Influences of the Eu Concentration and the Milling Time on Photoluminescence Properties of Y2O3-H3BO3:Eu3+ Powders Prepared by Mechanical Alloying

  • Gong, Hyun-Sic;Kim, Hyun-Goo
    • Journal of Powder Materials
    • /
    • v.23 no.2
    • /
    • pp.108-111
    • /
    • 2016
  • $Y_2O_3-H_3BO_3:Eu^{3+}$ powders are synthesized using a mechanical alloying method, and their photoluminescence (PL) properties are investigated through luminescence spectrophotometry. For samples milled for 300 min, some $Y_2O_3$ peaks ([222], [440], and [622]) and amorphous formations are observed. The 300-min-milled mixture annealed at $800^{\circ}C$ for 1 h with Eu = 8 mol% has the strongest PL intensity at every temperature increase of $100^{\circ}C$ (increasing from 700 to $1200^{\circ}C$ in $100^{\circ}C$ increments). PL peaks of the powder mixture, as excited by a xenon discharge lamp (20 kW) at 240 nm, are detected at approximately 592 nm (orange light, $^5D_o{\rightarrow}^7F_1$), 613 nm, 628 nm (red light, $^5D_o{\rightarrow}^7F_2$), and 650 nm. The PL intensity of powder mixtures milled for 120 min is generally lower than that of powder mixtures milled for 300 min under the same conditions. PL peaks due to $YBO_3$ and $Y_2O_3$ are observed for 300-min-milled $Y_2O_3-H_3BO_3$ with Eu = 8 mol% after annealing at $800^{\circ}C$ for 1 h.

Solar Power Emotional LED Lightening Street Lamps with Multiple Control Sun Tracker (다중 추적식 태양광 발전 감성형 LED 가로등)

  • Lee, Jae-Min;Kim, Yong;Bae, Cheol-Soo;Kwon, Dae-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.920-926
    • /
    • 2011
  • In this paper, a solar power emotional LED lightening street lamps with multi control sun tracker is presented. The proposed system has a multiple control sun tracking function and high quality emotional LED lamps. The system is designed to absorb maximum sun lights by temperature sensor and humidity sensor of control circuits. A battery charge-discharge controller is developed for high efficient usage of battery charger for utilization of new and renewal energy. An interface circuit for remote monitoring and controlling is included in the developed system. The proposed multi tracking solar power emotional LED street lamps is better than conventional systems in aspect of tracking operation and energy efficiency, and expected to be a leading model for next generation solar power street lamp system, because it is a new technology combining sun tracking solar power system and emotional lightening system.

Design of Simulated Photovoltaic Power Streetlight for Education using Renewable Energy Utilization and Storage Function (신재생에너지 활용 및 저장기능을 이용한 교육용 모의 태양광발전 가로등 설계)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.2
    • /
    • pp.137-142
    • /
    • 2021
  • A Photovoltaic power streetlight is a system that uses solar energy to charge a secondary battery and then uses it for night lighting through a lamp, and can be configured as a standalone or grid-connected type by installing an LED streetlight at the load end. The energy generated through the solar cell module can be charged to the secondary battery through the charge/discharge control device, and then the LED street light can be turned on and off by comparing the power generation voltage and the charging voltage according to the monitoring of solar radiation, or by setting a specific time after sunset or sunrise. Based on these contents, this paper designed and manufactured a simulated solar power streetlight for education using new and renewable energy utilization and storage functions. Using these educational equipment, students can 1) understand the flow of energy change using renewable energy including sunlight as electric energy, 2) understand new and renewable energy, and cultivate basic design and manufacturing application power of related products, 3) The use of new and renewable energy through power conversion and strengthening of practical training and analysis through hardware production can be instilled.

Exact Solutions of Plasma Diffusion in a Fine Tube Positive Column Discharge (세관 양광주 방전에서 플라즈마 확산의 완전 해)

