Investigation on the operational state of the public food waste treatment facilities and suggestions on their efficient operational management (음식물류폐기물 공공 자원화시설의 운영실태 조사를 통한 처리공정별 효율적인 운영방안 검토)

  • Jang, Yun-Hyeok;Park, Joon-Seok;Kim, Joung-Dae;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.47-56
    • /
    • 2010
  • At present, 265 national food waste recycling facilities have been operated by public facilities 95 and private facilities 160. it has continuously installed a food waste treatment facility from 1997. The government set up and implemented guidelines and inspection standards for the installation and operation of the facilities. However, unclear detailed examination items, designs and process standards for the installation procedures of the facilities are causing problems due to the unskilled operation management system, decrease in efficiency and defects of a facility. This study conducted mail and site surveys on 95 public food waste recycling facilities that it suggest the ways to operate facilities which minimize problems. At the result of investigation, a pre-treatment facility was not installed 2 systems(2 inputting facilities) and hopper covers and food was overloaded. also the transportation amount was excessive. In case of a main treatment facility, the secondary environmental pollution was caused by inexperienced operation and the efficiency of the facility was reduced due to excessive input of food. also the operation management standards of the facilities were inappropriate. The odor and food waste leachate treatment facility is investigated as problems that are unskilled operation, lack of regular inspection and inappropriate capacity of the treatment facility. Based on the problems found through the investigation, it suggested some ways of efficient operation. this study might contribute to minimize mistakes and defects and improve the efficiency of install and operation course of food waste recycling facilities through finding.

Evaluation of Prevention System of Falls and Committing Suicide with Application Technology of Rollinder System (추락 및 투신자살 방지시스템의 조사 및 Rollinder System 적용기술)

  • Park, Sea-Man;Baek, Chung-Hyun;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.591-598
    • /
    • 2019
  • The statistics of committing suicide in S. Korea is ranked in top with serious attempts of falling among OECD countries since 2003. The rates is slightly dropped by 5 percent point, nevertheless the falling is still high for the age of over 10 years old and this matter must be solved. Most of the case of suicides are the falling based on a trend view of falling which is serious matter and cannot be solved easily for both domestic and foreign countries. For example, the steel net of falling prevent was installed in the Golden Gate Bridge costed by 200 million-dollar. In New Zealand, the steel net of falling prevention had been removed and re-installed beccause of the high suicide rates. Canada and Australia also surrounded the bridge with steel fences to prevent suicide without consideration of the beauty of bridge. Therefore, this paper suggested a comparison study on both falling prevention systems in all countries and patent technologies. Also, it covers the blocking skills of approach in both security and limited area. This paper suggested the technical Rollinder system equipped with the mechanical apprentice to prevent effectively the falling sucides and wall passing. Before the installation of Rollinder System by 2016, there were 33 person who tried to fall in the river in Machang Bridge. However, the number of the committing suicides were dramatically reduced to zero after the installation of the system.

A Study on the Safety Grounding for Prevention of Electric Shock Hazard in Construction of Industrial Plant in Maritime Landfill Area (해상 매립 지역 산업 플랜트 건설 시 감전 재해 예방을 위한 안전 접지에 관한 연구)

  • Kim, Hong-Yong;Jang, Ung-Burm
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.305-312
    • /
    • 2017
  • In our society, the advanced, advanced, and information industries have continued to grow and now live in the era of the fourth industrial revolution. As the industry develops, the load of the users has also increased so much that it is deepened by the energy shortage phenomenon and the construction of additional energy facilities is required. Therefore, energy plant construction work is being actively carried out in the coastal area. In particular, it is common to build a plant in the ground by filling the coast with soil in other regions, reflecting the fact that Korea is lacking in the country when constructing power plants, gas and petrochemical plants. Current domestic grounding designs are designed or constructed to suit only the use of grounding resistors based on the electrical equipment design technical standards. However, in the case of a plant facility constructed in the untested buried soil, when the lightning current and the abnormal current are inputted, the facility operator or the user due to the elevation of the ground potential is seriously exposed to the risk of electric shock disaster. In this paper, we analyze the ground resistivity of the landfilled soil and use a computer program (CDEGS) based on KS C IEC 61936-1, We analyze the contact voltage and stratification voltage and propose a grounding design optimized for plant installation.

