• 제목/요약/키워드: Discharge modules

검색결과 42건 처리시간 0.03초

태양광 가로등 발전 효율개선 연구 (The improved efficiency Study of PV system for the Solar lamp lighting)

  • 강신영;이양규;김광헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.304-308
    • /
    • 2002
  • This paper studies stand-alone photovoltaic array for solar lighting lamp. The solar lighting lamp has PV modules, batteries. and charge & discharge system. The charge efficiency is improved for the control of each battery which is divided the charge from the discharge to change the structure of existing solar lighting lamp charge & discharge system. so, the charge and discharge times are reduced of 50%. and the depth of discharge control can be controlled in the discharge cut off voltage. This can be effective of battery use. If a battery is out of order, this system can be executed for a regular period. so we saved the repair cost and developed of system's stabilization. It is possible economical effect to apply for solar lighting lamp used photovoltaic array.

  • PDF

Treatment and Reuse of Acrylic Wastewater using Membrane Separation System

  • Lee, Kwanghyun
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Proceedings of the second conference of aseanian membrane society
    • /
    • pp.117-120
    • /
    • 2004
  • The separation characteristics were investigated with the variations of pressure and temperature using ultrafiltration and reverse osmosis membrane module sets composed of different membrane types and materials. TDS, T-N and COD removal efficiencies were not affected and low with the change of temperature and pressure in case of using UF modules contained in module set 1, 2, 3. TDS, T-N and COD removal efficiencies were very high in RO modules. The final water quality of acrylic wastewater was satisfied within the discharge limit value of plant wastewater. It was known that membrane module sets could be used for the reuse of wastewater.

  • PDF

전기 자동차용 니켈수소 배터리 1차원 열전달 모델링 (One-Dimension Thermal Modeling of NiMH Battery for Thermal Management of Electric Vehicles)

  • 한재영;박지수;유상석;김성수
    • 대한기계학회논문집B
    • /
    • 제38권3호
    • /
    • pp.227-234
    • /
    • 2014
  • 전기 자동차의 연료 소모량은 배터리 성능에 의존한다. 배터리의 성능은 작동온도에 민감하기 때문에, 배터리 온도 관리는 성능과 내구성을 보장한다. 특히, 배터리 팩에서의 모듈의 온도 분포는 냉각특성에 영향을 미친다. 이 연구는 모듈 사이의 온도 분포를 확인 할 수 있는 배터리 열적 모델링에 초점을 두었다. 본 연구의 배터리 모델은 NiMH 각형 모델이며, 10개의 모듈로 구성되어졌다. 배터리 열 모델은 열 발생, 채널을 통과하는 대류 열 전달 그리고 모듈 사이의 전도 열 전달로 구성되었다. 배터리 내에서 발생되는 열발생 모델은 충/방전 동안의 전기적인 저항열에 의해 계산되어 진다. 모델은 전 하이브리드 자동차의 운전 동안 적절한 열관리의 전략을 결정한다.

밧데리 개별 제어 방식에 의한 소규모 독립형 태양광 발전 시스템의 특성 개선 (The Improved Characteristics of the Stand-alone PV System by the Independent Battery Control Method)

  • 강신영;이양규;김광헌
    • 전력전자학회논문지
    • /
    • 제7권5호
    • /
    • pp.482-489
    • /
    • 2002
  • 본 연구는 PV모듈, 밧데리, 충·방전시스템 등으로 구성된 태양광 가로등을 대상으로 소규모 독립형 태양광 발전 시스템(SPVS)을 연구하였다. 태양전지의 발전 효율을 증가시키고 밧데리를 효율적으로 사용할 수 있도록 하기 위해 병렬로 연결된 밧데리를 개별적으로 제어할 수 있는 시스템을 제안하였다. 제안된 시스템은 기존의 방식에 비해 밧데리 충전효율이 증가되고 충방전 횟수를 50%정도 감소시킬 수 있다. 또한 병렬 연결된 전지를 개별적으로 충전 혹은 방전 모드로 제어함으로서 일부 밧데리 고장시에도 일정기간 동안은 정상동작이 가능하고, 밧데리의 고장이 정상적인 밧데리로 전이되는 것을 예방할 수 있어 시스템 유지 보수비용을 줄일 수 있어 태양광 가로등에 적용할 경우 비용절감이 가능할 것으로 예상된다.

