• Title/Summary/Keyword: Direct evaluation method

Search Result 605, Processing Time 0.028 seconds

Image Quality of Amorphous Selenium DR system using MTF measurement (MTF 측정을 통한 비정질 셀레늄 기반의 디지털 방사선 검출기의 영상 질 평가에 관한 연구)

  • Seok, Dae-Woo;Park, Ji-Koon;Choi, Jang-Yong;Nam, Sang-Hee;Kang, Shin-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.384-387
    • /
    • 2003
  • In this paper, the evaluation of image quality was performed for digital radiography which is developing in using amorphous selenium as a photoconductor material for the purpose of offering basic research data and measurement technique about Medical Imaging Quality. So Modulation Transfer Function as a main factor of imaging quality evaluation was investigated by slit method. For measurement of MTF, Nuclear associates. 07-624 Slit camera image was obtained to study the variation of MTF corresponding to changing spatial frequency. And Presampling MTF was estimated by slit camera image with $10\;{\mu}m$ width at Digital Radiography. In this study, the obtained data demonstrates that the clinical value of a direct conversion type digital radiation detector using the amorphous selenium, which is being developed by domestic technology.

  • PDF

An Evaluation Model on Supply Factors of Urban Park (도시공원의 공급인자 평가모형)

  • Chang, Byung-Moon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.1
    • /
    • pp.1-11
    • /
    • 2010
  • The purpose of this paper is to evaluate supply factors of urban parks to answer the research question: What are the causal effects of supply factors of urban parks on visitor satisfaction? After reviewing the literature and the Korean park planning process, we constructed a conceptual framework and have formulated the hypothesis of this research. We had obtained data through a questionnaire, which surveyed 452 visitors at 8 urban parks in Daegu Metropolitan City in 2008, based on a stratified sampling method. After the elimination of 96 unsuitable samples, we have analyzed the data using descriptive statistical methods, Pearson's correlation analysis and a path analysis method. We have found that: 1) While the direct and indirect effect of accessibility(ACC) on visitor satisfaction(VS) turned out to be 0.184 and 0.220, respectively, the indirect effect of information(IFM) and promotion(PRM) on VS turned out to be 0.101 and 0.177, respectively. 2) While the direct and indirect effect of service(SVR) on VS turned out to be 0.130 and 0.236, respectively, the direct effect of ACC turned out to be 0.698. 3) While the direct effect of ACC, SVR and attraction(ATT) on VS turned out to be 0.184, 0.130 and 0.698, respectively, composing 67.96% of causal effect, the indirect effect of ACC, IFM, PRM and SVR on VS turned out to be 0.220, 0.101, 0.177 and 0.236, respectively, composing 42.04% of causal effect. 4) The magnitude of causal effect of supply factors on VS turned out to be ATT(39.98%), ACC(23.14%), SVR(20.96%), PRM(10.14%) and IFM(5.78%) in order, and 5) the causal effect of external supply factors of ACC, IFM and PRM compose 39.06% of the causal effect while that of the internal supply factors of SVR and ATT is 69.94%. The research results suggest that: 1) Planning for park marketing strategy and remedial directions for existing urban parks, in order to increase visitor satisfaction, be focused on IFM and PRM, especially. 2) The research approach and path analysis method adopted by this research be valid and highly useful for planning and evaluation of other recreation areas. It is recommended that: 1) Structural Equation Model on supply factors of urban parks be established in the future. 2) Evaluation of supply factors by type of urban park be performed.

Uncertainty Evaluation of Josephson Voltage Standard in the level of $10^{-10}$ (10의 -10승 수준에서 조셉슨 전압표준기 불확도 평가)

  • Kim, K.T.;Kim, M.S.;Chong, Y.;Kim, W.S.;Song, W.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.56-61
    • /
    • 2007
  • The most recent improvement in the 10 V array system was carried out with focusing on noise reduction. We have evaluated the uncertainty of the 10 V Josephson array system after the improvement. The uncertainty evaluation of 10 V standard included a comparison with a programmable Josephson array system at 1 V. Every contribution to the measurement uncertainty was evaluated in the level of $10^{-10}$. The estimated combined uncertainty was found to be approximately $10^{-9}$ at 10 V, which was limited only by the indirect verifying method. In the near future, a direct comparison with another 10 V Josephson voltage standard is expected to be carried out to provide more accurate uncertainty evaluation for the KRISS Josephson voltage standard.

