• 제목/요약/키워드: Discharge Measurements

검색결과 398건 처리시간 0.03초

지표유속법 기반 제주 산지형 하천 Kalesto 유량 정확도 향상 기법 (Enhancement Technique of Discharge Measurement Accuracy Using Kalesto Based on Index Velocity Method in Mountain Stream, Jeju Island)

  • 김동수;양성기;김수정;이준호
    • 한국환경과학회지
    • /
    • 제24권4호
    • /
    • pp.371-381
    • /
    • 2015
  • In the mountain streams in Jeju Island, strong turbulence and roughness usually made it nearly impossible to utilize most of intrusive instrumentation for streamflow discharge measurements. Instead, a non-intrusive fixed electro-magnetic wave surface velocimetry (fixed EWSV: Kalesto) became alternatively popular in many representative streams to measure stream discharge seamlessly. Currently, Kalesto has shown noteworthy performance with little loss in flood discharge measurements and also has successfully provided discharge for every minute. However, Kalesto has been operated to regard its measured one-point velocity as the representative mean velocity for the given cross-section. Therefore, it could be highly possible to potentially encompass discharge measurements errors. In this study, we analyzed the difference between such Kalesto discharge measurements and other alternative concurrent discharge measurements such as Acoustic Doppler Current Profiler (ADCP) and mobile EWSV which were able to measure velocity in multi-points in the cross-section. Consequently, Kalesto discharge deviated from ADCP discharge in amount of 48% for relatively low flow, and more than 20% difference for high flow compared with mobile EWSV discharge measurements. These results indicated that the one-point velocity measured by Kalesto should be used as a cross-sectional mean velocity, rather it should be accounted for as an index-velocity in conjunction with directly measured cross-sectional mean velocity by using more reliable instrumentations. After inducing Kalesto Discharge Correction Coefficient (KDCC) that actually means relationship between index velocity and cross-sectional mean velocity, the corrected discharge from Kalesto was significantly improved. Therefore, we found that index velocity method should be applied to obtain better accuracy of discharge measurement in case of Kalesto operation.

전자파와 수표면 영상을 이용한 산지하천 홍수유량 및 유속 계측 비교 연구 (Comparison of Flood Discharge and Velocity Measurements in a Mountain Stream Using Electromagnetic Wave and Surface Image)

  • 양성기;김동수;류권규;강명수;정우열;이준호;김용석;유호준
    • 한국환경과학회지
    • /
    • 제21권6호
    • /
    • pp.739-747
    • /
    • 2012
  • Due to the difficulties for measuring flood discharge in the dangerous field conditions, conventional instruments with relatively low accuracy such as float still have been widely utilized for the field survey. It is also limited to use simple stage-discharge relationship for assessment of the flood discharge, since the stage-discharge relationship during the flood becomes complicated loop shape. In recent years, various non-intrusive velocity measurement techniques such as electromagnetic wave or surface images have been developed, which is quite adequate for the flood discharge measurements. However, these new non-intrusive techniques have little tested in the flood condition, though they promised efficiency and accuracy. Throughout the field observations, we evaluated the validity of these techniques by comparing discharge and velocity measurements acquired concurrently during the flood in a mountain stream. As a result, the flood discharge measurements between electromagnetic wave and surface image processing techniques showed high positive relationship, but velocities did not matched very well particularly for the high current speed more 3 m/s. Therefore, it should be noted here that special cares are required when the velocity measurements by those two different techniques are used, for instance, for the validation of the numerical models. In addition, authors assured that, for the more accurate flood discharge measurements, velocity observation as well as stage height is strongly necessary owing that the unsteady flow occurs during the flood.

레이저를 이용한 방전 플라즈마중의 전계측정 기술 동향 (Technical tendency of electric field measurements in glow discharge plasmas using laser spectroscopy)

  • 최영욱;;촌강극기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1663-1665
    • /
    • 1997
  • Direct measurements of electric fields in a glow discharge are difficult because the measurement method should be sensitive to the electric field and non-intrusive. Laser spectroscopy is very suitable in that it is non-intrusive and allow in-situ measurements to be made. In this report, the measurement techniques of electric fields in glow discharge using laser spectroscopy were described.

  • PDF

양산천 수위-유량관계 특성에 관한 연구 (A Study on Characteristics of Stage-discharge Relationship for Yangsan River)

  • 이용희;이상배
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 춘계학술대회논문집
    • /
    • pp.91-98
    • /
    • 2000
  • Derivation of stage-discharge relationship and characteristics for Yangsan river is presented in this paper. This research has been conducted as the second one after the first trial of 1997. The determination of discharge at a Yangsan river gauging was best made by measuring the flow velocities with a current meter and rod float. The rating curve obtained through 52 stage-discharge measurements on Yangsan river basin in 1999 is represented by Q=15.3540-140.6076H+182.44372$H^2$, which is discovered to be most excellent among other curves in reliability analysis. The capability of the observed stage-discharge data for Yangsan river was tested by HEC-RAS program, and its capability to reproduce discharge was investigated and compared with the computational results. Rating curve stability is determined on the basis of deviations in the stage-discharge relationship, utilization of specific gauge, and absolute differences between sequential stream flow measurements and an analysis residuals. Therefore it seems necessary to research method to obtain rating curve in a rigorous and accurate manner.

