• Title/Summary/Keyword: Direct solar

Search Result 416, Processing Time 0.031 seconds

A study on the PWM(pulse witdh modulation) current source Inverter with utility (태양광발전 연계 시스템에 의한 PWM 전류형 인버어터에 관한 연구)

  • Hwang, Lak-Hoon;Choi, Ho-Kyu;Sin, Yang-Ho;Lee, Chun-Sang;Kim, Ju-Rae;Jo, Sang-Rou;Jo, Moon-Taeck
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1020-1022
    • /
    • 2001
  • because the output of solar cell is direct, it is necessary to install D/A converter system for A.C load, and in case of driving utility line system, it is possible to drive system relation when the system supplies sinusodal current ant voltage having unit power factor. As the characteristics of the soar cell output the is influenced by dailysunight charge, for more electric power it is essential to control the direction toward the san so that the driving point of solar cell can always operate near maximum output point. PWM modulation device among electric power converters must have stable modulation at anytime when it includes noise-factors such as noise-wave and noises on electric voltage wave, a synchronous signal system. In dealing with synchronous signal for control and control signal by microprocessor, it is necessary to compensate it because there is time difference between sample paint and carrier wave. On this papers, single phase PWM current type invertor controled the solar cell having typical voltage dropping character has optimun short current in short, reduces D.C reactance, composes controller for modulation and keeps lower harmonic and high power factor keeping maximum output of solar cell according daily sunlight charge variation.

  • PDF

Characteristics of ITO/Ag-Pd-Cu/ITO Multilayer Electrodes for High Efficiency Organic Solar Cells

  • Kim, Hyo-Jung;Kang, Sin-Bi;Na, Seok-In;Kim, Han-Ki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.257.1-257.1
    • /
    • 2014
  • We investigated characteristics of ITO/Ag-Pd-Cu (APC)/ITO multilayer electrodes prepared by direct current magnetron sputtering for use as an anode in organic solar cells (OSCs). To optimize electrical properties of ITO/APC/ITO multilayer, we fabricated the ITO/APC/ITO multilayer at a fixed ITO thickness of 30 nm as a function of APC thickness. Compare to the surface of Ag layer on ITO, the APC had a smooth surface morphology. At optimized APC thickness of 12 nm, the ITO/APC/ITO multilayer exhibited a sheet resistance of $6{\Omega}/square$ and optical transmittance of 84.15% at a wavelength of 550 nm which is comparable to conventional ITO/Ag/ITO multilayer. However, the APC-based ITO multilayer showed a higher average transmittance in a visible region than the Ag-based ITO multilayer. The higher average transmittance of ITO/APC/ITO multilayer indicated the multilayer is suitable anode for organic solar cells with P3HT:PCBM active layer. OSCs fabricated on the optimized ITO/ACP/ITO multilayer exhibited a better performance with a fill factor of 64.815%, a short circuit current of $8.107mA/cm^2$, an open circuit voltage of 0.59 V, and power conversion efficiency (3.101%) than OSC with ITO/Ag/ITO multilayer (2.8%).

  • PDF

The Characteristics of the winter season window and indoor temperature due to the indoor plant (동계 이중외피와 내부식재에 의한 실내 온도 특성에 관한 연구)

  • Yun, Young-Il;Cho, Ju-Young
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.107-112
    • /
    • 2015
  • Purpose: This study desires to investigate an effect of indoor temperature, humidity, and illuminance targeting a planting system of double-skin facade and cavity space adjacent to the outside within a certain period of winter. Through this, the study suggests a basic material about an energy conservation effect of double window system using planting to reduce heating load of a building in winter, so desires to contribute to indoor thermal comfort effect and illuminance correction study of double window and indoor plant. Method: Considering effects such as day and night climatic elements and air conditions in winter, illuminance measurement was conducted through a double-skin facade of space, a subject of the measurement, on the basis of practical residence time of a resident, and this study analyzed characteristics of indoor illuminance about this. The study measured and compared a change of insolation, dry-bulb temperature, and relative humidity at each indoor-outdoor measuring point, so measured and compared characteristics of an indoor temperature effect by elements of double-skin facade and indoor plant. Result: Through this study, the researcher could determine that indoor plant within double window in winter not only blocks solar radiation but also photosynthesizes, so is somewhat disadvantageous to winter thermal comfort reducing heating load. In addition, solar radiation going through interior plays a role to bring down somewhat high humidity to about 50% of reasonable humidity, so plays a direct role of maintenance of comfortable indoor space. Although there are effects such as blocking of solar radiation and temperature reduction, this has a positive influence on humidity control and proper illuminance distribution. The researcher could determine that illuminance, temperature, and humidity by solar radiation penetration for the whole measuring time play a role to supplement indoor environment mutually.

