• 제목/요약/키워드: Discharge time

검색결과 2,603건 처리시간 0.033초

A New Driving Scheme for Reduction of Addressing time and its Dispersion in AC PDP

  • Lee, Sung-Hyun;Kim, Dong-Hyun;Park, Cha-Soo;Park, Chung-Hoo;Ryu, Jae-Hwa
    • Journal of Information Display
    • /
    • 제2권2호
    • /
    • pp.39-44
    • /
    • 2001
  • The conditions of the wall charges and priming particles in a unit discharge cell in AC PDP seriously affect the addressing discharge characteristics in the driving method with ramped setup pulse. Moreover, the discharge conditions at the end of the scan line may be different from the first scan line because of the difference of about 1ms address time. Consequently, the addressing time and its dispersion may be different for any two discharge cells that lead to misfiring and the increase in the total addressing time. In order to improve the addressing time and its dispersion, we have applied different addressing voltage at each cell such as progressively increase pulse voltage instead of constant one. As a result, the addressing time and its dispersion of all cells were improved by about 30% compared with the conventional driving method.

  • PDF

Sputter etching에 의한 PET직물의 심색성 향상 (Increase in Color Depth of Black Dyed PET Fabrics Treated by Sputter Etching)

  • Shim, Yu Bong;Lee, Mun Cheul
    • 한국염색가공학회지
    • /
    • 제9권1호
    • /
    • pp.15-22
    • /
    • 1997
  • The alkali treated and black dyed PET fabrics were sputter etched under Ar gas atmosphere. The color depth of PET fabrics were increased with sputter etching time only under some limits of discharge power. And above that limits of discharge power the color depth of PET fabrics was decreased by increasing discharge power and treatment time. Minute cracks were made by sputter etching in the whole surface of fabrics to the direction of perpendicular to the longitudinal side of yarns. The fineness and density of minute crack were increased with lowering discharge power. And the size of crack was far smaller than that of microcrater which was obtained by alkali treatment. It is considered that the increase of color depth is related to the minute crack. The water permeation time of sputter etched fabrics was increased with increasing discharge power and treating time. The increase of color depth attained by sputter etching was fully kept through repeated laundering.

  • PDF

Discharge characteristics of MgO-PDP manufactured by using "all-in-vacuum" process

  • Yano, T.;Uchida, G.;Uchida, K.;Awaji, N.;Shinoda, T.;Kajiyama, H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.28-30
    • /
    • 2009
  • PDP panels with MgO protective layer are manufactured by using the "all-in-vacuum" process we have established [1]. This is the process aiming to keep the MgO surface as clean as possible after the evaporation. The panels are evaluated in term of discharge voltage, aging time, luminance, luminous efficacy, discharge time-lag. It is confirmed that the "all-in-vacuum" process particularly improves the aging time, discharge voltage and the discharge time-lag.

  • PDF

직류 코로나 하전된 강유전체구 층의 연면방전특성 (Surface Discharge Characteristics of a DC Corona Charged Ferroelectric Pellet Barrier)

  • 금상택;이근택;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.385-390
    • /
    • 1999
  • Surface corona discharge characteristics of a dc corona charged ferroelectric pellet barrier have been investigated experimentally. Electric charges stored on the surfaces of the ferroelectric pellets by a dc corona discharge provide partial electric fields on the surfaces of the ferroelectric pellets, which could generate surface corona discharges on the ferroelectric pellets. This system utilizes both the surface discharges on the ferroelectric pellet barrier and the corona discharge between corona tip and mesh electrode. Positive and negative dc voltages were applied to the tip to generate partial discharges, and corona currents were estimated to investigate the buildup charge on ferroelectric pellets as a function of the applied time and the charge relaxation time constants of ferroelectric pellets. As a result, in the case of the negative corona discharge with the ferroelectric pellet barrier, the mean corona current and ozone generation increase greatly, and the surface discharges on the ferroelectric pellets can be fenerated efficiently. It is also found that, charge relaxation time, dielectric constants offerroelectric pellets, polarity of applied voltage and applied time affected to the surface discharges among the ferroelectric pellets.

  • PDF

LabVIEW 소프트웨어 패키지를 이용한 고압나트륨전등의 교환시점 및 수명진단 알고리듬 (The Algorithm of Life Time Diagnostics end Evaluating of Exchanges Time about High Pressure Sodium Vapor Lamp Using the LabVIEW Software Package)

  • 한태환
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.1-7
    • /
    • 2004
  • 고압방전등을 점등하기 위해서는 고전압의 시동전압이 필요하게 되는데, 이러한 시동전압은 고압력의 나트륨램프에서도 필요하게 된다. 자기장은 전기 방전튜브에서 만들어지게 되며 증기 원자에 대한 전자충돌이 가속화되면서 2차 전자가 발생하고 전기 방전튜브에 전류가 급속도로 흐르게 되며, 나트륨램프의 제작회사마다. 서로 다른 램프의 수명 및 교환시점도 서로 다르다는 것을 본 논문의 연구과정에서 발견하게 되었다. 본 논문에서는 LabVIEW소프트웨어패키지를 사용 중인 나트륨램프의 교환시점의 알고리듬을 제안한다.