Introduction and Classification System of Reservoir Park Mitigating Flood (홍수대응 다목적 재해대응 저류공원의 도입과 분류체계 연구)

  • Moon, Soo-Young;Jung, Seung-Hyun;Yun, Hui-Jae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.12
    • /
    • pp.646-659
    • /
    • 2018
  • This study proposed "Reservoir Park", which added disaster prevention function to urban green spaces such as city parks through domestic and overseas related laws review, case studies, field trips. This is a combination of urban parks and reservoirs as urban planning facilities, which can provide both space for daily use by urban residents and disaster mitigation functions in case of emergency. In order to prevent flooding in urban areas due to climate change, facilities should be installed in the form of parks, etc., as the reservoir facility should be systematically reviewed together with urban planning facilities. However it was found that the reservoir park was not clear as a theme park. In this study, the types of storage facilities in urban areas were reclassified into five types of storage parks reflecting the characteristics of urban green spaces through domestic case studies and field trips. The classification of the reservoir parks is classified into 5 kinds such as ecological type, vegetation cover type, exercise facility type, underground burial type and hybrid type based on groundwater level, human use, and reservoir size. This classification system can be used to determine the types of facilities to be built after designating the location of future storage facilities.

A Study on the Prevention of Lightning Accidents According to Climate Change Response (기후변화에 따른 낙뢰사고 예방을 위한 제도 방안 연구)

  • Ju, Suk-won;Kim, Seong-Bin;Rie, Dong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.48-55
    • /
    • 2020
  • The installation of lightning protection system has recently been increasing, but the amount of damage has still been increasing. In this study, survey (interview) and field conditions were conducted to identify the installation and safety standards of the lightning protection system. it was analyzed that the safety management system is non-existent at the stage of the design, manufacturing and construction of the site lightning protection system, and that the safety inspection of the lightning protection facility is not properly managed. It has been shown that lightning protection systems, that can solve these problems, need to be re-established according to the reality so that safety inspection can be carried out in accordance with safety standards such as management of safety certification products, operation of survey institutions, design, manufacturing, and construction of safety standards at a national level.

Multivariate Analysis of Fire Prevention Activities, Special Investigations of Fire Safety, and Fire Safety Management by the Apartment Buildings Management Methods and Inspection of Firefighting Facilities (공동주택 관리방식과 소방시설의 점검에 따른 예방활동·화재안전특별조사·소방안전관리의 다변량 분석)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.489-502
    • /
    • 2020
  • This study shows the difference between groups with multivariate analysis of fire prevention activities, special investigations of fire safety, and fire safety management according to the management method of apartment houses and the inspection of firefighting facilities. The results of the analysis are as follows. First, there was a significant difference in fire prevention activities according to the quality of inspection of firefighting facilities. This means that fire prevention is high if the fire safety manager's ability to inspect firefighting facilities is excellent and the fire safety inspection is conducted in accordance with national fire safety standards and checklists. Second, there was a significant difference in the fire safety special investigation according to the management method of the apartment buildings. The manual operated by the management entity and the management entity's management and execution help the organization members to expedite work. This expedition of work creates a high possiblity to get a good evaluation from the special investigation of fire safety. Third, analysis of fire prevention activities showed a significant interaction between the inspection of firefighting facilities and the management method of apartment buildings. The analysis shows that that there is a positive correlation between the level of fire prevention and both the fire safety manager's ability to inspect firefighting facilities and the degree to which the inspection is conducted to meet national fire safety standards.

