• 제목/요약/키워드: Discharge time

검색결과 2,624건 처리시간 0.038초

고압 아아크 방전시스템의 각종 특성 해석에 관한 연구 (A Study on the Analysis of Various Characteristics for the High Pressure are Discharge System)

  • 지철근;박왕열;이진우
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제5권4호
    • /
    • pp.35-42
    • /
    • 1991
  • Recently, HID lamps have been considered as important in regard to the trend of energy saving, and increasingly and diversely used in various ways. This paper will show the simulating models concerning high-pressure arc discharge system directly applicable for its design and manufacture, and analyze its various characteristics. For warm-up characteristics, the evaporating process of inner atoms is described in terms of second-order differential equation: for the thermal conduction from are axis to discharge wall and outer bulb, its transfer process is introduced according to five first-order differential equations. Under the steady state satisfying LTE, the time-variant characteristics are suggested by means of time-dependent energy balance equation derived from fluid equations, approximation of radiation energy and material functions in the discharge tube. The simulating models concerning these equations are then applied for high-pressure mercury lamp.

  • PDF

낙동강 하구해역의 식물플랑크톤 극대역 변동에 관한 수직시뮬레이션 -I. 식물플랑크톤 극대역 변동 현황- (The numerical simulation on variation of phytoplankton maximum region in the estuary of Nakdong river -I. The state of variation of phytoplankton maximum region-)

  • 이대인
    • 한국환경과학회지
    • /
    • 제9권5호
    • /
    • pp.369-374
    • /
    • 2000
  • The estuary of Nakdong river is very influenced by the freshwater contained nutrients and organic materials. The response results of these influences are eutrophication and red tide outbreak in this region. Concentration of chlorophyll a was 0.78~62.55$\mu\textrm{g}$/L in February 1.20~21.29$\mu\textrm{g}$/L in April 1.88~188.35$\mu\textrm{g}$/L in June and 0.78~11.21$\mu\textrm{g}$/L in August respectively. The decrease of chlorophyll a is considered that residence time is shorten by increase of freshwater discharge and unfavorable growth condition of phytoplankton is created by diffusion of low salinity and increase of turbidity. The phytoplankton maximum region located inner side of this estuary during winter season whereas it was moved to outer side when mean discharge of the Nakdong risver was increased, Therefore the variation of phytoplankton maximum region was affected by input discharge from the Nakdong river basin.

  • PDF

Mica/Epoxy 복합 절연계통의 부분방전 특성과 열화 관계에 관한 연구(I) (A Study on the Relationship between Aging and Partial Discharge Characteristics of the Mica/Epoxy Composite Insulation Systems (l))

  • 강동식;이우영;박정후;곽영순;김길용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.976-979
    • /
    • 1992
  • There are lots of problem which are delaminations and partial discharge of insulation materials in high-voltage rotating machines caused by mechanical, electrical and thermal aging. Several experiments have been aiming at finding the useful diagnostic parameters from the partial discharge characteristics by applying a new measurement techniques. This paper deals with the partial discharge characteristics (pulse height, pulse angle, pulse frequency spectrum and time interval), which may be a useful diagnostic concept in predicting insulation condition of mica/epoxy composite insulation materials, by using several measurement equipments (frequency spectrum analyzer. multichannel analyzer and time interval analyzer).

  • PDF

SWT(Stationary Wavelet Transform)를 이용한 몰드변압기 방전 측정신호의 디노이징 특성 연구 (A Study on the Comparison of Denoising Performance of Stationary Wavelet Transform for Discharge Signal Data in Cast-resin Transformer)

  • 최명일;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.84-90
    • /
    • 2014
  • The partial discharge of Cast-resin Transformer has a difficulty to be analyzed, because it is an abnormal condition signal of which stochastic characteristics varies with time variance. In this study, background noise coming from the outside of the cast-resin transformers through ground wire can be removed and only a discharge signal of which defects are simulated can be obtained, using the wavelet transform method, which is a time-frequency domain analysis technique. As a result, it was confirmed that de-noising using the SWT technique is the best efficient among three methods of the wavelet transform techniques.

부분방전 특성을 이용한 고압 유도전동기 고정자 권선 열화진단 (Oeterioration Diagnosis of Stator Windings in High Voltage Induction Motor Using Partial Discharge Characteristics)

  • 김덕근;정영일;이은석;임용배;김종서
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.481-484
    • /
    • 2001
  • High voltage induction motors are widely used in industrial factory because have many benefits. But the insulated materials of induction motor are aged by using time, electrical, thermal, circumstantial stresses and so on. Motor failures are occurred by these deterioration phenomena and give rise economic problems to user. In many motor failures, insulated material problems of stator winding happen frequently and occupy high percentages in the failure source. In this paper, the testing specimen(motorette) is manufactured by modeling of stator winding of high voltage induction motor and accelerating test is carried out. Partial discharge signals detected by RF sensor are used to analyze deterioration condition of stator windings. According to aging time, the 3D ( ${\Phi}$-Q-N) distribution and skewness of partial discharge signals are changed.

