A Study on the Acting Load in the Vane Tip of Vane Pump for Design (베인펌프 설계를 위한 베인 선단부의 작용력에 관한 연구)

  • 정석훈
    • Tribology and Lubricants
    • /
    • v.19 no.6
    • /
    • pp.370-375
    • /
    • 2003
  • The radial acting load of vane on the camring in oil hydraulic vane pumps with and without intra­vanes have been investigated. The influences of the discharge pressure and rotating speed of the vane to the load were discussed. The variations of the radial acting load of a vane were calculated on the basis of the results measured for the dynamic internal pressure in the four chambers surrounding a vane. It provides essential information for the study of pump dynamics and control, the pump design and the analysis of tribological problems in the sliding components.

Unbalance load current of Operating in Parallel of Lead acid batteries connection condition (납 축전지 병렬운전시 발생하는 전류 불평형 현상분석 및 대책)

  • 반한식;곽철훈;최규하;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.210-213
    • /
    • 1999
  • A battery is the device that transforms the chemical energy into the direct-current electrical energy directly without a mechanical process. Unit cells are connected in series to obtain the necessary voltage, while being connected in parallel to organize capacity for load current and to decrease the internal resistance for corresponding the sudden shift of the load current. The circular-current, however, could be occurred when the system is driven in parallel. As a result, the new batteries are heated by over-change and discharge, and the over charge current makes to increase the rust of the positive grid and consequently the shortened life of the new batteris would be shown. In this paper, the internal resistance of charge and discharge will be balanced, through inserting the resistance into the system by way of calculation of the changed amount of internal resistance.

  • PDF

Mass Balance of Pollutants at a Paddy Field Area During Irrigation Period (관개기 광역논에서의 오염물질의 수지(지역환경 \circled3))

  • 오승영;김진수;김규성
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.617-622
    • /
    • 2000
  • Concentration of pollutants and discharge were monitored regularly at paddy field area during irrigation periods. The amounts of irrigation water during irrigation water during irrigation periods in 1999 were 3690mm. The concentration of pollutants in ponded water are high during fertilizer application period. The ratio of discharge of direct runoff Q$\_$D/ to the total runoff is 9%. The ratios of the load of direct runoff L$\_$D/ to the total load L$\_$T/ are 6% for T-N, 16% for T-P and 16% for COD. It was found that the ratios of the concentration are 0.7 for T-N, 1.8 for T-P and 1.9 for COD. The unit load of T-N, T-P and COD during irrigation periods were 12.1kg/㏊, 0.42kg/㏊ and 85.7kg/㏊, respectively

  • PDF

ASSESSMENT AND CONTROL OF TOTAL NUTRIENT LOADS IN WATERSHED AND STREAM NETWORK IN SOUTH-WEST TEXAS

  • Lee, Ju-Young;Choi, Jae-Young
    • Water Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • Recently, the population growth and agricultural development are rapidly undergoing in the South-West Texas. The junction of three river basins such as Lavaca river basin, Colorado-Lavaca Coastal basin and Lavaca-Guadalupe Coastal basin, are interesting for non-point and point source pollutant modeling: Especially, the 2 basins are an intensively agricultural region (Colorado-Lavaca Coastal/Lavaca-Guadalupe Coastal basins) and several cities are rapidly extended. In case of the Lavaca river basin, there are many range land. Several habitat types wide-spread over three relatively larger basins and five wastewater discharge regions are located in there. There are different hazardous substances which have been released. Total nutrient loads are composed of land surface load and river load as Non-point source and discharge from wastewater facilities as point source. In 3 basins region, where point and non-point sources of poll Jtion may be a big concern, because increasing fertilizers and pesticides use and population cause. This project objective seeks to how to assess and control the accumulation of non-point and point source and discuss the main impacts of agriculture and environmental concern as non-point source with water quality related to pesticides, fertilizer, and nutrients and as point source with wasterwater discharge from cities. The GIS technique has been developed to aid in the point and non-point source analysis of impacts to natural resource within watershed. This project shows the losses in $kg/km^2/year$ of BOD (Biological Oxygen Demand), TN (Total Nitrogen) and TP (Total Phosphorus) in the runoff from the surface of 3 basins. In the next paper, sediment contamination will show how to evaluate in Estuarine habitats of these downstream.

  • PDF

Influence of Current Waveform on Anode Erosion in Wire Electric Discharge Machining (와이어 방전가공에서 전류파형이 양극침식에 미치는 영향)

  • Cho, Sung-San;Oh, Jin-Hyuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.7
    • /
    • pp.127-133
    • /
    • 2001
  • The effects of triangular and rectangular discharge current waveforms on anode erosion in wire electric discharge machining is investigated based on heat transfer analysis of half-space subject to time and space-dependent heat flux. The thermal load on the anode is simulated by a hear flux that is calculated from time-dependent discharge channel radius and energy. Evolution of the melting front during discharge, the molten volume at the experimental result for qualitative verification of the analysis. It is demonstrated that the triangular current waveform is more efficient in eroding the anode than the rectangular one.

