• 제목/요약/키워드: Direct transfer

검색결과 934건 처리시간 0.033초

새로운 수동제어소자인 공동을 이용한 마찰력과 열전달 감소에 관한 연구 (Cavity as a New Passive Device for Reduction of Skin Friction and Heat Transfer)

  • 한성현;최해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.463-466
    • /
    • 2002
  • In order to examine the possibility of using a cavity as a passive device for reduction of skin friction and heat transfer, an intensive parametric study over a broad range of the cavity depth and length at different Reynolds numbers is performed for both laminar and turbulent boundary layers in the present study. Direct and large eddy simulation techniques are used for turbulent boundary layers at low and moderate Reynolds numbers, respectively. for both laminar and turbulent boundary layers over a cavity, a flow oscillation occurs due to the shear layer instability when the cavity depth and length are sufficiently large and it plays an important role in the determination of drag and heat-transfer increase or decrease. For a cavity sufficiently small to suppress the flow oscillation, both the total drag and heat transfer are reduced. Therefore, the applicability of a cavity as a passive device for reduction of drag and heat transfer is fully confirmed in the present study. Scaling based on the wall shear rate of the incoming boundary layer is also proposed and it is found to be valid in steady flow over a cavity.

  • PDF

Experimental Investigation of Flow Boiling Heat Transfer of R-410A and R-134a in Horizontal Small Tubes

  • Pamitran, A.S.;Choi, Kwang-Il;Oh, Jong-Taek;Hrnjak, Pega
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1141-1146
    • /
    • 2009
  • Experimental investigation on two-phase flow boiling heat transfer of R-410A and R-134a in horizontal small tubes is reported. The pressure drop and local heat transfer coefficients were obtained over heat flux range of 5 to $40\;kW/m^2$, mass flux range of 70 to $600\;kg/m^2s$, saturation temperature range of 2 to $12^{\circ}C$, and quality up to 1.0 in test section with inner tube diameters of 3.0 and 0.5 mm, and lengths of 2000 and 330 mm, respectively. The section was heated uniformly by applying a direct electric current to the tubes. The effects of mass flux, heat flux, and inner tube diameter, on pressure drop and heat transfer coefficient are presented. The experimental results are compared against several existing correlations. A new boiling heat transfer coefficient correlation based on the superposition model for refrigerants in small tubes is developed.

  • PDF

마이크로핀관의 확관 전후 증발열전달 특성에 관한 실험적 연구 (An Experimental Study on Evaporative Heat Transfer Characteristics in Micro-Fin Tubes Before and After Expansion Process)

  • 전상희;황윤욱;윤석호;김민수
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.932-940
    • /
    • 2000
  • An experimental study on evaporative heat transfer characteristics in micro-fin tubes before and after expansion process has been performed with R-22. Single-grooved micro-fin tubes with outer diameter of 9.52 mm were used as test sections, and it was uniformly heated by applying direct current to the test tubes. Experiments were conducted at mass flow rates of 20 and 30 kg/hr. For each mass flow rate condition, evaporation temperature was set at 5 and $15^{\circ}C$and heat flux was changed from 6 to 11 kW/$m^2$ The evaporative heat transfer coefficient of micro-fin tubes after expansion is decreased because of the crush of fins and enlargement of inner diameter compared to that before expansion. Convective boiling effect decreased remarkably at higher quality range in the micro-fin tube after expansion, and the difference of the heat transfer coefficient in micro-fin tubes before and after expansion was greater for higher quality region. The evaporative heat transfer coefficient of the micro-fin tube after expansion was 19.9% smaller on the average than that before expansion.

  • PDF

$300{\mu}m$ 수평미세관내 R-410A의 비등열전달 특성 (Boiling Heat Transfer Characteristics of R-410A in $300{\mu}m$ Horizontal Smooth Microchannel)

  • 최광일;;;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.262-268
    • /
    • 2008
  • The present paper dealt with flow heat transfer characteristics of R-410A vaporization in horizontal smooth microchannel. The test sections were made of stainless steel tube with inner diameters of 300 mm and length of 300 mm. The refrigerant was supplied with mass flux range of 260-600 kg/$m^2s$ and applied under operating heat flux range of 5-20 kW/$m^2$ using a direct electric current heating method. The in let saturation temperature was set at $10^{\circ}C$ and vapor quality up to 1.0. The influences of mass flux, heat flux and inner tube diameter on local heat transfer coefficients were presented. Comparison with existing heat transfer coefficient correlations was performed. An improved heat transfer coefficient correlation for refrigerant vaporization in microchannel based on superposition model was developed with a mean deviation of 14.01%.

