• Title/Summary/Keyword: Discharge estimation

Search Result 564, Processing Time 0.024 seconds

Estimation of Addition and Removal Processes of Nutrients from Bottom Water in the Saemangeum Salt-Water Lake by Using Mixing Model (혼합모델을 이용한 새만금호 저층수 내 영양염의 공급과 제거에 관한 연구)

  • Jeong, Yong Hoon;Kim, Chang Shik;Yang, Jae Sam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.4
    • /
    • pp.306-317
    • /
    • 2014
  • This study has been executed to understand the additional and removal processes of nutrients in the Saemangeum Salt-water Lake, and discussed with other monthly-collected environmental parameters such as water temperature, salinity, dissolved oxygen, suspended solids, and Chl-a from 2008 to 2010. $NO_3$-N, TP, $PO_4$-P, and DISi showed the removal processes along with the salinity gradients at the surface water of the lake, whereas $NO_2$-N, $NH_4$-N, and Chl-a showed addition trend. In the bottom water all water quality parameters except $NO_3$-N appeared addition processes indicating evidence of continuous nutrients suppliance into the bottom layer. The mixing modelling approach revealed that the biogeochemical processes in the lake consume $NO_3$-N and consequently added $NH_4$-N and $PO_4$-P to the bottom water during the summer seasons. The $NH_4$-N and $PO_4$-P appeared strong increase at the bottom water of the river-side of the lake and strong concentration gradient difference of dissolved oxygen also appeared in the same time. DISi exhibited continuous seasonal supply from spring to summer. Internal addition of $NH_4$-N and $PO_4$-P in the river-side of the lake were much higher than the dike-side, while the increase of DISi showed similar level both the dike and river sides. The temporal distribution of benthic flux for DISi indicates that addition of nutrients in the bottom water was strongly affected by other sources, for example, submarine ground-water discharge (SGD) through bottom sediment.

Performance effectiveness of pediatric index of mortality 2 (PIM2) and pediatricrisk of mortality III (PRISM III) in pediatric patients with intensive care in single institution: Retrospective study (단일 병원에서 소아 중환자의 예후인자 예측을 위한 PIM2 (pediatric index of mortality 2)와 PRIMS III (pediatric risk of mortality)의 유효성 평가 - 후향적 조사 -)

  • Hwang, Hui Seung;Lee, Na Young;Han, Seung Beom;Kwak, Ga Young;Lee, Soo Young;Chung, Seung Yun;Kang, Jin Han;Jeong, Dae Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1158-1164
    • /
    • 2008
  • Purpose : To investigate the discriminative ability of pediatric index of mortality 2 (PIM2) and pediatric risk of mortality III (PRISM III) in predicting mortality in children admitted into the intensive care unit (ICU). Methods : We retrospectively analyzed variables of PIM2 and PRISM III based on medical records with children cared for in a single hospital ICU from January 2003 to December 2007. Exclusions were children who died within 2 h of admission into ICU or hopeless discharge. We used Students t test and ANOVA for general characteristics and for correlation between survivors and non-survivors for variables of PIM2 and PRISM III. In addition, we performed multiple logistic regression analysis for Hosmer-Lemeshow goodness-of-fit, receiver operating characteristic curve (ROC) for discrimination, and calculated standardized mortality ratio (SMR) for estimation of prediction. Results : We collected 193 medical records but analyzed 190 events because three children died within 2 h of ICU admission. The variables of PIM2 correlated with survival, except for the presence of post-procedure and low risk. In PRISM III, there was a significant correlation for cardiovascular/neurologic signs, arterial blood gas analysis but not for biochemical and hematologic data. Discriminatory performance by ROC showed an area under the curve 0.858 (95% confidence interval; 0.779-0.938) for PIM2, 0.798 (95% CI; 0.686-0.891) for PRISM III, respectively. Further, SMR was calculated approximately as 1 for the 2 systems, and multiple logistic regression analysis showed ${\chi}^2(13)=14.986$, P=0.308 for PIM2, ${\chi}^2(13)=12.899$, P=0.456 for PRISM III in Hosmer-Lemeshow goodness-of-fit. However, PIM2 was significant for PRISM III in the likelihood ratio test (${\chi}^2(4)=55.3$, P<0.01). Conclusion : We identified two acceptable scoring systems (PRISM III, PIM2) for the prediction of mortality in children admitted into the ICU. PIM2 was more accurate and had a better fit than PRISM III on the model tested.

Analysis of weighted usable area and estimation of optimum environmental flow based on growth stages of target species for improving fish habitat in regulated and non-regulated rivers (조절 및 비조절 하천의 어류 서식처 개선을 위한 성장 단계별 가중가용면적 분석 및 최적 환경생태유량 산정)

  • Jung, Sanghwa;Ji, Un;Kim, Kyu-ho;Jang, Eun-kyung
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.spc2
    • /
    • pp.811-822
    • /
    • 2019
  • Environmental flows in the downstream sections of Yongdam Dam, Wonju Stream Dam, and Hongcheon River were estimated with selected target fish species such as Nigra for the site of Yongdam Dam, Splendidus for the site of Wonju Stream Dam, and Signifer for the site of Hongcheon River by considering endangered and domestic species. Physical habitat analysis was performed to estimate environmental flows for the study sites by applying the Physical Habitat Simulation (PHABSIM) and RIVER2D which combined hydraulic and habitat models. Based on the monitored data for ecological environment, the Habitat Suitability Index (HSI) for the target species was estimated by applying the Instream Flow and Aquatic Systems Group (IFASG). In particular, based on the result of fish monitoring, the HSI for each stage of the growth for target species was analyzed. As a result, the Weighted Usable Area (WUA) was maximized at $4.9m^3/s$ of flow discharge during spawning, $5.8m^3/s$ during the period of juvenile, and $8.9m^3/s$ during the adult fish season at the downstream section of Yongdam Dam. The result of the Wonju Stream Dam showed an optimal environmental flow of $0.4m^3/s$, $1.0m^3/s$, and $1.5m^3/s$ during the period of spawning, juvenile, and adult. The habitat analysis for the site of Hongcheon River, which is a non-regulated stream, produced an optimum environmental flow of $5m^3/s$ in the spawning period, $4m^3/s$ in the juvenile stage and $6m^3/s$ in the adult stage.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.