• Title/Summary/Keyword: Disaster reduction

Search Result 685, Processing Time 0.024 seconds

Improvement plan and factual survey for weirs, drop structures and bridges in medium scale streams of Kyonggi province (경기도 지방하천에서의 보, 낙차공 및 교량 시설물의 실태 및 개선 방안 제시)

  • Noh, Huiseong;Ahn, Taejin
    • Journal of Wetlands Research
    • /
    • v.22 no.1
    • /
    • pp.31-38
    • /
    • 2020
  • Weirs are to secure amount water of streams and drop structures are to enhance stabilization of stream bed and bridges are to connect isolated region, which are called stream crossing structures. In the stream design criteria, directions for minimum size of structures are suggested to secure stability of stream crossing structures. However the sizes of almost all existing weirs and drop structures are not satisfied with the stream design criteria and only 22 percent of the peirs of bridges are satisfied. To enhance hydraulic stability of existing weirs and drop structures, it is required that the ratio of bed protection to apron should be above 3.3. According to factual survey of structures in the sample streams, it has been shown that the longitudinal slope of rapid works with 1:20 is the most reasonable to design velocity if existing weirs and drop structures are rehabilitated into rapid works. It has been known that violating freeboard and span length of piers should make existing bridges reconstructed or removed. However, comprehensive review including deterioration level of bridges, special regulation for span length, etc. should be considered to determine rehabilitation plan of bridges. In this study, a procedure has been suggested to improve hydraulic stability of weirs, drop structures and piers of bridges. Sound environment of stream and reduction of natural disaster could be achieved by improving stability of cross structures, which could be obtained by governmental budget and active stream management including observance of design criteria.

Combustive Properties of Medium Density Fibreboard (MDF) Specimens Treated with Alkylenediaminoalkyl-Bis-Phosphonic Acid Derivatives (알킬렌디아미노알킬-비스-포스폰산 유도체에 의해 처리된 중밀도섬유판의 연소성)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.57-63
    • /
    • 2014
  • This study was performed to test the combustive properties of Medium Density Fibreboard (MDF) specimens treated with piperazinomethyl-bis-phosphonic acid (PIPEABP), methylpiperazinomethyl-bis-phosphonic acid (MPIPEABP), and N,N-dimethylethylenediaminomethyl-bis-phosphonic acid (MDEDAP). MDF Plates were painted in three times with 15 wt% solution of the alkylenediaminoalkyl-bis-phosphonic acids at the room temperature, respectively. After drying specimen treated with chemicals, combustive properties were examined by the cone calorimeter (ISO 5660-1). It was indicated that the specimens treated with chemicals showed the later time to peak mass loss rate ($TMLR_{peak}$) = (340475) s than that of virgin plate by reducing the burning rate. In adition, the specimens treated with chemicals showed the higher $CO_{mean}$ production (0.0883~0.0963) kg/kg than that of virgin plate. Especially, the specimens treated with chemicals showed the higher mean smoke extinction area ($SEA_{mean}$) ($5m^2/kg{\sim}21.5m^2/kg$) than that of virgin plate. Thus, It is supposed that the combustion-retardation properties were improved by the partial due to the treated alkylenediaminoalkyl-bis-phosphonic acids in the virgin MDF Plate. However, It gave a negative effect on smoke reduction.

Portfolio Analysis on the New Power Generation Sources of the Sixth Basic Plan for Long Term Electricity Demand and Supply (포트폴리오 이론을 활용한 제6차 전력수급기본계획의 신규전원구성 비교 연구)

  • Kim, Juhan;Kim, Jinsoo
    • Environmental and Resource Economics Review
    • /
    • v.23 no.4
    • /
    • pp.583-615
    • /
    • 2014
  • Including the rolling black out in 2011, Korea has suffered from rapid increase of electricity consumption and demand forecasting failure for last five years. In addition, because of the Fukushima disaster, high fuel prices, and introduction of new generation sources such as renewables, the uncertainty on a power supply strategy increases. Consequently, a stable power supply becomes the new agenda and a revisino of strategy for new power generation sources is needed. In the light of this, we appraises the sixth basic plan for long term electricity demand and supply considering the changes of foreign and domestic conditions. We also simulate a strategy for the new power generation sources using a portfolio analysis method. As results, a diversity of power generation sources will increase and the share of renewable power generation will be surged on the assumptions of a cost reduction of renewable power sources and an increase of fuel costs. Particularly, on the range of a risk level(standard deviation) from 0.06 and 0.09, the efficient frontier has the most various power sources. Besides, the existing power plan is not efficient so that an improvement is needed. Lastly, the development of an electricity storage system and energy management system is necessary to make a stable and efficient power supply condition.

