• Title/Summary/Keyword: Direction of rotation

Search Result 699, Processing Time 0.026 seconds

Comparison of Micro Mobility Patterns of Public Bicycles Before and After the Pandemic: A Case Study in Seoul (팬데믹 전후 공공자전거의 마이크로 모빌리티 패턴 비교: 서울시 사례 연구)

  • Jae-Hee Cho;Ga-Eun Baek;Il-Jung Seo
    • The Journal of Bigdata
    • /
    • v.7 no.2
    • /
    • pp.235-244
    • /
    • 2022
  • The rental history data of public bicycles in Seoul were analyzed to examine how pandemic phenomena such as COVID-19 caused changes in people's micro mobility. Data for 2019 and 2021 were compared and analyzed by dividing them before and after COVID-19. Data were collected from public data portal sites, and data marts were created for in-depth analysis. In order to compare the changes in the two periods, the riding direction type dimension and the rental station type dimension were added, and the derived variables (rotation rate per unit, riding speed) were newly created. There is no significant difference in the average rental time before and after COVID-19, but the average rental distance and average usage speed decreased. Even in the mobility of Ttareungi, you can see the slow rhythm of daily life. On weekdays, the usage rate was the highest during commuting hours even before COVID-19, but it increased rapidly after COVID-19. It can be interpreted that people who are concerned about infection prefer Ttareungi to village buses as a means of micro-mobility. The results of data mart-based visualization and analysis proposed in this study will be able to provide insight into public bicycle operation and policy development. In future studies, it is necessary to combine SNS data such as Twitter and Instagram with public bicycle rental history data. It is expected that the value of related research can be improved by examining the behavior of bike users in various places.

The Realization of Intensity-modulated Radiation Therapy Using the Liquid Shielding Material (액체 차폐물을 이용한 강도변조방사선치료의 구현)

  • 오영기;김진기;신교철;김기환;윤상모;김재철;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • We developed a new method that the radiation field shape and intensity could be controlled automatically with a insertion of the liquid shielding material box having a rotatable model imitated the 3-dimensional target volume within. The molded box filled with the mercury was mounted to the tray. A acrylic model imitated the 3-dimensional target volume was fixed into the center of the interior of the box. Although the gentry rotate, the acrylic model can be returned to the original direction of the target due to the action of the gravity. The film measurements at the gantry rotation angle 0$^{\circ}$, 45$^{\circ}$, and 90$^{\circ}$, respectively were shown that the radiation intensities were modulated properly and the field shapes were conformed to the target. We verified the dose distribution for our method with a cylindrical acrylic phantom inserted a film within. In the case of the 8-field irradiation, the 80% isodose line was enclosed the target shape properly. This results show the realization of a new intensity-modulated radiation therapy(IMRT).

  • PDF

Characteristic Analysis of Flexibility and Muscle Strength according to Exercise using Lumbar Strengthen Exercise Instrument (요추강화 운동기기의 훈련을 통한 유연성 및 근력 특성 분석)

  • Kang, S.R.;Kim, K.;Jeong, G.Y.;Moon, D.A.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.4 no.1
    • /
    • pp.53-61
    • /
    • 2010
  • In this paper, We investigated the characteristic analysis of flexibility and muscle strength for exercise to verify capacity in rehabilitation exercise of lumbar using lumbar strengthen exercise instrument. We have experiment in 20th years man and woman who are 20 subject with no medical history, we divided subjects into control group with no exercise and training group with lumbar strengthen exercise. We used Hi-Spine(Medicalscience.korea) also, provided exercise 40 minute a day, three days a week and progressed total four weeks. Moreover in our experiment, subjects exercised four postural position as lay down, sit, stand and stretch each ten minute. We measured trunk extension backward, trunk flexion forward, evaluation of based physical fitness and lumbar joint torque. The reults have shown that there more improved all for flexibility, based physical fitness and lumbar joint torque in training group than control group. We indicated that by rotating 3-D axis movement flatform of exercise instrument, muscle spindle in subject have been stimulated and these rotation direction and angle caused muscle tonus and contraction that makes muscle, flexibility and based physical fitness improve more. Our study can be used rehabilitation exercise program to aged people and patient with lumbar injury.