  • PDF

Design and Implementation of Fluid Flow Generation System by using Water Captures (물받이를 이용한 유수발전장치의 설계 및 구현)

  • Son, Young-Dae;Jung, Hyun-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.413-421
    • /
    • 2012
  • This paper proposes the design and implementation of fluid flow generation system by using polypropylene(PP) water capture, which harvests electric energy from the kinetic energy of tidal current or water flow and drives the desired load, and applies it to the discharge drain of Hadong thermal power plant. This experimental system is composed of water captures, driving wheel, gear trains, 10[kW] synchronous generator, and three phase rectifying circuit which drives lamp load for test. The proposed water capturing system which is composed of water captures, rope and driving wheel, rotates as caterpillar according to water flow. This system is very easy to manufacture and more economical than another type of tidal current turbines such as conventional propeller and helical type. Also, we estimated the available fluid flow energy that can be extracted from the cooling water in discharge drain based on drain's cross-sectional area. Therefore, this paper confirms the validity of proposed fluid flow generation system with water captures and the possibility of its application for renewable energy generation in discharge drain of thermal power plant, from the obtained performance characteristic of this energy conversion system.

Application of Nonlinear Dynamics and Wavelet Theory for Discharge and Water Quality Data in Youngsan River Basin (영산강 유역의 유출량 및 수질자료에 대한 비선형 동역학과 웨이블렛 이론의 적용)

  • Oh, Chang-Ryeol;Jin, Young-Hoon;Park, Sung-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.551-560
    • /
    • 2007
  • The present study analyzed noise reduction and long/short-term components for discharge, TOC concentration, and TOC load data in order to understand the data characteristics better. For the purpose, wavelet transform which can reduce noise from raw data and has flexible resolution in time and frequency domain was applied and the theory of nonlinear dynamics was also used to determine the last decomposition level for wavelet transform. Wavelet function of 'db10' and the 7th level for the last decomposition of wavelet transform were applied for the all data in the present study. Also the results revealed that the energy ratios of approximation components with 187-hour periodicity decomposed from 7th level of wavelet transform were 94.71% (discharge), 99.00% (TOC concentration), and 93.84% (TOC load), respectively. In addition, the energy ratios of detail components showed the range between 1.00% and 6.17%, which were extremely small comparing to the energy ratios of approximation components, therefore, the first and second detail components might be considered as noise components included in the raw data.

Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed (우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정)

  • Kim, Kyung-Tae;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong;Seong, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.

A Study on Estimated Pollutant Delivery Load for the Basic Plan of TPLC (수질오염총량관리계획 수립을 위한 유달부하량 추정방법 연구)

  • Hwang, Ha Sun;Rhee, Han Pil;Ahn, Ki Hong;Park, Ji Hyung;Kim, Yong Seok;Lee, Sung Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.4
    • /
    • pp.375-383
    • /
    • 2016
  • Total Pollution Load Control (TPLC) calculates and manages the allowable pollutant load that is discharged from the watershed, which can meet the water quality target. Delivery Ratio (DR) is generally used for predicting the variation of pollutant mass balance between the pollutants discharged from the watershed and a certain point in the stream, and it is very important for estimation of accurate allowable pollutant load. The concept of DR in TPLC is different from prevalent DR, because DR in TPLC includes both the discharge of pollutants from the watershed and the delivery mechanism. Therefore, DR in TPLC should be estimated by using a proper and unified methodology. The appropriate method and equation for estimation of DR in TPLC was developed through the review of various methodologies, and the applicability of the equation was evaluated in a study area (Geumho A). Determination coefficients (R2) of regression were shown to be relatively high (BOD 0.71~0.87, T-N 0.86~0.90, T-P 0.62~0.69). Applicability of the developed methodology and equations was evaluated as appropriate for TPLC, and it is suggested.

Evaluation of Discharge-Water Quality Characteristics and River Grade Classification of Jinwi River Unit Basin (진위천 단위유역의 유량-수질 특성 및 하천 등급화 평가)

  • Cho, Yong-Chul;Choi, Jin-Woo;Noh, Changwan;Kwon, Phil-Sang;Kim, Sang-hun;Yu, Soonju
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.704-716
    • /
    • 2018
  • The aim of this study is to examine the characteristics analysis of the discharge and water quality based on TPLMS (Total Pollution Load Management System) in the Jinwi River unit basin, and to propose a management plan by selecting the point that needs improvement of water quality in order to achieve the target water quality. We evaluated the discharge and water quality characteristics, statistical analysis, daily delivery load and daily delivery density, grade classification, for 14 total pollution load site's from 2014 to 2016 year in Jinwi river unit basin. The average discharge of Jinwi river unit basin is $22.411m^3/s$ and discharge of Hwangguji River is 32.8% and the water quality characteristics along the tributary river were clarified spatially. As the result, it was analyzed that Seongeun River is an indirect indicator of organic pollutants, Gwanri River is a seasonal factor, Osan River and Hwangguji River both affect water quality. Estimation of delivered pollutant loads at the HG-3 site was 6,470.4 BOD kg/day, 6,846.7 TN kg/day and delivered pollutant loads density increased to $220.9BOD\;kg/day/km^2$, $22.4TP\;kg/day/km^2$ at the HG-4 site. This result demonstrates that the total pollution load site needed to improve water quality of the Jinwi River unit basin was HG-3 site.