• Title/Summary/Keyword: Discharge Test

Search Result 1,596, Processing Time 0.031 seconds

Electric Field Analysis and Removal Characteristics of Escherichia Coli for Water Discharge Tube with Globular SiO$_2$ (구형 SiO$_2$를 갖는 수방전관의 전계 해석 및 대장균 제거 특성)

  • 이동훈
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.103-108
    • /
    • 2004
  • This paper shows the simulation of electric field distribution and removal characteristics of Escherichia coli for water discharge tube with globular $SiO_2$. At the experiments of the removing Escherichia coli used the discharge tube with globular dielectric($SiO_2$), because the electric field is increased when applied voltage is increased, the removed ratio of Escherichia coli was related with increasing of applied voltage. When a passing number of test water in water discharge tube is increased, the removed ratio of Escherichia coli is increased because passing number of territory with electric field is increased. When diameter of globular dielectric($SiO_2$) is increased, the removed time of Escherichia coli was decreased because electric field for dielectric polarization of globular dielectric($SiO_2$) was increased. Also, the removed ratio of Escherichia coli of the water discharge tube with globular dielectric($SiO_2$) was measured higher than the removal ratio of the discharge tube without globular dielectric($SiO_2$)

Removal characteristic of Escherichia coli for Discharge tube with globular $SiO_2$ (구형 $SiO_2$를 갖는 방전관의 수중 세균제거특성)

  • Lee, Dong-Hoon;Park, Hong-Jae;Park, Jae-Youn
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.546-549
    • /
    • 2003
  • This paper was shown removal characteristic of escherichia coli for discharge tube with globular $SiO_2$. At the result of the removal characteristic experiments of escherichia coli using the discharge tube with globular $SiO_2$, because the electric field is also increased when input voltage is increased, the removal characteristic of escherichia coli was appeared relation connection to input voltage. If a passing number of test water in discharge tube is increased, the removal ratio of escherichia coli is increased because passing number of electric field section is increased. When diameter of globular $SiO_2$ is increased, the removal time of escherichia coli is to be decreased because dielectric polalization of globular dielectric($SiO_2$), Also, the removal ratio of escherichia coli of the discharge tube with globular dielectric($SiO_2$) is appeared higher than the removal ratio of the discharge tube without globular dielectric($SiO_2$).

  • PDF

Removal characteristic of Escherichiacoli and water property conversion for Discharge tube with globular $ZrO_2$ (구형 지르코니아를 갖는 수방전관의 수질성분변환 및 세균제거특성)

  • Lee, Dong-Hoon;Park, Hong-Jae;Park, Jae-Youn
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.550-553
    • /
    • 2003
  • This paper was shown water properly conversion and removal characteristic of escherichia coli for discharge tube with $ZrO_2$ beads. At the result of the removal characteristic experiments of escherichia coli using the discharge tube with $ZrO_2$ beads, because the electric field is also increased when input voltage is increased, the removal characteristic of escherichia coli was appeared relation connection to input voltage. And if a passing number of test water in discharge tube with $ZrO_2$ beads is increased, the removal ratio of escherichia coli is to be increased because passing number of electric field section is increased. And if diameter of $ZrO_2$ beads is increased, the removal time of escherichia coli is to be decreased because dielectric polalization of $ZrO_2$ beads. Also, the removal ratio of escherichia coli of the discharge tube with $ZrO_2$ beads. is appeared higher than the removal ratio of the discharge tube without $ZrO_2$ beads. And a salutation point of ozone and $H_2O_2$ generation density inner water was appeared near 60[min].