  • Jin, D.J.;Jeong, J.M.;Kim, J.H.;Hwang, H.C.;Chung, J.Y.;Cho, Y.H.;Lim, H.K.;Koo, J.H.;Choi, E.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.36-44
    • /
    • 2010
  • The ambipolar diffusion equation has been solved in a fine-tube lamp of a few mm in diameter. In the diffusion of radial direction, the plasma diffuses and vanishes away at the glass wall by recombination with the characteristic time of plasma loss is given by $\tau_r\;=\;(r_0/2.4)^2/D_a$. With the radius $r_0{\sim}1\;mm$ and the ambipolar diffusion coefficient $D_a{\sim}0.01\;m^2/s$, the vanishing time is calculated $\tau_r{\sim}10\;{\mu}s$ which corresponds to the least value of frequency 30 kHz for the sustaining the plasma in the operation of high voltage AC-power. In the diffusion of longitudinal z-direction, a high density plasma generated at the area of a high voltage electrode, diffuses into the positive column with the characteristic time $\tau_z{\sim}0.1\;s$. The plasma diffusion velocity at the boundary of high density plasma is $u_D{\sim}10^2\;m/s$ at the time $t{\sim}10^{-6}$ s and the diffusion velocity becomes slow as $u_D{\sim}1\;m/s$ at $t{\sim}10^{-3}\;s$. Therefore, for the long lamp of 1 m, it takes about several seconds for the high density plasma at the area of electrode to diffuse through the whole positive column space.

A Study on the Environment for Lowbirth Weight Infants in Neonatal Intensive Care Unit in the United States (신생아집중간호단위 환경과 저체중출생아의 반응에 대한 연구)

  • Han Kyung Ja
    • Child Health Nursing Research
    • /
    • v.4 no.2
    • /
    • pp.159-176
    • /
    • 1998
  • In effort to conduct comparative study on the caregiving environment of Neonatal Intensive Care Unit(NICU) in both U. S and Korea, this study was been conducted first in the U.S. Purpose : The purpose of this study is to identify the physical environment and direct caregiving practices to lowbirth weight infants in NICU in the US. It also aims to examine the NICU outcome status and behavioral reponses of lowbirth weight infants. Methods : A study design using descriptive and inferential statistics was been conducted through an observational, field method. A sample of 15 preform infants admitted to NICU were recruited for the study. The subjects were those with birth weight between 1,000 gm to 1,500 gm, born at the gestation period of 27 to 33 weeks, and without any chromosomal or other genetic anomalies, major congenital infections, or maternal illness. Thirty minutes observation(three times of ten minutes of continuous observation)of the infant's behavior and physiological status, and an four-hour observation of the physical environment and direct care giving procedures were been conducted on the 3rd and 10th day after birth, and on the day of discharge from the NICU or at 34weeks postconception. The data to be collected were in four areas : the demograghic characteristics of the infants, the physical environment and care giving procedures, the frequency of the infant's designated behavior and physiological response, and NICU outcome variables. A descriptive analysis and Kruskal-Wallis, Pearson r were been applied according to variable characteristics. Results : 1. Mother's mean age was 29.47. The sample consisted of 6 males and 9 females. Mean gestational ages were 29.17 weeks. Mean birth weight was 1236.33g. Mean Apgar scores at one minute were 6.6, and 7.8 at five minutes. 2. The location for the incubator was in the distance from the light, X-ray screens and nursing station, in proximity to side-lamp, telephone and faucet on the third day after birth. The location for the incubator was in the distance from the light and radio on the tenth day and in proximity to nursing station on the day of dischage from the NICU or at 34weeks postconception. 3. Nesting was the most applying aids to the infants. And foot roll, shielding and plastic frame were frequently using by nurses for facilitating well modulated restful posture. 4. There were statistically significant changes in the patterns of physical environment included locating the infant's incubator and bedding, specific aids to self regulation on the 3rd and 10th day after birth, and on the day of discharge from the NICU or at 34weeks postconception. 5. Statistically significant changes were not appeared in the patterns of direct caregiving procedure to the infants included stress inducing or reducing manipulations on the 3rd and 10th day after birth, and on the day of discharge from the NICU or at 34weeks postconception. 6. The stress response of the infants in NICU were significantly reduced as the infants grow older. 7. There were not statistically significant correlation between the physical envronment and the stress responses of the infants in NICU. 8. There were statistically significant correlation between the direct caregiving procedure to the infants and the stress response of the infants in NICU in the second and third observation on the day three. 9. Average weight gain per day from birth to discharge was 38.73g, number of days in the hospital was 42.60, number of days before bottle feeding was 3.6. Postconception age starting bottle feed ing was 31/sup +5/ weeks. Number of days on mechanical ventilator was average 7.64, 11.42 was an average number of days of oxygen need. Conclusion : It, thus, appears that to minimize the sensorymotor stimulation for the low birthweight preterm infant in NICU, manipulation of care giving practices to the babies whatever the stress inducing or reducing procedures, have to be limited in the immediate early stage after birth. And it needed to be reexamine to identify the appropriate and specific physical environment and the patterns of direct caregiving to the low birthweight preform infant as the infants grow older in NICU.

