• Title/Summary/Keyword: Direct instrument method

Search Result 56, Processing Time 0.021 seconds

A Comparative Study on Direct Instrument Methods in Open Channel for Measuring River Water Usage (하천수 사용량 계측을 위한 개수로에서의 직접 계측방법 비교 연구)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.4
    • /
    • pp.65-74
    • /
    • 2020
  • Continuous and accurate instrument of river water usage is needed for sustainable river water management. Although the instrument methods applicable to each point of use of river water are different, more precise direct instrument methods are required at the point of major open channel. Users of river water should select appropriate direct instrument methods to measure usage, but there is a lack of standards and verification research. In this study, the H-Q rating curve method, ultrasonic method, and microwave method were applied directly to the test basin in the upper basin of Mangyeong river, and the accuracy of measurement data was evaluated by comparing absolute error between discharge data calculated by instrument method. When comparing the calculated discharge of point units, the ultrasonic method showed the best results of the actual measurement. Through continuous instrument, the sum of the daily and monthly units was compared, and the ultrasonic and microwave methods were shown to be highly accurate. Based on the results of this study, it is hoped that the appropriate direct measurement method can be selected according to the importance of the river water use facility, considering that the ultrasonic method and the microwave method are relatively costly compared to the water level-flow relationship method.

Identification of Closed Loop System by Subspace Method (부분공간법에 의한 페루프 시스템의 동정)

  • Lee, Dong-Cheol;Bae, Jong-Il;Hong, Soon-Il;Kim, Jong-Kyung;Jo, Bong-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2143-2145
    • /
    • 2003
  • In the linear system identification using the discrete time constant coefficients, there is a subspace method based on 4SID recently much suggested instead of the parametric method like as the maximum likelihood method. The subspace method is not related with the impulse response and difference equation in its input-output equation, but with the system matrix of the direct state space model from the input-output data. The subspace method is a very useful tool to adopt in the multivariable system identification, but it has a shortage unable to adopt in the closed-loop system identification. In this paper, we are suggested the methods to get rid of the shortage of the subspace method in the closed-loop system identification. The subspace method is used in the estimate of the output prediction values from the estimating of the state space vector. And we have compared the results with the outputs of the recursive least square method in the numerical simulation.

  • PDF

Feasibility Study of Laser Contact Angle Measurement for Nano-fiber Characterization (나노섬유의 특성분석을 위한 레이저 접촉각 측정기의 효율성 연구)

  • 신경인;안선훈;김성훈
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.5
    • /
    • pp.554-559
    • /
    • 2003
  • A newly developed contact angle measurement instrument by laser beam projection allows for rapid and direct determination of contact angles. The instrument may have a possibility to characterize newly developed nano-fibers. When the laser beam impinges on an edge of an interface of liquid and solid, projected beam were split across and made two straight lines on a tangent screen. From the result, it could measure the contact angle directly by reading the angle between two split beams. The purpose of this study was to prove reliability and reproducibility of the contact angle measurement instrument by laser beam projection compare to the conventional one by microscope through the comparative experiment and questionnaire. Test samples were selected by consideration of hydrophilic and hydrophobic, such as nylon 6 and polypropylene, respectively. The laser contact angle measurement has accurate, fast and convenient method to measure contact angle, and it can be a unique method to characterize nano-fibers.

Modelling Method for Removing Measurement Uncertainty in Chip Impedance Characterization of UHF RFID Tag IC (UHF RFID 태그 칩의 임피던스 산출 불확실성 제거를 위한 모델링 방법)

  • Yang, Jeenmo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.12
    • /
    • pp.1228-1235
    • /
    • 2014
  • Input impedance of UHF RFID tag chip is needed to design a tag. In determining the chip impedance, direct measurement method is adopted commonly. In this paper, problems generated from fixtures that interface between tag chip and coaxial-oriented measurement instrument are investigated and the result of the problems is shown, when the direct measurement method is applied. As an alternative to the method, a modeling method is proposed and its validity and accuracy are shown.

Design of Digital Transmitter and Receiver Modules in ILS (항공 계기착륙 디지털 송수신 모듈 설계)

  • Choi, Jong-Ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.4
    • /
    • pp.264-271
    • /
    • 2011
  • ILS(Instrument Landing System) is the international standard system for approach and landing guidance. ILS was adopted by ICAO(International Civil Aviation Organization) in 1947 and is currently being used in commercial systems. To design the digital transmitter and receiver modules that can be mounted in the integrated ILS, we propose the digital design methods of digital double AM modulator and demodulator using FPGA chip, DDS(Direct Digital Synthesizer) for generation of sampling clock, demodulator of DDC(Digital Down Converter) structure, and spectrum analyzer using DSP chip. We demonstrate the efficiency of the proposed design method through experiments using developed transmitter and receiver modules. This system can be used as a high-performance commercial system.

