• Title/Summary/Keyword: Discharge limit

Search Result 181, Processing Time 0.023 seconds

A Method for Reducing the Residual Voltage of Hybrid SPD Circuit Using Choke Coil (초크코일을 이용한 SPD 조합회로의 잔류전압 저감기법)

  • Cho, Sung-Chul;Eom, Ju-Hong;Lee, Tae-Hyung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.96-101
    • /
    • 2007
  • Gas Discharge Tubes (GDTs) are widely used as surge protectors for communication applications due to their small internal capacitance. In these days, however, they are mostly used in combined configurations, because the sparkover voltage required to initiate the discharge process in the GDTs and the time taken for arc formation process can be large enough to damage to sensitive circuits. For GDTs with a considerably high initial residual voltage, we should limit the peak voltage using a TVS or filter. We made a hybrid SPD circuits of common-mode type and differential-mode type with the filter using common-mode choke. Also, we applied lightning impulse voltage and ring wave voltage which frequency bandwidth are different each other and verified the characteristics of hybrid SPD circuits according to waveshapes. We describe how the applied SPDs operate in protection process steps with the actual data obtained from the residual voltage measurement at each step. The experiment results show that the surge voltage reduction with the choke coil is more effective in differential-mode circuit than in common-mode circuit.

Development of active discharge tester for high capacity lithium-ion battery (대용량 리튬 이온 배터리용 Active 방전시험기의 개발)

  • Park, Joon-Hyung;Yunana, Gani Dogara;Park, Chan Won
    • Journal of Industrial Technology
    • /
    • v.40 no.1
    • /
    • pp.13-18
    • /
    • 2020
  • Lithium-ion batteries have a small volume, light weight and high energy density, maximizing the utilization of mobile devices. It is widely used for various purposes such as electric bicycles and scooters (e-Mobility), mass energy storage (ESS), and electric and hybrid vehicles. To date, lithium-ion batteries have grown to focus on increasing energy density and reducing production costs in line with the required capacity. However, the research and development level of lithium-ion batteries seems to have reached the limit in terms of energy density. In addition, the charging time is an important factor for using lithium-ion batteries. Therefore, it was urgent to develop a high-speed charger to shorten the charging time. In this thesis, a discharger was fabricated to evaluate the capacity and characteristics of Li-ion battery pack which can be used for e-mobility. To achieve this, a smart discharger is designed with a combination of active load, current sensor, and temperature sensor. To carry out this thesis, an active load switching using sensor control circuit, signal processing circuit, and FET was designed and manufactured as hardware with the characteristics of active discharger. And as software for controlling the hardware of the active discharger, a Raspberry Pi control device and a touch screen program were designed. The developed discharger is designed to change the 600W capacity battery in the form of active load.

An Experimental Study on the Pump Operating Characteristics with Low Flow Operation (펌프의 저 유량 운전특성에 관한 실험적 연구)

  • 오광석;신필권;박종호;심우건;조두연
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.85-96
    • /
    • 1999
  • For ASME Code pumps in nuclear power plants, inservice test is required to assess the operational readiness in accordance with ASME code and related regulations. The objective of this study therefore, is to develop the technical background of the degradation of pump performances and conditions due to low flow rate operation. In addition. the detection techniques of pump operating conditions are to be developed to enhance the safety and economy of nuclear power plants. A test loop consisted of pump, motor. water tank, flow rate measurements and piping system with flow control devices was established for this study. Two typical pumps, 1-stage volute pump and 3-stage turbine pump, were selected and the test was performed upon two major point of views ; i.e., pump discharge pressure pulsations analysis and pump vibration spectrum analysis. From the test results, it is concluded that (1) the pump vibration affected by the natural frequency of operating pump is significant in the low frequency zone (around 1 Hz) : the vibration amplitude. especially. is an important factor during low flow rate operation. and shall be monitored to ensure that it is within the limit of ASME OM code Part 6, (2) the vibration frequency and pump discharge pressure are affected by vane pass frequency and running speed, (3) the wave phenomena due to the compressiblity of water is anticipated during low flow rate operation. and the pump system shall be designed to prevent it and. finally, (4) the technical background of the degradation of pump performances and conditions due to low flow rate operation is provided.

