• Title/Summary/Keyword: Discharge Tube

Search Result 335, Processing Time 0.028 seconds

ITO/CNT Nano Composites as a Counter Electrode for the Dye-Sensitized Solar Cell Applications (ITO/CNT 나노 복합체의 염료감응형 태양전지의 이용)

  • Park, Jong-Hyun;Pammi, S.V.N;Jung, Hyun-June;Cho, Tae-Yeon;Yoon, Soon-Gil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.76-80
    • /
    • 2011
  • The ITO/Cabon Nano Tube (CNT) nano composites were deposited by nano cluster deposition (ITO) and arc discharge deposition (CNT) on glass substrates. The structural, optical and photovoltaic performance of ITO/CNT nano composites as a counter electrode of dye-sensitized solar-cells (DSSCs) such films were investigated. At low temperature below $250^{\circ}C$, the ITO films deposited on CNT. The ITO/CNT nano composit showed a good optical and electrical property for the counter electrode of DSSCs. When the as-prepared ITO/CNT nano composites are used for the counter electrodes, the photovoltaic parameters are $V_{OC}$ = 0.69 V, $J_{SC}$ = 5.69 mA/$cm^2$, FF = 0.32, and $\eta$ = 0.53 %. The ITO/CNT nano composites showed the possibility for the counter electrode applications of DSSCs.

Extracorporeal Worm Extraction of Diphyllobothrium nihonkaiense with Amidotrizoic Acid in a Child

  • Shin, Hye Kyung;Roh, Joo-Hyung;Oh, Jae-Won;Ryu, Jae-Sook;Goo, Youn-Kyoung;Chung, Dong-Il;Kim, Yong Joo
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.6
    • /
    • pp.677-680
    • /
    • 2014
  • Infection cases of diphyllobothriid tapeworms are not much in the below teen-age group. We report a case of Diphyllobothrium nihonkaiense infection in a 13-year-old boy. He presented with severe fatigue, occasional abdominal pain at night time. He also had several episodes of tapeworm segment discharge in his stools. By his past history, he had frequently eaten raw fish including salmon and trout with his families. Numerous eggs of diphyllobothriid tapeworm were detected in the fecal examination. We introduced amidotrizoic acid as a cathartic agent through nasogastroduodenal tube and let nearly whole length (4.75 m) of D. nihonkaiense be excreted through his anus. After a single dose of praziquantel, the child's stool showed no further eggs, and his symptoms disappeared. The evacuated worm was identified as D. nihonkaiense by mitochondrial cox1 gene analysis. Here we report a successful extracorporeal worm extraction from an infection case of D. nihonkaiense by the injection of amidotrizoic acid.

The RLG's Power Supply Design for Attitude Control in the Satellite (저궤도 위성 자세제어용 센서 RLG 전원 공급기 설계)

  • Kim, Eui-Chan;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1488-1490
    • /
    • 2008
  • The gyroscope is the sensor for detecting the rotation in inertial reference frame and constitute the navigation system together an accelerometer. As the inertial reference equipment for attitude determination and control in the satellite, the mechanical gyroscope has been used but it bring the disturbance for mass unbalance so the disturbance give a bad influence to the observation satellite mission because the mechanical gyroscope has the rotation parts. During the launch, The mechanical gyroscope is weak in vibration, shock and has the defect of narrow operating temperature range so it need the special design in integration. Recently the low orbit observation satellite for seeking the high pointing accuracy of image camera payload accept the FOG(Fiber Optic Gyro) or RLG(Ring Laser Gyro) for the attitude determination and control. The Ring Laser Gyro makes use of the Sanac effect within a resonant ring cavity of a He-Ne laser and has more accuracy than the other gyros. It need the 1000V DC to create the He-Ne plasma in discharge tube. In this paper, the design process of the High Voltage Power Supply for RLG(Ring Laser Gyroscope) is described. The specification for High Voltage Power Supply(HVPS) is proposed. Also, The analysis of flyback converter topology is explained. The Design for the HVPS is composed of the inverter circuit, feedback control circuit, high frequency switching transformer design and voltage doubler circuit.

