• 제목/요약/키워드: Direct detection

검색결과 917건 처리시간 0.023초

Joint Probability Density Functions for Direct-Detection Optical Receivers

  • Lee, Jae Seung
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.124-128
    • /
    • 2014
  • We derive joint probability density functions (JPDFs) for two adjacent data from direct-detection optical receivers in dense wavelength-division multiplexing systems. We show that the decision using two data per bit can increase the receiver sensitivity compared with the conventional decision. Our JPDFs can be used for software-defined optical receivers enhancing the receiver sensitivities for intensity-modulated channels.

직접검파, 광통신에 이용되는 Point-detector Array의 해석 (Direct-Detection, Analysis of the point-detector arrays used in optical communication)

  • 성평식;김영권
    • 한국통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.428-438
    • /
    • 1987
  • 本 論文은 大氣 空間에서 信號場과 雜音場을 處理하기 위하여 point-detector array檢波 시스템을 構成한 것이다. 또 variance 및 covariance Circuit도 구성했다. 이것들을 이용하여 測定한 直接檢波 最大出力은 理論値와 잘 一致함을 確認하였고 또한 實驗値는 joint-Gaussian理論曲線과 一致하였다.

  • PDF

Detection of the Carcinogenic Liver Fluke Opisthorchis viverrini Using a Mini Parasep SF Faecal Parasite Concentrator

  • Kaewpitoon, Soraya J;Rujirakul, Ratana;Tongtawee, Taweesak;Matrakul, Likit;Panpimanmas, Sukij;Wakkuwattapong, Parichart;Loyd, Ryan A;Kaewpitoon, Natthawut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권1호
    • /
    • pp.373-376
    • /
    • 2016
  • The Mini Parasep SF fecal parasite concentrator (MPSFC) is a new modification of the closed concentration system, which can easily be adopted in any routine clinical pathology laboratory. Here we describe our experience with the system in diagnosing Opisthorchis viverrini. A total of 199 fecal samples was submitted for routine examination in the clinical pathology laboratory of Suranaree University of Technology hospital, Nakhon Ratchasima province, Thailand, during August to October 2015. Out of all samples examined, 10 (5.03%) were positive with intestinal parasites including O. viverrini (2.01%), followed by Strongyloided stercoralis (1.51%), Hookworm (0.5%), Taenia spp. (0.5%), and Entamoeba coli (0.5%). Regarding the distribution of intestinal parasites in relation to the methods used, and found that 4 samples (2.01%) were positive using the direct wet smear method while 10 (5.03%) were positive with the Mini Parasep SF method; the difference was statistically significant ($X^2$-test = 116.506, p-value =0.001). Mean time for processing using the Parasep system was 6.03 min/sample, the conventional direct wet smear method at 0.3 min/sample. Cost per test, conventional direct wet smear method costing less than the Parasep method at USD 0.74/sample versus USD 1.47/sample. This first report of O. viverrini detection using MPSFC indicates that Parasep concentration test is useful in the routine laboratory, increasing the yield of parasites as compared to direct microscopy, but with greater processing time and cost. Further comparisons between the Parasep concentration test and common methods for O. viverrini detection are required, particularly concerning use in epidemiological surveys.

Direct Stem Blot Immunoassay (DSBIA): A Rapid, Reliable and Economical Detection Technique Suitable for Testing Large Number of Barley Materials for Field Monitoring and Resistance Screening to Barley mild mosaic virus and Barley yellow mosaic virus

  • Jonson, Gilda;Park, Jong-Chul;Kim, Yang-Kil;Kim, Mi-Jung;Lee, Mi-Ja;Hyun, Jong-Nae;Kim, Jung-Gon
    • The Plant Pathology Journal
    • /
    • 제23권4호
    • /
    • pp.260-265
    • /
    • 2007
  • Testing a large number of samples from field monitoring and routine indexing is cumbersome and the available virus detection tools were labor intensive and expensive. To circumvent these problems we established tissue blot immunoassay (TBIA) method an alternative detection tool to detect Barley mild mosaic virus (BaMMV) and Barley yellow mosaic virus (BaYMV) infection in the field and greenhouse inoculated plants for monitoring and routine indexing applications, respectively. Initially, leaf and stem were tested to determine suitable plant tissue for direct blotting on nitrocellulose membrane. The dilutions of antibodies were optimized for more efficient and economical purposes. Results showed that stem tissue was more suitable for direct blotting for it had no background that interferes in the reaction. Therefore, this technique was referred as direct stem blot immunoassay or DSBIA, in this study. Re-used diluted (1:1000) antiserum and conjugate up to 3 times with the addition of half strength amount of concentrated antibodies was more effective in detecting the virus. The virus blotted on the nitrocellulose membrane from stem tissues kept at room temperature for 3 days were still detectable. The efficiency of DSBIA and RT-PCR in detecting BaMMV and BaYMV were relatively comparable. Results further proved that DSBIA is a rapid, reliable and economical detection method suitable for monitoring BaMMV and BaYMV infection in the field and practical method in indexing large scale of barley materials for virus resistance screening.

