• 제목/요약/키워드: Discharge loading

검색결과 171건 처리시간 0.023초

전철 탑재형 피뢰기의 모듈설계 및 성능평가기술 (Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock)

  • 조한구;김석수;한세원;이운응
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

염색폐수 처리를 위한 하이브리드 플라즈마 특성연구 (A Study on the Characteristics of Hybrid-Plasma Torch for Dyeing Wastewater Treatment)

  • 정장근;윤석현;박재윤;김상돈
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.75-81
    • /
    • 2008
  • 본 논문은 플라즈마를 이용한 수처리 연구를 수행하였다. 이 연구에 사용한 수중플라즈마 토치는 상당한 전력의 절감을 가져올 수 있기 때문에 경제적인측면과 에너지효율면에서 뛰어난 결과를 나타내었다. 수중에서 일어나는 스트리머방전과 아크방전 현상을 면밀히 조사하여 비교하였고, 또한 염색페수를 플라즈마로 처리하였을 시의 색도제거율과 용존오존, 과산화수소와의 상관관계를 알기위해 표본화하고 분석하였다. 이에 플라즈마토치에는 선택적인 산화반응이 다소 있긴 하지만, 플라즈마화학반응에 의한 $H_2O_2$$O_3$의 성장이 아크방전 보다 스트리머방전시 더 효과적으로 촉진된다는 것을 알 수 있었다. 따라서 스트리머방전이 아크플라즈마 토치에 비해 더 효율적인 플라즈마 화학반응을 일으킬 수 있는 환경을 만들어주므로, 수처리에 있어서 스트리머플라즈마토치가 더 적합하였다.

전철 탑재용 피뢰기의 설계 및 성능평가 (Design and Performance Evaluation of Surge Arrester for Loading in Railway Rolling Stock)

  • 조한구;한세원;이운용;김석수;장태봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.74-77
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock. pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

GIS를 이용한 환경오염의 예측 모델 (GIS- Based Predictive Model for Measure of Environmental Pollutant)

  • 이자원
    • 한국지역지리학회지
    • /
    • 제14권2호
    • /
    • pp.114-125
    • /
    • 2008
  • 본 연구는 GIS를 사용하여 메사추세츠 동부의 보스턴시에 위치한 넷폰셋 강 유역의 수질 오염 정도를 측정하기 위한 것이다. 관련된 오염물질로써 CDOM을 축출하여 지표면의 유수가 다양한 토지이용과 연계되어 바닷물로 흘러들어가는 과정을 예측하고 이를 모형화하게 된다. CDOM의 축출과 분석은 관련학과의 도움을 받아 그 결과를 산출하고, 이를 GIS의 공간분석 기법을 이용하여 지역과 지형적인 특성에 따라 오염물질이 전해지면서 토지이용에 어떠한 변화가 생기는지를 관측하게 된다. 수계의 형성과 강의 흐름, 그리고 토지이용 자료가 연구를 위해 분석 자료로 사용되었고, ArcGIS 9.2를 사용, 공간분석 기법을 통해 하위 분수계와 유동점, 토지이용 구획을 산출하게 된다. 이는 GIS 기법이 지형분석과 오염물질의 이동을 분석하는데 어떻게 활용될 수 있는지를 고찰하는 것으로써 의미있는 연구가 될 것이다.

  • PDF

가스확산층의 압축에 따른 공극률 및 기체투과율의 변화 (Variation of Porosity and Gas Permeability of Gas Diffusion Layers Under Compression)

  • 이용택
    • 대한기계학회논문집B
    • /
    • 제37권8호
    • /
    • pp.767-773
    • /
    • 2013
  • 본 연구는 높은 압력으로 체결되어 있는 고분자전해질연료전지(PEMFC) 스택의 구성부품중 가장 크게 변형되는 가스확산층(GDL)의 공극률과 기체투과율의 변화를 제시하였다. 압축하중에 따른 체적변화를 실험을 통하여 측정하고 기존에 제시된 관계식을 이용하여 공극률과 기체투과율의 변화을 예측하였다. 또한 물의 배출을 향상시키기 위하여 첨가되는 PTFE 가 압축상태의 GDL 의 공극률과 기체투과율에 미치는 영향을 연구하였다. 물질전달에 직접 영향을 미치는 기체투과율은 PTFE 가 많이 포함된 GDL에서 급격하게 감소하였다. 결과적으로 같은 압축하중으로 체결하는 경우 GDL 의 PTFE 함량에 따라서 공극네트워크를 통한 물질전달은 크게 달라질 수 있다. 본 결과를 이용하면 GDL 에서의 전달현상에 대한 개선된 상관식을 개발할 수 있고 그로 인하여 모델링의 정확성을 향상시킬 수 있다.