The Effects of Apartment Facility Maintenance on the Residential Satisfaction of Residents (아파트 시설물 유지관리가 입주자의 주거만족도에 미치는 영향)

  • Kim, Myung-Hee;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.175-183
    • /
    • 2020
  • This study suggests a solution regarding the effects of apartment facility maintenance and fire safety facility maintenance on the residential satisfaction of residents. The results are as follows. Firstly, facility maintenance had a negative effect on residential satisfaction. Analysis revealed that residential satisfaction decreased the more breakdowns there were in the facilities. This revealed that when maintenance staff neglect the residents' complaints due to the repetitive aspect of their jobs, there was a negative effect on residential satisfaction; therefore, residential satisfaction must be increased by maintaining the facilities well and training support for maintenance staff. Secondly, fire safety facilities had a negative effect on residential satisfaction. Analysis revealed that residential satisfaction decreased the more malfunctions there were in the fire safety facilities and the more replacements there were in fire fighting equipment. This revealed the importance of safety and the fact that the apartment heavily relies on fire safety facilities because there may be a low awareness regarding safety; therefore, maintenance staff must lower the damage from fire safety facilities and to increase the residential satisafaction of residents. Lastly, there needs to be repetitive training and education for residents regarding fire fighting and evacuating in accordance with the fire fighting plan as a means to strengthen residents' safety awareness.

U-city Construction Topographic features Extraction by Integration of Digital Aerial Photo and Laser Data (항공사진과 레이져 데이터의 통합에 의한 U-city 건설 지형 특성 자료 산출 연구)

  • Yeon, SangHo;Kim, Kwanghyun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.485-487
    • /
    • 2009
  • The Spatial Image contents of Geomorphology 3-D environment is focused by the requirement and importance in the fields such as, national land development plan, telecommunication facility management, railway construction, general construction engineering, Ubiquitous city development, safety and disaster prevention engineering. The currently used DEM system using contour lines, which embodies geographic information based on the 2-D digital maps and facility information has limitation in implementation in reproducing the 3-D spatial city. Moreover, this method often neglects the altitude of the rail way infrastructure which has narrow width and long length. This As the results, We confirmed the solutions of varieties application for railway facilities management using 3-D spatial image contents and database design. Also, I suggested that U-city using topographical modeling about matching methods of high density elevation value using 3-D aerial photo with laser data are best approach for detail stereo modeling and simulation.

  • PDF

3-D modeling and Application Methods for Urban Areas by Convergence of Topographical Spatial Contents (지형공간 콘텐츠 융합에 의한 도시 및 지역의 3차원 모델링 및 활용기법 연구)

  • Yeon, SangHo;Lee, Youngwook
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.488-490
    • /
    • 2009
  • The Spatial Image contents of Geomorphology 3-D environment is focused by the requirement and importance in the fields such as, national land development plan, telecommunication facility management, railway construction, general construction engineering, Ubiquitous city development, safety and disaster prevention engineering. The currently used DEM system using contour lines, which embodies geographic information based on the 2-D digital maps and facility information has limitation in implementation in reproducing the 3-D spatial city. Moreover, this method often neglects the altitude of the rail way infrastructure which has narrow width and long length. This As the results, We confirmed the solutions of varieties application for railway facilities management using 3-D spatial image contents and database design. Also, I suggested that U-city using topographical modeling about matching methods of high density elevation value using 3-D aerial photo with laser data are best approach for detail stereo modeling and simulation. There for of this, Using of rapid spatial information generation by various images and laser data through matching methods for the make of Spatial data base management inplementation are very powerful and much application of our life and real worlds.

  • PDF

An Analysis on the Effect of Pressure System Installation on the Pipeline to Identify Pressurized Water and Self-inspection Ease in Apartment Building (아파트에 설치하는 옥내소화전 압력계 설치가 배관의 가압수 식별 및 자체점검 용이성 간의 영향 분석)

  • Son, Joo-Dal;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.33-44
    • /
    • 2020
  • This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study's results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building's stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system's internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.