• Title/Summary/Keyword: Direction Simulation Monte Carlo

Search Result 67, Processing Time 0.02 seconds

Theoretical Prediction of Dynamic Elastic Moduli and Attenuation Properties of Fiber-Reinforced Composite Materials (섬유강화 복합재료의 동탄성계수 및 감쇠특성의 이론적 예측)

  • 김진연;이정권
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2328-2339
    • /
    • 1992
  • The propagation of coherent time-harmonic elastic L-and SV-waves is studied in a medium with random distribution of cylindrical inclusions. The purpose of the research is to characterize the dynamic elastic moduli and the attenuation properties of fiber-reinforced composite materials. The cylindes representing the fibers are assumed to be distributed in parallel with each other and the direction of incident waves are normal to the cylinder axes. A multiple scattering formula using the single scattering coefficients in conjunction with the Lax's quasicrystalline approximation is derived from which the dispersion relation for such medium is obtained. In order to formulate the multiple scattering interaction between cylinders, the pair correlation functions are generated by the Monte Carlo simulation technique. From the numerically evaluated complex wavenumbers, the propagation speed of the average wave, the coherent attenuation and the effective elastic moduli are presented as functions of frequency and fiber volume fraction.

RBDO of Coil Spring Considering Transversal Direction Mode Tracking (횡방향 모드추적을 고려한 코일스프링의 신뢰성기반 최적설계)

  • Lee, Jin Min;Jang, Junyong;Lee, Tae Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.6
    • /
    • pp.821-826
    • /
    • 2013
  • When the values of design variables change, mode switching can often occur. If the mode of interest is not tracked, the frequencies and modes for design optimization may be miscalculated owing to modes that differ from the intended ones. Thus, mode tracking must be employed to identify the frequencies and modes of interest whenever the values of design variables change during optimization. Furthermore, reliability-based design optimization (RBDO) must be performed for design problems with design variables containing uncertainty. In this research, we perform RBDO considering the mode tracking of a compressive coil spring, i.e., a component of the joint spring that supports a compressor, with design variables containing uncertainty by using only kriging metamodels based on multiple responses approach (MRA) without existing mode tracking methods. The reliability analyses for RBDO are employed using kriging metamodel-based Monte Carlo simulation.

Analysis of the Interaction Between Hypersonic Free Stream and Side Jet Flow Using a DSMC Method (직접모사법을 이용한 극음속 대기 유동과 측면 제트의 상호 작용 해석)

  • Kim, Min-Gyu;Kwon, Oh-Joon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.1-9
    • /
    • 2005
  • The interaction between hypersonic free stream and side jet flow at high altitudes is investigated by using the direct simulation Monte Carlo (DSMC) method. In order to alleviate the difficulty associated with the large density difference between the free stream and the side jet flow and to simulate the two flows simultaneously, a weighting factor technique is applied. For validation, the corner flow over a pair of plates perpendicularly attached is calculated with and without a side jet, and the results are compared with experiment. For a more realistic configuration, the flow past a blunted cone cylinder shape is solved. The leeward or windward jet is injected into the free stream and the effect on the aerodynamic force and moment is observed at various flow angles. The lambda shock effect and the wake structure are studied in terms of the surface pressure differential. A higher interaction between the free stream and the side jet flow is observed when the side jet is injected in the windward direction.

Wind-excited stochastic vibration of long-span bridge considering wind field parameters during typhoon landfall

  • Ge, Yaojun;Zhao, Lin
    • Wind and Structures
    • /
    • v.19 no.4
    • /
    • pp.421-441
    • /
    • 2014
  • With the assistance of typhoon field data at aerial elevation level observed by meteorological satellites and wind velocity and direction records nearby the ground gathered in Guangzhou Weather Station between 1985 and 2001, some key wind field parameters under typhoon climate in Guangzhou region were calibrated based on Monte-Carlo stochastic algorithm and Meng's typhoon numerical model. By using Peak Over Threshold method (POT) and Generalized Pareto Distribution (GPD), Wind field characteristics during typhoons for various return periods in several typical engineering fields were predicted, showing that some distribution rules in relation to gradient height of atmosphere boundary layer, power-law component of wind profile, gust factor and extreme wind velocity at 1-3s time interval are obviously different from corresponding items in Chinese wind load Codes. In order to evaluate the influence of typhoon field parameters on long-span flexible bridges, 1:100 reduced-scale wind field of type B terrain was reillustrated under typhoon and normal conditions utilizing passive turbulence generators in TJ-3 wind tunnel, and wind-induced performance tests of aero-elastic model of long-span Guangzhou Xinguang arch bridge were carried out as well. Furthermore, aerodynamic admittance function about lattice cross section in mid-span arch lib under the condition of higher turbulence intensity of typhoon field was identified via using high-frequency force-measured balance. Based on identified aerodynamic admittance expressions, Wind-induced stochastic vibration of Xinguang arch bridge under typhoon and normal climates was calculated and compared, considering structural geometrical non-linearity, stochastic wind attack angle effects, etc. Thus, the aerodynamic response characteristics under typhoon and normal conditions can be illustrated and checked, which are of satisfactory response results for different oncoming wind velocities with resemblance to those wind tunnel testing data under the two types of climate modes.