미세 방전 가공에서 방전 면적과 축전 용량에 따른 가공율 특성 (Characteristics of Material Removal Rate According to Discharge Area and Capacitance in MEDM)

  • 박동희;류시형;김보현;주종남
    • 한국정밀공학회지
    • /
    • 제20권12호
    • /
    • pp.183-190
    • /
    • 2003
  • In this paper, investigated are the machining characteristics such as material removal rate and machining time with respect to discharge area and capacitance in micro electrical discharge machining (MEDM). As discharge area determined by the electrode size and capacitance change, the optimal feedrate to allow the minimum machining time changes. The smaller discharge area is, the lower MRR becomes because of the area effect. As the capacitance increases, MRR also increases. However there is the limit capacitance beyond which the MRR does not increase anymore. As the discharge area increases, the limit capacitance also increases.

미계측 지점에서의 유출 모의 및 예측 (Runoff Simulation and Forecasting at Ungaged Station)

  • 안상진;최병만;연인성;곽현구
    • 한국수자원학회논문집
    • /
    • 제38권6호
    • /
    • pp.485-494
    • /
    • 2005
  • 유량과 수질의 관계를 분석하는 것은 매우 중요하다. 하천의 실시간적 관리를 위해서는 유량과 수질의 측정이 동일한 지점에서 동시간적으로 이루어져야 보다 효과적이다. 그러나 수질자동측정망 지점과 T/M 수위관측소가 원거리에 위치한 경우들이 있으며, 평창강 수질자동측정망 지점이 그 중 하나이다. 이러한 지점에서는 보다 정확한 유량 산정과 이를 활용한 예측 프로그램이나 시스템이 요구된다. 이번 연구에서는 미계측 지점인 평창강 수질자동측정망 지점에 유량예측 신경망 모형을 적용하고, 적용성을 검토하기 위해 WMS 모형의 모의결과와 비교하였다. WMS 모형은 첨두유량이 작고, 수문곡선이 단조로운 사상에 적합한 것으로 나타났다. 신경망 모형의 유출량 예측값은 비유량과 WMS 모형의 모의값에 근사하였으며, 미계측 지점에서의 유출량 변화성향을 잘 반영하는 것으로 나타났다.

Correlations between Cognitive Function and Functional Ability in Strokes using MMSE and FIM

  • Kim, Eun-Joo
    • International Journal of Contents
    • /
    • 제5권3호
    • /
    • pp.86-90
    • /
    • 2009
  • The Purpose of this study was to investigate correlations between the Mini-Mental State Examination (MMSE) and the Functional Independence Measure (FIM) in strokes. The data collected retrospectively from fifty-five stroke rehabilitation patients. The MMSE and FIM at the time of admission and discharge were obtained from patients' medical records. Firstly, Pearson correlation coefficients of the MMSE score at the time of admission revealed $0.286{\sim}0.747$ with FIM at the time of discharge (p<0.05). Also, the change of MMSE score significantly correlated with the change of total FIM scores in strokes (r=0.409, p<0.05). Because the MMSE scores at the time of admission and FIM at the time of discharge are correlated, the MMSE scores can be used to predict the FIM at the time of discharge and establish a rehabilitation program.

구리전극봉을 이용한 합금공구강재(STD11)의 비관통 방전 탭 가공에 관한 연구 (A Study on the Electrical Discharge Blind Hole Tap Machining of STD11 with Copper Electrode)

  • 박인수;왕덕현;김기태
    • 한국기계가공학회지
    • /
    • 제16권3호
    • /
    • pp.38-44
    • /
    • 2017
  • The technology of electrical discharge tap machining may be appropriate for making thread out of highly brittle material. Especially, it is very difficult to machine tap with the traditional method if the brittle material has been hardened by quenching. In this study, the shape of electrical discharge blind hole tap machining was analyzed by discharge time, discharge current, and the flushing hole condition after quenched the tool steel of STD11 has discharged the tap shape with a screw-shaped copper(Cu) electrode. An experimental design was planned and analyzed by Taguchi robust experimental design. The result showed that the shape of the blind hole discharge tap was influenced by the flushing hole, discharge time, and discharge current. The most important factor of the processing conditions was found to be the discharge current. When blind hole EDM with a copper electrode with a flushing hole was conducted, the discharged shape was found to be smooth and the angle of the discharged tapped thread was also found to be close to the thread angle of $60^{\circ}$. As the values of discharge time and discharge current increased, the EDMed surface coarsened due to the increase of the single discharge energy and the shape of the thread collapsing.

수평배수재의 통수특성에 관한 연구 (A Study on the Characteristics of Discharge Capacity for Horizontal Drains)

  • 박정용;박정순;장연수;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.557-564
    • /
    • 2002
  • Discharge capacity test is carried out to find out influencing factors on discharge capacity of prefabricated horizontal drains to improve weak dredged clay. Four representative prefabricated horizontal drains are selected based on the size of drain as well as the shape of core. Test is carried out for 10 days at each three level of confining pressure for all drains. Effects of elapsed time, confining pressure, hydraulic gradient and strength of filter and core on discharge capacities are examined. It is found that discharge capacity of drain, which has deformable core or has a possibility of squeezing filter into core, decreases more with time due to its low strength. As confining pressure increases, discharge capacity decreases due to the squeezing of filter into core.

  • PDF