• Title/Summary/Keyword: Direction of rotation

Search Result 697, Processing Time 0.032 seconds

Effect of Neck Rotating Directions on the Muscle Activity of Upper and Lower Trapezius during Shoulder External Rotation

  • Shin, Yong Wook;Kim, Chi Hwan;Han, Jin Tae
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.2
    • /
    • pp.101-106
    • /
    • 2020
  • Purpose: This study examined the effects of the directions of neck rotation on the muscle activity of the upper trapezius and lower trapezius while rotating a shoulder externally. Methods: Twenty-five healthy males participated in this study. The subjects were asked to rotate their shoulder externally with 90° shoulder abduction and 90° elbow flexion in three different neck rotations (neutral, ipsilateral, and contralateral) in the prone position. The muscle activities of the upper and lower trapezius were measured using surface electromyography. One way repeated measures ANOVA was used to compare the muscle activity of the upper and lower trapezius depending on the different neck turning directions. Results: In the upper trapezius, turning the neck in the ipsilateral direction while turning a shoulder externally decreased the muscle activity significantly, but the muscle activity was increased significantly by turning the neck in the contralateral direction. On the other hand, in the lower trapezius, turning the neck in the ipsilateral direction increased the muscle activity significantly, but the muscle activity was decreased significantly by turning the neck in the contralateral direction decreased it significantly. Conclusion: When someone has an imbalance of shoulder function, turning the neck in the ipsilateral direction while turning the shoulder externally in the prone position is effective in decreasing the activity of the upper trapezius and increasing the activity of the lower trapezius. Therefore, these results could be used as basic evidence for researching patients with shoulder problems.

Prediction of Power Consumed By Forward and Reverse Rotation Rotavator using Field Load Analysis (필드 부하 분석을 이용한 정/역회전 로타베이터의 소요 동력 예측)

  • Kim, Jeong-Gil;Park, Jin-Sun;Cho, Seung-Je;Lee, Dong-Keun;Park, Young-Jun;Moon, Sang-Gon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.8
    • /
    • pp.67-73
    • /
    • 2021
  • In this study, we installed forward and reverse rotation rotavators on a tractor to measure the load in the field and analyze the power consumed. The rotavator is attached to the rear of the tractor and transmits the power applied from the power take off (PTO) of the tractor to the rotating shaft of the rotavator, and it plows or reverses the soil according to the rotational direction of the rotating shaft. Depending on the rotational direction of the rotavator, the power consumed in the tractor engine and the power transmitted to the tractor axle and rotavator also vary, thus, research of load and power is an essential factor in designing the system. As a field test results, 84.1-93.5% power was consumed by the forward rotation rotavator, and 37.8-57.5% power was consumed by the reverse rotation rotavator. In addition, depending on the rotation direction of the rotavator, the power consumed by the tractor was in the order of PTO and axle. Based on the research results, development of reliable rotavator systems would be possible in the future research.

The Nocturnal Changes of Plasma Melatonin Concentrations in Night Shift Workers : Comparison of the Clockwise and Counterclockwise Rotational Shift. (야간 근무시의 혈장 멜라토닌의 농도 변화 : 시계 방향과 반시계 방향의 교대근무 비교)

  • Min, Soon;Kim, Mi-Seung;Im, Wook-Bin
    • Journal of Korean Biological Nursing Science
    • /
    • v.2 no.2
    • /
    • pp.81-89
    • /
    • 2000
  • To determine the optimal rotational shift system, the effect of the direction of the rotational work shifting on the nocturnal rhythm of plasma melatonin were investigated in nursing students. Two groups of nine volunteers participated as experimental subjects, and two nursing students participated as a control group. The directions of the rotational work shift were as follows: CW(clockwise)-shift were rotated in the direction of day shift(3 days), evening shift(3 days), off duty(1 day) and night shift(5 days), and CCW(conuterclockwise)-shift were done in the reverse direction. Plasma melatonin concentrations was measured by radioimmunoassay. The results were as follows : The plasma melatonin levels were kept low at night and in the following morning in the CW night shift workers, whereas the level started to increase at 05 : 00 hr in two workers of four CCW shift workers. These result suggests that the shift rotation in the CW direction is more acceptable in terms of the adaptation of hormonal rhythms. These results indicate that the CCW rotation of shift work is somewhat better than CCW rotation for the adaptation to shift work on hormonal aspects in nurses.