Reliability Evaluation of a Composite Pressure Vessel (복합재 압력 용기의 신뢰도 예측)

  • Hwang Tae-Kyung;Park Jae-Beom;Kim Hyoung-Geun;Doh Young-Dae;Moon Soon-Il
    • Composites Research
    • /
    • v.19 no.3
    • /
    • pp.7-14
    • /
    • 2006
  • In this paper, an integrated probabilistic strength analysis was conducted to predict the reliability of a composite pressure vessel under inner pressure loading condition. As a probabilistic strength analysis, the probabilistic progressive failure model consisting of progressive failure model and Monte Carlo simulation was incorporated with a commercial FEA code, ABAQUS Standard, to perform the probabilistic failure analysis of composite structure which has a complex shape and boundary conditions. As design random variables, the laminar strengths of each direction were considered. Finally, from probabilistic strength analysis, the scattering of burst pressure could be explained and the reliability of composite pressure vessel could be obtained for each component. In case of composite structures in mass production, the effects of uncertainties in material and manufacturing on the performance of composite structures would apparently become larger. So, the probabilistic strength analysis is essential for the structural design of composite structures in mass production.

Conceptual Source Design and Dosimetric Feasibility Study for Intravascular Treatment: A Proposal for Intensity Modulated Brachytherapy (혈관내 방사선치료를 위한 이론적 선원 설계 및 선량적 관점에서의 적합성 연구: 출력변조를 이용한 근접치료에 대한 제안)

  • Kim Siyong;Han Eunyoung;Palta Jatinder R.;Ha Sung W.
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.158-166
    • /
    • 2003
  • Purpose: To propose a conceptual design of a novel source for intensity modulated brachytherapy. Materials and Methods: The source design incorporates both radioactive and shielding materials (stainless steel or tungsten), to provide an asymmetric dose intensity in the azimuthal direction. The intensity modulated intravascular brachytherapy was performed by combining a series of dwell positions and times, distributed along the azimuthal coordinates. Two simple designs for the beta-emitting sources, with similar physical dimensions to a $^{90}Sr/Y$ Novoste Beat-Cath source, were considered in the dosimetric feasibility study. In the first design, the radioactive and materials each occupy half of the cylinder and in the second, the radioactive material occupies only a quater of the cylinder. The radial and azimuthal dose distributions around each source were calculated using the MCNP Monte Carlo code. Results: The preliminary hypothetical simulation and optimization results demonstrated the 87$\%$ difference between the maximum and minimum doses to the lumen wall, due to off-centering of the radiation source, could be reduced to less than 7$\%$ by optimizing the azimuthal dwell positions and times of the partially shielded intravascular brachytherapy sources. Conclusion: The novel brachytherapy source design, and conceptual source delivery system, proposed in this study show promising dosimetric characteristics for the realization of intensity modulated brachytherapy in intravascular treatment. Further development of this concept will center on building a delivery system that can precisely control the angular motion of a radiation source in a small-diameter catheter.

Evaluation of Attenuation Rate Error on Skin Dosimeter using Monte Carlo Simulation in Photon and Electron Beam Therapy (광자선 및 전자선 치료에서 피부선량계의 측정과 시뮬레이션을 이용한 감약률 오차 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Heo, Seung-Uk;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.841-848
    • /
    • 2020
  • In the field of radiation therapy using photon beams and electron beams, since each patient has a different sensitivity to radiation, skin side effects may occur even at the same dose. Therefore, if there is a risk of excessive dose to the skin, a dosimeter is attached to verify whether the correct dose is being investigated. However, since the skin dosimeter checks the attachment site visually by measuring a point dose, it is difficult to confirm an accurate dose distribution. As a result, the measurement and simulation errors of the material HgI2 in the 6 MV photon beam were 3.73% and 5.24%, respectively, at the minimum thickness of 25 ㎛, and the material PbI2 was 4.73% and 5.65%, respectively. On the other hand, as a result of the 6 MeV electron beam, the measurement and simulation errors of the material HgI2 were 1.35% and 1.12%, respectively, at a minimum thickness of 25 ㎛, and the material PbI2 showed relatively low attenuation error, 1.67% and 1.20%, respectively. Therefore, it was evaluated that the thickness of the photon beam within 25 ㎛ and the electron beam within 100 ㎛ is suitable to have a reduction rate error within 5%. This study presents a new research direction for a flexible dosimeter attached to the human body that is required in clinical practice and the construction conditions of a future skin dosimeter.