  • PDF

Marsupialization of the Nictitating Membrane Cyst Following Cherry Eye Repair in a Dog

  • Kim, Sunhyo;Kang, Seon-mi;Susanti, Lina;Kim, Boyun;Park, Yoonji;Shim, Jaeho;Go, Seokmin;Lee, Eunji;Seo, Kangmoon
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.149-152
    • /
    • 2020
  • One-year-old male Cocker Spaniel dog was referred for the third eyelid enlargement and inflammation in the left eye (OS). It gradually swelled for 2 weeks after the cherry eye repair by conjunctival mucosa pocket procedure at a private animal clinic. Routine ophthalmic examinations including neuro-ophthalmic examination, Schirmer tear test, intraocular pressure and corneal fluorescein staining were all normal. No lesions were found on slit lamp biomicroscopy and indirect ophthalmoscopy except for third eyelid swelling in the OS. Ultrasonography revealed cystic structure within the OS nictitating membrane. Fluid from the cyst was aspirated and there were no microorganisms or neoplastic changes. Surgical intervention was performed under general anesthesia. On the day of the surgery, there was a deep corneal ulcer in the OS, which had not existed before. Ventral palpebral surface of the third eyelid was incised horizontally to the shaft of the T-shaped hyaline cartilage. And then, a full thickness of the cystic wall was incised and marsupialized. Additionally, a direct suture was performed on the ulcerated cornea. Topical and systemic antibiotics and anti-inflammatory drugs were prescribed. One month after the surgery, the third eyelid swelling and the discharge were improved. Marsupialization of the nictitating membrane cyst relieved the swelling of the third eyelid and inflammation. It could be a simple but effective surgical intervention for the cystic complication of conjunctival mucosa pocket procedure in dogs.

Treatment of highly concentrated organic wastewater by high efficiency $UV/TiO_{2}$ photocatalytic system (고효율 자외선/광촉매 시스템을 이용만 고농도 유기성 폐수처리)

  • Kim, Jung-Kon;Jung, Hyo-Ki;Son, Joo-Young;Kim, Si-Wouk
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.83-89
    • /
    • 2008
  • Food wastewater derived from the three-stage methane fermentation system developed in this lab contained high concentration organic substances. The organic wastewater should be treated through advanced wastewater treatment system to satisfy the "Permissible Pollutant Discharge Standard of Korea". In order to treat the organic wastewater efficiently, several optimum operation conditions of a modified $UV/TiO_{2}$ photocatalytic system have been investigated. In the first process, wastewater was pre-treated with $FeCl_{3}$. The optimum pH and coagulant concentration were 4.0 and 2000mg/L, respectively. Through this process, 52.6% of CODcr was removed. The second process was $UV-TiO_{2}$ photocatalytic reaction. The optimum operation conditions for the system were as follows: UV lamp wavelength, 254 nm; wastewater temperature, $40^{\circ}C$; pH 8.0; and air flow rate, 40L/min, respectively. Through the above two combined processes, 69.7% of T-N and 70.9% of CODcr contained in the wastewater were removed.

Contamination level of commercialized pepper and sterilization effect by intense pulsed light in batch system (시중 판매 후추의 오염도 및 회분식 광펄스 처리에 의한 살균 효과)

  • Park, Jihyun;Shin, Jung-Kue
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.525-529
    • /
    • 2016
  • Twenty-nine pepper products commercially available in the market were collected and investigate for contamination levels. Pepper products purchased from traditional markets had a degree of contamination of $10^6-10^7CFU/g$ aerobic bacteria, $10^4-10^5CFU/g$ Bacillus sp., and less than $10^2CFU/g$ yeast and molds. Organic pepper showed a degree of contamination of $10^4$ aerobic bacteria, $10^2-10^3$ Bacillus sp., and less than $10^1$ yeast and molds. Intense pulsed light (IPL) treatment of 10 min (1,000 V, 5 pps and 4 cm sample-to-lamp distance) showed a bacterial death rate of 1.45-1.55 log for whole peppers, and of 0.8-0.85 log for black and white pepper powder. The sterilization rate using IPL was higher than that using other non-thermal sterilization methods, such as ozone treatment or low-pressure discharge plasma sterilization, indicating that the IPL sterilization method may find potential application in the industry. However, further studies may need to be conducted to enhance the effect of sterilization.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF