• Title/Summary/Keyword: Discharge Lamp

Search Result 309, Processing Time 0.025 seconds

The Characteristics of a fluorescent discharge lamp Type Ozonizer (형광 방전등형 오존발생기의 특성)

  • Lee, S.K.;Park, J.H.;Park, Y.K.;Chun, B.J.;Park, W.Z.;Lee, K.S.;Lee, D.I.;Song, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1756-1758
    • /
    • 2001
  • Recently, ozone is utilized in various fields and its needs are expanding. In this paper, fluorescent discharge type ozonizer has been designed and manufactured. Ozone discharge and generation characteristics have been investigated in accordance with a sort of internal electrodes, output voltage of power supply. flow rate and discharge power. Air has been used as the supplied gas of the ozonizer.

  • PDF

Analysis of Xe Plasma by LAS (레이저 흡수법을 이용한 제논 플라즈마 분석)

  • Yang, Jong-Kyung;Her, In-Sung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.220-222
    • /
    • 2005
  • We can classify two cases in a way to observe an atom of gas state or a molecule using the laser. First case is way to use dispersion phenomenon like Rayleigh scattering, Thomson scattering, Mie scattering, Raman Scattering. And Second case is a way to use change phenomenon like a LAS (Laser Absorption Spectroscopy), LIF (Laser Induced Fluorescent). In this paper, we have measured the meta-stable density and the distribution by using a LAS method in Xe discharge lamp. The laser absorption spectroscopy (LAS) is useful to investigate the behavior of such species. The xenon atoms in the $1S_4$ and $1S_5$ generate excited $Xe^*$(147nm) and $Xe_{2}^*$(173nm) dimers in Xe plasma. It is found that the intensity of VUV 147nm emission is proportional to that of the IR 828nm emission, and the VUV 173nm emission is roughly proportional to that of the IR 823nm emission. The laser is used CW laser that consist of AlGaAs semiconductor and energy level is used 823.16nm wavelength. We measured signal of monochrometer from the lamp center while will change a discharge electric current by 6mA in 3mA and calculated meta-stable state density of a xenon atom through a measured value.

  • PDF

Long Pulse Generation Technology of an Alexandrite Laser System for Hair Removal

  • Kim, Hee-Je;Park, Jin-Young;Kwak, Su-Young;Kim, Su-Weon;Min, Byoung-Dae;Jung, Jong-Han;Hong, Jung-Hwan
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.4
    • /
    • pp.155-160
    • /
    • 2003
  • In this study, an Alexandrite laser system for hair removal adopting a multi-discharge method in which three flash lamps are turned on consecutively was designed and fabricated to examine the pulse width and the pulse shape of the laser beams depending upon the changes in the lamp turn-on time. Specifically, this study demonstrates a technology that makes it possible to formulate various pulse shapes by turning on three flashlamps consecutively on a real-time basis with the aid of a PIC (program integrated circuit) one-chip microprocessor. With this technique, the lamp turn-on delay time can be varied more diversely from 0 to 10 ms and real-time control is possible with an external keyboard, enabling an assortment of pulse shapes. In addition, longer pulses can be more widely used for industrial processing as well as for numerous medical purposes.

Plasma Density Measurement of the Hg-Ar(1Torr) by LIF Method (LIF를 이용한 Hg-Ar(1Torr)의 플라즈마 밀도 측정)

  • Lee Jong-Chan;Park Dae-Hee;Yang Jong-Kyung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.213-217
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely This highlights the importance of measuring density distribution in plasma electric discharge mechanism study The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1 {\to} 6^3P_2$ ) were larger than 404.8nm ($6^3S_1 {\to} 6^3P_1$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

Plasma Density Measurement of Hg-Ar by LIF Method (LIF를 이용한 Hg-Ar의 플라즈마 밀도 측정)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Park, Kye-Choon;Song, Min-Jong;Kim, Hyeong-Gohn;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.27-32
    • /
    • 2006
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely. This highlights the importance of measuring density distribution in plasma electric discharge mechanism study. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorcscent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1{\rightarrow}6^3P_2$) were larger than 404.8nm ($6^3S_1{\rightarrow}6^3P_2$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

Low-Cost LED Driver Circuit using Power Factor Compensation Capacitor of Discharge Lamp (방전램프의 역률 보상용 콘덴서를 이용한 저가형 LED 구동회로)

  • Ko, Jae-Ha;Hwang, Jung-Goo;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.16-25
    • /
    • 2013
  • Now it's a trend to install a series of white fluorescent light and orange high pressure sodium lamps because tunnel lighting should be opaque to the safety of drivers from soot, dust, humidity, and fog. Also fluorescent lighting is replaced to LED due to the fact that it improves amenity and object recognition and LED lighting has gradually been improved its nature. In this paper, we have implemented the circuits of the yellow series of high-pressure sodium lamps and white series of LED lights at one board to improve the transparency and recognition of objects. It is possible for inductive high-pressure sodium lamps and the capacitive LED drivers to circuit without power factor compensation. Two circuit parts share only a small number of parts, so low cost LED drivers compared to conventional ones are possible. Therefore, the implementation of the hybrid lighting with high-pressure sodium lamps and LED lights that can be driven at the same time by one driving circuit is possible. The LED capacitive power factor was 0.91 while individually implemented the sodium lamp power factor was 0.98. It shows not only the 2% improvement of hybrid forms but also the efficiency and THD.

Development of a Pulse Light System for Treating Skin Pigmentation (피부의 색소치료를 위한 펄스 광 시스템의 개발)

  • Jeun, Jong-Baeg;Tack, Han-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.1
    • /
    • pp.81-87
    • /
    • 2021
  • In this study the skin care system was designed and tested by introducing V-IPL(Variable-Intense Pulse Light) methods that allow various skin treatments. The discharge method, a new method of switching on the flash lamp sequentially according to the lesions, was used. Pulse shape control is implemented in the system using the conventional LC variable method and the switching method control method of the switching element. As a result, the pulse width could be varied up to 1[㎛] by using a microprocessor, and by turning on the flash lamp sequentially along the lesions the depth and width, the pulse shape and pulse shape could be more diverse. We could also make long pulses of up to 1~100[ms] in various pulse width. And the special differences between the existing system and the proposed system in this study are as follow. Existing system is one pulse(pulse width : 1~40ms) and proposed system is three pulse(pulse width : 1~100ms).

A Study on the Automotive Structural Change of High Intensity Discharge Head lamp (자동차 전조등 고압 방전 램프 구조 변경에 대한 연구)

  • Lim, Ju-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.2
    • /
    • pp.53-60
    • /
    • 2008
  • A test was conducted using two high density discharge lamps, the H2D and the structurally new H4D. They were tested for luminous illumination and luminous temperature in the day and night time. The test was conducted without crippling the performance of the H2D by adding a magnetic actuator, enabling it to move left to right, and up and down. By making these modifications we constructed a sample of the H4D. We compared the H2D and the H4D sample's luminous illumination and luminous temperature by using a photometer and a digital thermometer in the day and night time. We discovered that the H2D and H4D performed similarly from the data we gathered. Now we know the H4D has potential use and extensive research needs to be made to gather more detailed data.