  • PDF

Discharge Capacity of Prefabricated Vertical Drain Confined In-Clay Under Long-Term Conditions (연직배수재 타설 후 장기간 경과된 지반의 통수성능)

  • Jeong, Sang-Guk
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.239-249
    • /
    • 2018
  • Typically, soft clay improvement is carried out using installation of PVD and surcharge method. According to circumstances, installed PVD has left for a long time due to the change in construction schedule. Therefore, for simulation of this kind of condition, discharge capacity tests were carried out under a series of temperature condition (30, 35, $40^{\circ}C$). The results indicated that under water confinement, the discharge capacities significantly reduced with elapsed time. And, the empirical equation by Miura and Chai (2000) was used for estimating the long-term in-clay discharge capacity. Based on the test results, it is recommended that in term of long-term discharge capacity, Miura and Chai's equation and reliability evaluation using discharge capacity tests under a series of temperature condition may be used.

Phytoplankton Community and Surrounding Water Conditions in the Youngsan River Estuary: Weekly Variation in the Saltwater Zone (영산강 하구의 식물플랑크톤 군집 및 수 환경: 해수역의 주별 변동)

  • Sin, Yongsik;Yu, Haengsun
    • Ocean and Polar Research
    • /
    • v.40 no.4
    • /
    • pp.191-202
    • /
    • 2018
  • In this study we conducted a weekly monitoring exercise at a fixed station in the saltwater zone during the dry season (Jan-Mar, 2013) and wet season (Jun-Aug, 2013) to understand the fluctuations in phytoplankton communities and environmental factors in the Youngsan River estuary altered by a dike constructed in the coastal area. Phytoplankton communities displayed seasonality; diatoms were dominant during the dry season whereas dinoflagellates were dominant during the wet season. T-test analysis showed that water temperature was significantly different between the seasons whereas freshwater discharge from the dike was not significantly different. This suggests that seasonal variations of phytoplankton are more likely affected by water temperature than freshwater discharge. However, a short-term fluctuation was also observed in response to freshwater discharge; freshwater species appeared during or after the discharge in the dry and wet seasons and blooms of harmful species developed after the discharge. Phytoplankton communities may be affected by changes in physical factors such as turbidity and salinity and nutrient supply resulting from freshwater discharge. Especially, the nutrient supply may directly contribute to the harmful algal blooms (HABs) composed of dinoflagellates which can adapt to low salinity after freshwater discharge.

Analysis and Comparison of Flow Rate Measurements Using Various Discharge Measuring Instrument and ADCP (다양한 유량 측정기기와 ADCP를 이용한 유량 비교 분석)

  • Ji, Ju-Yeon;Park, Seung-Yong;Lee, Gwang-Woo;Park, Gyeong-Min;Hwang, Soon-Hong;Kim, Dong-Ho;Lee, Young-Joon
    • Journal of Environmental Science International
    • /
    • v.22 no.2
    • /
    • pp.251-257
    • /
    • 2013
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980's. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002, FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was $10.412m^3/s$, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.

Optimization of Lithium in Li1+x[Mn0.720Ni0.175Co0.105]O2 as a Cathode Material for Lithium Ion Battery

  • Kim, Jeong-Min;Jeong, Ji-Hwa;Jin, Bong-Soo;Kim, Hyun-Soo
    • Journal of Electrochemical Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.97-102
    • /
    • 2011
  • Different amounts of excess lithium in the range of x = 0~0.3 were added to $Li_{1+x}[Mn_{0.720}Ni_{0.175}Co_{0.105}]O_2$ cathode materials synthesized using the co-precipitation method to investigate its microstructure and electrochemical properties. Pure layered structure without impurities was confirmed in the XRD pattern analysis and increasing peak intensity of $Li_2MnO_3$ was observed along with the addition of over 0.2 mol Li. The initial discharge capacity of the stoichiometric composition was determined to be 246 mAh/g, while the discharge capacity of the addition of 0.1 mol Li was obtained to be 241 mAh/g, which was not significantly different from that of the stoichiometric composition. However, the discharge capacities decreased dramatically after the addition of 0.2 and 0.3 mol Li to 162 mAh/g and 146 mAh/g, respectively. In the rate capability test, the active $Li_{1+x}[Mn_{0.720}Ni_{0.175}Co_{0.105}]O_2$ cathode material of the stoichiometric composition showed a dramatic decrease in its discharge capacity with increasing C-rate, as evidenced by the result that the discharge capacity at 5C was 13% compared with 0.1C. On the other hand, the discharge capacity of compositions containing excess lithium was improved at higher current rates. The cycling test showed that the composition containing an excess of 0.1 mol Li had the most outstanding capacity retention.

