• Title/Summary/Keyword: Disaster Management Class

Search Result 55, Processing Time 0.025 seconds

Prototype Development and Experimentation to Improve the Seismic Performance of Curtain walls (커튼월의 내진성능 향상을 위한 시제품 개발 및 실험)

  • Min, Byoung jun;Won, Jeong hun;Jeon Jin woo;Kang, Hyun Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.4
    • /
    • pp.14-24
    • /
    • 2023
  • The purpose of this study is to develop a prototype curtain wall with improved seismic performance and to verify the seismic performance by conducting an inter-floor displacement test. To this end, a prototype of the curtain wall was manufactured and a displacement similar to the earthquake load was induced, and then the damaged state of the curtain wall was checked. As a result of the first test, the frame and glass of the curtain wall were not damaged, but the Weather Sealant was partially damaged. As a result of the second test, there was no problem of glass breakage in seismic class (special), seismic class (I), seismic class (II), and AAMA 501.6. Through this experiment, the seismic performance of the curtain wall prototype was verified.

Study on the effective response method to reduce combustible metal fire (금속화재 위험감소 방안에 관한 이론적 연구)

  • Nam, Ki-Hun;Lee, Jun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.600-606
    • /
    • 2018
  • A class D fire or combustible metal fire is characterized by the presence of burning metals. Only certain metals or metal compounds are flammable, including sodium and lithium. General fire extinguishing agents, such as dry chemical powder, water-based fire extinguish agents, and carbon dioxide, cannot be used in class D fires. This is because these agents cause adverse reactions or are ineffective. In addition, the amount of usage of combustible metals is increasing due to continuous development of the semiconductor and fuel cell industries. Despite this, Korea does not have standards and laws related to combustible metal fires. This paper suggests directions of the class D fire management policies to reduce the class D fire risk and impact by analyzing the standards and laws related to class D fires and combustible metal fire cases. The factors to make laws on class D fire prevention and response systems, and management system of dry sand were determined. These results may be used to help reduce the risk of class D fires and improve the response abilities.

Propose an Improvement of Checklist for Actual Condition Survey for Designation of Class-lll Facilitie (제3종시설물 지정을 위한 실태조사 체크리스트 개선방안)

  • Yoon, Ji-Ho;Jang, Myunghoun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.100-101
    • /
    • 2021
  • Facilities with high risk of a disaster or requiring continuous safety management are designated as class-III facility. In order to designate a class-III facility, it is evaluated based on the safety status of the facility, the risk to the building users, and the number of years elapsed of the facility, etc. and this shall be referred to the actual condition survey for the designation of a class-III facility. In the actual condition survey conducted to designate the safety status is calculated by the checklist based on the evaluation scores consisting of five stages each item, and is evaluated in three stages by 'good', 'careful observation', and 'designated review' through the average of the combined scores. Currently, the actual condition survey being conducted applies only structural stability, and the risk factors such as damage to the finish, the risk of cracking, and the type and weight of major structures are not included in the checklist for the actual condition survey, so even if experts think it is dangerous, scores cannot be reflected. Therefore, this study aims to analyze the problems of checklist of the actual condition survey for the designation of class-III facility and to propose an improvement plan for the checklist for the actual condition survey.

  • PDF

An Improvement of Security for the National Assembly (국회시설보안 향상방안)

  • Chung, Taehwang
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.290-299
    • /
    • 2013
  • This study is to present an improvement of security for the National Assembly by survey of persons who use the National Assembly facilities. Most of respondent said that their security consciousness level is above average, and they know National Assembly building is National Major Facility First class but they did not know well what the Major Facility First class is. Many of respondents thought security design of National Assembly building is inadequate, so reinforcement of access control management is necessary. For reinforcement of access control management, security gate and preparing of some obstacles are required. They said that they could put up with inconveniences incurred as a result of reinforcement of access control management, that could be affected positively for the reinforcement. The recognition on the necessity of security education is high, but there is no proper security education program. For practical security education, contents and different method followed by different facilities user should be considered.

A Study on the Improvement of Dangerous Goods Safety Management in Maritime Terminal (항만 옥외저장소 위험물의 안전관리 개선 방안)

  • Lee, Bong-Woo;Shin, Se-Cheol;Park, Kyung-Jin;Choina, Yeong-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.393-401
    • /
    • 2020
  • According to the research and investigations performed on Port Facilities for cargo-works of hazardous materials around the Port of Busan, a conclusion was drawn that the manually operating foam tower monitors are ineffective as they are hard to access due to the radiant heat under contingency circumstances such as a fire. Moreover, in some cases, the effective range of Foam Tower Monitors are insufficient to reach docked ships and manifolds where hazardous materials are being unloaded. In addition, Dangerous Goods freights are inadequately and inefficiently stored regardless properties of hazardous substances due to complicated local regulations, and some are equipped with inapplicable facilities for docked ships. Therefore, in order to effectively counteract the contingencies and obtain safety, it would be recommended to install adequate facilities.

Estimation of Canopy Fuel Characteristics for Pinus densiflora Stands Using Diameter Distribution Models: Forest Managed Stands and Unmanaged Stands (직경분포모형을 이용한 소나무림의 수관연료특성 예측: 산림시업지 임분과 비시업지 임분에서)

  • Lee, Sun Joo;Kim, Sung Yong;Lee, Byung Doo;Lee, Young Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.4
    • /
    • pp.412-421
    • /
    • 2018
  • The objective of this study was to analyze the effects of forest management activities on canopy fuel characteristics for Pinus densiflora stands in South Korea. We used 1,085 managed stands data and 349 unmanaged stands data of the National Forest Inventory for this study, and it was estimated by using the Weibull function for the growth of stand and canopy fuel characteristics. Comparing the canopy fuel characteristics for the managed stands and unmanaged stands shows that the average canopy fuel load is about 14% higher than that of managed stands, and the canopy bulk density is also approximately 16% higher. The results of comparing growth projections for 40 years, 50 years and 60 years with the Weibull function are as follows: Over time, managed stands was predicted the maximum number of medium and large class diameter, while unmanaged stands was predicted maximum number of small and medium class diameter. From a fire fuel perspective, unmanaged stands are predicted to be of the type small class diameter and high density, which is a good condition for crown fire. In addition, Canopy fuel load, Canopy bulk density is relatively higher than managed stands, indicating that the possibility of high crown fire hazard.