  • PDF

The Analysis of Hydrological Response Structure Based on Spatial Correlation of Extracted Geomorphic Variables by Using DEM (DEM에 의해 추출된 지형인자의 공간상관성을 기반으로 한 수문학적 응답구조의 해석)

  • Kim, Joo-Cheol;Choi, Yong-Joon;Kim, Jae-Han
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.2
    • /
    • pp.69-78
    • /
    • 2010
  • The hydrological-geomorphic character is closely related with runoff in basin. A development of GIS greatly helps investigating about mechanism between theirs. We analyze local slope and hillslope length which are related with hydrological response. But variation of these geomorphic variables has very wide range at each pixel. So there's a limit as to use directly. Therefore we investigate a relation between hydrological response and distributed geomorphic variables according to statistical character of distributed map considering spatial correlation. As a result, the local slope affects peak discharge, and the hillslope length affects peak discharge and time, mean and variance of hydrological response. Henceforth these hydrological-geomorphic analyze methods can be improved that hydrology response is directly analogized with DEM data.

A Study on the Washability and Washing Conditions of the Industrial Alkaline Laundry Detergent Suitable for Water Discharge Standards and Detergent Regulations (수질 배출기준 및 세제 안전기준에 적합한 산업용 알칼리 세탁세제의 세척성과 세탁조건 연구)

  • Song, Hyunjoo;Song, Sunhye
    • Textile Coloration and Finishing
    • /
    • v.33 no.4
    • /
    • pp.250-257
    • /
    • 2021
  • Laundry industry has traditionally been considered an industry that generates large amounts of wastewater and Volatile Organic Compounds(VOCs). This is still the case until now. Household laundry detergents are produced and distributed within the safety regulations on the amount of harmful substances detected. While industrial laundry detergents are often distributed without safety regulations, and even laundry workers manufacture and use them on their own. This contaminates water and air and also threatens the safety of workers. This study is a basic study for distributing eco-friendly detergents(EFD-A) developed through previous studies to the laundry industry. Safety, washability and wastewater quality of EFD-A are evaluated. Three existing commercial detergents(PD1, PD2, LD4) are also evaluated to compare with EFD-A. The safety of detergents is confirmed by the content of optical brightener, VOCs, and arsenic. Washability is evaluated by the difference in reflectance of washed and unwashed artificial soiled fabrics according to detergent concentration, washing temperature, and washing time. TOC is used as the index of assessing the wastewater quality. The results are as follows; EFD-A doesn't contain the optical brighteners, VOCs, and arsenic. The optimal washing conditions for EFD-A are 3 g/L concentration, 40 ℃ washing temperature, and 30 min washing time. The soil removal efficiency is about 71 %, which was similar to or somewhat superior to that of PD1, PD2, and LD4. TOC is 63.5 %, which is about 15 % lower than the discharge limit. Through this study, the developed detergent EFD-A can be used as a safe and eco-friendly detergent for the human body and the environment.

Electrochemical Properties of Tin-Antimony Sulfide Nanocomposites Synthesized by Hydrothermal Method as Anode Materials for Sodium Ion Batteries (수열 합성법에 의해 제조된 주석-안티몬 황화물계 나노복합체 기반 나트륨이온전지용 음극의 전기화학적 특성)

  • So Hyeon Park;Su Hwan Jeong;Suyoon Eom;Sang Jun Lee;Joo-Hyung Kim
    • Korean Journal of Materials Research
    • /
    • v.32 no.12
    • /
    • pp.545-552
    • /
    • 2022
  • Tin-antimony sulfide nanocomposites were prepared via hydrothermal synthesis and a N2 reduction process for use as a negative electrode in a sodium ion battery. The electrochemical energy storage performance of the battery was analyzed according to the tin-antimony composition. The optimized sulfides exhibited superior charge/discharge capacity (770 mAh g-1 at a current density of 100 mA g-1) and stable lifespan characteristics (71.2 % after 200 cycles at a current density of 500 mA g-1). It exhibited a reversible characteristic, continuously participating in the charge-discharge process. The improved electrochemical energy storage performance and cycle stability was attributed to the small particle size, by controlling the composition of the tin-antimony sulfide. By optimizing the tin-antimony ratio during the synthesis process, it did not deviate from the solubility limit. Graphene oxide also acts to suppress volume expansion during reversible electrochemical reaction. Based on these results, tin-antimony sulfide is considered a promising anode material for a sodium ion battery used as a medium-to-large energy storage source.