  • PDF

A New Generation of Biocompatible Pulse-discharged Plasma by Marx Generator and Its Application on the Biomolecules

  • Park, Ji-Hun;Attri, Pankaj;Hong, Yeong-Jun;Kumar, Naresh;Kim, Sang-Yeop;Kim, Yeong-Jo;Lee, Gu-Hyeop;Lee, Seung-Mok;Park, Bong-Sang;Jeon, Su-Nam;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.240.2-240.2
    • /
    • 2014
  • Characteristics of pulse-discharged plasma in liquid and its biological applications to proteins are investigated by making use of high voltage Marx generator. The Marx generator has been consisted of 5 stages, where each charging capacitor is $0.5{\mu}F$ to generate a high voltage pulse with rising time of $1{\mu}s$. We have applied an input voltage of 6 kV to the each capacitor of $0.5{\mu}F$. The high voltage pulsed plasma has been generated inside a polycarbonate tube by a single-shot operation, where the breakdown voltage is measured to be 7 kV, current of 1.2 kA, and pulse width of ${\sim}1{\mu}s$ between the two electrodes of anode-cathode made of stainless steel, which are immersed into the liquids. For the investigation of the influence of pulsed plasma on biomolcules, we have focused on the amino acids, DNA, proteins, cell and cholesterol.

  • PDF

Optimal Characteristics of a Long-pulse $CO_2$Laser by Controlling SCR Firing Angle in AC Power Line

  • Noh, Ki-Kyung;Kim, Geun-Yong;Chung, Hyun-Ju;Min, Byoung-Dae;Song, Keun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.304-308
    • /
    • 2002
  • We demonstrate a simple pulsed $CO_2$ laser with millisecond long pulse duration in a tube at a low pressure of less than 30 Torr. The novel power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply doesn't need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. To control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of SCR(Silicon Controlled Rectifier) gate is varied from 30。 to 150。. A ZCS (Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control precisely the gate signal of the SCR. The maximum laser output of 35 W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60 Hz, and a SCR gate firing angle of 90。 . In addition, the resulting laser pulse width is approximately 3㎳(FWHM). This is a relatively long pulse width, compared with other repetitively pulsed $CO_2$ lasers.

A successful conservative management of traumatic thoracic esophageal rupture (흉부둔상에 의한 식도파열의 성공적인 보존적 치료)

  • 노태훈
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.169-174
    • /
    • 1988
  • Thoracic esophageal rupture caused by blunt trauma is often not recognized until late because of the vague symptoms in the initial state as well as its rare incidence, which can easily lead to fulminant mediastinitis with frequent fatal outcome. Once extensive mediastinitis occurs, the primary surgical repair of the esophageal tear is considered to be practically impossible. Various methods have been proposed for the management of these desperately ill patients, but no one provides an acceptable good result yet. The purpose of this article is to report the successful result obtained in the treatment of a patient with fulminant mediastinitis from traumatic esophageal rupture by continuous transesophageal irrigation. A 27 year-old male patient was brought to the emergency room of our hospital complaining of dyspnea and chest pain after blunt trauma. The diagnosis of esophageal rupture in the thorax was made late, about 46 hours after the initial injury, when mediastinitis had already progressed. The transesophageal irrigation method was immediately instituted which consisted of profuse transesophageal irrigation of the mediastinum with orally ingested fluid and/or by Levin tube, positioned proximal to the site of the rupture, and drainage of the irrigation fluid by thoracoscopically accurately positioned chest tubes connected to a well suctioning system. With subsiding inflammatory signs and symptoms, the esophagogram, obtained 54 days after the treatment, showed no evidence of the mediastinal leakage of contrast material which contrasted previous esophagograms with definitive dye collections in the mediastinum. Additional endoscopic finding confirmed complete healing of the esophageal mucosa, previously ruptured. He has been followed up without any problem until recently, 6 months after discharge.

