• Title/Summary/Keyword: Direct retainer

Search Result 16, Processing Time 0.026 seconds

STRESS ANALYSIS OF ABUTMENT FOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE BY CLASP DESIGN AND IMPRESSION METHOD (편측후방연장 국소의치에서 인상채득 방법과 클라스프 설계에 따른 지대치의 응력분석에 관한 연구)

  • Ahn Hee-Young;Kim Kwang-Jun;Cho Hye-Won;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.547-555
    • /
    • 2001
  • This study was performed tn investigate the effects of impression method and design of the retainer on the stress of abutment tooth in distal extension RPD. Three different types of direct retainer such as Akers clasp, RPI clasp, and wrought wire clasp were designed. Stress on the abutment tooth was measured and analyzed with strain gauge method. Impressions were anatomic impression technique and functional impression technique. The following conclusions were drawn from this study. 1. The stress at the abutment tooth on all RPD was decreased in functional impression except RPI clasp retained RPD. 2 The stress at the abutment tooth on RPI clasp retained RPD was the most smallest in anatomic Impression. 3. While load is increase the stress at the abutment tooth was increased, but the change of stress at the buccal side of abutment tooth was not too much in functional impression.

  • PDF

EFFECTS OF ABUTMENT SPLINTING ON STRESS DISTRIBUTION IN UNILATERAL DISTAL EXTENSION RPD (지대치 연결고정에 따른 편측성 후방연장 국소의치에서의 응력분포)

  • Ahn Hee-Young;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.154-166
    • /
    • 2004
  • Statement of problem: In distal extension removable partial denture, the preservation of health of abutment teeth are very important, but they are always subjected to unfavorable stress. Purpose: The purpose of this study was performed to investigate the effects of abutment splinting and design of direct retainer on the stress distribution of abutments in unilateral distal extension removable partial dentures. Material and method: Abutments were splinted by different method. In group 1, autment teeth were not splinted, in group 2, canine and 1st premolar were splinted, and in group 3, canine, 1st and 2nd premolars were all splinted. Three different types of direct retainer such as Akers clasp, RPI clasp, and wrought wire clasp were designed. Strain was measured with Switch & Balance Unit(SB-10, Measurement Group Instruments Division, Raleigh USA) and Strain Indicator(P-3500, Measurement Group Instruments Division, Raleigh, USA) 15kg of vertical and oblique loads was applied at central fossa of missing 2nd molar area. Results : The strain on lingual side of 2nd premolar was the greatest, and abutment splinting induced decrease of strain on buccolingual side of 2nd premolar. The strain of loaded area was decreased by abutment splinting and there was no statistical difference of strain between Group2 and Group 3, and strain on 2nd premolar in wrought wire clasp was the least. Conclusion: Within the limitations of this study, splinting of two distal abutment teeth is enough for stress distribution widely, and wrought wire clasp was more benefitable than others.

A SURVEY OF PARTIAL EDENTULISM AND REMOVABLE PARTIAL DENTURE DESIGNS FOR PATIENTS IN KOREA (한국인의 부분 치아 결손 증례와 국소의치 설계에 관한 연구)

  • Lee Si-Hyuk;Chang Ik-Tae;Kim Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.235-248
    • /
    • 1994
  • There were many studies that distribute the partial edentulous states and examine the removable partial denture designs in the planning of removable partial denture treatment. This study was performed in the point of removable partial denture prescription to evaluate partial edentulism and its removable partial denture designs. The data was collected from the dental laboratory of each three dental colleges in Seoul and from two dental laboratories only for removable partial dentures as a prescription form. A total of 1411 cases with prescription form collected from dental laboratories were distributed for this study, then 788 cases were selected for this study. The case selection was done according to the contents of prescription form. The selected cases were divided into maxillary arch and mandibular and classified in terms of types of major connector and direct retainer, unbroken anterior teeth, Kennedy classification, the number of remaining teeth, and distribution of age and sex. The analyzed results were as follows : 1. The Kennedy classification I showed highest frequency both in maxilla and mandible. 2. The arch distribution of removable partial denture was 50.08% for maxilla and 49.92% for mandible. 3. The highest frequency in the distribution of direct retainer was the RPA clasp design. 4. The frequency of unbroken anterior 6 was 73.36% for maxilla and 82.30% for mandible. 5. The design of broad palatal strap and lingual bar revealed the highest prevalence in the major connector construction. 6. The mean number of remaining teeth per arch was 8.25 for maxilla and 8.37 for mandible. 7. The mean age of the patients supplied with removable partial denture was 52.25 years for men, 51.68 years for women, 52.11 years for maxilla, and 51.76 years for mandible and women showed more prevalence.