GIS와 RS를 이용한 목현천 수질관리 정보체계 (A Water Quality Management System at Mokhyun Stream Watershed Using GIS and RS)

  • 이인수;이규석
    • 환경영향평가
    • /
    • 제8권4호
    • /
    • pp.1-12
    • /
    • 1999
  • 본 연구의 목적은 지리정보시스템과 원격탐사를 이용하여 체계적이고 효율적인 수질관리 자료기반을 구축하고, 유역의 오염부하를 산정하여 장래의 수질을 예측할 수 있는 수질관리시스템을 구축하는데 있다. 수질관리를 위해서는 오염물질의 최적처리 등의 기술적 측면뿐만 아니라 수질환경에 관한 정확한 정보의 취득과 관리가 필요하다. 본 연구에서는 지형 및 속성정보의 입력 및 편집을 위해 ArcView 3.1을 사용하였으며, Avenue Script를 이용하여 사용자환경을 갖추도록 하였다. 또한, 토지피복분류를 위하여 20m 해상도의 SPOT XS영상을 대상으로 PCI 소프트웨어를 이용하여 분석하였다. 수질관리시스템은 데이터베이스 보조시스템과 Modeling 보조시스템으로 구성된다. 데이터베이스 보조시스템은 수치지형도에서 추출한 수치표고모델에서 분석한 유역분할도, 위성영상자료, 정부보고서, 통계자료들로 구성되며, Modeling 보조시스템은 강우 시와 비강우시의 유역의 오염부하량을 산정하고 수질예측을 하는 SPLM(Storm Pollutant Loading Model)과 NSPLM(Non-Storm Polutant Loading Model)으로 구성된다. 각각의 보조시스템은 그래픽 출력 부분과 결합하여 분석결과 및 유역현황을 표시하도록 설계되었다. 개발된 수질관리 시스템은 경기도 광주군 광주읍에 위치한 목현천 유역을 대상으로 적용되고 수정되었다.

  • PDF

다변량 해석기법을 이용한 인천연안해역의 수질평가 (The Evaluation of Water Quality in Coastal Sea of Incheon Using a Multivariate Analysis)

  • 김종구
    • 한국환경과학회지
    • /
    • 제15권11호
    • /
    • pp.1017-1025
    • /
    • 2006
  • This study was conducted to evaluate characteristic of water duality in coastal sea of Incheon using a multivariate analysis. The analysis data in coastal sea of Incheon was aquired by the NFRDI data which was surveyed from March 1997 to November 2003. Eleven water quality parameters were determined on each survey The results were summarized as follow : Water quality in Incheon coastal sea could be explained up to 64.62% by three factors which were included in loading of fresh water and nutrients by the land(36.98%), seasonal variation(16.19%), and internal metabolism (11.24%). The results of time series analysis by factor score, in case of factor 1, station 1 influenced by Han river was shown to high factor score and station 3 located by outer sea was shown to low factor score. In case of factor 2, station 1 was appeared to high variation and station 3 was appeared to low variation. The result of cluster analysis by station was classified into three group that has different water quality characteristics. Especially, station 1 which affected by Han river and station 4 which affected by sewage treatment plant was appeared to considerable water quality characteristics against other station. In yearly cluster analysis, three group was classified and water quality in 2003 years due to high precipitation was different to another year. It could be suggested from these results that it is important to control discharge of fresh water by Han rivet and sewage treatment plant for water quality management of coastal sea of Incheon.

