• Title/Summary/Keyword: Discharging

Search Result 1,168, Processing Time 0.025 seconds

AC Regeneratable Battery Charging and Discharging Test System (AC 회생이 가능한 배터리 충·방전 테스트 시스템)

  • Kim, Jun-Gu;Youn, Sun-Jae;Kim, Jae-Hyung;Won, Chung-Yuen;Na, Jong-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.99-106
    • /
    • 2012
  • In this paper, 15[kW] AC regenerative system for battery charging and discharging test is proposed. The regenerative system is able to regenerate surplus energy to the grid in discharging mode, and the inverter of the system can be operated as a converter to compensate scarce energy in charging mode. In case of the conventional DC charging and discharging system, the regenerative energy is consumed by a resistor. However, as the proposed system regenerates the surplus energy to the grid through using DC-AC inverter, the energy saving effect can be achieved. In this paper, 15[kW] battery charging and discharging system is developed, and the validity of the system is verified through simulation and experimental results.

A Study on the Change of Water Quality in the Vicinity of Mokpo Harbor Due to the Discharges from Yongsan River Estuary Weir and Yongam-Kumho Sea Dike (영산강 하구둑과 영암-금호방조제 방류에 의한 목포항 주변 수역의 수질변화에 관한 연구)

  • 정대득;이중우;국승기
    • Journal of Korean Port Research
    • /
    • v.13 no.2
    • /
    • pp.419-426
    • /
    • 1999
  • It is essential for port planning, coastal zone management and environmental impact study to analyze the variation of current and water quality due to the development of water area and discharged water from estuary barrage and basin etc. Mokpo sea area downstreams from a long river and two large basins, the Yongsan river and Yongam-Kumho basins discharging much of water through water gates for the purpose of flood control and prohibition of salt intrusion to the inland fresh water area. In this study, the numerical calculations were carried out for the analysis of diffusion characteristics due to discharging operation, adapting the results of tidal current simulation ADI methord is applied to the governing equation for the movement of sea water and diffusion and 6-point method to the advection terms of diffusion equation. As the results of this study, it is known that the discharging operation causes increasing and/or decreasing of current velocity and enlarging and/or depressing of pollutant diffusion limits depending on the distance from the discharging gates and the mode of discharging operation. To utilize these result, the linked gate operation and the method increasing exchange of sea water must be considered.

  • PDF

A Study on the Charge of Water Quality in the Vicinity of Mokpo Harbor due to the Discharges from Yongsan River Estuary Weir and Yongam-Kumho Sea Dike (영산강 하구둑과 영얌-금호방조제 방류에 의한 목포항 주변 수역의 수질변화에 관한 연구)

  • 정대득;이중우;국승기
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.253-261
    • /
    • 1999
  • It is essential for port planning, coastal zone management and environmental impact study to analyze the variation of current and water quality due to the development of water area and discharged water from the estuary barrage and basin, etc. Mokpo sea area has downstream from a long river and two large basins, the Yongsan river and Yongam-Kumho basins, discharging much of water through water gates for the purpose of flood and prohibition of salt intrusion to the inland fresh water area. In this study, the numerical calculation were carried out for the analysis of diffusion characteristics due to discharging operation, adopting the results of tidal current simulation. ADI method is applied to the governing equation for the movement of sea water and diffusion and 6-point method to the advection terms of diffusion equation. As the results of this study, it is known that the discharging operation causes increasing and/or decreasing of current velocity and enlarging and/or depressing of pollutant diffusion limits depending on the distance from the discharging gates and the modes of discharging operation. To utilize these result, the linked gate operation and the method increasing exchange of sea water must be considered.

A Study on the Silk Printing with Reactive Dye. (반응성 염료에 의한 견날염에 관한 연구(단보) I. 백색발염에 대하여)

  • 정인모;이용우
    • Journal of Sericultural and Entomological Science
    • /
    • v.32 no.2
    • /
    • pp.110-112
    • /
    • 1990
  • The influence of the concetration of the discharging agent on some properties of silk fabric dyed with reactive dyes studied. The tensile strength, yellow index and whiteness were investigated as parameters to determine the effect of the dischanging agent. The results were summarized as follows ; 1. The tensile strength and the yellow index decreased with the increase of the concentration of the discharging agents. 2. The whiteness depended on both of the type and the concentration of the discharging agent.

  • PDF

The Characteristics of Discharging signal in various kinds of insulation oil using Optical Fiber Sensor (광섬유 센서로 측정한 절연유에 따른 방전신호 특성)

  • Kim, Tae-Young;Nam, Jin-Ho;Suh, Kwang-S.;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1599-1601
    • /
    • 1999
  • The characteristics of ultrasonic signal in insulation oil were investigated by optical fiber sensor(OFS) utilizing Mach-Zehnder interferometer. For checking the response properties of OFS ultrasonic signal was generated by function generator in various kinds of insulation oil. The attenuation of ultrasonic signal linearly increased with the increase of viscosity of insulation oil in log scale. Discharging signal was produced by neele-sphere electrode system. Intensity of discharging signal was plotted in terms of cumulative $y^2$ and the intensity of discharging signal in new oil was little bigger than that in serviced one.