A STUDY ON THE EFFECT OF CHINCAP IN JUVENILE SKELETAL GLASS III MALOCCLUSION (유년기 III급 부정교합자에서 이모장치의 치료 효과에 관한 연구)

  • Nahm, Dong-Seok;Suhr, Chung-Hoon;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.517-531
    • /
    • 1998
  • The purpose of this study was to investigate the changes in the craniofacial skeleton subsequent to chincap therapy in the juvenile skeletal Class III malocclusion with more appropriate control samples. The experimental group consisted of 29 Korean children(14 males, 15 females) who had skeletal Class III malocclusion with prognathic mandible and were undergone chincap thorny from the beginning of treatment. The control group was composed of 21 Korean children(10 males, 11 females) who had no orthodontic treatment, but with similar skeletal discrepancies to experimental group. Lateral cephalometric radiographs at the age of 7, and 2 years later were analyized and compared with student's t-test(p<0.05). The results of this study were as follows; 1. The control group without chincap therapy had not shown any improvement of the skeletal discrepancies, but had grown to be much severe. This means that the untreated Class III patient with prognathic mandible would not be corrected by growth. For the experimental group with chincap therapy, the anterior-posterior skeletal discrepancies and mandibular prognathism were both improved. 2. Neither significant restraint nor acceleration of growth was found in the cranial base and maxilla by chincap treatment. 3. The inhibition of mandibular growth could not be accepted, but the changes of the direction of growth and morphological changes were found. 4. Vertical growth tendency was increased with chincap therapy. 5. When Putting together the results of the analyses , it seems to be the rotation and displacement of the mandible that the major treatment effects of chincap we. The changes of the direction of growth and the morphological changes also seems to contibute to the treatment effect partly. In summary, the chincap doesn't restrain the mandibular growth. But, it is considered as a useful treatment modality for correction of skeletal discrepancies and reduction of mandibular prognathism in growing Class III patients with madibular prognathism.

  • PDF

Evaluation of dose delivery accuracy due to variation in pitch and roll (세기변조방사선치료에서 Pitch와 Roll 변화에 따른 선량전달 정확성 평가)

  • Jeong, Chang Young;Bae, Sun Myung;Lee, Dong Hyung;Min, Soon Ki;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.239-245
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the pitch and roll rotational setup error with 6D robotic couch in Intensity Modulated Radiation Therapy (IMRT) for pelvic region in patients. Materials and Methods : Trilogy(Varian, USA) and 6D robotic couch(ProturaTM 1.4, CIVCO, USA) were used to measure and analyze the rotational setup error of 14 patients (157 setup cases) for pelvic region. The total 157 Images(CBCT 78, Radiography 79) were used to calculate the mean value and the incidence of pitch and roll rotational setup error with Microsoft Office Excel 2007. The measured data (3 mm, 3%) at the reference angle ($0^{\circ}$) without couch rotation of pitch and roll direction was compared to the others at different pitch and roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) to verify the accuracy of dose delivery by using 2D array ionization chamber (I'mRT Matrixx, IBA Dosimetry, Germany) and MultiCube Phantom(IBA Dosimetry, Germany). Result from the data, gamma index was evaluated. Results : The mean values of pitch and roll rotational setup error were $0.9^{\circ}{\pm}0.7$, $0.5^{\circ}{\pm}0.6$. The maximum values of them were $2.8^{\circ}$, $2.0^{\circ}$. All of the minimum values were zero. The mean values of gamma pass rate at four different pitch angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 97.75%, 96.65%, 94.38% and 90.91%. The mean values of gamma pass rate at four different roll angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$, $2.5^{\circ}$) were 93.68%, 93.05%, 87.77% and 84.96%. when the same angles ($1^{\circ}$, $1.5^{\circ}$, $2^{\circ}$) of pitch and roll were applied simultaneously, The mean values of each angle were 94.90%, 92.37% and 87.88%, respectively. Conclusion : As a result of this study, it was able to recognize that the accuracy of dose delivered is lowered gradually as pitch and roll increases. In order to increase the accuracy of delivered dose, therefore, it is recommended to perform IGRT or correct patient's position in the pitch and roll direction, to improve the quality of treatment.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Analyzing animation techniques used in webtoons and their potential issues (웹툰 연출의 애니메이션 기법활용과 문제점 분석)