  • PDF

비외상센터에서 외상센터로의 전원이 예후에 미치는 영향 (Impact of interhospital transfer on outcomes for trauma patients: impact of direct versus non-direct transfer)

  • 양욱태;민문기;류지호;이대섭;이강호;신진욱;염석란;한상균
    • 대한응급의학회지
    • /
    • 제29권5호
    • /
    • pp.415-422
    • /
    • 2018
  • Objective: This study compared the prognosis of patients who visited the trauma center directly (direct visit group) with those transferred from the non-trauma center (transferred group). Methods: The patients, who were 18 or older with Injury Severity Score of 15 or more in the trauma center at Busan, were studied from October 2015 to October 2016. To compare the treatment time between the direct visit and transferred group, first treatment time, final treatment time, and time to visit the trauma center were examined. To compare the prognosis, this study compared the 48-hour, 7-day, and in-hospital mortality rate as well as the duration of intensive care unit (ICU) and total hospital stay. To analyze the factors affecting the outcome of transferred group, the physician's level and procedures that had been performed at the non-trauma center were examined. Results: The mortality was similar in the direct visit and transferred group (48-hour 7.6% vs. 4.6%, P=0.111; 7-day 11.1% vs. 7.2%, P=0.89; and in-hospital 14.6% vs. 11.3%, P=0.214). The length of ICU and total hospital stay were similar in the two groups. The mortality was higher in the patients in the transferred group when using intubation, transfusion, and pressure intensifier. The intubated patients showed higher mortality according to logistic regression. Conclusion: The mortality, length of ICU, and hospital stay were similar but the time to visit the trauma center and the final treatment time were longer in transferred group. Stabilizing the patient at the near non-trauma center may be more helpful for some patients.

竝進-振動에너지 變換에 있어서의 多量子 直接 振動 勵起 (Direct Non-stepwise Multiple Quantum Excitations in Translation-Vibration Energy Transfer)

  • 김유항;신형규
    • 대한화학회지
    • /
    • 제20권2호
    • /
    • pp.97-110
    • /
    • 1976
  • 竝進-振動에너지 變換에 있어서 中間에너지 準位를 거치지 않는 直接勵起가 多量子 振動천이에 미치는 영향을 理論的으로 조사하였다. 衝突 모형은 直線 충돌이며, 分子間의 포텐셜은 指數函數型의 것을 振動좌표(q)로 전개하고 四次項 $(q^4)$까지 包含시켜 사용하였다. $q^2$, $q^3$, $q^4$를 포함시켰을 때의 천이 확률 $(P_{m{\rightarrow}n})$에 對한 一般式을 各各 유도하고, 몇개의 충돌계에 대하여 그 값들을 계산하였다.結果를 線型化시킨 포텐셜(q)을 사용한 경우의 結果와 比較하고 直按 多量子 振動遷移가 重要한 役割을 하게 되는 條件 파라미터 ${\nalpha}$ 및 m과 관련시켜 제시하였다.

  • PDF

A Method of Finding Hidden Key Users Based on Transfer Entropy in Microblog Network

  • Yin, Meijuan;Liu, Xiaonan;He, Gongzhen;Chen, Jing;Tang, Ziqi;Zhao, Bo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권8호
    • /
    • pp.3187-3200
    • /
    • 2020
  • Finding key users in microblog has been a research hotspot in recent years. There are two kinds of key users: obvious and hidden ones. Influence of the former is direct while that of the latter is indirect. Most of existing methods evaluate user's direct influence, so key users they can find usually obvious ones, and their ability to identify hidden key users is very low as hidden ones exert influence in a very covert way. Consequently, the algorithm of finding hidden key users based on topic transfer entropy, called TTE, is proposed. TTE algorithm believes that hidden key users are those normal users possessing a high covert influence on obvious ones. Firstly, obvious key users are discovered based on microblog propagation scale. Then, based on microblogs' topic similarity and time correlation, the transfer entropy from ordinary users' blogs to obvious key users is calculated and used to measure the covert influence. Finally, hidden influence degrees of ordinary users are comprehensively evaluated by combining above indicators with the influence of both ordinary users and obvious ones. We conducted experiments on Sina Weibo, and the results showed that TTE algorithm had a good ability to identify hidden key users.