Effect of Fluorination and Ultrasonic Washing Treatment on Surface Characteristic of Poly(ethylene terephthalate) (불소화 및 초음파 수세가 폴리(에틸렌 테레프탈레이트) 필름의 표면 특성에 미치는 영향)

  • Kim, Do Young;In, Se Jin;Lee, Young-Seak
    • Polymer(Korea)
    • /
    • v.37 no.3
    • /
    • pp.316-322
    • /
    • 2013
  • In this study, poly(ethylene terephthalate) (PET) was treated with fluorination and ultrasonic washing treatment for hydrophilic modification of PET film. We measured the change of surface modified PET film surface characteristics using contact angle, surface free energy, FE-SEM, AFM and XPS. After direct fluorination and ultrasonic washing treatment, the water contact angle was measured to be $10.81^{\circ}$, 85% reduction compared to the untreated PET film. Total surface free energy has been measured to be $42.25mNm^{-1}$, 650% increase compared to the untreated PET film. Also RMS roughness has been measured to be 1.965 nm, 348% increase compared to the untreated PET film. Hydrophilic functional group C-OH bond concentration has increased approximately 3 times. These results are attributed to the hydrophilic functional group and cavitation due to chemical etching. From this result, it was suggested that the fluorination-ultrasonic washing treatment method could be useful to make PET film surface hydrophilic.

Development and Application of Automatic Rainfall Field Tracking Methods for Depth-Area-Duration Analysis (DAD 분석을 위한 자동 강우장 탐색기법의 개발 및 적용)

  • Kim, Yeon Su;Song, Mi Yeon;Lee, Gi Ha;Jung, Kwan Sue
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.4
    • /
    • pp.357-370
    • /
    • 2014
  • This study aims to develop a rainfall field tracking method for depth-area-duration (DAD) analysis and assess whether the proposed tracking methods are able to properly estimate the maximum average areal rainfall (MAAR) within the study area during a rainfall period. We proposed three different rainfall field tracking algorithms (Box-tracking, Point-tracking, Advanced point-tracking) and then applied them to the virtual rainfall field with 1hr duration and also compared DAD curves of each method. In addition, we applied the three tracking methods and a traditional GIS-based tool to the typhoon 'Nari' rainfall event of the Yongdam-Dam watershed and then assess applicability of the proposed methods for DAD analysis. The results showed that Box-tracking was much faster than the other two tracking methods in terms of searching for the MAAR but it was impossible to describe rainfall spatial pattern during its tracking processes. On the other hand, both Point-tracking and Advanced point-tracking provided the MAAR by considering the spatial distribution of rainfall fields. In particular, Advanced point-tracking estimated the MAAR more accurately than Point-tracking in the virtual rainfall field, which has two rainfall centers with similar depths. The proposed automatic rainfall field tracking methods can be used as effective tools to analyze DAD relationship and also calculate areal reduction factor.

Probable annual maximum of daily snowfall using improved probability distribution (개선된 확률밀도함수 적용을 통한 빈도별 적설심 산정)

  • Park, Heeseong;Chung, Gunhui
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.4
    • /
    • pp.259-271
    • /
    • 2020
  • In Korea, snow damage has happened in the region with little snowfalls in history. Also, accidental damage was caused by heavy snow leads and the public interest on heavy snow has been increased. Therefore, policy about the Natural Disaster Reduction Comprehensive Plan has been changed to include the mitigation measures of snow damage. However, since heavy snow damage was not frequent, studies on snowfall have not been conducted on different points. The characteristics of snow data commonly are not the same as the rainfall data. Some southern coastal areas in Korea are snowless during the year. Therefore, a joint probability distribution was suggested to analyze the snow data with many 0s in a previous research and fitness from the joint probability distribution was higher than the conventional methods. In this study, snow frequency analysis was implemented using the joint probability distribution and compared to the design codes. The results were compared to the design codes. The results of this study can be used as the basic data to develop a procedure for the snow frequency analysis in the future.

Analyzing Site Characteristics and Suitability for Wind Farm Facilities in Forest Lands (산지 내 풍력발전단지 입지 특성 및 적합성 분석)

  • Kwon, Soon-Duk;Joo, Woo-Yeong;Kim, Won-Kyung;Kim, Jong-Ho;Kim, Eun-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.4
    • /
    • pp.86-100
    • /
    • 2014
  • The purposes of this study are to provide a guideline for the suitability of wind farm facilities in forest lands and to suggest improvement plans of policies and systems to minimize the damage of forest lands. First, we implemented a literature review and field surveys to examine and select factors for the suitability of wind farm facilities in forest lands. Spatial database for selected location factors of wind farm facilities in forest lands was constructed to develop the suitability model for locating wind farm facilities focusing on Gangwon-do. Data used in this study include wind power resource, legal mountainous preserved area, forest roads, developed areas, forest class, and other spatial data. In order to find specific-sized potential areas for a certain number of wind farm turbines, we used block statistics and focal statistics methods. As a result, the areas for potential wind farm locations were 1,261ha from a block statistics method and 1,411ha from a focal statistics method. Based on the outputs of this research, it is required to make an urgent solution for the prevention of forest disaster and to prepare reduction measures for the destruction of ridge landscape.

