• Title/Summary/Keyword: Disaster Area

Search Result 1,510, Processing Time 0.029 seconds

Development of Radar Polygon Method : Areal Rainfall Estimation Technique Based on the Probability of Similar Rainfall Occurrence (Radar Polygon 기법의 개발 : 유사강우발생 확률에 근거한 면적강우량 산정기법)

  • Cho, Woonki;Lee, Dongryul;Lee, Jaehyeon;Kim, Dongkyun
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.11
    • /
    • pp.937-944
    • /
    • 2015
  • This study proposed a novel technique, namely the Radar Polygon Method (RPM), for areal rainfall estimation based on radar precipitation data. The RPM algorithm has the following steps: 1. Determine a map of the similar rainfall occurrence of which each grid cell contains the binary information on whether the grid cell rainfall is similar to that of the observation gage; 2. Determine the similar rainfall probability map for each gage of which each grid cell contains the probability of having the rainfall similar to that of the observation gage; 3. Determine the governing territory of each gage by comparing the probability maps of the gages. RPM method was applied to the Anseong stream basin. Radar Polygons and Thiessen Polygons of the study area were similar to each other with the difference between the two being greater for the rain gage highly influenced by the orography. However, the weight factor between the two were similar with each other. The significance of this study is to pioneer a new application field of radar rainfall data that has been limited due to short observation period and low accuracy.

A Study on Estimation of Levee Safety Map for Determining the Priority of River Maintenance (하천 유지관리 우선순위 결정을 위한 제방안전도맵 산정방법 연구)

  • Yoon, Kwang Seok;Kim, Sooyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.17-25
    • /
    • 2017
  • Owing to recent climate change, the scale of rainfall tends to increase gradually and the risk of flooding has increased. Therefore, the importance of improving the levee management and disaster response is increasing. Levee management in Korea is carried out at the level of damage recovery after the occurrence of damage. Therefore, it is necessary to develop a technology for predicting and managing the levee safety with proactive river management. In this study, a method to estimate the safety against erosion and overflow was suggested. A map of levee safety that can be used as basic data is presented by displaying the levee safety on the map. The levee erosion safety was calculated as the ratio of the internal and external force for each shore type. The levee overflow safety was calculated as the ratio of the maximum conveyance and design flood. The maximum conveyance was a discharge when the level of the river was equal to the level of the levee crown. The levee safety was classified into 5 grades: very safe, safe, normal, dangerous, and very dangerous. As a research area from downstream of Nam River Dam to Nakdong River Junction, the levee safety against erosion and overflow was estimated for all levees and all cross-sections of the river. The levee safety was displayed on a map using GIS. Through the levee safety map as a result of this study, the levee safety can be observed intuitively. Using the levee safety map, a maintenance plan for a river can be easy to build. This levee safety map can be used to help determine the priority of investment for efficient budget used.

A Basic Study on the Estimating the Value of Sand Beach using amenities (어메니티요소를 활용한 백사장 가치평가의 기초적 연구)

  • Shin, Bum-Shick;Kim, Kyu-Han
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.6
    • /
    • pp.373-380
    • /
    • 2012
  • The sandy beach along the east coast of Korea offers beautiful scenery with high-quality sand for leisure, and is also famous for the white-sand and pine-tree which is an important scenic resource. Furthermore, the sandy beach helps to maintain natural environment of the costal area and functionates as a disaster prevention system against high waves. There are two major value evaluation methods, Travel Cost Method and Contingent Valuation Method, to assess the value of coastal sandy beach. Contingent Valuation Method is considered to be more appropriate for simultaneous evaluation on the usefulness and the uselessness of the beach. But in order to apply Contingent Valuation Method to coastal sandy beach evaluation, close examination and investigation on the potential bias, such as on questionnaires, surveys and replies, are required. In this study, the characteristic of primary amenity of sandy beach users is investigated, in prior to evaluating the usefulness and the uselessness of the beach measured by contingent valuation method. The characteristic of amenity on major sandy beaches on the east coast of Korea is studied and compared by diverse value evaluation methods.