  • PDF

Laves phase계 수소저장합금의 전기화학적 수소화 반응 매카니즘에 관한 연구 (A Study on the Electrochemical Hydrogenation Reaction Mechanism of the Laves Phase Hydrogen Storage Alloys)

  • 이지열;김찬중;김대용
    • 한국수소및신에너지학회논문집
    • /
    • 제8권1호
    • /
    • pp.31-41
    • /
    • 1997
  • In order to investigate the mechanism of electrochemical hydrogenation reaction on Zr-based Laves phase hydrogen storage alloy electrodes, electrochemical charge/discharge characteristics, potentiostatic/dynamic polarizations and electrocehmical impedance spectroscopy(EIS) of Zr-Ti-Mn-Ni and Zr-Ti-Mn-Ni-M(M=Fe, Co, Al) alloys were examined. Electrochemical discharge capacities of the alloys were quite different with gas charge capacities. Therefore, it was considered that discharge capacities of the alloys depend on electrochemical kinetic factors rather then thermodynamic ones. Discharge efficiencies were increased linearly with exchange current densities. The results of potentiostatic/dynamic polarization measurements showed that electrochemical charge and discharge reaction of Zr-based Laves phase hydrogen storage alloys is controlled by charge transfer process at the electrode surface. The EIS measurements also confirmed this result.

  • PDF

Partial Discharge Measurements of Artificial Defects in HTS Transformer Model using HFCT

  • Lee, S.H.;Shin, W.J.;Park, T.G.;Koo, J.Y.;Lee, B.W.
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.13-18
    • /
    • 2009
  • Partial discharge measurements in cryogenic dielectric materials of HTS transformer are very important because partial discharge was regarded as primary source for ageing and breakdown of cryogenic materials. But, partial discharge measurement techniques and its effects in low temperature high voltage environments were not suggested and there exist only a few reports on this research fields. Therefore, in order to implement reliable HTS transformers, partial discharge diagnosis techniques for cryogenic materials of HTS transformers were investigated using partial discharge (PD) pattern analysis methods. In this works, four different types of artificial defects including turn to turn insulation, free moving particle, void and protrusion, have been fabricated since it was commonly regarded that they might cause the sudden service failures of the power apparatus. For this purpose, these defects are installed into the dielectric materials in liquid nitrogen and experimental investigations have been carried out for the diagnosis of HTS transformer. And various PD patterns caused by the amount of quench of superconductors were analyzed. Throughout this works, the different PD patterns in cryogenic dielectric materials in liquid nitrogen, and PD measuring technique could be the fundamental steps to establish diagnosis technologies of HTS transformer for power applications.

  • PDF

분무 및 코로나 방전에 의해 대전된 서브마이크론 입자의 대전량 분포 (Charge Distribution of Submicron Particles Charged by Spray Electrification or Corona Discharge)

  • 이재복;배귀남;황정호;이규원
    • 대한기계학회논문집B
    • /
    • 제25권1호
    • /
    • pp.124-132
    • /
    • 2001
  • This paper reports on the charge distribution measurements of submicron particles for three different charging mechanisms, which are spray electrification, bipolar ionization and corona discharge process, respectively. The number of elementary charges per particle was investigated by classifying and counting of a discrete mobility class. Charge distribution measurements were performed with NaCl particles generated from a collision atomizer for 0.01, 0.1, 1% NaCl solutions. Experimental results show than charge level of atomized NaCl particles is high and decreases with increasing the dissolved ion concentration. The charge level of the atomized NaCl particles can be reduced to that o Boltzmann equilibrium conditions by the bipolar ionization(Po(sup)210 bipolar ionizer). The charge level on NaCl particles passing through the corona discharge reactor is much higher than those of atomized or bipolar ionized NaCl particles. The evaluation of these measurements results in charge distribution of the submicron particles.

고주파 유도방전 플라즈마 특성에 관한 연구( I ) (A Study on the Characteristics of the Radio-Frequency Inductive Discharge Plasma)

  • 박성근;박상윤;박원주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.63-66
    • /
    • 1996
  • Electron temperature and electron density were measured in a radio-frequency(rf) inductively coupled plasma using probe measurements. Measurements were made in an argon discharge for pressures from 10 to 100mTorr and input rf power from 100 to 800W. Spatial distribution Electron temperature and electron density were measured for discharge with same aspect ratio. Electron temperature and Electron density were found to depend on both pressure and power. Electron density was creased with increasing pressure, but peaked in a 70mTorr discharge. Radial distribution of the electron density was peaked in the plasma fringes. These results were compared to a simple model of inductively coupled plasmas.

  • PDF

가교폴리에틸렌(XLPE)의 부분방전에 의한 초음파 검출 (Detection of Ultrasonic Wave Signals Associated with Partial Discharge in XLPE)

  • 김성규;이상우;구경철;김충년;김인식;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.136-140
    • /
    • 1999
  • Measurements of AE signals caused by partial discharges were performed by using an ultrasonic measurement technique to diagonise the electrical treeing deterioration in XLPE cable. We also examined the partial discharge magnitude and AE signals(peak-to-peak) with the increase of the deterioration time. From these results, it was found that AE signal due to partial discharge can be greatly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of AE signals was closely related to the current pulses by the increase of deterioration, and it appeared that AE signals(peak-to-peak) was proportional to partial discharge magnitude. Attenuation and time-delaying characteristics of ultrasonic signals propagated in various polymers sample by using ultrasonic oscillation and receiving systems are also reported as a basic data of ultrasonic measurements in XLPE cable.

  • PDF