무가선 전동차용 울트라커패시터 모듈 충·방전을 위한 DC-DC 컨버터 설계 (Design of DC-DC Converter to Charge and Discharge Ultra-Capacitor Modules for Wireless Trains)

  • 조정민;한영재;김재원;이장무;김길동
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1776-1781
    • /
    • 2015
  • Electric power trains receive electric power from overhead cables via a pantograph system. Power collector system in trains increase the cross section of tunnel and require a massive coreless filter reactor in propulsion inverter because of the power disturbance by contact loss phenomenon of a train. In this paper we proposed a wireless train which can run to next station with charging energy of ultra-capacitor module block. We designed DC-DC converter to charge and discharge ultra-capacitor modules by using Next Train running test results and confirm the feasibility of the proposed system through simulation.

전산유체해석을 이용한 점도가 다른 이종 용액의 토출 비율 연구 (A study on the discharge ratio of two solutions with different viscosities using computational fluid analysis)

  • 고민성;위은찬;윤이섭;공정식;이중배;김민수;백승엽
    • Design & Manufacturing
    • /
    • 제15권4호
    • /
    • pp.43-50
    • /
    • 2021
  • Pump-cap is a device for discharging the contents stored inside a container to the outside of the container by a simple operation by a certain amount. In particular, in recent years, as the number of cosmetic products made of functional materials has rapidly increased, the development of convenient containers for functional materials is being actively conducted. Among these, there are a growing number of products that show their efficacy only by mixing two components, so the development of a dual pump cap container is necessary. However, the conventional dual pump cap container has a problem in that it is difficult to implement a quantitative discharge as solutions having different viscosities are used. Therefore, in this study, a discharge port of a dual pump cap that can apply an optimal ratio was designed by analyzing the discharge amount of two components with different viscosities through computational fluid dynamics. Since the discharge amount is affected by the size of the discharge port, the higher the viscosity of the solution, the larger the discharge port should be set. Conversely, the lower the viscosity, the smaller the discharge port should be. Through this, it is possible to dispense a fixed amount of a heterogeneous solution by one pumping, and it is determined that the user's convenience will increase.

멀티 플라즈마 반응기를 이용한 E. coli 소독 (E. coli Disinfection Using a Multi Plasma Reactor)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제39권2호
    • /
    • pp.187-195
    • /
    • 2013
  • Objectives: For the practical application of the dielectric barrier discharge plasma reactor, a plasma reactor able to manage large volumes of water is needed. This study investigated the possibility of the practical application of a multi-plasma reactor which is a scaled-up version of a single plasma reactor. Methods: The multi-plasma reactor consists of several high-voltage transformers and plasma modules (discharge, ground electrodes and quartz dielectric tubes). The effects of water characteristics such as voltage (30-120 V), air flow rate (1-5 l/min), number of high-voltage transformers and plasma modules, and water quality on Escherichia coli (E. coli) disinfection and decrease of COD and $UV_{254}$ absorbance were investigated. Results: The experimental results showed that at a voltage of over 80 V, most of the E. coli were disinfected within 90 seconds. E. coli inactivation was not affected by the air flow rate. E. coli disinfection in the multiplasma process showed the traditional log-linear form of the disinfection curve. E. coli inactivation performance by transformer 3-Reactor 5 and transformer 3-Reactor 3 were similar. The disinfection performance of the UV process was affected by artificial sewage water. However, the plasma process was less affected by the artificial sewage within the standards for effluent water quality. Conclusions: Disinfection performance with several low voltages and plasma modules of three to five in number applied to the plasma process was higher than that concentrating a small amount of high voltage through a single plasma reactor. Removal of COD, $UV_{254}$ absorbance, and E. coli disinfection with the plasma process were better than with the UV process.