An Analysis of Flushing Effects for Instantaneous Contaminants Input into River (하천에 순간적으로 유입된 오염물질의 플러싱 효과 분석)

  • Jung, Jae-Wook;Kim, Soo-Youl;Kim, Jin-Young;Yoon, Sei-Eui
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.3 s.14
    • /
    • pp.43-50
    • /
    • 2004
  • This study had been performed to analyze flushing effects for instantaneous contaminants input with changing dam discharge in River. RMA-2 and RMA-4 models were applied to the downstream part of the Han River(from Jamsil submerged weir to Singok submerged one) The longitudinal dispersion coefficient of $50m^2/s$ was used. The four cases of dam discharges were selected as $500m^3/s,\;1000m^3/s,\;1500m^3/s$ and $2000m^3/s$, respectively, for 1 hour. The drought flow was fixed $200m^3/s$ in the Han River. The arrival time and the concentration of contaminant, the area of dispersion were estimated with RMA-4 model in the downstream part of the Han River. The arrival time which the concentration of contaminants become under 1ppm was analyzed with the stagnant and the instantaneous inflow contaminant at the section of Sungsan Bridge. The more increasing a dam discharge, the more short a dilution time of contaminant. The relation between the dam discharge and dilution time shows linearity. The instantaneous contaminant input was sensitively affected by the dam discharge than the stagnant contaminant one in the river. If it is tried to flush with a temporally increased dam discharge, it should be understood the range of overflowed contaminant dispersion from main channel to tributary channel.

Technological Development Trends for Underground Safety in Urban Construction (도심지 공사시 지하안전 확보를 위한 기술개발 동향)

  • Baek, Yong;Kim, Woo Seok
    • Tunnel and Underground Space
    • /
    • v.27 no.6
    • /
    • pp.343-350
    • /
    • 2017
  • Amid increasingly saturated ground space, development of underground space has been booming throughout the world and excavation has been underway near the structure above or under the ground level. But the ground subsidence caused by improper or poor construction technologies, underground water leakage, sudden changes of stratum and the problem with earth retaining system component has been emerged as hot social issue. To deal with such problems nationwide, establishment of preventive and proactive disaster management and rapid restoration system has been pushed now. In this study, collection of the data on technology development trend to secure the underground safety was made, taking into account of internal change elements (changing groundwater level, damage to underground utilities, etc) and external change elements (vehicle load, earthquake and ground excavation, etc) during excavation. Amid the growing need of ground behavior analysis, ground subsidence evaluation technology, safe excavation to prevent ground subsidence and reinforcement technology, improvement of rapid restoration technology in preparation for ground subsidence and development of independent capability, this study is intended to introduce the technology development in a bid to prevent the ground subsidence during excavation. It's categorized into prediction/evaluation technology, complex detect technology, waterproof reinforcement technology, rapid restoration technology and excavation technology which, in part, has been in process now.

Treatment of Combat-related Gunshot and Explosive Injuries to the Extremities (전투 상황에서 발생한 사지 총상 및 폭발창의 치료)

  • Lee, Jung Eun;Lee, Young Ho;Baek, Goo Hyun;Lee, Kyung-Hag;Cho, Young Jae;Kim, Yeong Cheol;Suh, Gil Joon
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.111-124
    • /
    • 2013
  • Purpose: We should prepare proper medical service for disaster control as South Korea is not free from terrorism and war, as we experienced through the two naval battles of the Yeonpyeong, one in 1999 and the other in 2002, the sinking of Cheonan in 2010, and the attack against the border island of Yeonpyeong in 2010. Moreover, North Korea's increasingly bellicose rhetoric and mounting military threats against the world demand instant action to address the issue. The aim of this article is to describe our experience with three patients with combat-related gunshot and explosive injuries to their extremities and to establish useful methods for the management of patients with combat-related injuries. Methods: Three personnel who had been injured by gunshot or explosion during either the second naval battle of the Yeonpyeong in 2002 or the attack against the border island of Yeonpyeong in 2010 were included in our retrospective analysis. There were one case of gunshot injury and two cases of explosive injuries to the extremities, and the injured regions were the left hand, the right foot, and the right humerus. In one case, the patient had accompanying abdominal injuries, and his vital signs were unstable. He recovered after early initial management and appropriate emergency surgery. Results: All patients underwent emergent surgical debridement and temporary fixation surgery in the same military hospital immediately after their evacuations from the combat area. After that, continuous administration of antibiotics and wound care were performed, and definite reconstructions were carried out in a delayed manner. In the two cases in which flap operations for soft tissue coverage were required, one operation was performed 5 weeks after the injury, and the other operation was performed 7 weeks after the injury. Definite procedures for osteosynthesis were performed at 3 months in all cases. Complete union and adequate functional recovery were achieved in all cases. Conclusion: The patient should be stabilized and any life-threatening injuries must first be evaluated and treated with damage control surgery. Staged treatment and strict adherence to traditional principles for open fractures are recommended for combat-related gunshot and explosive injuries to the extremities.