Investigation of Direct and Mediated Electron Transfer of Laccase-Based Biocathode

  • Jamshidinia, Zhila;Mashayekhimazar, Fariba;Ahmadi, Masomeh;Molaeirad, Ahmad;Alijanianzadeh, Mahdi;Janfaza, Sajad
    • Journal of Electrochemical Science and Technology
    • /
    • 제8권2호
    • /
    • pp.87-95
    • /
    • 2017
  • Enzymatic fuel cells are promising low cost, compact and flexible energy resources. The basis of enzymatic fuel cells is transfer of electron from enzyme to the electrode surface and vice versa. Electron transfer is done either by direct or mediated electron transfer (DET/MET), each one having its own advantages and disadvantages. In this study, the DET and MET of laccase-based biocathodes are compared with each other. The DET of laccase enzyme has been studied using two methods; assemble of needle-like carbon nanotubes (CNTs) on the electrode, and CNTs/Nafion polymer. MET of laccase enzyme also is done by use of ceramic electrode containing, ABTS (2,2'-azino-bis [3-ethylbenzthiazoline-6-sulphonic acid]) /sol-gel. Cyclic voltammetric results of DET showed a pair of well-defined redox peaks at $200{\mu}A$ and $170{\mu}A$ in a solution containing 5and $10{\mu}M$ o-dianisidine as a substrate for needle-like assembled CNTs and CNTs-Nafion composite respectively. In MET method using sol-gel/ABTS, the maximum redox peak was $14{\mu}A$ in the presence of 15 M solution o-dianisidine as substrate. The cyclic voltammetric results showed that laccase immobilization on needle-like assembled CNTs or CNTs-Nafion is more efficient than the sol-gel/ABTS electrode. Therefore, the expressed methods can be used to fabricate biocathode of biofuel cells or laccase based biosensors.

Direct Electrochemistry and Electrocatalysis of Myoglobin with CoMoO4 Nanorods Modified Carbon Ionic Liquid Electrode

  • Zhao, Zengying;Cao, Lili;Hu, Anhui;Zhang, Weili;Ju, Xiaomei;Zhang, Yuanyuan;Sun, Wei
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권2호
    • /
    • pp.475-481
    • /
    • 2013
  • By using ionic liquid 1-hexylpyridinium hexafluorophosphate ($HPPF_6$) based carbon ionic liquid electrode (CILE) as the substrate electrode, a $CoMoO_4$ nanorods and myoglobin (Mb) composite was casted on the surface of CILE with chitosan (CTS) as the film forming material to obtain the modified electrode (CTS/$CoMoO_4$-Mb/CILE). Spectroscopic results indicated that Mb retained its native structures without any conformational changes after mixed with $CoMoO_4$ nanorods and CTS. Electrochemical behaviors of Mb on the electrode were carefully investigated by cyclic voltammetry with a pair of well-defined redox peaks from the heme Fe(III)/Fe(II) redox center of Mb appeared, which indicated that direct electron transfer between Mb and CILE was realized. Electrochemical parameters such as the electron transfer number (n), charge transfer coefficient (${\alpha}$) and electron transfer rate constant ($k_s$) were estimated by cyclic voltammetry with the results as 1.09, 0.53 and 1.16 $s^{-1}$, respectively. The Mb modified electrode showed good electrocatalytic ability toward the reduction of trichloroacetic acid in the concentration range from 0.1 to 32.0 mmol $L^{-1}$ with the detection limit as 0.036 mmol $L^{-1}$ ($3{\sigma}$), and the reduction of $H_2O_2$ in the concentration range from 0.12 to 397.0 ${\mu}mol\;L^{-1}$ with the detection limit as 0.0426 ${\mu}mol\;L^{-1}$ ($3{\sigma}$).

직접 접촉식 4단 유동층 열교환기의 압력손실 및 열전달 특성 (The Pressure Drop and Heat Transfer Characteristics of a Direct Contact 4-Stage Fluidized Bed Heat Exchanger)

  • 임동렬;박상일;전광민
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.325-335
    • /
    • 1992
  • In this work, direct contact 4-stage fluidized bed heat exchanger is experimentally studied to develop a new type of heat exchanger which recovers the energy contained in the high temperature waste gas exhausted from the industrial furnaces. A sand is used as a heat transfer medium in this experiment. To determine the optimum operating condition, 11 different perforated plates which have a different free area ratio with different hole diameter are used in the experiment. From the room temperature experiment, the pressure drop which is caused by fluidized bed formation is observed. The high temperature experiment is carried out to seek the optimum operating condition of high heat efficiency at low heat exchanger operation cost. The results of experiment are as following. The pressure drop in the high temperature condition can be predicted from the results of the room temperature experiment. And Nusselt number becomes smaller due to the increased interference between sand particles as Reynolds number increases when the dilute phase fluidized beds are formed in nigh temperature condition. But heat transfer amount through the total sand surface area become larger due to the large resident amount of sand. Considering the heat transfer amount and the heat exchanger operation cost, perforated plates which have either a 30% or 35% of free area ratio with 15mm of hole diameter are best fitted for our goal of this work. The values of .phi. which is a dimensionless number representing the absorption heat amount per unit sand rate are in the range from 0.4 to 0.5, when Reynolds number of waste gas ranges from 25-30 with these perforated plates.