• 제목/요약/키워드: Direct instrument method

검색결과 56건 처리시간 0.024초

인구통계적 변인에 따른 노년 여성의 외모관심과 자신감에 관한 연구 (A Study on Appearance Interest and Self-Confidence of Elderly Women Associated with Demographic Variables)

  • 이명희;이은실
    • 한국의류학회지
    • /
    • 제21권6호
    • /
    • pp.1072-1081
    • /
    • 1997
  • The objectives of this study were to investigate the differences in appearance interest (clothing interest and body adornment) and self-confidence according to demographic variables such as age, education, and allowance, to examine the causal relationships of clothing interest and body adornment on self-confidence of elderly women. Subjects for this study were samples of 215 elderly women (ages 60 to 70) in Seoul, Korea. The instrument was a questionnaire and the survey was done in face-to-face method. 1. There was a significant difference in body adornment according to age. After age was controlled, there were significant differences in appearance interest and self-confidence according to education. There were significant differences in appearance interest and self- confidence according to allowance. 2. Education and allowance had a direct effect on clothing interest. Allowance, age, and education had a direct effect on body adornment. Education had a direct effect on allowance. 3. Clothing interest and allowance had a direct effect, and education had an indirect effect on self-confidence. Body adornment and allowance had a direct effect on self-confidence, education and age had an indirect effect on self-confidence. The present findings provide that appearance interest such as, clothing interest and body adornment had a significant effect on self-confidence of elderly women. It appeared that the connection between body adornment and allowance was stronger than the connection between clothing interest and allowance. The causal relationship of clothing interest on self- confidence was stronger than the causal relationship of body adornment on self-confidence. The clothing interest was a variable that most affected on self-confidence of elderly women.

  • PDF

위생용지 부드러움의 객관적 평가 방법 개발 및 표준화 (Development of an Objective Softness Evaluation Method and Its Standardization for Hygiene Paper)

  • 고영찬;박종문;문병근
    • 펄프종이기술
    • /
    • 제47권5호
    • /
    • pp.80-84
    • /
    • 2015
  • Softness is considered one of the most important attributes of hygiene paper such as tissue and towel. Being subjective in nature, however, softness attribute has been generally believed to be impossible to evaluate using objective methods. Hallmark in his pioneering work proposed that tissue subjective softness should be mainly consisted of the bulk softness component and surface softness component. The bulk softness component can be determined by tensile stiffness; the surface softness component by surface tester. The surface friction turns out far more important than the surface roughness in determining the surface softness component. It cannot be too much emphasized that both results of the tensile stiffness and the surface friction should depend on measuring conditions such as an instrument used, sample sizes (e.g., basis weight, length, and width) and operating conditions of the instrument (e.g., gauge length, cross-head speed, size of stylus, and its scanning speed). This indicates that a direct comparison of the test results would be impossible or misleading unless they have been tested under the identical conditions. This may explain why the standard objective test method for tissue softness has not been available at present.

임상보고 가능범위의 실증적 연구 (An Empirical Study of the Clinically Reportable Range in Clinical Chemistry)