Dual-mobility versus Fixed-bearing in Primary Total Hip Arthroplasty: Outcome Comparison

  • Vivek Singh;Jeremy Loloi;William Macaulay;Matthew S. Hepinstall;Ran Schwarzkopf;Vinay K. Aggarwal
    • Hip & pelvis
    • /
    • v.34 no.2
    • /
    • pp.96-105
    • /
    • 2022
  • Purpose: Use of dual mobility (DM) articulations can reduce the risk of instability in both primary and revision total hip arthroplasty (THA). Knowledge regarding the impact of this design on patient-reported outcome measures (PROMs) is limited. This study aims to compare clinical outcomes between DM and fixed bearing (FB) prostheses following primary THA. Materials and Methods: All patients who underwent primary THA between 2011-2021 were reviewed retrospectively. Patients were separated into three cohorts: FB vs monoblock-D vs modular-DM. An evaluation of PROMs including HOOS, JR, and FJS-12, as well as discharge-disposition, 90-day readmissions, and revisions rates was performed. Propensity-score matching was performed to limit significant demographic differences, while ANOVA and chi-squared test were used for comparison of outcomes. Results: Of the 15,184 patients identified, 14,652 patients (96.5%) had a FB, 185 patients (1.2%) had a monoblock-DM, and 347 patients (2.3%) had a modular-DM prosthesis. After propensity-score matching, a total of 447 patients were matched comparison. There was no statistical difference in the 90-day readmission (P=0.584), revision rate (P=0.265), and 90-day readmission (P=0.365) and revision rate due to dislocation (P=0.365) between the cohorts. Discharge disposition was also non-significant (P=0.124). There was no statistical difference in FJS-12 scores at 3-months (P=0.820), 1-year (P=0.982), and 2-years (P=0.608) between the groups. Conclusion: DM bearings yield PROMs similar to those of FB implants in patients undergoing primary THA. Although DM implants are utilized more often in patients at higher-risk for instability, we suggest that similar patient satisfaction may be attained while achieving similar dislocation rates.

Evaluation of Agricultural Reservoirs Operation Guideline Using K-HAS and Ratio Correction Factor during Flood Season (수리·수문설계시스템 및 비율보정계수 기법을 활용한 농업용 저수지의 홍수기 운영기준 평가)

  • Jung, Hyoung-mo;Lee, Sang-Hyun;Kim, Kyounghwan;Kwak, Yeong-cheol;Choi, Eunhyuk;Yoon, Sungeun;Na, Ra;Joo, Donghyuk;Yoo, Seung-Hwan;Yoon, Gwang-sik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.4
    • /
    • pp.97-104
    • /
    • 2021
  • Despite the practical limitations of calculating the amount of inflow and supply related to the operation of agricultural reservoirs, the role of agricultural reservoirs is gradually being emphasized. In particular, as interest in disaster safety has increased, the demand for preliminary measures to prepare for disasters has been rising, for instance, pre-discharging agricultural reservoirs for flood control. The aim of this study is to analyze the plans for the flood season reservoir operation considering pre-discharge period and water level limit. Accordingly, we optimized the simulation of daily storage using the ratio correction factor (RCFs) and analyzed the amount of inflow and supply using K-HAS. In addition we developed the drought determination coefficient (k) as a indicator of water availability and applied it for supplementing the risk level criteria in the Drought Crisis Response Manual. The results showed that it would be difficult to set the water level limit during the flood period in the situation of little water supply for flood control in agricultural reservoirs. Therefore, it is necessary to operate the reservoir management regulations after measures such as securing additional storage water are established in the future.

