• Title/Summary/Keyword: Disc Insertion

Search Result 33, Processing Time 0.021 seconds

Dynamic Analysis and Validation of a Simulation in an Optical Disc Archive System During Disk Inserting (광 디스크 아카이브 시스템에서 디스크 삽입 상태의 동적 특성 분석 및 시뮬레이션 모델 검증)

  • Yoon, Joo Young;Oh, Wonseok;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.6_spc
    • /
    • pp.680-686
    • /
    • 2016
  • In an optical disc archive system, disc insertion process is an important part. Furthermore, dynamic analysis with the contact area between multi-bent leaf spring and a disc should be considered because the contact area is moved when the disc is inserted into the cartridge. In this paper, a finite element model of disc insertion was constructed based on dynamic characteristics, vertical stiffness, and dynamic response. The disc insertion model was validated with the experimental results. To identify the dynamic response of the disc induced by the changed contact area, applied force to the disc and the stiffness of the multi-bent leaf spring were analyzed. As the results, the factors which cause the failure of the disc insertion were investigated.

Method for C-arm Based Guide Needle Insertion Assistant System for Endoscopic Disc Surgery (C-arm 영상 기반 척추 디스크 내시경 수술을 위한 가이드 바늘 삽입 보조 시스템)

  • Yoon, Hyon Min;Cho, Hyunchul;Park, Kyusic;Shin, Sangkyun;Lee, Deukhee
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.3
    • /
    • pp.263-268
    • /
    • 2015
  • Due to an increased sitting time in work, lumbar disc disease is one of the most frequent diseases in modern days, and this occasionally requires surgery for treatment. Endoscopic disc surgery, one of the common disc surgeries, requires a process of inserting a guide needle to the target disc for which the insertion path is manually planned by drawing lines on the patient's skin while monitoring the fluoroscopic view of the lumbar. Such procedure inevitably exposes both surgeon and patient to the fluoroscopy radiation emitted from the c-arm for a long time. To reduce the radiation exposure time, this study proposes a computer assisted method of calculating the 3D guide needle path by using 2D c-arm images of the disc in 3 different angles. Additionally, a method of the guide robot control based on the 3D needle path was developed by implementing the Hand-eye Calibration method to calculate the transformation matrix between the c-arm and robot base coordinate systems. The proposed system was then tested for its accuracy.

Endovascular Treatment for Common Iliac Artery Injury Complicating Lumbar Disc Surgery : Limited Usefulness of Temporary Balloon Occlusion

  • Nam, Taek-Kyun;Park, Seung-Won;Shim, Hyung-Jin;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.261-264
    • /
    • 2009
  • Vascular injury during lumbar disc surgery is a rare but potentially life-threatening complication. It has been managed by open vascular surgical repair. With recent technologic advance, endovascular treatment became one of effective treatment modalities. We present a case of a 32-year-old woman who suffered with common iliac artery injury during lumbar disc surgery that was treated successfully by endovascular repair with temporary balloon occlusion and subsequent insertion of a covered stent. Temporary balloon occlusion for 1.5 hours could stop bleeding, but growing pseudoaneurysm was identified at the injury site during the following 13 days. It seems that the temporary balloon occlusion can stall bleeding from arterial injury for considerable time duration, but cannot be a single treatment modality and requires subsequent insertion of a covered stent.

Relationship between Temporomandibular Joint Disorders and Horizontal Morphology of Lateral Pterygoid Muscle (외측 익돌근의 수평적 형태와 측두하악관절장애 간의 상관성)

