• 제목/요약/키워드: Discharge Tube

검색결과 335건 처리시간 0.028초

Photosensor를 이용한 재활 치료형을 위한 $CO_2$ laser 의 출력변동율 안정을 위한 실시간 제어특성 연구 (Real time control special quality research for $CO_2$ laser's output change rate stability for accumulation style surgical operation rehabilitation of ventriculus that use Photosensor)

  • 김휘영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.1015-1016
    • /
    • 2006
  • The important parameters deciding the fluctuation of Accumulation style surgical operation of ventriculus laser beam are smoothing capacitor, frequency and he characteristics of laser resonator. In this thesis, we control the fluctuation of medical $CO_2C$ laser in realtime by changing Duty-Ratio of IGBT and switching frequency with fixed the smoothing capacitor to improve the fluctuation of laser beam. We detect the light on laser resonator using a CdS photo sensor to improve ripple factor of laser beam and feedback fluctuated signals refined by a band pass filter into the control circuit to stabilize fluctuation actively. There is much to be desired in the realtime controlling technique of the light on Accumulation style surgical operation of ventriculus laser discharge tube in electrical signal. We propose switching control technique with microprocessor and photo sensing technique by controlling switch devices optimum operation and feedback signals detected by a photo sensor into the laser power supply in order to improve ripple factor of the $CO_2$ laser beam.

  • PDF

병렬식 하이브리드 흡수식 냉온수기 동특성 시뮬레이션 연구 (A Study on Dynamic Simulation of a Hybrid Parallel Absorption Chiller)

  • 신영기;서정아;우성민;김효상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.630-635
    • /
    • 2008
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism have been modeled. Flow discharge coefficients of the valves and the pumps were optimized for the double-effect mode with solar-heated water circulated. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. And the cases of the double mode with and without the solar energy were compared. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the single mode utilizing the solar energy only is not practical. It is suggested to operate the system in the double mode and the flow rate control system adaptive to variable solar energy input has to be developed.

  • PDF

반도체 웨이퍼의 오존 수(水) 세정을 위한 고농도 오존발생장치 특성 연구 (A Study on the Characteristics of the High Concentration Ozone Generator for the Semiconductor Wafer Cleaning with the Ozone Dissolved De-ionized Water)

  • 손영수;함상용;문세호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.579-585
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DI-O3 water) in semiconductor wet cleaning process to replace the conventional RCA methods has been studied. In this paper, we propose the water-electrode type ozone generator which has the ozone gas characteristics of the high concentration and high purity to produce the high concentration DI-O3 water for the silicon wafer surface cleaning process. The ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. We investigate the performance of the proposed ozone generator which has the design goal of the concentration of 7[wt%] and ozone generation quantity of 6[g/hr] at flow rate of 1[$\ell$/min). The experiment results show that the water electrode type ozone generator has the characteristics of 8.48[wt%] of concentration, 8.08[g/hr] of generation quantity and 76.2[g/kWh] of yield and it's possible to use the proposed ozone generator for the DI-O3 water cleaning process of silicon wafer surface.

자동차용 GAS SPRING의 최적 설계에 관한 연구 (A Study on the Optimal Design of Gas Spring for Vehicle)

  • 김영범
    • 한국정밀공학회지
    • /
    • 제15권11호
    • /
    • pp.39-45
    • /
    • 1998
  • Gas springs have been widely used in motor vehicles as well as in most areas of industry. Instead of coil springs, these gas springs are easily opreated to open(extension process) or close (compression process) the doors because $N_2$ gas with high pressure and oil are charged in tube. Most of manufacturers are using the trial & error method in order to decide its specification(reaction force, damping force), which tends to waste time and money. Therefore, gas springs have been improved by properly changing the control pressure of $N_2$ Gas with its mounting location and weight to maximize its effect and to minimize its space. Although it has been researched on damping structure to minimize impact which is applied to vehicle when its back door is fully opened, the characteristics of damping structure are not known clearly. There(ore, this paper will not only clearly define the effect of important factors(open & close force)for gas springs through theoretical analysis but also provide optimum design specification through development of program to avoid traditional method of specification determination such as the trail It error method which is widely used in whole industries including automotive industry.