  • PDF

PHOTOELASTIC STRESS ANALYSIS ON THE SUPPORTING TISSUE OF MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE WITH VARIOUS DESIGN OF DIRECT RETAINERS (직접유지장치 설계 변화에 따른 하악 후방연장 국소의치 지지조직의 광탄성 응력분석)

  • Lee Chang-Ho;Kim Kwang-Nam;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.203-224
    • /
    • 1992
  • The purpose of this study was to evaluate the stress distribution developed in supporting structures by distal extension removable partial denture with 4-types of direct retainer. The direct retainers examined were Akers clasp, RPI clasp, RPA clasp and RPL clasp in bilateral & unilateral free end case. 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns and to calculate the compressive stress at measuring points. The results were as follows. 1. In bilateral free end case, RPI clasp exhibited the similar stress distribution on distal and mesial alveolar crest but Akers clasp exhibited higher stress concentration on distal alveolar crest than mesial alveolar crest. 2. In bilateral free end case, RPA clasp and RPL clasp exhibited the similar stress distribution on distal and mesial alveolar crest and RPL clasp exhibited higher stress concentration on buccal alveolar crest than lingual alveolar crest. 3. Akers clasp produced high stress concentration on residual alveolar ridge distally, but RPI clasp, RPA clasp and RPL clasp produced even stress distribution on residual alveolar ridge. 4. Removable partial denture in unilateral free end case exerted higher stress on abutment tooth root apex than bilateral distal extension removable partial denture.

  • PDF

A clincal study of Kennedy classification and framework design of removable partial denture in Kyungpook National University hospital (경북대학교 병원에 내원한 국소의치 장착 환자의 Kennedy 분류에 따른 분포상황 및 그 설계특성에 관한 연구)

  • Cha, Phill-Seon;Jeong, In-Yeong;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.189-193
    • /
    • 2010
  • Purpose: This study was aimed to investigate the frequency of different classes of partial edentulism and the most frequently used design components of conventional removable partial dentures. Materials and methods: 63 patients who were treated with removable partial denture in Kyungpook National University hospital for 2003-2006 were selected. A total of 76 removable partial denture frameworks were investigated. Kennedy classification was used to identify the class of partial edentulism. Results: Results indicated that Kennedy class I removable partial dentures were the most frequently constructed. Most patients' cases were designed without modification areas. Conclusion: The most common type of direct retainer were the RPI clasp and RPA clasp in both maxilla and mandible. Lingual bar, linguoplate and anterior posterior palatal straps were the more frequently used mandibular and maxillary major connectors respectively. We did not have any case about Kennedy class IV patients.

A Clinical Study on CSP Attachment Partial Denture (CSP 를 이용한 정밀부착형 국부의치에 관한 임상적 연구)

  • Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.7-16
    • /
    • 1981
  • The technology of precision attachments has developed at such a pace that from a very few T-shaped attachments and bar attachments from the years 1915 to 1935 since removable bridge utilizing a T-shaped intracoronal attachment was constructed by Dr. Herman E.S. Chayes in 1906. There are now more than 120 models of the most diversified designs, ready made or laboratory fashioned. In 1971, 126 attachments were listed and classified by Mensor in his E M Attachment Selector. This selector consists of five charts giving specifications as to type, vertical dimensions, application, type of resilience, size of movement, type of retention and type of material and alloy. Thus the E M Attachment Selector is a useful guide for dentists to choose the attachment for his patients. But dentists should apply the attachment in each patient's case according to an accurate diagnosis and treatment plan. This paper is a case report of removable partial dentures utilizing CSP, PD and Bar attachment on a patient who needed full mouth reconstruction. Patient has right first, second molar and left first molar on the upper arch and also left first molar, first premolar and right canine on the lower arch. (Fig. 5)All remaining teeth are relatively healthy in their supporting tissues. On upper arch, ring shape CSP attachment was designed on left first molar and modified ring shape CSP attachment was designed on right first and second molar as the direct retainer of the removable partial denture. Full palatal coverage was used as the major connector in this case. (Fig. 23) On lower arch, author first splinted with a fixed bridge between left first molar and second premolar and a splint bar between left second premolar and right canine. (Fig. 11) A lower removable partial denture in which was designed with an Aker clasp on the left first molar and a PD attachment on .the right canine was constructed. (Fig. 17) This denture could get additional support from anterior splint bar. After both removable partial dentures were delivered to the patient (Fig. 26), author evaluated function of the dentures and supporting structures of the abutment teeth by means of clinical and X-ray examinations for eighteen months. According to the examination data author came to the conclusion that the prognosis of this case was excellent.

  • PDF