  • PDF

Development of Nonthermal Bioplasma Source Applicable to Human Liquid Fluids

  • Min, Boo-Ki;Oh, Hyun-Joo;Song, Ki-Baek;Uhm, Han-Sup;Kang, Seung-Oun;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.327-327
    • /
    • 2011
  • A nonthermal bioplasma source was developed for application to human liquid fluids by making use of nano-size tungsten tips. Characteristics of the plasma source are investigated. Here we have used the AC voltage system. The bioplasma source generated by a tungsten tip with quartz tube and ground electrode is a low-temperature plasma without making any noticeable damage to cells at a low power operation. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current probe (P6021). Variation of breakdown temperature near the tip electrode is larger than that in the neighborhood of ground electrode. Bubble formation during discharge has been recorded and investigated by using the high speed camera. The existence and behavior of hydroxyl and superoxide radicals are detected and measured by spectrometers. The electrical and optical properties of breakdown characteristics are also investigated.

  • PDF

The Optimization of Output Characteristics with High Repetition Rate Pulsed $CO_2$ Laser Using SMPS (SMPS 방식의 고반복 펄스형 $CO_2$레이저의 출력특성 최적화)

  • Lee, D.H.;Chung, H.J.;Kim, D.W.;Kim, W.Y.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2192-2194
    • /
    • 1999
  • In this study, We have accomplished a new approach to develope a cheap and compact pulsed $CO_2$ laser system. We used a fast SCR as switching device instead of a thyatron in the pulsed power supply. Using the Pulse transformer, energy in the condenser is tranferred to the secondary, electrodes of discharge tube, from the primary. An axial and water cooled type was adopted as the laser cavity. The laser performance characteristics as various parameters, such as gas pressure and pulse repetition rate, have been investigated. As a result, the maxium laser output was 12.3[W] at a pulse repetition rate of 120[pps] and a filling pressure of 12[Torr].

  • PDF

Development of the DIW-$O_3$ Cleaning Technology Substituted for the Semiconductor Photoresist Strip Process using the SPM (SPM을 이용한 반도체 포토레지스트 제거 공정 대체를 위한 DIW-$O_3$ 방식 세정기술 개발)

  • Son, Yeong-Su;Ham, Sang-Yong
    • 연구논문집
    • /
    • s.33
    • /
    • pp.99-109
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DIW-$O_3$) in semiconductor wet cleaning process and photoresist stripping process to replace the conventional sulfuric acid and hydro peroxide mixture(SPM) method has been studied. In this paper, we propose the water-electrode type ozone generator which has the characteristics of the high concentration and purity to produce the high concentration DIW-$O_3$ for the photoresist strip process in the semiconductor fabrication. The proposed ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. Through this study, we obtained the results of the 10.3 wt% of ozone gas concentration at the oxygen gas of 0.5 [liter/min.] and the DIW-$O_3$ concentration of 79.5 ppm.. Through the photoresist stripping test using the produced DIW-$O_3$, we confirmed that the photoresist coated on the silicon wafer was removed effectively in the 12 minutes.

  • PDF

Development of a 9as-liquid two-phase flowmeter using double orifice plates (2중판 오리피스를 이용한 기액 2상유량계의 개발)

  • 이상천;이상무;남상철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.619-629
    • /
    • 1998
  • An experimental work was conducted to investigate a feasibility of simultaneous measurement of gas-liquid two-phase flowrates with double orifice plates using air and water. The tests were carried out under the atmospheric pressure and at the ambient temperature using two different tube sizes. Qualities of an air-water flow in the present study have values less than 0.1 and thus the mixed flow showed bubbly, plug, slug flow regimes. The probability density function (PDF) and the power spectral density function (PSDF) of the instantaneous pressure drop traces for the flow regimes were obtained. It is found that some distinctive features exist in the distribution of these functions, depending upon the two-phase flow pattern. The time-averaged value of the instantaneous pressure drop increases with increasing gas and liquid flowrates, showing a single-valued function for the total mass flowrate and the quality. It is also found that the two-phase discharge coefficient exhibits a consistent trend for variation of dimensionless parameters such as the superficial velocity ratio and the gas Reynolds number. The results indicate that simultaneous measurement of two-phase flowrate may be possible based upon a statistical analysis of the instantaneous pressure drop curves monitored using double orifice plates.

  • PDF