  • PDF

User-friendly adjustable table fan with selective rotation angles (사용 편의성 향상을 위한 선풍기의 효율적 회전구간 선정)

  • Kim, Sang-Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.53-58
    • /
    • 2022
  • Since a general household fan has only one left/right turning stage, the rotation angle cannot be adjusted leading to cases whether the wind reaches to an unnecessary area or vice versa. In this paper, we propose a method to efficiently control the turning section to selectively send wind to a necessary space while reducing energy waste. The minimum rotation angle was obtained by experimentally measured the stationary wind direction angle of the fan, and the optimal number of turning stages was selected by appropriately dividing the space where the wind reaches. Through this, it was confirmed that if the fan has a minimum rotation angle of 45°, a turning section of 3 stages and its rotation angle is increased by twice the stationary wind direction angle at each stage, the wind is distributed efficiently. Therefore, it is considered that the selective turning stage control proposed in this paper can minimize energy waste without significant change of the fan structure.

A Study on the Development of CW(Continuous-Wave)Doppler System for measuring Bi-directional Blood Flow Information (혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구)

  • 강충신;김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.75-80
    • /
    • 1987
  • With the conventional CW Doppler velocity meter, bl-directional velocities cannot be separated. The new CW Doppler system uses quadrature detection and phase rotation to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, we can easily differentiate typical artery flow from vein flow, and measure both velocity characteristics qualitatively.

  • PDF

Rotation Angle Estimation of Multichannel Images (다채널 이미지의 회전각 추정)

  • Lee Bong-Kyu;Yang Yo-Han
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.6
    • /
    • pp.267-271
    • /
    • 2002
  • The Hotelling transform is based on statistical properties of an image. The principal uses of this transform are in data compression. The basic concept of the Hotelling transform is that the choice of basis vectors pointing the direction of maximum variance of the data. This property can be used for rotation normalization. Many objects of interest in pattern recognition applications can be easily standardized by performing a rotation normalization that aligns the coordinate axes with the axes of maximum variance of the pixels in the object. However, this transform can not be used to rotation normalization of color images directly. In this paper, we propose a new method for rotation normalization of color images based on the Hotelling transform. The Hotelling transform is performed to calculate basis vectors of each channel. Then the summation of vectors of all channels are processed. Rotation normalization is performed using the result of summation of vectors. Experimental results showed the proposed method can be used for rotation normalization of color images effectively.

Rotational Stability of AcrySof Toric Intraocular Lens Over Time: Influence of Capsulorhexis Contraction

  • Kim, Joong Hee;Cho, Kyong Jin
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.44-50
    • /
    • 2020
  • Background and Objectives To evaluate the rotational stability of AcrySof toric intraocular lenses (IOL) by considering lapse of postoperative time and influence of capsulorhexis contraction. Materials and Methods A prospective, masked, single center study was conducted on 19 patients who had undergone microcoaxial cataract surgery and AcrySof toric IOL implantation. Slit-lamp retroillumination photographs of anterior segments were obtained from all patients after 1 week, 1 month and 3 months post-surgery. The degree of alteration of the postoperative IOL axis alignment and the amount of anterior capsular shrinkage were analyzed using Adobe Photoshop software. Results The mean degree of toric IOL axis misalignment was 2.18 (±20.2) degrees at 3 months follow-up. Quadrant analysis of the capsulorhexis aperture area at 1 week and 1 month post-operative, showed counterclockwise IOL rotation when the capsule contraction was dominant in the haptic part as well as clockwise rotation when dominant in the non-haptic part (p = 0.015). Conclusion The direction and degree of AcrySof toric IOL rotation differed throughout the follow-up period. Since most misalignments were found on the first post-operative day, physicians should try to minimize peri-operative risk factors that influence IOL rotation. There was also a correlation between the part of anterior capsule contraction and the direction of IOL rotation.