  • 장상우;이상곤;최호성;송은영;박용원;이인애
    • 대한임상검사과학회지
    • /
    • 제39권1호
    • /
    • pp.31-36
    • /
    • 2007
  • The purpose of the clinically reportable range (CRR) in clinical chemistry is to estimate linearity in working range. The reportable range includes all results that may be reliably reported, and embraces two types of ranges: the analytical measurement range (AMR) is the range of analyte values that a method can directly measure on the specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. CAP and JCAHO require linearity on analyzers every six months. The clinically reportable range is the range of analyte values that a method can measure, allowing for specimen dilution, concentration, or other pretreatment used to extend the direct analytical measurement range. The AMR cannot exceed the manufacturer's limits. Establishing AMR is easily accomplished with Calibration Verification Assessment and experimental Linearity. For example: The manufacturer states that the limits of the AST on their instrument are 0-1100. The lowest level that could be verified is 2. The upper level is 1241. The verified AMR of the instrument is 2-1241. The lower limit of the range is 2, because that is the lowest level that could be verified by the laboratory. The laboratory could not use the manufacturer's lower limit of 2 because they have not proven that the instrument values below 2 are valid. The upper limit of the range is 1241, because although the lab has shown that the instrument is linear to 1241, the manufacturer does not make that claim. The laboratory needs to demonstrate the accuracy and precision of the analyzer, as well the validation of the patient AMR. Linearity requirements have been eliminated from the CLIA regulations and from the CAP inspection criteria, however, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. If a lab chooses to continue linearity studies, these studies must fully comply with the calibration/calibration verification requirements of CLIA and/or CAP. The results of lower limit and upper limit of clinically reportable range were total protein (2.1 - 79.9), albumin (1.3 - 39), total bilirubin (0.2 - 106.2), alkaline phosphatase (13 - 6928.2), aspartate aminotransferase (24 - 7446), alanine aminotransferase (13 - 6724.2), gamma glutamyl transpeptidase (16.64 - 9904.2), creatine kinase (15.26 - 4723.8), lactate dehydrogenase (127.66 - 13231.8), creatinine (0.4 - 129.6), blood urea nitrogen (8.67 - 925.8), uric acid (1.6 - 151.2), total cholesterol (48.52 - 3162), triglycerides (36.91 - 3367.8), glucose (31 - 4218), amylase (21 - 6694.2), calcium (3.1 - 118.2), inorganic phosphorus (1.11 - 108), HDL (11.74 - 666), NA (58.3 - 1800), K (1.0 - 69.6), CL (38 - 1230).

  • PDF

콘크리트 슬래브궤도에서 레일과 철근 사이의 결합계수에 대한 연구 (A Study on Coupling Coefficient Between Rail and Reinforcing Bars in Concrete Slab Track)

  • 김민석;이상혁;이종우
    • 한국철도학회논문집
    • /
    • 제12권3호
    • /
    • pp.405-411
    • /
    • 2009
  • 고속철도 신호시스템은 ATC시스템을 이용하여 열차의 제한속도를 송신하고, 일부 도시철도 신호시스템은 이동가능거리를 전송한다. 열차제어정보전송은 직접 궤도를 이용하여 차상에 전송하는 방식, 궤도상에 기기를 설치하여 전송하는 방식, 선로변에 기기를 전송하는 방식이 있다. 직접궤도를 도체로 활용하여 궤도를 회로일부로 구성하고, 궤도에 신호를 전송하여 열차가 궤도에서 열차제어 정보를 획득하는 방법으로, 궤도회로를 사용하며, 고속철도, 지하철에서 사용하고 있다. 궤도회로를 사용하는 방식은 반송신호에 정보를 실어서 보내며, 차상장치는 자기결합에 의해서 정보를 획득한다. 콘크리트 슬래브궤도에는 많은 철근을 사용하기 때문에 자갈도상의 궤도에서는 발생되지 않았던 레일과 철근간의 상호작용이 발생한다. 레일과 철근간의 상호작용이 발생하여 레일의 전기적 특성이 변화된다. 본 논문에서는 경부고속철도 2단계 구간에서 사용되는 콘크리트 슬래브궤도에서 레일과 철근 사이의 모델을 이용하여 콘크리트 슬래브궤도의 모델로부터 레일과 철근 사이의 결합계수를 수리적으로 해석하고, 레일과 철근간의 상호작용이 일어나지 않는 경우, 즉 철근에 의한 레일의 전기적 특성의 변화가 없는 결합계수를 정의하였다.