The Ways of Improving Technical Standards to Increase Effectiveness of Wetting Agent (침윤소화약제의 효과성 증대를 위한 기술기준 개선방안)

  • Jang, Kwan Su;Kim, Jung Min;Cho, Young Jae
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.581-588
    • /
    • 2022
  • Purpose: This study is about offering ways of improving existing technical standards in order to propose how to deal with coal deep-seated fire and to increase effectiveness of wetting agent. Method: This study conducts infiltration experiment using eight tons of coal, three types of wetting agents and fire water. And this study analyzes domestic and international technical standards, overseas experimental cases. Result: It is found that two findings are identified; one is fire water cannot infiltrate into the coal due to high level of surface tension, and the other is three types of wetting agent can infiltrate into the coal to the depth of 5~25cm. Also, domestic wetting agent technical standards include measuring surface tension only and testing wood on extinguishing capacity test. On the other hand, this study found that deep-seated fire experiment using cotton, B-class fire test using heptane are used from abroad. Besides it is analyze that capillary rise test, sink test, contact angle measurement are conducted to increase effectiveness of wetting agent at the U.S. Bureau of Mines. Conclusion: Based on standards and cases of U.S. NFPA and Bureau of Mines, this study suggests that domestic technical standards should include adding a new test standard which measures infiltration directly.

Analyzing Disaster Response Terminologies by Text Mining and Social Network Analysis (텍스트 마이닝과 소셜 네트워크 분석을 이용한 재난대응 용어분석)

  • Kang, Seong Kyung;Yu, Hwan;Lee, Young Jai
    • Information Systems Review
    • /
    • v.18 no.1
    • /
    • pp.141-155
    • /
    • 2016
  • This study identified terminologies related to the proximity and frequency of disaster by social network analysis (SNA) and text mining, and then expressed the outcome into a mind map. The termdocument matrix of text mining was utilized for the terminology proximity analysis, and the SNA closeness centrality was calculated to organically express the relationship of the terminologies through a mind map. By analyzing terminology proximity and selecting disaster response-related terminologies, this study identified the closest field among all the disaster response fields to disaster response and the core terms in each disaster response field. This disaster response terminology analysis could be utilized in future core term-based terminology standardization, disaster-related knowledge accumulation and research, and application of various response scenario compositions, among others.

A Priority-Based Bandwidth Management Method in Public Safety Networks (재난 안전 통신망에서 우선순위를 고려한 대역폭 관리 방법)

  • Lee, Sang-Hoon;Kim, Hyun-Woo;Yoon, Hyun-Goo;Choi, Yong-Hoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.2
    • /
    • pp.102-110
    • /
    • 2016
  • After Sewol ferry disaster occurred in April 2014, Korean government began investing to deploy LTE-based public safety network until the year of 2017. In order to reduce the operating and capital costs, resource sharing scheme among public safety network and commercial LTE networks is considered as one of the viable approaches. This thesis proposes a method of allocating bandwidth of public safety network based on various priorities required for disaster scenarios and stages in a resource sharing environment. In order to obtain the highest efficiency, we formulate the bandwidth allocation problem as a Fractional Knapsack Problem. Greedy algorithm was applied to solve the problem. For performance evaluation, we created several disaster scenarios and set suitable parameters for each scenario based on a disaster manual. The proposed method is compared with two typical methods, which are Class-based bandwidth allocation and Uniform bandwidth allocation. The results showed that the better performance in terms of the sum of the values and the amount of lost bytes.

A Study on the Disaster Prevention of the Royal Tomb Eureung in the Mountain Cheonjang - Estimation on Forest Fire Risk Considering Forest Type and Topography - (천장산 의릉의 방재대책에 관한 연구 - 임상과 지형인자를 고려한 산불위험성 평가 -)

  • Won, Myoung-Soo;Lee, Woo-Kyun;Choi, Jong-Hee
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.1
    • /
    • pp.59-65
    • /
    • 2010
  • The purpose of this study is to analyze the risk of the forest fire, considering the topography and the forest, for establishing disaster prevention measures of cultural heritage, Uireung, over in Cheonjang-mountain. To do that, we estimate the occurrence and spread of the forest fire over in Cheonjang-mountain through a forest fire probability model(logistic regression), using the space characteristic data($100m{\times}100m$). The factor, occurrence of the forest fire, are diameter class, southeast, southwest, south, coniferous, deciduous, and mixed forest. We assume the probability of the fire forest in each point as follow : [1+exp{-(-4.8081-(0.02453*diameter class)+(0.6608*southeast)+(0.507*southwest)+(0.7943*south)+(0.29498*coniferous forest)+(0.28897*deciduous forest)+(0.17788*mixed forest))}]$^{-1}$. To divide dangerous zone of the big forest fire, we make the basic materials for disaster prevention measures, through the map of coniferous forests, deciduous forests, and mixed forest. The damage of cultural heritage caused by a forest fire will be reduced through the effective preventive measures, by forecast a forest fire to using this study.