A Study on the Characteristics of Discharge Capacity for Horizontal Drains

수평배수재의 통수특성에 관한 연구

  • 박정용 (동국대학교 토목환경공학과) ;
  • 박정순 (동국대학교 토목환경공학과) ;
  • 장연수 (동국대학교 토목환경공학과) ;
  • 김수삼 (한양대학교 토목환경공학과)
  • Published : 2002.03.01

Abstract

Discharge capacity test is carried out to find out influencing factors on discharge capacity of prefabricated horizontal drains to improve weak dredged clay. Four representative prefabricated horizontal drains are selected based on the size of drain as well as the shape of core. Test is carried out for 10 days at each three level of confining pressure for all drains. Effects of elapsed time, confining pressure, hydraulic gradient and strength of filter and core on discharge capacities are examined. It is found that discharge capacity of drain, which has deformable core or has a possibility of squeezing filter into core, decreases more with time due to its low strength. As confining pressure increases, discharge capacity decreases due to the squeezing of filter into core.

Keywords