  • PDF

Investigation of Characteristics and Suggestion of Evaluation Formulae for Skin Resistance of SIP (SIP 말뚝의 주면저항력 특성 고찰 및 산정식 제안)

  • Lim, Hae-Sig;Park, Yong-Boo;Park, Jong-Bae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.2
    • /
    • pp.15-21
    • /
    • 2002
  • Because of the environmental problem during the pile driving, the use of low noise-vibration auger-drilled pilling is increasing to solve noise and vibration problem in pilling. In Korea, SIP (Soil-Cement Injected Precast Pile) method is mainly used as auger-drilled pilling. But, a proper bearing capacity evaluation formula has not been suggested, yet. To improve and supplement this situation, direct shear tests between SIP pile skin interface and soil were executed under various conditions. Through the analysis of test results, skin resistance characteristics of SIP were investigated thoroughly. Also, the maximum unit skin resistance capacity evaluation formulae on SM, SC soil was suggested.

  • PDF

Suggestion of Evaluation Formula for Skin Resistance of SIP (SIP말뚝의 주면저항력 예측 모델 제안)

  • Chung, Hyung-Sik;Lim, Hae-Sig;Kim, Jung-Soo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.1
    • /
    • pp.59-66
    • /
    • 2003
  • The environmental problem due to the pile driving, the use of low noise-vibration auger-drilled pilling is increasing to solve noise and vibration problem in pilling. Therefore, in Korea, SIP (Soil-Cement Injected Precast Pile) method is mainly used as auger-drilled pilling. However, a proper bearing capacity evaluation formula has not been suggested, yet. In order to improve and supplement this situation, direct shear tests between SIP pile skin interface and soil were executed under various conditions. Through the analysis of test results, skin resistance characteristics of SIP were investigated thoroughly. Also, the nonlinear unit skin resistance capacity model and relative parameters evaluation formula with SM, SC soil were suggested.

  • PDF

Cytotoxicity Evaluation of Elastomeric Impression Materials Using Different Fibroblasts Cell Lines

  • Kwon, Jae-Sung;Kim, Kyoung-Nam
    • Journal of Korean Dental Science
    • /
    • v.7 no.2
    • /
    • pp.80-86
    • /
    • 2014
  • Purpose: Current common method of cytotoxicity evaluation for elastomeric impression materials use animal based cell lines, which the clinical relevance has been often questioned. Hence, the purpose of this study was to examine the difference in results with both human based and animal based fibroblast cell line. Materials and Methods: Three types of fibroblast cells were used in this study; conventional mouse fibroblasts of L929, human gingival fibroblasts (HGF-1), and immortalized human oral fibrobalsts (hTERT-hNOF). Test on extract and test by direct contact using different commercially available elastomeric impression materials were carried out according to the international standards. Result: There was significant difference in cell viability between types of fibroblasts cell used, where HGF-1 showed highest cell viability and L929 the lowest. Conclusion: Within the limitation of this study, careful consideration must be given when selecting the cells and interpreting the results for cytotoxicity evaluation of elastomeric impression materials, where use of human based cell lines such as hTERT-hNOF would be appropriate for both ease of cytotoxicity test and clinical relevance.

Another View Point on the Performance Evaluation of an MC-DS-CDMA System

  • Chen, Joy Iong-Zong;Hsieh, Tai Wen
    • Journal of Communications and Networks
    • /
    • v.11 no.3
    • /
    • pp.240-247
    • /
    • 2009
  • The results of performance analysis by adopting the channel scenarios characterized as Weibull fading for an multicarrierdirect sequence-coded division multiple access (MC-DS-CDMA) system are proposed in this investigation. On the other hand, an approximate simple expression with the criterion of bit error rate (BER) versus signal-to-noise ratio (SNR) method is derived for an MC-DS-CDMA system combining with maximal ratio combining (MRC) diversity based on the moment generating function (MGF) formula of Weibull statistics, and it associates with an alternative expression of Gaussian Q-function. Besides, the other point of view on the BER performance evaluation of an MC-DS-CDMA system is not only the assumption of both single-user and multi-user cases applied, but the phenomena of partial band interference (PBI) is also included. Moreover, in order to validate the accuracy in the derived formulas, some of the system parameters, such as Weibull fading parameter (${\beta}$), user number (K), spreading chip number (N), branch number (L), and the PBI (JSR) values, etc., are compared with each other in the numerical results. To the best of author's knowledge, it is a brand new idea which proposes the evaluation of the system performance for an MC-DS-CDMA system over the point of view with Weibull fading channel.

A Simple and Efficient Method to Determine Rivaroxaban in Rat Plasma Using Liquid-Liquid Extraction and LC-MRM

  • Lee, Hyo Chun;Kim, Dong Yoon;Choi, Min-Jong;Jin, Sung Giu;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.10 no.2
    • /
    • pp.66-70
    • /
    • 2019
  • Rivaroxaban (RRN) is the first available active direct factor Xa inhibitor (anticoagulant) with oral administration. Due to its success in market, there have been efforts to develop various RRN formulations, and the development of good analytical methods for its in vivo evaluation is an essential prerequisite. Thus, here, a simple and efficient method to determine RRN in rat plasma using liquid-liquid extraction (LLE) and liquid chromatography and multiple reaction monitoring (LC-MRM) was presented. The use of ethyl acetate as the LLE solvent results appropriate extraction and purification of RRN and it also helps the significant reduction of rat plasma volume required for RRN quantitation. The developed method showed good analytical performance including specificity, linearity ($r^2{\geq}0.999$ within 0.5 - 500 ng/mL), sensitivity (the lower limit of quantitation at 0.5 ng/mL), accuracy (89.3 - 107.0%), precision (${\geq}12.7%$), and recovery (89.2 - 105.7%). Additionally, RRN in sample extracts showed good stability. Finally, the applicability of the validated method to the PK evaluation of RRN was confirmed after its oral administration to normal rats. The present method is the first analytical method employing LLE for the simple and efficient extraction and purification of RRN in rat plasma. Therefore, the present method can contribute to the development of new RRN formulations as well as to the monitoring of RRN in special clinical situations through its efficient determination in various samples with or without minor modification.

Railbed Evaluation by using In-situ Penetration Test (원위치 관입실험기를 활용한 철도 노반 평가)

  • Kim, Ju-Han;Park, Jung-Hee;Yoon, Hyung-Koo;Koh, Tae-Hoon;Lee, Jong-Sub
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.261-267
    • /
    • 2011
  • The test fit has commonly used for the evaluation of the railbed condition, and indirect methods by using the compressional wave are also studied. the direct evaluation method by penetration test has not been studied. For the measurement of in-situ cone tip resistance of the railbed with minimizing the disturbance of the upper railbed. the cone penetrometer with the helical type outer rod(CPH) was developed. The outer rod, which has helical screw, is penetrated through the gravel layer and provides the reaction force for cone penetration testing. the cone tip resistances are measured by the mini cone penetrometer, where diameter is 15mm. For the developing the mini cone, strain gauge installation, circuit configuration, penetration rates and calibration process are considered. For the easy penetration of the screw rod in the field, the reaction force stepping plate and guide column are arranged. The screw rod are penetrated through the gravel layer. And the mini cone was pushed into the subgrade railbed at the penetration rate of 1mm/sec. The penetration test shows that the cone tip resistance increases along the depth. In addition, the subgrade condition is evaluated. This study demonstrates that the CPH may be effectively used for the evaluation of subgrade method any damage of the gravel layer.

  • PDF

Performance Evaluation of a Selenium(a-Se) Based Prototype Digital Radiation Detector (비정질 셀레늄 기반 디지털 방사선 검출기의 성능 평가)

  • Park, Ji-Koon;Kang, Sang-Sik;Cho, Sung-Ho;Shin, Jung-Wook;Kim, So-Yeong;Son, Dae-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.300-305
    • /
    • 2007
  • In this study, we have studied the fabrication and the performance evaluation of digital radiation detector of the based on selenium (a-Se) prototype which is widely researched about recently. The detector was fabricated using amorphous selenium in the specification of active area size $7{\times}8.5"$, pixel pitch $139{\mu}m$, and 12 bit ADC. In order for the performance evaluation of the fabricated detector, we used radiation quality RQA 5 that is suggested by the International Electrotechnical Commission (IEC), and evaluated modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Concerning MTF measurement, we used slit camera (Nuclear Associates, Model : 07-624-2222), and evaluated in the slit method. Also so as to compare the performance evaluation on the detector fabricated in this study, we used Hologic Direct-Ray (DR-1000) and GE Revolution XQ/I system, and evaluated and compared in the same method MTF, NPS, and DQE which are image quality factors. And as a result, the MTF of each detector In Nyquist frequency were evaluated to be 58% (at 3.5 lp/mm) in the case of DR-1000 and 65% (at 2.5 lp/mm) in the case of XQ/I, and that for the detector fabricated in this study was evaluated to be 36% (at 3.51 lp/mm). Also in the case of DQE(0), the detector fabricated in this study, DR-1000 of Hologic company, and XQ/I system of GE company respectively were evaluated as 36%, 32%, and 50%.