태양광 발전 PCS 구성부품에 대한 열적특성 및 고장모드영향분석 (Thermal Characteristic and Failure Modes and Effects Analysis for Components of Photovoltaic PCS)

  • 김두현;김성철;김윤복
    • 한국안전학회지
    • /
    • 제33권4호
    • /
    • pp.1-7
    • /
    • 2018
  • This paper is analyzed for the thermal characteristics(1 year) of the 6 components(DC breaker, DC filter(including capacitor and discharge resistance), IGBT(Insulated gate bipolar mode transistor), AC filter, AC breaker, etc.) of a photovoltaic power generation-based PCS(Power conditioning system) below 20 kW. Among the modules, the discharge resistance included in the DC filter indicated the highest heat at $125^{\circ}C$, and such heat resulting from the discharge resistance had an influence on the IGBT installed on the rear side the board. Therefore, risk priority through risk priority number(RPN) of FMEA(Failure modes and effects analysis) sheet is conducted for classification into top 10 %. According to thermal characteristics and FMEA, it is necessary to pay attention to not only the in-house defects found in the IGBT, but also the conductive heat caused by the discharge resistance. Since it is possible that animal, dust and others can be accumulated within the PCS, it is possible that the heat resulting from the discharge resistance may cause fire. Accordingly, there are two options that can be used: installing a heat sink while designing the discharge resistance, and designing the discharge resistance in a structure capable of avoiding heat conduction through setting a separation distance between discharge resistance and IGBT. This data can be used as the data for conducting a comparative analysis of abnormal signals in the process of developing a safety device for solar electricity-based photovoltaic power generation systems, as the data for examining the fire accidents caused by each module, and as the field data for setting component management priorities.

정지궤도 위성용 전력공급 모듈의 버스 전압 안정화를 위한 최적동작 제어에 관한 연구 (A Study on Adaptive Operation Control to Stabilize bus Voltage of GEO Satellite Power Supply Module)

  • 안태영;최현수
    • 전자공학회논문지
    • /
    • 제53권2호
    • /
    • pp.123-129
    • /
    • 2016
  • 본 논문에서는 PCU(Power Control Unit)의 성능을 최적화 시킬 수 있는 동작모드를 제안하고 제작하여 그 결과를 보고 하였다. 특히 세 개의 기능별 모듈이 최적의 동작 상태를 유지할 수 있도록 버스의 전압과 연동되게 제어회로를 구성하여 동작 우선순위를 정하고 필요에 따라 자동적으로 동작하도록 최적 동작 제어 방식을 제안하였다. PCU는 태양광 전력을 부하와 연결된 버스에 정전압으로 변환시키는 S3R(Sequential Switching Shunt Regulator)과 보조 에너지 저장장치인 배터리에 잉여 전력을 저장하는 BCR(Battery Charge Regulator) 및 배터리에 충전되어 있던 전력을 부하에 공급하는 BDR(Battery Discharge Regulator)로 구성되어 있다. 세 개의 전력변환 모듈은 위성용 전원장치의 특성상 높은 신뢰성을 유지하기 위해서 각각의 모듈이 병렬로 동작하며, 특히 각 모듈의 기능이 최적의 상태를 유지하기 위해서 안정된 버스 전압이 상시 유지되어야 한다.

멀티 플라즈마 공정을 이용한 하수 미생물의 불활성화 (Inactivation of Sewage Microorganisms using Multi-Plasma Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제23권5호
    • /
    • pp.985-993
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor, a multi-plasma reactor was investigated for the inactivation of microorganisms in sewage. We also considered the possibility of degradation of non-biodegradable matter ($UV_{254}$) and total organic carbon (TOC) in sewage. The multi-plasma reactor in this study was divided into high voltage neon transformers, gas supply unit and three plasma modules (consist of discharge, ground electrode and quartz dielectric tube). The experimental results showed that the inactivation of microorganisms with treated water type ranked in the following order: distilled water > synthetic sewage effluent >> real sewage effluent. The dissolved various components in the real sewage effluent highly influenced the performance of the inactivation of microorganisms. After continuous plasma treatment for 10 min at 180 V, residual microorganisms appeared below 2 log and $UV_{254}$ absorbance (showing a non-biodegradable substance in water) and TOC removal rate were 27.5% and 8.5%, respectively. Therefore, when the sewage effluent is treated with plasma, it can be expected the inactivation of microorganisms and additional improvement of water quality. It was observed that the $NH_4{^+}$-N and $PO{_4}^{3-}$-P concentrations of sewage was kept at the constant plasma discharging for 30 min. On the other hand, $NO_3{^-}$-N concentration was increased with proceeding of the plasma discharge.