• 제목/요약/키워드: Discharge Time Lag

검색결과 71건 처리시간 0.029초

A Study on the Relationships between Addressing Time and Cell Structure in AC PDP

  • Choi, Yoon-Chang;Choi, Joon-Young;Kim, Dong-Hyun;Lee, Ho-Joon;Shin, Joong-Hong;Park, Chung-Hoo
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 영호남 학술대회 논문집
    • /
    • pp.67-71
    • /
    • 2003
  • One of the most important problems in ADS method is that the method has too long addressing period, The addressing time can be defined as the sum of the discharge time lag and the duration of discharge current. If the addressing time increases, the sustaining period for display image should be decreased. As a result, the luminance of the PDP decreases. Therefore, the discharge time lag and duration of discharge current should be decreased in order to reduce the addressing time. In this paper, in order to improve addressing time, relationships between addressing time and cell structure in AC PDP was studied

  • PDF

Discharge characteristics of MgO-PDP manufactured by using "all-in-vacuum" process

  • Yano, T.;Uchida, G.;Uchida, K.;Awaji, N.;Shinoda, T.;Kajiyama, H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.28-30
    • /
    • 2009
  • PDP panels with MgO protective layer are manufactured by using the "all-in-vacuum" process we have established [1]. This is the process aiming to keep the MgO surface as clean as possible after the evaporation. The panels are evaluated in term of discharge voltage, aging time, luminance, luminous efficacy, discharge time-lag. It is confirmed that the "all-in-vacuum" process particularly improves the aging time, discharge voltage and the discharge time-lag.

  • PDF

Discharge Characteristics in Soils Subjected to Lightning Impulse Voltages

  • Kim, Seung Min;Yoo, Yang-Woo;Lee, Bok-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.446-454
    • /
    • 2016
  • In this paper, we present experimental results of the soil discharge characteristics as a function of moisture content when a 1.2/50-㎲ lightning impulse voltage is applied. For this study, laboratory experiments were carried out based on factors affecting the transient behavior in soils. The electrical breakdown voltages in soils were measured for a 0-6% range of moisture content for sand and a 0 - 4% range of moisture content for gravel. A test cell with semi-spherical electrodes buried face-to-face in the middle of a cylindrical container was used. The distance separating the electrodes is 100 mm. As a result, the time-lag to breakdown in soils decreases as the amplitude of applied voltage increases. The time-lag to initiation of ionization streamer is decreased, with an increase in the moisture content. However, the formative time-lag is rarely changed. The behavior of soil discharges depend not only on the type of soil and its moisture content but also on the amplitude of the impulse voltage. When the test voltage is applied repeatedly, electrical breakdown occurs along different discrete paths, leading radially away from the injected electrode. i.e., the fact that the ionization streamers propagate in different paths from shot to shot was observed.

Characteristic of a Negative Driving Waveform in ac PDPs

  • Kang, Jung-Won
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.97-100
    • /
    • 2009
  • A negative waveform was studied to improve the driving characteristics of reset and address periods in ac PDP. Comparative experiments between negative and conventional positive waveforms were performed with 42-inch XGA PDP module. The negative waveform showed lower breakdown voltage than the conventional positive waveform in reset period. Due to its weak and stable discharge during reset period, the contrast ratio was improved by decreasing the black luminance. During address period, the discharge time-lag was measured. The formative time lag ($=T_f$) of negative waveform was improved about 22.8% than $T_f$ of conventional positive waveform.

  • PDF

Study of AC-PDP's Discharge Characteristics with Variation time and Temperature in High Xe contents

  • Kim, Hyun-Gyu;Lee, Ho-Jun;Kim, Dong-Hyun;Park, Chung-Hoo;Cho, Sung-Yong;Ha, Chang-Seung;Wi, Sung-Suk;Sim, Choung-Hwan;Lee, Hae-June
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.732-735
    • /
    • 2009
  • In this paper, high Xe(Ne+Xe 10%, 20%, 30%) AC-PDP's discharge characteristics according to aging time were studied. The static margin, Vt close curve, discharge time lag was measured for experiments. According to increase of Xe partial pressure, the static margin and luminance was increased. As the result of analysis for misfiring probability, the misfiring is frequently occurred in accordance with increasing of aging time. To improve misfiring, we proposed 3Reset waveform and achieved misfiring probability which was improved.

  • PDF

ac PDP에서의 Reset과 Address 구간에서 Negative Waveform특성에 관한 연구 (A Study of Negative Waveform in ac PDP during Reset and Address Periods)

  • 엄철환;강정원
    • 반도체디스플레이기술학회지
    • /
    • 제8권1호
    • /
    • pp.27-31
    • /
    • 2009
  • A characteristic of new waveform, called a negative waveform, was studied during reset and address periods. IR distribution, black luminance and time delay were measured to compare the negative waveform with the conventional positive waveform. Based on the analysis of IR measurement, the negative waveform could accumulate more wall charges than the positive waveform. Also the black luminance of negative waveform was lower than that of positive waveform under the same bias and ramp-slope conditions. During address period, the discharge time lag was measured. The negative waveform was showed 0.25 us faster formative time lag and 0.1 us faster average time lag than those of positive waveform.

