• 제목/요약/키워드: Discharge modules

검색결과 42건 처리시간 0.026초

State-of-Charge Balancing Control of a Battery Power Module for a Modularized Battery for Electric Vehicle

  • Choi, Seong-Chon;Jeon, Jin-Yong;Yeo, Tae-Jung;Kim, Young-Jae;Kim, Do-Yun;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.629-638
    • /
    • 2016
  • This paper proposes a State-of-Charge (SOC) balancing control of Battery Power Modules (BPMs) for a modularized battery for Electric Vehicles (EVs) without additional balancing circuits. The BPMs are substituted with the single converter in EVs located between the battery and the inverter. The BPM is composed of a two-phase interleaved boost converter with battery modules. The discharge current of each battery module can be controlled individually by using the BPM to achieve a balanced state as well as increased utilization of the battery capacity. Also, an SOC balancing method is proposed to reduce the equalization time, which satisfies the regulation of a constant DC-link voltage and a demand of the output power. The proposed system and the SOC balancing method are verified through simulation and experiment.

Design and implementation of IoT based controllers and communication module interfaces for stand-alone solar system

  • Lee, Yon-Sik;Mun, Young-Chae
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권1호
    • /
    • pp.129-135
    • /
    • 2019
  • This paper is part of research and development for stand-alone solar system without commercial power supply. It implements firmware of controller for operation of stand-alone solar system by applying IoT technology and also develops communication modules that allow multiple solar lamps to send and receive data through wireless network. The controller of the developed stand-alone solar system can effectively charge the power generated by the solar module, taking into account the battery's charge and discharge characteristics. It also has the advantage of attaching wireless communication modules to solar lamp posts to establish wireless communication networks without incurring communication costs. In addition, by establishing IoT gateway middleware platform for each installation site, it forms a foundation to operate multiple solar lamp posts into multiple clusters. And, it is expected that the data collected in each cluster will be used to enable configuration and control of operational information, thereby inducing convenience and efficiency of remote operation and management.

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

K-DRUM 모형의 개선을 통한 광동댐 유역의 봄철 융설 모의 (Snow Melting Simulation of Gwangdong Dam Basin in the Spring Season Using Developed K-DRUM Model)

  • 김현식;강신욱;황필선;허영택
    • 대한토목학회논문집
    • /
    • 제32권6B호
    • /
    • pp.355-361
    • /
    • 2012
  • 광동댐 유역은 융설에 의한 봄철 유출량 변화가 두드러지게 나타나는 유역으로서, 융설을 고려하지 않고 유출량을 산정할 경우 결과에 대한 신뢰성이 저하될 밖에 없다. 본 연구에서는 K-DRUM 모형에 융 적설 모듈을 포함하여 광동댐 유역을 대상으로 최근 4년간 봄철 유출량 모의를 수행하였다. 또한 융 적설 효과를 비교하기 위해 융 적설 모의기능이 적용되지 않은 경우와 적용한 경우의 결과를 비교하였다. 모의기간은 전년도 10월부터 해당연도 4월까지로 약 7개월간이고, 시단위 강우자료와 기상자료를 입력자료로 사용하였다. 유출량 모의 결과에 대한 모형의 성능을 평가하기 위하여 NSE, PBIAS, RSR 지수로 평가하였다. 신뢰성 평가 결과, 융 적설 모듈을 적용한 K-DRUM 모형은 봄철 융설에 의한 유출모의에 적용성이 우수한 것으로 나타났다.

Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화 (Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제39권3호
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

통신위성 배터리 충,방전기 설계 및 해석 (Design and Analysis of a Battery Charge and Discharge Regulator of Communication Satellite)

  • 최재동
    • 한국항공우주학회지
    • /
    • 제31권7호
    • /
    • pp.118-126
    • /
    • 2003
  • 본 연구에서는 모듈형태의 배터리 충-방전기가 정상상태뿐만 아니라 과도상태에서 예기치 못한 결함이 발생할지라도 실패 없이 전원을 공급하는 것이 가능한 병렬형 양방향 컨버터로 설계되어졌다. 컨버터 모듈은 안정성, 성능 및 고신뢰성을 얻기 위해 독립적인 제어가 가능하도록 설계되었으며, 제어기를 위해 사용된 평균전류모드방식은 노이즈 면역, 빠른 응답 및 평균전류 신호 획득과 같은 장점을 갖는다. 병렬 연결된 배터리 충-방전기에 대한 등가모델이 제시되었으며, 충전연속모드, 방전연속/불연속 모드에 대한 전달함수가 분석되었다. 병렬 양방향 컨버터는 스텝 부하변화와 하나의 컨버터 모듈 실패에 대해 각각 수행되었다. 그리고 병렬 양방향 컨버터의 성능이 실험결과들을 통해 검증되었다.