Maximum Canopy Height Estimation Using ICESat GLAS Laser Altimetry

  • Park, Tae-Jin;Lee, Woo-Kyun;Lee, Jong-Yeol;Hayashi, Masato;Tang, Yanhong;Kwak, Doo-Ahn;Kwak, Han-Bin;Kim, Moon-Il;Cui, Guishan;Nam, Ki-Jun
    • 대한원격탐사학회지
    • /
    • 제28권3호
    • /
    • pp.307-318
    • /
    • 2012
  • To understand forest structures, the Geoscience Laser Altimeter System (GLAS) instrument have been employed to measure and monitor forest canopy with feasibility of acquiring three dimensional canopy structure information. This study tried to examine the potential of GLAS dataset in measuring forest canopy structures, particularly maximum canopy height estimation. To estimate maximum canopy height using feasible GLAS dataset, we simply used difference between signal start and ground peak derived from Gaussian decomposition method. After estimation procedure, maximum canopy height was derived from airborne Light Detection and Ranging (LiDAR) data and it was applied to evaluate the accuracy of that of GLAS estimation. In addition, several influences, such as topographical and biophysical factors, were analyzed and discussed to explain error sources of direct maximum canopy height estimation using GLAS data. In the result of estimation using direct method, a root mean square error (RMSE) was estimated at 8.15 m. The estimation tended to be overestimated when comparing to derivations of airborne LiDAR. According to the result of error occurrences analysis, we need to consider these error sources, particularly terrain slope within GLAS footprint, and to apply statistical regression approach based on various parameters from a Gaussian decomposition for accurate and reliable maximum canopy height estimation.

글로우방전을 이용한 새로운 정밀분석기기의 개발 및 금속시료의 직접분석법에 관한 연구 (Development of a New Analytical Instrument with Glow Discharge System and Studies on the Direct Solid Analysis Method)

  • 박정화;김효진;우진춘;박창준;문대원;이광우
    • 대한화학회지
    • /
    • 제36권2호
    • /
    • pp.273-281
    • /
    • 1992
  • 원자흡수분광법을 위한 글로우방전 분광 장치를 sputtering된 시료원자가 기저상태의 원자가 최대이며 여기 상태의 원자가 최소가 되는 지역을 측정하도록 설계 개발하였다. 빠른 속도의 가스 jet는 방전의 육안 및 전기적 변화 뿐만 아니라 시료표면의 변화에서 처럼 시료가 원자화되는 양을 현저히 증가시킨다. 가스 jet는 원자흡수분광법으로 시료를 직접할 수 있는 가능성을 보여주었다. 감도와 재현성에 영향을 끼치는 여러 가지 요인들에 관하여 연구하였다.

  • PDF

선박용 4행정 디젤엔진의 정속 부하변동 운전시 매연배출특성에 대한 실험연구 (An Experimental Study on the Emission Characteristics of Smoke from the Marine Four-Stroke Diesel Engines Operated in Constant Speed and Various Load Steps)

  • 오상훈;김재민;김현규;유봉환
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.19-20
    • /
    • 2006
  • The emission of particulate matter from marine diesel engines is already restricted by regional regulations in some countries, and IMO has been preparing the regulation for particulate matter from 53rd MEPC. But confusingly, the gravimetric PM measurement methods and procedures are not established clearly yet. On the other hand, smoke measurement method is set clearly, and it can also indicate PM, though it is not direct gravimetric method. As the preparing step for regulations about PM, we measured the smote density of exhaust emission from the marine four-stroke diesel engines operated in constant speed and various load steps on the test-bed, using the filter-type smoke measuring instrument. As a result, we understood the omission characteristics of smoke from the engines. Additionally, to obtain the objective reliability of our measurement data, we carried out experimental studies about various measuring parameters that could affect the smoke density.

  • PDF

Traditional and minimally invasive access cavities in endodontics: a literature review

  • Ioanna Kapetanaki;Fotis Dimopoulos ;Christos Gogos
    • Restorative Dentistry and Endodontics
    • /
    • 제46권3호
    • /
    • pp.46.1-46.9
    • /
    • 2021
  • The aim of this review was to evaluate the effects of different access cavity designs on endodontic treatment and tooth prognosis. Two independent reviewers conducted an unrestricted search of the relevant literature contained in the following electronic databases: PubMed, Science Direct, Scopus, Web of Science, and OpenGrey. The electronic search was supplemented by a manual search during the same time period. The reference lists of the articles that advanced to second-round screening were hand-searched to identify additional potential articles. Experts were also contacted in an effort to learn about possible unpublished or ongoing studies. The benefits of minimally invasive access (MIA) cavities are not yet fully supported by research data. There is no evidence that this approach can replace the traditional approach of straight-line access cavities. Guided endodontics is a new method for teeth with pulp canal calcification and apical infection, but there have been no cost-benefit investigations or time studies to verify these personal opinions. Although the purpose of MIA cavities is to reflect clinicians' interest in retaining a greater amount of the dental substance, traditional cavities are the safer method for effective instrument operation and the prevention of iatrogenic complications.