Emergency Degree and Usage Frequency Analysis of Vehicle IP Composition Factors to Provide Safety Driving Environment (안전운전 환경 제공을 위한 자동차 IP 구성요소의 긴급도와 사용빈도 분석 -소비자 설문을 바탕으로-)

  • Paik, Seung-Youl;Park, Peom
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.193-197
    • /
    • 1999
  • By the report of KISCO, the 54.20% of total disaster and the 20.87% of death disaster was caused by unsafe position-control. However, it is possible to decrease this kind of disaster rate by designing the control device in the consideration of safety. One of the most popular control device is vehicle instrument panel. Therefore, not only basic function but safe control under the driving environments should be considered when the vehicle instrument panel is designed. For safe control at the driving time, it is especially important to determine the priority of each part using emergency degree and usage frequency, and to set them with this priority for easy control position. In this paper, developing method to determine the priority of each part by pair-wise comparison for emergency degree and usage frequency was suggested and generated the mutual order weights to give them orders. To apply this method to the parts of instrument panel such as function button, audio, air conditioner, and other several detail parts, the direct questionnaire was implemented to drivers about the emergency degree and usage frequency of each part.

  • PDF

A Study on the Escalation Method for Contract Adjustment Public Construction Project (물가변동에 따른 계약금액 조정방식의 지수조정율 산출에 관한 연구)

  • Bae Kyoung-Tae;Choi Dong-Soo;Hwang Chi Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.117-120
    • /
    • 2005
  • The business market of architecture has got a system that controls a deposit according to the price function. This system is written on a law of contract about countries. So the main body of construction has to make a reasonable contract. This study is written about a rate of numerical index on controling a deposit. We tried to fine problems and solutions of labor expenses, instrument costs and material costs which is so big and changable on the construction market Labor expenses are expressed according to the rate of construction scale between direct and indirect cost that applies ability of works. Instrument costs are expressed according to an output method of a unit price annually and a weight allowance of local instrument conditions and use frequence. The last material costs expressed according to a local weight allowance make a decision of the material cost index. They applies locally relative index more than absolute one on what uses the price rate of producers and importations. This solutions are not enough to apply to the real market, so it needs to exam and to be on the market after a feasibility study.

  • PDF

Acoustical characteristics of the Jing ; An experimental observation using planar acoustic holography

  • Kwon, Hyu-Sang;Kim, Yang-Hann;Minhong Rim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2E
    • /
    • pp.3-13
    • /
    • 1997
  • The Jing is a traditional Korean percussion instrument which plays a major role in Korean folk music. The distingishing feature of this instrument is its unique, long lasting low tone timbre. In this paper, we investigated the vibro-acoustic characteristics of the Jing. Our attention was focused mainly on findings out the physical variables that determine its unique sound. By understanding the way in which the Jing is manufactured, we were able to realize that the unique manufacturing and especially the tuning process by expert craftsman is responsible for the peculiar timbre the Jing produces. The experimental methods implemented to analyzer the Jing were planar acoustic holography and direct measurements by accelerometers. The results from the holographic method and the direct measurements were in good agreement. It turned out that unlike most percussion instruments which have inharmonic partials, the Jing has harmonic partials which are responsible for its unique low-tone timbre. From the holographic representations of the modes, it is clear that the antinodes are located in the center of the Jing which is coincident with the typical striking location. In addition, intensity maps were constructed so that the specific acoustic energy flow can be visualized. It was also interesting to see the the circulation of energy intensity which corresponds to the rotating mode of the Jing.

  • PDF

Criteria for clinical translucency evaluation of direct esthetic restorative materials

  • Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.3
    • /
    • pp.159-166
    • /
    • 2016
  • The purpose of this review was to suggest practical criteria for the clinical translucency evaluation of direct esthetic restorative materials, and to review the translucency with these criteria. For the evaluation of reported translucency values, measuring instrument and method, specimen thickness, background color, and illumination should be scrutinized. Translucency parameter (TP) of 15 to 19 could be regarded as the translucency of 1 mm thick human enamel. Visual perceptibility threshold for translucency difference in contrast ratio (${\Delta}CR$) of 0.07 could be transformed into ${\Delta}TP$ value of 2. Translucency differences between direct and indirect resin composites were perceivable (${\Delta}TP>2$). Universal and corresponding flowable resin composites did not show perceivable translucency differences in most products. Translucency differed significantly by the product within each shade group, and by the shade group within each product. Translucency of human enamel and perceptibility threshold for translucency difference may be used as criteria for the clinical evaluation of translucency of esthetic restorative materials.

ECG Measurement Method during Sleep with Array of Capacitive Electrodes Attached to Bed (침대에 부착된 용량성 전극 배열을 이용한 수면 중의 심전도 측정)

  • Lim, Y.G.;Kim, K.K.;Park, K.S.;Jeong, D.U.
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.521-524
    • /
    • 2005
  • In order to measure ECG in daily life, a new ECG measurement method on bed was developed. The provided method does not require any direct conductive contact between the instrument and bare skin, so that it does not cause the uncomfortable feel of touch and the possible skin trouble which are typical shortcomings of the conventional conductive contact ECG measurement. The provided method utilized an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet and laid on lower area of the mattress. A thin cotton bedcover covered the mattress, the electrodes, and the conductive textile and subjects lay on the mattress over the bedcover. ECG was obtained successfully. However its signal quality is lower and the motion artifact is larger than direct-contact measurement. Careful measurement setup was needed to reduce the motion artifact originated from variation in static electricity. From the ECG obtained by the provided method, R-peak could be discriminated easily and the information about the position and the posture of the subject could be obtained.

  • PDF