Influence Analysis on the Number of Ruptured SG u-tubes During mSGTR in CANDU-6 Plants (중수로 증기발생기 다중 전열관 파단사고시 파단 전열관 수에 대한 영향 분석)

  • Seon Oh Yu;Kyung Won Lee
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2022
  • An influence analysis on multiple steam generator tube rupture (mSGTR) followed by an unmitigated station blackout is performed to compare the plant responses according to the number of ruptured u-tubes under the assumption of a total of 10 ruptured u-tubes. In all calculation cases, the transient behaviour of major thermal-hydraulic parameters, such as the discharge flow rate through the ruptured u-tubes, reactor header pressure, and void fraction in the fuel channels is found to be overall similar to that of the base case having a single SG with 10 u-tubes ruptured. Additionally, as the conditions of low-flow coolant with high void fraction in the broken loop continued, causing the degradation of decay heat removal, the peak cladding temperature (PCT) would be expected to exceed the limit criteria for ensuring nuclear fuel integrity. However, despite the same total number of ruptured u-tubes, because of the different connection configuration between the SG and pressurizer, a difference is foud in time between the pressurizer low-level signal and reactor header low-pressure signal, affecting the time to trip the reactor and to reach the PCT limit. The present study is expected to provide the technical basis for the accident management strategy for mSGTR transient conditions of CANDU-6 plants.

Development and assessment of pre-release discharge technology for response to flood on deteriorated reservoirs dealing with abnormal weather events (이상기후대비 노후저수지 홍수 대응을 위한 사전방류 기술개발 및 평가)

  • Moon, Soojin;Jeong, Changsam;Choi, Byounghan;Kim, Seungwook;Jang, Daewon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.775-784
    • /
    • 2023
  • With the increasing trend of extreme rainfall that exceeds the design frequency of man-made structures due to extreme weather, it is necessary to review the safety of agricultural reservoirs designed in the past. However, there are no local government-managed reservoirs (13,685) that can be discharged in an emergency, except for reservoirs over a certain size under the jurisdiction of the Korea Rural Affairs Corporation. In this case, it is important to quickly deploy a mobile siphon to the site for preliminary discharge, and this study evaluated the applicability of a mobile siphon with a diameter of 200 mm, a minimum water level difference of 6 m, 420 (m2/h), and 10,000 (m2/day), which can perform both preliminary and emergency discharge functions, to the Yugum Reservoir in Gyeongju City. The test bed, Yugum Reservoir, is a facility that was completed in 1945 and has been in use for about 78 years. According to the hydrological stability analysis, the lowest height of the current dam crest section is 27.15 (EL.m), which is 0.29m lower than the reviewed flood level of 27.44 (EL.m), indicating that there is a possibility of lunar flow through the embankment, and the headroom is insufficient by 1.72 m, so it was reviewed as not securing hydrological safety. The water level-volume curve was arbitrarily derived because it was difficult to clearly establish the water level-flow relationship curve of the reservoir since the water level-flow measurement was not carried out regularly, and based on the derived curve, the algorithm for operating small and medium-sized old reservoirs was developed to consider the pre-discharge time, the amount of spillway discharge, and to predict the reservoir lunar flow time according to the flood volume by frequency, thereby securing evacuation time in advance and reducing the risk of collapse. Based on one row of 200 mm diameter mobile siphons, the optimal pre-discharge time to secure evacuation time (about 1 hour) while maintaining 80% of the upper limit water level (about 30,000 m2) during a 30-year flood was analyzed to be 12 hours earlier. If the pre-discharge technology utilizing siphons for small and medium-sized old reservoirs and the algorithm for reservoir operation are implemented in advance in case of abnormal weather and the decision-making of managers is supported, it is possible to secure the safety of residents in the risk area of reservoir collapse, resolve the anxiety of residents through the establishment of a support system for evacuating residents, and reduce risk factors by providing risk avoidance measures in the event of a reservoir risk situation.