  • PDF

가정용 인공 호흡기를 사용하는 소아의 임상적 고찰 (Clinical Study of Children Using Home Mechanical Ventilation)

  • 안영준;이승현;김효빈;박성종;고태성;홍수종
    • Clinical and Experimental Pediatrics
    • /
    • 제48권4호
    • /
    • pp.401-405
    • /
    • 2005
  • 목 적 : 급성 호흡부전증, 호흡중추장애, 신경근 질환 등으로 인한 만성 호흡부전 환자들이 가정용 인공 호흡기의 도입으로 가정에서 기계 환기를 받을 수 있게 되어 생명을 연장시키고, 삶의 질을 향상시킬 수 있어 그 사용하는 예가 증가하고 있다. 그러나 이에 대한 임상자료가 거의 없어 저자들은 인공 호흡기를 장착한 환아들을 대상으로 임상실태를 조사하였다. 방 법 : 1997년부터 2003년까지 서울아산병원 소아 중환자실에 입원 후 가정용 인공 호흡기를 장착한 21명의 환아들을 대상으로 하여 후향적으로 의무기록을 분석하고 전화면담을 시행하였다. 결 과 : 대상 환아들은 21명으로 남아 15명, 여아 6명이었다. 인공 호흡기를 장착하였을 때 중간 연령은 31개월(범위 : 2-150개월)이었으며, 호흡기를 장착한 중간 기간은 25개월(범위 : 2-68개월)이었다. 환아들의 원인 질환으로는 호흡중추장애를 포함한 신경근 질환이 16례, 급성 호흡곤란을 포함한 폐질환이 4례, 유전성 대사질환이 1례였다. 인공 호흡기 양식은 압력 조절 양식이 16례(76%), 용적 조절 양식이 5례(24%), 산소가 필요한 경우는 13례(62%)였고, 인공 호흡기를 조금이라도 이탈할 수 있었던 경우는 3례(14%)였다. 기계고장은 19개월마다 1회 발생하였고, 인공 호흡기 장착 후 평균 입원 횟수는 매년 1.7회, 그 원인으로는 폐렴(68%)이 가장 많았다. 추적 관찰한 결과 사망한 환아는 9명(43%)이었고, 사망원인은 기관지 튜브 폐쇄가 4례였다. 인공 호흡기 대여, 산소발생기, 영양식, 진찰 및 치료비용 등을 포함한 모든 의료비용은 월간 평균 111만원이었다. 결 론 : 최근 가정용 인공 호흡기 사용이 증가하고 있으며, 사망원인으로 기관지 튜브 폐쇄가 많아 주의 및 관리를 필요로 하고 인공 호흡기를 장착한 가정에 경제적 어려움이 있어 사회적 관심과 제도적 지원이 필요할 것으로 사료된다.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • 윤원섭;이상우
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

SG Tube 축방향 노치 균열의 정량적 EC 신호평가 (Quantitative EC Signal Analysis on the Axial Notch Cracks of the SG Tubes)

  • 민경만;박중암;신기석;김인철
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.374-382
    • /
    • 2009
  • 원자력발전소의 1차측 및 2차측 냉각계의 장벽 역할을 하는 핵심 설비중 하나인 증기발생기(steam generator, SG) 전열관은 공공의 사회적 안전성과 효율적인 발전 용량을 유지하기 위해 구조적 건전성을 유지하여야 한다. 또한 결함을 함유하고 있는 전열관은 해당결함을 조기에 검출, 정량적으로 결함을 평가하여 필요한 경우에는 보수조치를 수행하여야 한다. 이러한 결함의 검출 및 정량화를 위해서 검사관련 고시 및 강화된 SG 관리프로그램(SGMP)에 근거하여 와전류탐상검사법(eddy current testing, ECT)을 적용, 검사를 수행하고 있다. SG 전열관에서 검출되고 있는 결함중 응력부식균열(stress corrosion cracking, SCC)은 미세한 경우 결함의 검출이 어려울 뿐 아니라 생성된 결함의 성장속도가 빠르기 때문에 SG 전열관의 건전성을 위협하는 주요결함 기구중 하나로 분류하고 있다. 본 논문에서는 다양한 결함 깊이 및 길이별로 방전가공(electric discharge machining, EDM)된 축방향 ODSCC에 대해 pancake, +point 및 shielded pancake 코일 등이 탑재된 3 coil형태의 +PT MRPC(motorized rotating pancake coils)를 적용하여 결함의 검출가능 여부 및 크기 측정을 위한 검사를 수행하였으며 본 실험결과를 통해 SG 전열관의 건전성 및 원전 운전의 안전성을 진단하는 공학적 평가 자료로써의 활용 가능성 뿐 아니라 와전류탐상검사의 신뢰도 향상을 도모하고자 하였다.

