vegetables and cucumber and tomato, which were used as fruit vegetables according to various disinfection methods using different chlorine concentration(50 ppm, 100 ppm, 200 ppm) and exposure time(5 min, 10 min) over 5 days. When the effects of the disinfection methods on microbial qualities and sensory evaluation were analyzed, the following results were obtained. First, in the leaf vegetables, disinfection with a chlorine concentration of 200 ppm for a 5 minutes exposure time was needed to control microbial growth. Second, fruit vegetables sterilized with tap water had reduced microbial qualities after an extended amount of time relative to chlorine disinfection, that is, disinfection with a chlorine concentration of 50 ppm for 5 minutes exposure time was desirable.

Characteristics of the Disinfection Byproducts Formation in Electrolysis Disinfection of Drinking Water (음용수의 전기분해 소독과정에서의 소독부산물 생성특성)

  • Yun, Kyeong-Ae;Park, Sung-Bin;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.69-75
    • /
    • 2016
  • This study was conducted to examine the byproducts formation characteristics at the water treatment plants which applying electrolysis as a disinfection process in Gangwondo, Korea. Total of forty plants located in Gangwon Province, Korea were selected for the study. Correlation between dissolved organic carbon(DOC) and $SUVA_{254}$ was not clear. Among the species of the disinfection byproducts(DBPs), chlorate and trihalomethanes(THMs) accounted for 76% and 14% of DBPs, respectively. The effect of DOC or $SUVA_{254}$ on DBPs formation was not clearly demonstrated. The increased amount of THMs due to the raw water bromide content was found primarily in the form of chloroform, and the percent fraction of BDCM(bromodichloromethane) and DBCM(Dibromochloromethnae) was relatively insignificant. When the value of $SUVA_{254}$ was greater than $2L/mg{\cdot}m$, the percent fraction of BDCM and DBCM decreased while percent fraction of CF(chloroform) increased.

The pollutants removal and disinfection of secondary effluent from sewage treatment plant in loop reactor using silver nanoparticles coated on activated carbon (은나노 활성탄을 이용한 Loop Reactor에서 하수 2차 처리수 중의 오염물질 제거 및 소독 효과)

  • Seon, Yong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.4
    • /
    • pp.361-367
    • /
    • 2016
  • Pollutants removal and disinfection effect of secondary effluent from final settling tank of sewage treatment plant of W city were investigated in Loop Reactor using ordinary granular activated carbon(GAC) and GAC coated with silver nanoparticles. The results showed that the removal efficiency of $COD_{Mn}$, T-N and T-P using GAC with silver nanoparticles were higher than using the ordinary GAC. The removal efficiency of T-P using GAC with silver nanoparticles is 45.4% and that of T-P using ordinary GAC is 30.9% in the same case of the input amount of 20 g/L of GAC. The total califorms is reduced according to increasing input amount of GAC with silver nanoparticles and ordinary GAC. The disinfection efficiency of total coliforms in case of GAC with silver nanoparticles is much higher than that in case of ordinary GAC. For all experiments using the silver nanoparticles, the total coliforms is under 26 cfu/mL and this shows very excellent disinfection effect.

Design and Fabrication of a Ballast Water Treatment System Using UV Lamps (자외선램프를 이용한 선박평형수 처리시스템의 설계 및 제작)

  • Pyo, Tae-Sung;Cheon, Sang-Gyu;Park, Dae-Won;Choi, Sung-Kuk;Kim, Seong-Yeon;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.952-958
    • /
    • 2009
  • The International Maritime Organization (IMO) has adopted the ballast water management convention at a diplomatic conference in early 2004 that all ships should be equipped with a treatment system from 2010 gradually. In this paper, the disinfection characteristic of ultra-violet (UV) rays was studied and a ballast water treatment system (BWTS) which can treat $50m^3$/h sea water was manufactured. The system consists of a disinfection chamber with six 3.5 kW UV lamps which are operated by magnetic ballasts, a programmable logic controller (PLC) and set of pipe lines. The biological disinfection efficacy of the prototype BWTS was evaluated following the IMO rules using zooplankton such as Artemia and Rotifer species for the size over $50{\mu}m$, and phytoplankton such as Tetraselmis and Thalassiosira species for the size between 10 to $50{\mu}m$. From the experimental results, the disinfection efficacy was 99.99 % that meets the IMO requirement. However, more studies on an energy saving system are needed because the consumption power of the prototype system is as high as over 21 kWh for $50m^3$/h.

Simulation for the Flowing Water Purification with Spring Shape Inside Chamber (챔버 내측에 스프링형상을 갖는 유수형 자외선 살균장치 시뮬레이션)

  • Jung, Byung-Gyeon;Jeong, Byeong-Ho;Lee, Jin-Jong;Jung, Byeong-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.411-416
    • /
    • 2010
  • Interest in application of ultraviolet light technology for primary disinfection of potable water in drinking water treatment plants has increased significantly in recent years. The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics(CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. In this paper, It describe the how to design optimal UV disinfection device for ground water, BWT and rainwater. Spring shape instrument silver coated located in inner side of disinfection chamber. It make lead the active flowing movement target water and maximize disinfection performance. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method, performed simulation and proved satisfied performance.

Formation Characteristics of Disinfection By-Products using Chlorine Disinfection in Sewage Effluent (하수 염소 소독시 소독부산물 발생 특성)

  • Beck, Young-Seog;Song, Min-Hyung;Jung, Kyung-Hun;Kwon, Dong-Sik;Lee, Gi-Gong
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.275-280
    • /
    • 2004
  • This study was performed to investigate the disinfection efficiency and the formation characteristics of disinfection by-products(DBPs) by chlorination in the sewage effluent. The effluent was sampled from the sewage treatment plants operated in the activated sludge process and the advanced sewage process. The type of DBPs investigated were Trihalomethanes(THMs), Dichloroacetonitrile(DCAN), Chloral hydrate(CH), Dichloroacetic acid(DCAA), Trichloroacetic acid(TCAA). Major findings are as follows. First, the optimum injection concentration for chlorination in sewage effluent were found to be in the range $0.5{\sim}1.0mg\;cl_2/L$. Also, It was found that the chlorine dosage in the effluent of activated sludge process was higher than in the effluent of advanced sewage process. Second, the maximum formation concentration of THMs were $12.7{\mu}g/L$. The THMs formation reaction was finished in a short time of several seconds and chloroform was mainly formed. Also, it was found that the concentration of ammonium nitrogen is higher, the concentration of THMs is lower. Third, it was found that DCAA and TCAA were mainly formed as DBPs by disinfection.