Meteorological Data Measured under Agrivoltaic Systems in Boseong-gun during Winter Barley Season (영농형 태양광 시설 하부의 미기상 관측 자료: 보성에서 2019년 11월부터 2020년 5월까지 가을보리 재배기간 동안)

  • Cho, Yuna;Yoon, Changyong;Kim, Hyunki;Moon, Hyundong;An, Kyu-Nam;Cho, Jaeil
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.3
    • /
    • pp.144-151
    • /
    • 2020
  • Agrivoltaic systems (AVS) is defined as combining farm-grown crops with photovoltaic panels (PV) installed several meters above the ground. Solar radiation (W/㎡), photosynthetic photon flux density (PPFD, µmol/㎡/s), air temperature (℃), vapor pressure (kPa), soil moisture (㎥/㎥), soil temperature (℃), wind direction (˚), and wind speed (m/s) were measured under the AVS in Boseong-gun during winter barley season. Data was collected by 5 minute interval. All data can download at Github site (https://github.com/chojaeil/AVS_Boseung). To gap-filling missing solar radiation data during about two weeks, the conversion coefficient from solar radiation to PPFD was estimated as 0.41. Further, according to the ratio of diffuse radiation to direct radiation, the maximum value among the twenty PPFD sensors under the AVS was related to the PPFD value of filed.

Improved Performance of CdS/CdTe Quantum Dot-Sensitized Solar Cells Incorporating Single-Walled Carbon Nanotubes

  • Shin, Hokyeong;Park, Taehee;Lee, Jongtaek;Lee, Junyoung;Yang, Jonghee;Han, Jin Wook;Yi, Whikun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.10
    • /
    • pp.2895-2900
    • /
    • 2014
  • We fabricated quantum dot-sensitized solar cells (QDSSCs) using cadmium sulfide (CdS) and cadmium telluride (CdTe) quantum dots (QDs) as sensitizers. A spin coated $TiO_2$ nanoparticle (NP) film on tin-doped indium oxide glass and sputtered Au on fluorine-doped tin oxide glass were used as photo-anode and counter electrode, respectively. CdS QDs were deposited onto the mesoporous $TiO_2$ layer by a successive ionic layer adsorption and reaction method. Pre-synthesized CdTe QDs were deposited onto a layer of CdS QDs using a direct adsorption technique. CdS/CdTe QDSSCs had high light harvesting ability compared with CdS or CdTe QDSSCs. QDSSCs incorporating single-walled carbon nanotubes (SWNTs), sprayed onto the substrate before deposition of the next layer or mixed with $TiO_2$ NPs, mostly exhibited enhanced photo cell efficiency compared with the pristine cell. In particular, a maximum rate increase of 24% was obtained with the solar cell containing a $TiO_2$ layer mixed with SWNTs.

Simultaneous treatment of Cr(VI) and EDCs using flat type photocatalytic reactor under solar irradiation (평판형 태양광반응기를 이용한 복합오염물질의 동시처리 연구)

  • Kim, Saewon;Cho, Hyekyung;Joo, Hyunku;Her, Namguk;Yi, Kwangbok;Kim, Jong Oh;Yoon, Jaekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.501-509
    • /
    • 2016
  • In this study, a flat-type photocatalytic reactor is applied under solar irradiation for simultaneous treatment of target pollutants: reduction of Cr(VI) to Cr(III) and oxidation of EDCs (BPA, EE2, E2). An immobilized type of photocatalyst was fabricated to have self-grown nanotubes on its surface in order to overcome limitations of powdery photocatalyst. Moreover, Ti mesh form was chosen as substrate and modified to have both larger surface area and photocatalyst content. Ti mesh was anodized at 50V and $25^{\circ}C$ for 30min in the mixed electrolytes ($NH_4F-H_2O-C_2H_6O_2$) and annealed at $450^{\circ}C$ for 2 hours in ambient oxygen to have anatase structure. Surface characterization was done with SEM and XRD methodologies. Fabricated NTT was applied to water treatment, and coexisting Cr(VI) and organics (EDCs) enhanced each other's reactions by scavenging holes and electrons and thus impeding recombination. Also, several experiments were conducted outdoor under direct sunlight and it was observed that both solar-tracking and applying modified photocatalyst were proven to enhance reaction efficiency.