  • Kim, Yu-mi
    • Cartoon and Animation Studies
    • /
    • s.46
    • /
    • pp.85-106
    • /
    • 2017
  • With the media's shift into the digital era in the 2000s, comic book publishers attempted a transition into the new medium by establishing a distribution structure using internet networks. But that effort shied from escaping the parallel-page reading structure of traditional comics. On the other hand, webtoons are showing divers changes by redesigning the structure of traditional sequential art media; they tend to separate and allot spaces according to the vertical scroll reading method of the internet browser and include animations, sound effects and background music. This trend is also in accordance with the preferences of modern readers. Modern society has complicated social structures with the development of various media; the public is therefore exposed to different stimuli and shows characteristics of differentiated perceptions. In other words, webtoons display more relevant and entertaining characteristics by inserting sounds and using moving texts and characters in specific frames, while traditional comics require an appreciation of withdrawal and immersion like other published media. Motions in webtoons are partially applied for dramatic tension or to create an effective expression of action. For example, hand-drawn animation is adopted to express motions by dividing motion images into many layers. Sounds are also utilized, such as background music with episode-related lyrics, melodies, ambient sounds and motion-related sound effects. In addition, webtoons provide readers with new amusement by giving tactile stimuli via the vibration of a smart phone. As stated above, the vertical direction, time-based nature of animation motions and tactile stimuli used in webtoons are differentiated from published comics. However, webtoons' utilization of innovative techniques hasn't yet reached its full potential. In addition to the fact that the software used for webtoon effects is operationally complex, this is a transitional phenomenon since there is still a lack of technical understanding of animation and sound application amongst the general public. For example, a sound might be programmed to play when a specific frame scrolls into view on the monitor, but the frame may be scrolled faster or slower than the author intended; in this case, sound can end before or after a reader sees the whole image. The motion of each frame is also programmed to start in a similar fashion. Therefore, a reader's scroll speed is related to the motion's speed. For this reason, motions might miss the intended timing and be unnatural because they are played out of context. Also, finished sound effects can disturb the concentration of readers. These problems come from a shortage of continuity; to solve these, naturally activated consecutive sounds or animations, like the simple rotation of joints when a character moves, is required.

An Understanding the Opening Style of the West Philippine Basin Through Multibeam High-Resolution Bathymetry (고해상도 다중빔음향측심 지형자료 분석을 통한 서필리핀분지의 진화 연구)

  • Hanjin Choe;Hyeonuk Shin
    • Journal of the Korean earth science society
    • /
    • v.44 no.6
    • /
    • pp.643-654
    • /
    • 2023
  • The West Philippine Basin, an oceanic basin half the size of the Philippine Sea Plate, lies in the western part of the plate and south of the Korean Peninsula on the Eurasian Plate. It subducts beneath the Eurasian Plate and the Philippine Islands bordering the Ryukyu Trench and the Philippine Trench with 25-50% of this basin already consumed. However, the history of the opening of the basin's southern region has been a topic of debate. The non-transform discontinuity formed during the seafloor spreading is similar to the transform fault boundaries normally perpendicular to mid-ocean ridge axes; however, it was created irregularly due to ridge propagations caused by variations of mantle convection attributable to magma supply changes. By analyzing high-resolution multi-beam echo-sounding data, we confirmed that the non-transform discontinuity due to the propagating rift evolved in the entire basin and that the abyssal hill strike direction changed from E-W to NNW-SSE from the fossil spreading center. In the early stage of basin extension, the Amami-Sankaku Basin was rotated 90 degrees clockwise from its current orientation, and it bordered the Palau Basin along the Mindanao Fracture Zone. The Amami-Sankaku Basin separated from the Palau Basin while the spreading of the West Philippine Basin began with a counter-clockwise rotation. This indicates that the non-transform discontinuities formed by a sudden change in magma supply due to the drift of the Philippine Sea Plate and simultaneously with the rapid changes in the spreading direction from ENE-WSW to N-S. The Palau Basin was considered to be the sub-south of the West Philippine Basin, but recent studies have shown that it extends into an independent system. Evidence from sediment layers and crustal thickness hints at the possibility of its existence before the West Philippine Basin opened, although its evolution continues to be debated. We performed a combined analysis using high-resolution multi-beam bathymetry and satellite gravity data to uncover new insights into the evolution of the West Philippine Basin. This information illuminates the complex plate interactions and provides a crucial contribution toward understanding the opening history of the basin and the Philippine Sea Plate.