  • Jung, Jae-Kwang;Kwon, Choonik;Byun, Jin-Seok;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.149-159
    • /
    • 2013
  • The purpose of this study was to investigate the relationship between horizontal morphology of lateral pterygoid muscle and onset of temporomandibular joint disorders. Randomly selected 150 subjects, assigned with equal number in terms of gender and age group, were included. The axial and sagittal images in their magnetic resonance images of the temporomandibular joints were used to measure the morphologic characteristics of lateral pterygoid muscles and temporomandibular joints. The measurement variables were maximal horizontal width and insertion angle to the condyle, position of the articular disc, condylar deformity, and joint effusion. In addition, presence or absence of the temporomandibular joint pain was examined through history and palpation of the joints. The relationships among measurement variables were analyzed and the results were as follow. The insertion angle of the lateral pterygoid muscle to the condyle was higher in the joint of anterior disc displacement without reduction than that in the joint of normal disc position. In addition, the maximal horizontal width of the lateral pterygoid muscle was significantly increased in joints with pain than those without pain. Also, the insertion angle was significantly higher in younger age group and the maximal width was significantly greater in male than in female. These results suggest that high insertion angle of lateral pterygoid muscle might be an important anatomic predisposing factor for anterior disc displacement in temporomandibular joint and muscular activity of lateral pterygoid muscle might be affected by preauricular pain. In conclusion, there might be a bi-directional interaction between lateral pterygoid muscle and joint in the progression of anterior disc displacement in temporomandibular joint.

Implementation of Cervical Pedicle Surgical Guide for Safe Surgery

  • Kwak, Ho-Young;Huh, Jisoon;Lee, Won-Joo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.12
    • /
    • pp.125-130
    • /
    • 2017
  • Screw insertion surgery is frequently required among surgical procedures. Especially, very careful attention should be paid to the insertion of screw in the operation of the cervical vertebra. Therefore, there is a need for a guide that allows the surgeon to reliably and promptly perform treatment by calculating the desired insertion angle and length for screw insertion. In this study, the center and direction of the pedicle were calculated through 3D modeling and 3D vector numerical analysis using the CT or MRI image of the patient for the safe operation of the guide, and based on this, After that, we will implement surgical guide based on this.

Effects on the Adjacent Motion Segments according to the Artificial Disc Insertion (인공 추간판 적용으로 인한 인접 운동 분절의 영향)

  • Kim, Young-Eun;Yun, Sang-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.122-129
    • /
    • 2007
  • To evaluate the effect of artificial disc implantation and fusion on the biomechanics of adjacent motion segment, a nonlinear three-dimensional finite element model of whole lumbar spine (L1-S1) was developed. Biomechanical analysis was performed for two different types of artificial disc, ProDisc and SB $Charit{\acute{e}}$ III model, inserted at L4-L5 level and these results were also compared with fusion case. Angular motion of vertebral body, forces on the spinal ligaments and facet joint under sagittal plane loading with a compressive preload of 150 N at a nonlinear three-dimensional finite element model of Ll-S1 were compared. The implant did not significantly alter the kinematics of the motion segment adjacent to the instrumented level. However, $Charit{\acute{e}}$ III model tend to decrease its motion on the adjacent levels, especially in extension motion. Contrast to motion and ligament force changes, facet contact forces were increased in the adjacent levels as well as implanted level for constrained instantaneous center of rotation model, i.e. ProDisc model.

Rare Intractable Cervicalgia Related to Exaggerated Disc Height Distraction : Report of Two Cases and Literature Review

  • Choi, Man Kyu;Kim, Sung Bum;Lee, Jun Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.530-536
    • /
    • 2018
  • We present two cases of unexpected postoperative intractable cervicalgia due to over-sized implant insertion during simple anterior cervical decompression and fusion (ACDF) or artificial disc replacement (ADR). These patients experienced severe cervicalgia mostly related to their neck motion even after standard cervical operations. In both cases, the restored disc heights after the operations were prominently greater than the preoperative disc heights. The patients had not responded to any of the conservative treatments, and unloading of these excessively distracted segments through ultimate revision surgery led to dramatic pain relief. This report emphasizes the increase in distractional forces that takes place after a standard ACDF or ADR, as well as the importance of a proper sized implant. It also includes the reviews of other biomechanical or clinical reports dealing with this issue, thereby cautioning the surgeons not to disregard these factors, which might have an adverse effect in patients with cervicalgia even after radiographically successful cervical procedures.