침전지내장형 상분리 산화구공정에 의한 하수 고도처리특성 평가 (Performance Evaluation of Advanced Municipal Wastewater Tretment by Phased Isolation Intrachannel Clarifier Ditch)

  • 홍기호;장덕;한상배
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.563-570
    • /
    • 2004
  • Phased isolation intrachannel clarifier ditch process developed in this study is an enhanced biological nutrient removal process employing two ditches with intrachannel clarifiers. Bench-scale phased isolation ditch process was used to evaluate the system performance on municipal wastewater and detailed assessment of internal behavior in a ditch and each reactions. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31 days, and cycle times of 4hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 73~78%, and 65~90%, respectively. The internal behavior were well matched on each reactions such as nitrification, denitrification, and phosphorus release and uptake. As the SRT became longer, TN removal increased gradually, whereas TP removal decreased contrarily. However, the system was capable of producing an effluent TP concentration 1mg/L or less even at longer SRTs except the case of solids discharge by malfunction of intra-clarifier occurred by its geometrical limit. The system performance slightly decreased by hydraulic shock loading(increasing of influent flowrate and decreasing of system HRT). However, the higher system performance could be achieved again after four cycles. Thus, the system reliability could be successfully achieved short-term hydraulic shock loading that occurred in medium- and small-sized wastewater treatment plants suffering fluctuation of influent quality and flowrate during wet season.

금호강 유역의 대장균 부하지속곡선 개발 및 적용 (Development and Application of Coliform Load Duration Curve for the Geumho River)

  • 정강영;임태효;김경훈;이인정;윤종수;허성남
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.890-895
    • /
    • 2012
  • Duration curves describe the percentage of time that a certain water quality (total/fecal coliform (=TC/FC)) or discharge is exceeded. The curves methodology are usually based on daily records and are useful in estimating how many days per year and event will be exceeded. The technique was further applied to estimated TC/FC loading to the Geumho River, using the daily mean flow rate and TC/FC concentration data during January, 2001 and December, 2011 for the Geumhogang6 (=Seongseo water level station) where an automated monitoring station is located in Gangchang-bridge. Low flow of the Seongseo (=11.1 cms) was equivalent to 75.3% on an exceedance probability scale. Load Duration curve for TC/FC loading at the Seongseo was constructed. Standard load duration curve was constructed with the water quality criteria for class III (TC/FC concentration = 5000/1000 CFU/ 100 mL). By plotting TC/FC observed load duration curve with standard load duration curve, it could be revealed that water quality do not meet the desired water quality for 68.8/11.2% on an exceedance probability scale. IF linear correlation between flow rate and coliform concentration is assumed, it can be interpreted that water quality exceed desired criteria when daily average flow rate is over 11.9/109.9 cms.

심미적 영역에서 즉시 임플란트 식립 및 임시 수복을 통한 단일치의 수복에 대한 증례 보고 (Immediate implant placement and provisionalization of single implant in the esthetic region : Cases report)

  • 이성배;박유선;김병헌;이보아;최성호;김영택
    • 대한치과의사협회지
    • /
    • 제58권2호
    • /
    • pp.83-92
    • /
    • 2020
  • In the anterior maxillary area, dental implants for tooth replacement are challenging due to the need to satisfy high esthetic level as well as functionality. Immediate implant placement and provisionalization can dramatically reduce the edentulous period, and then fulfill patient's demand for esthetics. The aim of present case report is to demonstrate two cases that successfully restored single tooth with immediate implant placement and provisionalization in the anterior maxillary area. A 47 years old female was scheduled to replace her maxillary right central incisor due to crown-root fracture by trauma. Another 54-year-old female was planned to place dental implant following tooth extraction of maxillary right lateral incisor owing to continuous pus discharge despite repetitive treatments including apicoectomy. In these two cases, surgical and prosthetic procedures progressed in a similar way. After minimal flap elevation, atraumatic tooth extraction was performed. Implant was placed in proper 3-dimensional position and angulation with primary stability. Bone graft or guided bone regeneration for peri-implant bone defect was conducted simultaneously. Provisionalization without occlusal loading was carried out at the same day. Each definitive crown was delivered at 7 and 5 months after the surgery. Two cases have been followed uneventfully for 2 to 5 years of loading time. In conclusion, Immediate implant placement and provisionalization could lead to esthetic outcome for single tooth replacement with dental implant under proper case selection.

  • PDF