A study on the perimandibular tissues before and after orthodontic treatment with orthognathic surgery in mandandibular prognathic patients (하악골 전돌자의 악교정 수술을 동반한 교정치료 전후 하악골 주위조직의 변화에 관한 연구)

  • Yang, Byung-Ho;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.261-272
    • /
    • 2000
  • Severe skeletal anteroposterior and vertical discrepancy is difficult to obtain satisfactory result by only orthodontic treatment, and much anteroposterior movement and treatment stability require orthodontic treatment with orthognathic surgery. The treatment goal of mandibular prognathic patients is to promote the function of stomatognathic system including mastication and phonetics, to improve the esthetics of facial profile and to maintain stability. Positional changes of hyoid bone, pharynx and tongue were seen with mandibular movement after orthognathic surgery. This study was performed to observe the changes of perimandibular tissues of orthodontic patients with skeletal mandibular prognathism who treated with orthodontic treatment, and the changes of hyoid bone, pharyx and tongue by relapse or recurrance after before and after orthognathic surgery and retention. The 22 patients who had mandibular prognathism were selected. They treated with orthodontic treatment with sagittal split ramus osteotomy as orthognathic surgery. And lateral cephalometric radiographs were taken 3 times : pre-surgery (T1), immediate post-surgery (T2) and 2 years alter retention (T3). The results were as follows : 1. The hyoid bone returned back after clockwise rotation to maxilla and occlusal plane during retention (P<0.01). 2. The hyoid bone moved posterior-inferiorly by mandibular surgery and returned back anterior-superior after retention. (P<0.01) 3. The changes of pharyngeal depth showed a little decrease at upper area in post- surgery, but it was not a significant difference generally through before, after and retention. 4. In relating to tongue base, the angle of tongue base was decreased and the dorsal area of tongue base moved to inferior-posterior direction and to superior direction again after retention (P<0.01). 5. Related to the thickness of upper and lower lip, the thickness of upper lip decreased after surgery, and the soft tissues below lower lip increased after surgery and decreased after retention.

  • PDF

Physical Offset of UAVs Calibration Method for Multi-sensor Fusion (다중 센서 융합을 위한 무인항공기 물리 오프셋 검보정 방법)

  • Kim, Cheolwook;Lim, Pyeong-chae;Chi, Junhwa;Kim, Taejung;Rhee, Sooahm
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1125-1139
    • /
    • 2022
  • In an unmanned aerial vehicles (UAVs) system, a physical offset can be existed between the global positioning system/inertial measurement unit (GPS/IMU) sensor and the observation sensor such as a hyperspectral sensor, and a lidar sensor. As a result of the physical offset, a misalignment between each image can be occurred along with a flight direction. In particular, in a case of multi-sensor system, an observation sensor has to be replaced regularly to equip another observation sensor, and then, a high cost should be paid to acquire a calibration parameter. In this study, we establish a precise sensor model equation to apply for a multiple sensor in common and propose an independent physical offset estimation method. The proposed method consists of 3 steps. Firstly, we define an appropriate rotation matrix for our system, and an initial sensor model equation for direct-georeferencing. Next, an observation equation for the physical offset estimation is established by extracting a corresponding point between a ground control point and the observed data from a sensor. Finally, the physical offset is estimated based on the observed data, and the precise sensor model equation is established by applying the estimated parameters to the initial sensor model equation. 4 region's datasets(Jeon-ju, Incheon, Alaska, Norway) with a different latitude, longitude were compared to analyze the effects of the calibration parameter. We confirmed that a misalignment between images were adjusted after applying for the physical offset in the sensor model equation. An absolute position accuracy was analyzed in the Incheon dataset, compared to a ground control point. For the hyperspectral image, root mean square error (RMSE) for X, Y direction was calculated for 0.12 m, and for the point cloud, RMSE was calculated for 0.03 m. Furthermore, a relative position accuracy for a specific point between the adjusted point cloud and the hyperspectral images were also analyzed for 0.07 m, so we confirmed that a precise data mapping is available for an observation without a ground control point through the proposed estimation method, and we also confirmed a possibility of multi-sensor fusion. From this study, we expect that a flexible multi-sensor platform system can be operated through the independent parameter estimation method with an economic cost saving.