  • PDF

마이카-에폭시 복합절연계 계면층의 부분방전 특성에 관한 연구 (A Study on Partial Discharge Propeties of Interface Layer in-Mica-Epoxy Composite Material)

  • 이은학;김태성;박종건;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1991년도 추계학술대회 논문집
    • /
    • pp.83-89
    • /
    • 1991
  • The partial discharge properties of interface layer in Mica-Epoxy composite, which has been mainly used for the coil insulating material of high voltage machinery, are different from those of resins due to the abnormal interface layer to be presented between inorganic material and resin. Accordingly, the study on discharge of interface in composite insulting system is strongly requsted for not only an increasing of insulating strength, but also the basical information of diagnosis system for high voltage equipment. As a result, it has been confirmed that the interface is an abnormal resin layer and the contact states at interface is depended upon the density of silane aqueous solution. Pulse frequency at abnormal interface shows a linear increasing with enlargement of discharge quantity. Whereas, in case of normal interface, pulse frequency property represents exponential increasing at the point of saturating. A life model can be diagramed from results of time dependance of skewness, and a survival life time can be quantified from the life model suggested.

침출수 무배출식 모형매립조를 이용한 도시폐기물 분해특성 (Decomposition Characteristics of Municipal Solid Wastes in Lysimeter Without Leachate Discharge)

  • 류돈식;이해승;이찬기
    • 환경위생공학
    • /
    • 제15권2호
    • /
    • pp.49-57
    • /
    • 2000
  • The objective of this study is to find solid waste decomposition in landfill without leachate discharge. This study was observed variation of landfill gas production rate and leachate for stabilization assessment, and using four sets of lysimeter as experimental apparatus. Soild waste decomposition was accelerated in without leachate discharge system by sufficient moisture for methane bacteria. And gas production rate was between 54.2ℓ/kg VS∼335.9ℓ/kg VS in each lysimeter. Generation time of methane gas was showed different in each lysimeter, but it was much faster than literature research. The time of stabilization phase were began as follows : L-1 400 day, L-2 350 day, L-3 170 day and L-4 70 day respectively. Decreasing times of BOD/COD ratio and C/N ratio were necessary more than literature research because organic matter was not discharge such as wash out.

  • PDF

코로나방전선 표면 산화에 따른 오존발생량의 경시특성 (Time Dependant Ozone Generation due to Oxidation of the Surface of Corona Discharge Wires)

  • 정성진;박승록;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.22-25
    • /
    • 2000
  • Time dependent ozone generation characteristics of some oxide layers grown by ozone on the surface of corona discharge wires have been investigated experimentally in air ambience. Four wires of stainless steel, iron, silver and copper were used for the corona discharge wire of an ozone generator. And the effect of the metal oxide layers on ozone generation was studied and the contamination morphology of each layers was characterized. With the SEM images and the EDS spectra, it was found that all the surface of the corona wire were oxidized by the generated ozone and contaminated by airborne particles through the gradient force. As a result, the morphology and the electrical property of metal oxide layer grown on corona wire surface influenced on ozone generation characteristics i.e. discharge mechanisms.

  • PDF

가교폴리에틸렌(XLPE)의 부분방전에 의한 초음파 검출 (Detection of Ultrasonic Wave Signals Associated with Partial Discharge in XLPE)

  • 김성규;이상우;구경철;김충년;김인식;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.136-140
    • /
    • 1999
  • Measurements of AE signals caused by partial discharges were performed by using an ultrasonic measurement technique to diagonise the electrical treeing deterioration in XLPE cable. We also examined the partial discharge magnitude and AE signals(peak-to-peak) with the increase of the deterioration time. From these results, it was found that AE signal due to partial discharge can be greatly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of AE signals was closely related to the current pulses by the increase of deterioration, and it appeared that AE signals(peak-to-peak) was proportional to partial discharge magnitude. Attenuation and time-delaying characteristics of ultrasonic signals propagated in various polymers sample by using ultrasonic oscillation and receiving systems are also reported as a basic data of ultrasonic measurements in XLPE cable.

  • PDF

A new ramp reset waveform for reducing reset period using address pulse of AC-PDP

  • Kim, Gun-Su;Choi, Hoon-Young;Lee, Seok-Hyun;Kim, Jun-Hyoung;Mim, Byoung-Kuk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.609-612
    • /
    • 2002
  • A new reset waveform is proposed for reducing the reset period. A square pulse is applied to the address electrode while reset pulse ramps and before a discharge between the sustain electrodes occurs. The square pulse induces a discharge between the address electrode and the X electrode, and the induced wall charge is opposite to the applied ramp pulse. Thus, the next discharge between the sustain electrodes becomes weaker. The weaker discharge lowers background luminance and improves contrast ratio. Thus, the new reset waveform can reduce ramp up time in the ramp reset waveform The experimental results show that the ramp up time can be reduced by about 90% compared with the conventional ramp reset waveform.

  • PDF