Influence of Social Support and Illness Perception on Depression among Hospitalized Older Adults Prior to Discharge from an Acute Care Hospital (퇴원을 앞둔 노인 환자의 사회적 지지와 질병지각이 우울에 미치는 영향)

  • Yeom, Jeung Heui;Shin, Yong Soon
    • Korean Journal of Adult Nursing
    • /
    • v.29 no.3
    • /
    • pp.246-255
    • /
    • 2017
  • Purpose: This study was designed to identify factors affecting depression among hospitalized older adults prior to discharge from an acute care hospital. Methods: This descriptive study included adults aged 65 or older who were hospitalized in a general hospital in Seoul, Korea. Depression was measured by the Short Form Geriatric Depression Scale and illness perception was evaluated by the Brief Illness Perception Questionnaire. Social support was examined using the Perceived Geriatric Social Support Scale. Data were collected from August 25 to October 12, 2015. Data analysis included descriptive statistics, independent t-test, Kruskal-Wallis test, Pearson's correlation coefficient, and hierarchical multiple regression. Results: Among a total of 120 participants, 57 patients (47.5%) experienced depression. Mean depression score was $7.37{\pm}3.67$. Depression was associated with illness perception (r=.53, p<.001), social support (r=-.19, p=.043), number of admission due to the recurrence (r=.31, p=.001), and time to recognize discharge plan (r=.25, p=.044). In hierarchical multiple regression, illness perception (${\beta}=.45$, p<.001) and time to recognize discharge plan (${\beta}=.21$, p=.039) were predictors of depression (F=7.68, p<.001, Adjusted $R^2=.38$). Conclusion: The findings of this study suggest that management of illness perception and timely notice of discharge are important to reduce depression in hospitalized elderly patients.

A quantification study of blood test results for dyspnea patients (호흡곤란 환자에 대한 혈액검사 결과들의 수량화 연구)

  • Park, Cheol-Yong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.22 no.3
    • /
    • pp.477-485
    • /
    • 2011
  • Park et. al (2010) proposed a statistical model for determining the admission or discharge of 668 patients with a chief complaint of dyspnea by the number of 11 blood tests belonging to the corresponding discharge intervals. Since this method does not take into consideration the importance of each blood test result, its performance might not be optimally good. In this study, we employ a quantification method to evaluate the importance of those blood test results, and then provide a new statistical mode that takes the importance into consideration. The results show that the performance of this new model is a little better than that of the model by Park et. al (2010).

Turbine discharge measurement case study using ASFM system (ASFM을 이용한 수차유량의 측정)

  • Kim, Eung-Tae;Jeong, Yong-Chea;Park, Jang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.49-52
    • /
    • 2006
  • should be in English, A make out an economical, reliable and easy to adoptable instrument in turbine discharge measurement was restricted from lots of it's foundational condition. Not with standing the brilliant progress in new technology of these day, useful instrument for flow measurement in turbine is still ongoing. Nowaday, the increasing importance of renewable energy makes it more important that the measuring turbine efficiency as a decision making index of old turbines' replacement. In Turbine performance diagnosis, Kwater(Korea Water Corporation) got an enough ability and decent reputation for who has invested lots of time and effort for buildup and development. In Korea as a public corporation who should take a crucial roll in Turbine business, Kwater has introduced some developed new technology for other domestic concerned one. With this writing, I'd like to introduce ASFM system as a newly developed instrument that can cope with lots restriction in discharge measurement in turbine. Kwater adopted the system in 2005, and performed 2 times of trial test. The test result was good enough to use the system as a reference test method.

  • PDF