  • PDF

하전 입자 효과를 이용한 Plasma Display Panel의 고속 구동 파형에 관한 연구 (Studies on High Speed Addressing Driving Scheme using the Priming Effect in Plasma Display Panel)

  • 신범재;박상식
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.45-52
    • /
    • 2009
  • 본 연구는 Full-HD급 PDP의 고속 구동 구현을 위한 새로운 구동 방식에 관한 연구이다. 새로운 SPA (self-priming address) 구동 파형은 어드레스 구간에서 지속적인 프라이밍 방전을 유지하여 하전 입자 효과를 이용하여 어드레스 방전 지연 시간을 개선하기 위하여 제안되었다. 본 연구에서는 프라이밍 방전의 기본 특성에 대해 조사하였으며, 안정적인 프라이밍 방전을 유지할 수 있는 초기화 펄스 및 프라이밍 램프 펄스를 도출하였다. 특히, 프라이밍 램프 펄스의 기울기가 0.1[$V/{\mu}s$]의 미약한 프라이밍 방전의 경우에 대해서도 기존 방식의 1.2[${\mu}s$]의 어드레스 방전 지연 시간을 0.8[${\mu}s$]로 획기적으로 개선할 수 있는 것을 확인하였다.

Comparative Study on the Runoff Process of Granite Drainage Basins in Korea and Mongolia

  • Tanaka, Yukiya;Matsukura, Yukinori
    • 한국제4기학회지
    • /
    • 제17권2호
    • /
    • pp.79-84
    • /
    • 2003
  • This study revealed the differences in runoff processes of granite drainage basins in Korea and Mongolia by hydrological measurements in the field. The experimental drainage basins are chosen in Korea (K-basin) and Mongolia (M-basin). Occurrence of intermittent flow in K-basin possibly implies that very quick discharge dominates. The very high runoff coefficient implies that most of effective rainfall quickly discharge by throughflow or pipeflow. The Hortonian overlandflow is thought to almost not occur because of high infiltration capacity originated by coarse grain sized soils of K- basin. Very little baseflow and high runoff coefficient also suggest that rainfall almost does not infiltrate into bedrocks in K-basin. Flood runoff coefficient in M-basin shows less than 1 %. This means that most of rainfall infiltrates or evaporates in M-basin. Runoff characteristics of constant and gradually increasing discharge imply that most of rainfall infiltrates into joint planes of bedrock and flow out from spring very slowly. The hydrograph peaks are sharp and their recession limbs steep. Very short time flood with less than 1-hour lag time in M-basin means that overland flow occurs only associating with rainfall intensity of more than 10 mm/hr. When peak lag time shows less than 1 hour for the size of drainage area of 1 to 10 km2, Hortonian overland flow causes peak discharge (Jones, 1997). The results of electric conductivity suggest that residence time in soils or weathered mantles of M-basin is longer than that of K-basin. Qucik discharge caused by throughflow and pipeflow occurs dominantly in K-basin, whereas baseflow more dominantly occur than quick discharge in M-basin. Quick discharge caused by Hortonian overlandflow only associating with rainfall intensity of more than 10 mm/hr in M-basin.

  • PDF

뇌임펄스전압에 의한 불평등전계에서 토양방전특성 (Soil Discharge Characteristics in Inhomogeneous Field Caused by Lightning Impulse Voltages)

  • 유양우;김승민;김유하;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권4호
    • /
    • pp.95-101
    • /
    • 2015
  • This paper presents experimental results about characteristics of soil discharge as a function of moisture content when the $1.2/50{\mu}s$ lightning impulse voltage is applied. The laboratory experiments, for this study, were carried out based on factors affecting the transient behavior in soils. The electrical breakdown in soils was measured over a 0-6% range of moisture content for sands and a 0-4% range of moisture content for gravels. Needle-plane electrode systems was used As a result, the conduction current prior to ionization growth in dry soil is a little, but it in wet soil is increased with the applied voltage because the wet soil particles act as conductors. The soil impedance curves show an abrupt reduction just after breakdown. The general tendency measured in different soils is that the higher the water content, the lower the breakdown voltage and the shorter the time-lag to breakdown.

플라즈마 디스플레이 패널의 고속 구동을 위한 세폭 펄스 어드레스 방전특성 (Discharge Characteristics of Narrow Width Pulse Addressing for the High-Speed Driving of Plasma Display Panels)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.13-19
    • /
    • 2007
  • 본 연구는 1,080개의 주사선수를 가지는 full-HD PDP를 위한 새로운 고속구동방식에 관한 것으로 고속 어드레스에 의한 표시방전의 방전특성을 고찰하여 새로운 구동방식의 특성을 평가하였다. 이 구동방식에서 어드레스 펄스의 폭이 좁아지면 최초 표시방전의 상대적 방전강도와 방전지연시간은 그 영향을 받는다. 어드레스 펄스의 인가위치의 변화는 방전강도와 무관하나 방전지연시간에는 영향을 미친다. 그러나 어드레스 펄스의 인가위치가 [$6{\mu}s$]이내이고 펄스의 폭이 [$0.7{\mu}s$]이내라면, 어드레스 펄스의 인가위치나 폭에 무관하게 안정된 표시방전을 유도할 수 있다. 실험결과로부터 폭이 좁은 어드레스 펄스를 사용하는 고속구동기술은 축적되는 벽전하의 부족으로 인해 공간전하의 영향에 매우 민감하다는 것을 알았다.