A Comparative Study on the Effect of Fire Retardancy of the Plywood Treated by Ammonium Sulphate and Monoammonium Phosphate (황산암모늄과 제 1 암모늄처리(處理) 합판(合板)의 내화효과에 관(關)한 비교연구(比較硏究))

  • Lee, Phil-Woo;Kim, Cheol-San
    • Journal of the Korean Wood Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.23-30
    • /
    • 1983
  • This experiment was carried out for diminishing the material loss and the damage of human life due to the fire disaster by treating plywood with fire retardant chemical solution. At this study, we observed and measured chemical retention, burning point, maximum flame length, flame exausted time, carbonized area, and weight loss of plywood treated by each solution of ammonium sulphate [$(NH_4)_2SO_4$] and monoammonium phosphate [$NH_4H_2PO_4$]. Obtained results at the study may be summarized as follows: 1. In case of monoammonium phosphate-treated plywood, every tested item of fire retardancy was shown more excellent at the 25% chemical concentration and shown also at 9 hours treatment except maximum flame length compared with ammonium sulphate-treated plywood. 2. However in case of ammonium sulphate-treated plywood, 6 hours treatment of fire retardancy was better than 9 hours treating time. 3. Monoammonium phosphate was generally better than ammonium sulphate in every tested item.

  • PDF

A Study on the Application Scheme of Fire Identification Considering the Heat Release Rate Characteristics of Inflammable Material (가연물의 발열량 특성을 고려한 화재감식 적용방안에 관한 연구)

  • Kang, Jung-Ki;Oh, Jin-Hee;You, Woo-Jun;Ryou, Hong-Sun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.52-57
    • /
    • 2014
  • The present study suggests the fundamental method for the prediction time of the fire origin by analyzing the combustion phenomenon of inflammable material in the building structure. The heat release rate (HRR) with time variant is evaluated for the interphone as a inflammable material, which is opted from the fire incidents in the stairwell. the fire dynamics simulator (FDS ver. 6.1) is applied in order to analyze the difference of the smoke inflow time to the downstair from the fire event area with various fire pattern. The results show that the maximum inflow time difference for the case of the interphone made from ABS materials is about 4.93 times with the input conditions of heat flux values and the environment in the FDS for the fixed stairwell which composed of total volume $291.3m^3$, floorage $23.3m^2$ and the height of each floor 2.5 m. This research can be practical information for the application method of simulation scheme with experimental data to the fire Identification.

Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

Measurements of the Heat Release Rate and Fire Growth Rate of Combustibles for the Performance-Based Design - Focusing on the Combustibles in Residential and Office Spaces (성능위주설계를 위한 가연물의 열발생률 및 화재성장률 측정 -주거 및 사무공간 가연물을 중심으로)

  • Nam, Dong-Gun;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.29-36
    • /
    • 2017
  • The design fire based on the heat release rate (HRR) of combustibles can significantly affect the assessment of fire safety in the performance-based design (PBD). In the present PBD, however, limited information in the foreign literature has been used without further verification due to the lack of fire information in domestic combustibles. The objective of this study is to provide information on the HRR and fire growth rate for various combustibles in residential and office spaces. To end this, the fire experiments were carried out with single and multiple combustibles. The peak HRR of combustibles used in the present study had a range of 36 kW~1,092 kW. The fire growth rates were also $0.003kW/s^2{\sim}0.0287kW/s^2$ and $0.003kW/s^2{\sim}0.0838kW/s^2$ for the residential and office spaces, respectively. In particular, a sofa had the highest fire risk in terms of the peak HRR and fire growth rate. Finally, a methodology for calculating the peak HRR in a space was proposed through correlation analysis between the peak HRR and exposed surface of various combustibles.