SIVCP용 BLE 모듈의 배터리 수명시험 (Lifetime test of batteries for BLE modules for site identification of vessel's crews and passengers (SIVCP))

  • 권혁주;김민권;김윤식;이성근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권7호
    • /
    • pp.754-759
    • /
    • 2015
  • 오늘날 선박 내 승선자의 위치인식과, 이를 모니터링을 하는 데 저 전력 근거리 통신시스템이 많이 개발되고 있으며, 이러한 저 전력 근거리 통신을 위해서 BLE, Zigbee 등과 같은 저 전력 통신 모듈이 이용되고 있다. 저 전력 통신 모듈은 1:N 통신이 가능하고, 휴대폰, 인체 등의 이동 물체에 탑재할 수 있어 각광을 받고 있다. 저 전력 통신모듈을 사용하는 데 있어서, 배터리의 용량이나 크기가 각각 시스템의 작동시간이나 통신모듈의 디자인에 중요한 요소가 된다. 따라서 모듈은 가급적 작게 만들어져야 하고, 배터리는 모듈의 크기보다 더 작게 선정되는 것이 바람직하다. 본 논문에서는 전송률 1/250 조건에서 데이터 시트와 방전특성 그래프를 참조하여 SIVCP용 BLE 모듈에 사용되고 있는 배터리의 이론 수명을 산출하고, 위와 동일한 전송률과 1/5000 전송률의 조건에서 각각 송전전류와 저속모드 전류를 검출하여 실험수명을 산출하며, 전송률을 1/25로 하여 수일 동안 고속 방전 장기 실험수명을 측정한다. 이와 같은 실험을 통하여, 배터리의 수명예측과 수명연장 방법을 실험적으로 검증하고, 이를 선박의 용도와 승객의 유형에 따른 적절한 배터리 선정에 활용하고자 한다. 모듈의 전송률과 배터리 크기 선정은 모듈의 설계비용의 감소, 배터리 유지관리 및 승객의 편의 등에 중요한 영향을 미치는 요소가 된다.

한강 홍수예경보시스템의 저수지 운영모듈 개선 (Improvement for Reservoir Operation Module of Flood Forecasting-Warning Systems in Han River)

  • 권오익;김승;심명필
    • 한국수자원학회논문집
    • /
    • 제32권6호
    • /
    • pp.685-695
    • /
    • 1999
  • 홍수예경보란 홍수예측시 적기에 홍수예경보를 발령하여 홍수피해를 경감시키고자 하는 방재활동의 일환으로 이는 홍수조절과정을 전제로 한다. 유역내에서 홍수조절을 직접 수행할 수 있는 곳은 홍수조절용량을 갖추고 있는 다목적 댐으로 홍수시 다목적 댐의 역할은 매우 중요하다고 할 수 있다. 홍수예경보시스템에서 이러한 다목적 댐의 저수지 운영과 관련된 부분의 바로 저수지 운영모듈이다. 본 연구에서는 한강홍수통제소에 구축된 저수지 운영모듈의 현황과 문제점을 고찰하여 한정된 범위내에서 개선작업을 수행하였고 결과적으로 Technical ROM과 ARD ROM을 추가적인 저수지 운영모듈로 구축하였다. 새로이 구축된 저수지 운영모듈을 이용하여 홍수시 한강 홍수통제소는 Technical ROM과 같은 확정론적인 모의방법을 통해 우선 홍수통제에 관한 1차적인 계획을 수립하고, 이후 승인된 방류량에 따라 ARD ROM을 이용하여 최종적인 홍수통제 및 예측 업무를 수행할 수 있을 것이다.

  • PDF

ESCORT 모형의 3차원 적용성 - 담수방류 모의 (3-D Applicability of the ESCORT Model - Simulation of Freshwater Discharge)

  • 강주환;김양선;박선중;소재귀
    • 한국해안·해양공학회논문집
    • /
    • 제21권3호
    • /
    • pp.230-240
    • /
    • 2009
  • 선행연구에서 개발된 ESCORT 모형을 사용하여 영산강하구언 배수갑문을 통한 담수방류의 영향성을 분석하였다. 낙조우세를 감안한 해수유동 모의를 통해 2차원 뿐 아니라 3차원 흐름해석에 있어서도 모형의 적용성과 타당성을 입증하였다. 방류가 흐름양상에 미치는 영향성을 분석하였으며, 담수방류 모의 결과 확산현상은 3차원 모형으로 해석해야 함을 확인할 수 있었다. 또한, 방류구 인근에서 염도의 연직분포 특성을 규명하였고 목포해역 담수확산 범위를 추정하였다. 그 결과 외해수와의 해수교환이 원활치 않음에 기인하여, 목포해역에서는 담수농도의 희석이 매우 느리게 진행되고 있음을 확인할 수 있었다.

복합형 유역모델 STREAM의 개발(II): 모델의 시험 적용 (Development of a Hybrid Watershed Model STREAM: Test Application of the Model)

  • 조홍래;정의상;구본경
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.507-522
    • /
    • 2015
  • In this study, some of the model verification results of STREAM (Spatio-Temporal River-basin Ecohydrology Analysis Model), a newly-developed hybrid watershed model, are presented for the runoff processes of nonpoint source pollution. For verification study of STREAM, the model was applied to a test watershed and a sensitivity analysis was also carried out for selected parameters. STREAM was applied to the Mankyung River Watershed to review the applicability of the model in the course of model calibration and validation against the stream flow discharge, suspended sediment discharge and some water quality items (TOC, TN, TP) measured at the watershed outlet. The model setup, simulation and data I/O modules worked as designed and both of the calibration and validation results showed good agreement between the simulated and the measured data sets: NSE over 0.7 and $R^2$ greater than 0.8. The simulation results also include the spatial distribution of runoff processes and watershed mass balance at the watershed scale. Additionally, the irrigation process of the model was examined in detail at reservoirs and paddy fields.