  • PDF

Energy Storage Characteristics In Fixed Beds (Charging, Storing, Discharging)

  • Hassanein, Soubhi A.;Choi, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.17-23
    • /
    • 2004
  • In the present work, the numerical model was refined to predict the thermal analysis of energy storage in a fixed beds during (charging ,storing, discharging) mode. The governing energy equations of both fluid and the solid particles along with their initial and boundary conditions are derived using a two-phase, one dimensional model. The refined model is carried out by taking into account change of (air density , air specific heat) with air temperature and also by taking into considerations heat losses from bed to surrounding. Finite difference method was used to obtain solution of two governing energy equations of both fluid and solid particles through a computer program especially constructed for this purpose. The temperature field for the air and the solid are obtained, also efficiency of energy stored inside the bed is computed. Finally using refined model the effect of air flow rate per unit area Ga (0.2, 0.3, and 0.4 kg/$m^2$-s), and inlet air temperature (200, 250, 300 $^{\circ}C$) on energy storage characteristics was studied in three mode ( charging ,storing, discharging). The rock particles of diameter 1 em is used as bed material in this research.

  • PDF

Design of a cycler system for large capacity lithium-polymer battery (중대형 리튬폴리머 2차전지용 충방전기 개발)

  • Oh Dong-Seob;Oh Sung-Up;Lee Jong-Yun;Park Min-Ho;Seong Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.82-86
    • /
    • 2004
  • In this paper, a cycler system for the Lithium-Polymer battery with the large capacity of 120Ah is presented. This system is constituted as the two units for the charging and discharging. The Lithium-Polymer battery should be charged in CC and CV mode, and it is required a very high precision control of the voltage and current for the charging unit. To decrease the switching noises and harmonics, parallel operation method is adopted and utilized in the power conversion module. The discharging unit has a link AC system function to return the discharging energy of battery to AC line and has comparatively less thermal loss. These units are designed to be controlled and monitored by personal computer. The total system for the battery charging and discharging is described and presented.

  • PDF

Charging and Discharging Characteristics of Electric Double Layer Capacitors used for a Storage Battery of Solar Energy

  • Sung, Youl-Moon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.97-102
    • /
    • 2007
  • The charging/discharging characteristics of electric double layer capacitors (EDLCs) for an electric power storage device application were investigated. The specific area of the carbonaceous electrode surface by the BET method was in the range of $1800{\sim}2000\;m^2/g$. The charge distributions during charging and discharging were measured by means of a pulsed-electro-acoustic (PEA) method, and the voltage characteristics of EDLCs connected to solar cells were evaluated. The results showed that the distributions of positive and negative charges were spatially uneven, which was due to the mobility of the positive and negative charges in the carbonaceous electrode surface of the EDLCs. The charge accumulation region concentrated on central part of the carbonaceous electrode and the required times for charging and discharging were almost same.

Initial Flow Characteristics of the Turbulent Circular Jet Discharging into the Sudden Expansion Pipe (축대칭 급확대관으로 분사되는 난류분사류의 초기유동 특성)

  • 김동식;한용운
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3335-3344
    • /
    • 1994
  • The initial flow characteristics of the turbulent circular jet discharging into the sudden expansion pipes have been investigated by the hot wire anemometry. Evolutions of similarity, centerline behavior, jet boundary and typical turbulent quantities were looked into for the expansion ratios. The results show that the spreading rates of discharging jet seem not to be dependent of the expansion ratio and that the velocity profiles in the radial directions exhibit the similarity in the regions, 2-5d, 2-6d and 3-8d for the corresponding expansion rations of 2, 3 and 5, respectively. With the increase of expansion ratio the centerline velocity decays rather slowly. The anisotropic behaviors of the discharging jets into the sudden expansion pipe look stronger than those of the free jet.

Electric Degraded Properties of EP Cable Rubber (EP 케이블 고무의 전기적 열화 특성)

  • Lee, Sung-Ill;Bae, Duck-Kweon;Kim, Sang-Hyeon;Lee, Jong-Pil;Oh, Yong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.516-517
    • /
    • 2008
  • The ethylene-propylene (EP) rubbers mixed with one to one ratio is used as an insulation material in the nuclear power plant. It was investigated the effect of the amount of reinforcing agent. moisture absorption and heat treatment on the Ethylene-Propylene(EP) rubbers. The level of degradation was measured by the amount of discharging and. charging currents. When $\gamma$ rays were radiated on the EP rubbers with more charging material, the amount of discharging and charging currents was depended on the amount of reinforcing agent It was verified that the discharging and charging currents irradiated by $\gamma$ rays were higher than those that was not irradiated.

  • PDF