Air abrasive technique을 이용한 복합레진 수복 증례 (TREATMENT OF COMPOSITE RESIN RESTORATION WITH THE AIR ABRASIVE TECHNIQUE)

  • 이창우;장기택;이상훈;한세현
    • 대한소아치과학회지
    • /
    • 제24권4호
    • /
    • pp.763-770
    • /
    • 1997
  • The air abrasive technique is a non-mechanical method by which teeth are treated before restoration and stains and calculi are removed from tooth surfaces using the kinetic energy of small particles. The air abrasive technique in dentistry was first introduced in the 1950's with as instrument called 'Airdent'. But, as the main restorative materials of the period were amalgam and gold, and the instrument's inability to control the flow of particles caused the particles to be spread throughout the clinics, widespread use was not possible. In the 1990's, as these techincal problems were solved and more interest in new restorative materials rose in an effort to preserve sound tooth structure, new developements took place in instruments related to the air abrasive technique. The air abrasive technique produces less pressure, vibration and heat that might cause patient discomfort and facilitates the preservation of sound tooth structure. It also reduces the need for anesthesia and is less harmful to the pulp. Other advantages include increase in dentin bonding strength of composite resin, lower possibility of saliva contamination and maintenance of a dry field. But there is not direct contact between the nozzle and the tooth, the operator cannot use his or her tactile sense and must rely solely upon visual input. Other disadvantages are: the tooth preparation depends on the operator's ability; alpha-alumina particles, after bouncing off the tooth surface, cause damage to dental mirrors; the equipment is expensive and takes up a certain amount of space in the clinic. The author conducted case report using the air abrasive technique on patient visiting the Department of Pediatric Dentistry at Seoul National University Dental Hospital and arrived at the following conclusions. 1. The tooth preparation capability of different air abrasive devices varied widely among manufacturers. 2. It was more effective in treating early caries lesions and stains compared to lesions where caries had already progressed to produce soft dentin. 3. The cold stream and noise caused by the evacuation system was a major cause of discomfort to pediatric patients. 4. As there is no direct contact with tooth surface when using the air abrasive technique for tooth preparation, considerable experience and skill is required for proper tooth preparation.

  • PDF

개의 발정 진단 방법에 따른 효율 비교 (Comparison of Various Methods for Estrus Stage Determination in Bitch)

  • 고영진;강은주;이성림
    • 한국수정란이식학회지
    • /
    • 제24권3호
    • /
    • pp.131-137
    • /
    • 2009
  • In dogs, correct diagnosis of estrus is important and the exact time of ovulation can be determined by variouse methods. Vaginal cytology has commonly used in conjunction with the physical examination, clinical history, vaginoscopy, and hormonal assays to determine the stage of the reproductive cycle. This study was therefore investigated the effectiveness of direct ovulation detector designed by changes of electrical resistance in vaginal mucus following different estrus cycles with several methods; vaginal cytology, concentration of plasma estrogen and progesterone, and direct examination by laparotomy. A total of 12 bitches was selected for the study and observed estrus signs. The bitches were evaluated clinical sign (vulvar swelling and bleeding), cytological examination (keratocyte and RBC), electrical resistance, plasma estrogen and progesterone concentration for estrus assessment. Accuracy of ovulation detection by vaginal cytology was significantly (p<0.05) lower than those by electrical resistance and plasma progesterone concentration, based on the confirmation by laparotomy. Vaginal smear is not confidential method compared to detection of electrical resistance and plasma progesterone concentration at ovulation. Although the value of electrical resistance was varied at the same points of estrus in individuals, ovulation was occurred at the first day which shown the peak of electrical resistance and mating time was third day after peak. In conclusion, ovulation detector designed by changes of electrical resistance is an effective and economic instrument for predicting estrus and ovulation in bitches.