양산용 80 kW급 RF Plasma Torch System 개발 및 Si 나노분말 제조 공정 연구 (Development of 80 kW RF Thermal Plasma Torch System for Mass Production and Research of Si Nano-Powder Manufacturing Process)

  • 송석균;손병구;김병훈;이문원;신명선;최선용;이규항;김성인
    • 한국진공학회지
    • /
    • 제22권2호
    • /
    • pp.66-78
    • /
    • 2013
  • 80 kW RF 플라즈마 토치 시스템을 개발하기 위하여, 토치 시스템에 대한 온도, 유체 거동 분석 등의 보다 많은 정보의 추출을 위하여 3차원 시뮬레이션을 진행했다. 파우더 주입관 위치, 입력 전류 변화에 따른 플라즈마 생성 특성, 세라믹 원통관 길이에 따른 플라즈마 방전 특성, 및 공정가스 유량에 따른 플라즈마 온도특성 등을 시뮬레이션 했다. 시뮬레이션을 통해 설계 제작된 RF 열 플라즈마 토치의 경우, 최대 89.3 kW까지 파워 인가가 측정되었다. 개발된 80 kW급 RF 열 플라즈마 토치 시스템의 양산성 평가로 Si 나노분말을 제조하고 특성을 고찰하였다. Si 나노분말의 생산량이 평균 539 g/hr의 양산 수준과 71.6%의 높은 수율을 달성했으며, 제조된 나노 분말은 $D_{99}/D_{50}$가 1.98의 좋은 입경 균일 분포도를 나타내었다.

극저온액체 저장용기에서 열전도 차폐단의 영향 (Effect of Vapor-Cooled Heat Stations in a Cryogenic Vessel)

  • 김서영;강병하;최항집
    • 한국수소및신에너지학회논문집
    • /
    • 제9권4호
    • /
    • pp.169-176
    • /
    • 1998
  • Ni/MH 2차전지의 음극용 금속간화합물전극의 부식특성에 미치는 합금원소와 결합제의 영향을 조사하였다. 전극의 재료는 $(LM)Ni_{4.49}Co_{0.1}Mn_{0.205}Al_{0.205}$$(LM)Ni_{3.6}Co_{0.7}Mn_{0.3}Al_{0.4}$$AB_5$ type합금을 모재로 하였다. 여기에 Si sealant 또는 PTFE를 결합제로 첨가한 것과 원재료 분말에 구리를 20% 무전해도금한 것을 냉간 압착하여 전극을 제조하였다. 부식특성을 조사하기위해 탈공기된 6M의 KOH 용액에서 동전위법과 순환전위법을 이용하여 부식전류와 전류밀도를 측정하였다. 모재에 Co가 많이 함유되면 전극의 내식성을 향상시키고 Ni이 많이 함유되면 충전과 방전을 반복하는 동안에 전극의 안정성을 저하시켰다. 부식전류밀도는 Si sealant를 결합제로 사용한 전극의 경우가 PTFE를 사용한 전극의 경우보다 낮았고 Cu가 도금된 전극은 내식성에서 가장 우수하게 나타났다.

  • PDF

Bronchoscopic Ethanolamine Injection Therapy in Patients with Persistent Air Leak from Chest Tube Drainage

  • Lim, Ah-Leum;Kim, Cheol-Hong;Hwang, Yong-Il;Lee, Chang-Youl;Choi, Jeong-Hee;Shin, Tae-Rim;Park, Yong-Bum;Jang, Seung-Hun;Park, Sang-Myeon;Kim, Dong-Gyu;Lee, Myung-Goo;Hyun, In-Gyu;Jung, Ki-Suck;Shin, Ho-Seung
    • Tuberculosis and Respiratory Diseases
    • /
    • 제72권5호
    • /
    • pp.441-447
    • /
    • 2012
  • Background: Chest tube drainage (CTD) is an indication for the treatment of pneumothorax, hemothroax and is used after a thoracic surgery. But, in the case of incomplete lung expansion, and/or persistent air leak from CTD, medical or surgical thoracoscopy or, if that is unavailable, limited thoracotomy, should be considered. We evaluate the efficacy of bronchoscopic injection of ethanolamine to control the persistent air leak in patients with CTD. Methods: Patients who had persistent or prolonged air leak from CTD were included, consecutively. We directly injected 1.0 mL solution of 5% ethanolamine oleate into a subsegmental or its distal bronchus, where it is a probable air leakage site, 1 to 21 times using an injection needle through a fiberoptic bronchoscope. Results: A total of 15 patients were enrolled; 14 cases of spontaneous pneumothorax [idiopathic 9, chronic obstructive pulmonary disease (COPD) 3, post-tuberculosis 2] and one case of empyema associated with broncho-pleural fistula. Of these, five were patients with persistent air leak from CTD, just after a surgical therapy, wedge resection with plication for blebs or bullae. With an ethanolamine injection therapy, 12 were successful but three (idiopathic, COPD and post-tuberculosis) failed, and were followed by a surgery (2 cases) or pleurodesis (1 case). Some adverse reactions, such as fever, chest pain and increased radiographic opacities occurred transiently, but resolved without any further events. With success, the time from the procedure to discharge was about 3 days (median). Conclusion: Bronchoscopic ethanolamine injection therapy may be partially useful in controlling air leakage, and reducing the hospital stay in patients with persistent air leak from CTD.