Percutaneous Endoscopic Interlaminar Discectomy for L5-S1 Disc Herniation: Axillary Approach and Preliminary Results

  • Lee, Seung-Cheol;Lee, Sang-Ho;Choi, Won-Chul;Choi, Gun;Shin, Song-Woo;Kaul, Richard
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.2
    • /
    • pp.79-83
    • /
    • 2006
  • Objective : The purpose of this study was to describe a surgical technique of axillary approach of percutaneous endoscopic interlaminar discectomy for L5-S1 disc herniation and its preliminary results. Methods : From July 2002 to September 2003, 101 patients with lumbar radiculopathy due to L5-S1 disc herniation, who were treated by percutaneous interlaminar endoscopic discectomy, were retrospectively reviewed. There were 57 males and 44 females with a mean age of 44.8 years [range, 18 to 62 years]. The surgery consisted of needle insertion into the epidural space via the interlaminar space, sequential dilatation, and endoscopic discectomy through the axillary area of the S1 root. Results : The mean follow-up period was 14.5 months and the average surgical time was 41 min. According to the modified Macnab criteria, 44 patients [43.6%] had excellent outcomes, 49 [48.5%] had good results and only 8 [78%] had fair or poor outcomes. Four patients had a revision microdiscectomy due to incomplete removal of disc fragment. There were no major complications related to this surgical approach. Conclusion : Axillary approach of percutaneous endoscopic interlaminar discectomy is safe and effective procedure for the treatment of L5-Sl disc herniation. It combines the advantages of MED and conventional percutaneous endoscopic discectomy.

Sacral Meningeal Cyst Detected during Caudal Epidural Block (미추 경막외차단 도중 발견된 천추 수막낭 -증례 보고-)

  • Kang, Mi-Suk;Lim, Young-Jin;Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.12 no.2
    • /
    • pp.258-262
    • /
    • 1999
  • Sacral meningeal cyst is usually asymtomatic, but may be responsible for sciatic pain syndromes and other clinical symptoms. Sacral meningeal cyst might be suspected when definite explanation for the clinical symptom, such as herniation of the intervertebral disc or spinal stenosis is not found. Plain films and CT may suggest the presence of sacral meningeal cyst, but MR is the current imaging study of choice. Evaluation of the correlation between the symptom and the cyst is as important as detection of it. We have experienced a case of sacral meningeal cyst detected during caudal epidural block. The patient complained of low back pain radiating to thigh. Plain films and lumbar spine CT showed no remarkable finding except disc bulging. During caudal epidural needle insertion, there was leakage of clear CSF, and intrasacral cystic shadow was visualized by dye injection. MR confirmed sacral meningeal cyst.

  • PDF

The State of Clinical Trials on Acupotomy for Lumbar Disc Herniation in China (요추 추간판 탈출증에 대한 중국 내 도침 임상 연구의 현황 분석)

  • Jun, Purumea;Liu, Yan;Park, Ji-Eun;Jung, So-Young;Han, Chang-Hyun
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.27 no.2
    • /
    • pp.39-54
    • /
    • 2017
  • Objectives This study aimed to search the Chinese literature on acupotomy for lumbar disc herniation and to analyze their methodologies. Methods Using 4 Chinese databases (CBM [www.sinomed.ac.cn], CNKI [www.cnki.net], WANFANG [www.wanfangdata.com], and WEIPU [www.cqvip.com]), we searched for clinical trials conducted in China over the past 10 years on acupotomy for lumbar disc herniation. The search terms used were "(腰椎椎間板脫出症 or 椎間板脫出症 or 椎間板脫出) and (针刀or 针刀松解术)" and we selected only meta-analyses that were published before December 2016. From among these meta-analyses, we excluded duplicates and selected the remaining 36 randomized controlled trials (RCTs) for our final analysis. Results The largest numbers of acupotomy papers were published in 2008 and 2013 (8 papers each). The average number of subjects was 120; the most common treatment method used for the control group was standard acupuncture (in 11 papers), and the most common concurrent treatment in the treatment group was massage (in 10 papers). The most common site of needle insertion was between the spinous processes, or at less than 0.5 cm on either side of the spinous processes (in 24 papers). The most common site of adhesion lysis was at the transverse process (in 24 papers). Two studies were blinded, and the mean Jadad score was 1.17. Conclusions A large number of RCTs on the use of acupotomy for lumbar disc herniation are conducted every year in China, and the procedure has been shown to be very effective, with few adverse effects. However, the average quality of the studies was not very high. Based on our study, we expect several high-quality clinical trials on acupotomy to be conducted in Korea in the future.