Comparative Analysis on the Characteristic of Typical Meteorological Year Applying Principal Component Analysis (주성분분석에 의한 TMY 특성 비교분석)

  • Kim, Shin Young;Kim, Chang Ki;Kang, Yong Heack;Yun, Chang Yeol;Jang, Gil Soo;Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.67-79
    • /
    • 2019
  • The reliable Typical Meteorological Year (TMY) data, sometimes called Test Reference Year (TRY) data, are necessary in the feasibility study of renewable energy installation as well as zero energy building. In Korea, there are available TMY data; TMY from Korea Institute of Energy Research (KIER), TRY from the Korean Solar Energy Society (KSES) and TRY from Passive House Institute Korea (PHIKO). This study aims at examining their characteristics by using Principle Component Analysis (PCA) at six ground observing stations. First step is to investigate the annual averages of meteorological elements from TMY data and their standard deviations. Then, PCA is done to find which principle components are derived from different TMY data. Temperature and solar irradiance are determined as the main principle component of TMY data produced by KIER and KSES at all stations whereas TRY data from PHIKO does not show similar result from those by KIER and KSES.

Design and Performance Analysis of Conical Solar Concentrator

  • Na, Mun Soo;Hwang, Joon Yeal;Hwang, Seong Geun;Lee, Joo Hee;Lee, Gwi Hyun
    • Journal of Biosystems Engineering
    • /
    • v.43 no.1
    • /
    • pp.21-29
    • /
    • 2018
  • Purpose: The objective of this study is to evaluate the performance of the conical solar concentrator (CSC) system, whose design is focused on increasing its collecting efficiency by determining the optimal conical angle through a theoretical study. Methods: The design and thermal performance analysis of a solar concentrator system based on a $45^{\circ}$ conical concentrator were conducted utilizing different mass flow rates. For an accurate comparison of these flow rates, three equivalent systems were tested under the same operating conditions, such as the incident direct solar radiation, and ambient and inlet temperatures. In order to minimize heat loss, the optimal double tube absorber length was selected by considering the law of reflection. A series of experiments utilizing water as operating fluid and two-axis solar tracking systems were performed under a clear or cloudless sky. Results: The analysis results of the CSC system according to varying mass flow rates showed that the collecting efficiency tended to increase as the flow rate increased. However, the collecting efficiency decreased as the flow rate increased beyond the optimal value. In order to optimize the collecting efficiency, the conical angle, which is a design factor of CSC, was selected to be $45^{\circ}$ because its use theoretically yielded a low heat loss. The collecting efficiency was observed to be lowest at 0.03 kg/s and highest at 0.06 kg/s. All efficiencies were reduced over time because of variations in ambient and inlet temperatures throughout the day. The maximum efficiency calculated at an optimum flow rate of 0.06 kg/s was 85%, which is higher than those of the other flow rates. Conclusions: It was reasonable to set the conical angle and mass flow rate to achieve the maximum CSC system efficiency in this study at $45^{\circ}$ and 0.06 kg/s, respectively.

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.

Applicability of Daily Solar Radiation Estimated by Mountain Microclimate Simulation Model (MT-CLIM) in Korea (MT-CLIM 프로그램을 이용한 일별 일사량 추정의 국내 적용성 검토)

  • Shim, Kyo Moon;Kim, Yong Seok;Lee, Deog Bae;Kang, Ki Keong;So, Kyo-Ho
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.4
    • /
    • pp.260-264
    • /
    • 2012
  • Accuracy of daily solar radiation estimated from a Mountain Microclimate Simulation Model (MT-CLIM) was assessed for seven observation sites with complex topography in Uiseong County. The coefficient of determination ($R^2$) between the observed and the estimated daily solar radiation was 0.52 for 7 sites for the study period from 1 August to 30 September 2009. Overall, the MT-CLIM overestimated the solar radiation with root mean square error (RMSE) of $3.83MJ\;m^{-2}$ which is about 25% of the mean daily solar radiation ($15.27MJ\;m^{-2}$) for the study period. Considering that the pyranometer's tolerance is ${\pm}5%$ of standard sensor, the RMSE of MT-CLIM was too large to accept for a direct application for agricultural sector. The reliability of solar radiation estimated by MT-CLIM must be improved by considering additional ways such as using a topography correction coefficient.