Designing the Training Scenarios that Assuming Chemical Accidents in the Buildings and Analyzing Activities of Special Rescue Crew (건물 내부 화학사고를 가정한 모의 훈련 시나리오 설계 및 특수구조대원의 활동성 분석)

  • Kim, Si-Kuk;Hong, Sungchul
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.63-73
    • /
    • 2019
  • This study examined the activity of the simulated training scenarios and special rescue crew assuming a chemical accident inside the building. To improve the response ability and safety of rescue personnel in the event of a chemical accident, a total of eight stages of simulated training scenarios were conducted and the activity was measured. As a result of the activity measurement according to the simulation training scenario, the average maximum heart rate of the rescuers was the highest at 177.50 ppm in the 4th stage, and then 176.67 ppm for the 5th step, 171.17 ppm for the 2nd step, 169.33 ppm for the 3rd step, 162.17 ppm for the 6th step, 159.58 ppm for the 7th step, 148.75 ppm for the 8th step, and 139.33 ppm for the 1st step. The mean maximum respiratory rate was the highest at 38.17 rpm in the 4th stage, followed by 37.58 rpm in the 5th stage, 32.00 rpm in the 6th stage, 31.58 ppm in the 7th stage, 31.33 rpm in the 3rd stage, 31.08 rpm in the 2nd stage, and 28.00 rpm in the 8th stage. The 1st stage was 22.67 rpm. In addition, body water reduction measurements were reduced by up to 0.7 g due to the training intensity.

Effect Analysis on Emergency Vehicle Priority System for Securing Golden Time: Targeting on Cheongju City (골든타임 확보를 위한 긴급차 우선신호시스템의 효과 분석: 청주시를 대상으로)

  • Jeong, Keesin;Kim, Kitae
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.138-142
    • /
    • 2019
  • By securing golden time, this study analyzed the effects of an emergency vehicle priority system in Cheongju, North Chungcheong province. Until the scene of a fire is reached, severe obstacles in the street, such as traffic congestion, cars coming forward, non-cooperative vehicles etc., are significant. To solve these problems of road obstacles, it is essential to adopt an emergency vehicle priority system. From April 2017 to June 2018 (1 year and 2 months, 426 days), the dispatch time and date, fire truck moving distance and required time, traffic signal control section and pass time, and shortening time, were measured. This study selected 140 cases consisting of five heavy traffic and frequent dispatch routes out of 293 cases. The effects of the emergency vehicle priority system were excellent. Overall, it took 3 min 3 s to pass 1 km on an uncontrolled traffic signal section. On the other hand, it took 1 min 23 s to pass 1 km on the same section that was controlled. The shortening time to pass 1 km was 1 min 40 s, showing a 45.4% reduction. This means that the 15 min driving time can be reduced to 6 min and 49 s. From this result, an emergency vehicle priority system should be implemented nationwide as soon as possible.

A study on the action mechanism of internal pressures in straight-cone steel cooling tower under two-way coupling between wind and rain

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Yang, Q.;Wang, H.;Tamura, Y.
    • Wind and Structures
    • /
    • v.27 no.1
    • /
    • pp.11-27
    • /
    • 2018
  • The straight-cone steel cooling tower is a novel type of structure, which has a distinct aerodynamic distribution on the internal surface of the tower cylinder compared with conventional hyperbolic concrete cooling towers. Especially in the extreme weather conditions of strong wind and heavy rain, heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind, but existing studies mainly focus on the impact effect brought by wind-driven rain to structure surface. In addition, for the indirect air cooled cooling tower, different additional ventilation rate of shutters produces a considerable interference to air movement inside the tower and also to the action mechanism of loads. To solve the problem, a straight-cone steel cooling towerstanding 189 m high and currently being constructed is taken as the research object in this study. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed with continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind sped and rainfall intensity on flow field mechanism, the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower cylinder is analyzed. On this basis, the internal pressures of the cooling tower under the most unfavorable working condition are compared between four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the 3D effect of equivalent internal pressure coefficient is the most significant when considering two-way coupling between wind and rain. Additional load imposed by raindrops on the internal surface of the tower accounts for an extremely small proportion of total wind load, the maximum being only 0.245%. This occurs under the combination of 20 m/s wind velocity and 200 mm/h rainfall intensity. Ventilation rate of shutters not only changes the air movement inside the tower, but also affects the accumulated amount and distribution of raindrops on the internal surface.