Force-Reflecting Teleoperation for Grinding Work

  • Choo, Jung-Hoon;Lee, Jae-Yong;Lee, Jae-Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.824-828
    • /
    • 2003
  • This paper explains problems of force-reflecting teleoperation grinding work and proposes some methods to solve those. For stable contact between robot tool(grindstone) and contact surface the mechanical impedance force control is used. The sliding phenomenon of grindstone has been appeared at the contact surface during the grinding work. The sliding problems caused by friction and rotation of grindstone are eliminated by using tangential direction sliding compensation control. The rotation force of grindstone makes the tool move to tangential direction along the surface suddenly even though an operator pushes the tool only in normal direction to the surface. Normal direction force control is applied for grinder not to roll and fracture on the grinding surface. Vibration problem of grindstone is decreased by second order low-pass filter. Therefore we can precise grinding work at the grinding surface and feel the reality

  • PDF

Correlations between Axial Rotation of Toric Soft Contact Lenses and Corneal Eccentricity according to the Wearing Time and Gaze Directions (착용시간 및 응시방향에 따른 토릭소프트콘택트렌즈의 축 회전과 각막이심률과의 상관관계)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the effect of corneal eccentricity on the axial rotation when wearing toric soft contact lenses were worn for certain time and changing the gaze directions. Methods: Toric soft contact lenses with double thin zone design applied on 85 of with-the-rule astigmatic eyes. Then, rotational direction and amount of contact lenses were measured after 15 minutes and 6 hours of lens wear. The difference was further compared and analyzed according to corneal eccentricity. Results: The rotation of toric lens showed a tendency to rotate to temporal direction in all gaze directions except temporal-upper direction in all groups of corneal eccentricity. The amount of lens rotation in the frontal gaze direction exhibited a negative correlation since the amount was decreased with increasing corneal eccentricity after both 15 minutes and 6 hours of lens wearing. In many cases, the cornea with small eccentricity also showed the lens rotation larger than $10^{\circ}$. The difference in rotational amount after 15 minutes of toric lens wear was small according to the corneal eccentricity however, the change of rotational amount of contact lens according to corneal eccentricity was shown after 6 hours of lens wear. Conclusions: The present study revealed that the amount of axial rotation was largely varied according to the wearer's corneal eccentricity when wearing toric lens and the rotational amount after certain time of lens was also affected by corneal eccentricity. Thus, it is suggested that the selection of toric soft contact lenses based on corneal eccentricity is necessary.

The Effects of Scalenus Medius Muscle Relaxed Posture on Head-Neck Rotation of General Adults (중사각근 이완자세가 일반성인의 경부 회전에 미치는 영향)

  • Lee, Jung-Hoon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose : This research intended to find out the effects of scalenus medius muscle relaxed posture on the increase of head-neck rotation for general adults. Methods : This research was conducted on 30 subjects whose both sides head neck rotation angles are not the same and that agreed to participate in the experiment. In a posture of sitting erectly on a mat, both sides head neck rotation angles were measured with C-ROM equipment, and while supporting arm in direction opposite the side where head neck rotation limited and leaning over the body at 45 degree and neck at vertical condition against ground, head-neck rotation angles were measured each with C-ROM equipment. Results : The Head-Neck rotation angle on the side of limited head-neck rotation demonstrated more increase in scalenus medius relaxed posture than in erect sitting posture, showing significant difference statistically(p<0.05). The head-neck rotation angle on the side of non-limited Head-Neck rotation demonstrated more decrease in scalenus medius relaxed posture than in erect sitting posture, not showing any significant difference statistically (p>0.05). Conclusions : This posture may be used for preventing limit of head-neck rotation caused of scalenus medius muscle tension and increasing head-neck rotation.