저전력, 저가격 무선통신을 위한 DSSS-FSK 신호의 동기 및 반동기 상관 검파 (Coherent and Semi-Coherent Correlation Detection of DSSS-FSK Signals for Low-Power/Low-Cost Wireless Communication)

  • 박형철
    • 대한전자공학회논문지TC
    • /
    • 제42권4호
    • /
    • pp.1-6
    • /
    • 2005
  • 본 논문에서는 송신기와 수신기의 구현에 있어서 많은 장점을 제공하는 직접 확산-주파수(DSSS-FSK) 변조를 제안한다. 주파수 변조를 사용하여, 직접 확산 통신에서도 주파수합성기(PLL)를 이용한 송신기의 구현이 가능하므로 저전력, 저가격이 가능하다. 또한, 반송과 인접 대역에 정보를 전송하지 않아서 직접변환방식 수신기(DCR)의 구현을 용이하게 한다 한편, DSSS-FSK 신호를 위한 최적 동기 검파와 반동기 상관 검파 구조를 제안하고 그 성능을 분석한다. 매우 큰 반송파 주파수오프셋에서도 우수한 비트오율성능을 가지기 위해서, 분할 반동기 상관 검파 구조를 제안하고 성능을 분석한다.

Electrical Recognition of Label-Free Oligonucleotides upon Streptavidin-Modified Electrode Surfaces

  • Park, Jong-Wan;Jung, Ho-Sub;Lee, Hea-Yeon;Kawai, Tomoji
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제10권6호
    • /
    • pp.505-509
    • /
    • 2005
  • For the purpose of developing a direct label-free electrochemical detection system, we have systematically investigated the electrochemical signatures of each step in the preparation procedure, from a bare gold electrode to the hybridization of label-free complementary DNA, for the streptavidin-modified electrode. For the purpose of this investigation, we obtained the following pertinent data; cyclic voltammogram measurements, electrochemical impedance spectra and square wave voltammogram measurements, in $Fe(CN)_6^{3-}/Fe(CN)_6^{4-}$ solution (which was utilized as the electron transfer redox mediator). The oligonucleotide molecules on the streptavidin-modified electrodes exhibited intrinsic redox activity in the ferrocyanide-mediated electrochemical measurements. Furthermore, the investigation of electrochemical electron transfer, according to the sequence of oligonucleotide molecules, was also undertaken. This work demonstrates that direct label-free oligonucleotide electrical recognition, based on biofunctional streptavidin-modified gold electrodes, could lead to the development of a new biosensor protocol for the expansion of rapid, cost-effective detection systems.

A new cell-direct quantitative PCR based method to monitor viable genetically modified Escherichia coli

  • Yang Qin;Bo Qu;Bumkyu Lee
    • 농업과학연구
    • /
    • 제49권4호
    • /
    • pp.795-807
    • /
    • 2022
  • The development and commercialization of industrial genetically modified (GM) organisms is actively progressing worldwide, highlighting an increased need for improved safety management protocols. We sought to establish an environmental monitoring method, using real-time polymerase chain reaction (PCR) and propidium monoazide (PMA) treatment to develop a quantitative detection protocol for living GM microorganisms. We developed a duplex TaqMan quantitative PCR (qPCR) assay to simultaneously detect the selectable antibiotic gene, ampicillin (AmpR), and the single-copy Escherichia coli taxon-specific gene, D-1-deoxyxylulose 5-phosphate synthase (dxs), using a direct cell suspension culture. We identified viable engineered E. coli cells by performing qPCR on PMA-treated cells. The theoretical cell density (true copy numbers) calculated from mean quantification cycle (Cq) values of PMA-qPCR showed a bias of 7.71% from the colony-forming unit (CFU), which was within ±25% of the acceptance criteria of the European Network of GMO Laboratories (ENGL). PMA-qPCR to detect AmpR and dxs was highly sensitive and was able to detect target genes from a 10,000-fold (10-4) diluted cell suspension, with a limit of detection at 95% confidence (LOD95%) of 134 viable E. coli cells. Compared to DNA-based qPCR methods, the cell suspension direct PMA-qPCR analysis provides reliable results and is a quick and accurate method to monitor living GM E. coli cells that can potentially be released into the environment.

450 Gbps Low-cost Intensity Modulation with Direct Detection (IM/DD) Wave Length Division Multiplexing (WDM-PON) for 5G Fronthaul

  • Kawan Faiq Ahmed;Asaad Mubdir Jassim Al-Hindawi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권12호
    • /
    • pp.3310-3329
    • /
    • 2023
  • This work designs an eighteen-channel bidirectional Intensity Modulation with Direct Detection (IM/DD) Wavelength Division Multiplexing-Passive Optical Network (WDM-PON) system. The proposed system meets the requirement of the ITU-T 5G fronthaul link suggested design in G-series Recommendations-Supplement 66. The newly designed system, with a 25Gb/s/λ data rate (450Gbps as a system capacity), has been tested and simulated using OptiSystem V.19 software. The system has been evaluated by the BER with respect to variable the optical span and CW laser power. Based on the ITU-T recommendations, the simulation results demonstrate that this system might be used as an F1 and as an Fx 5G fronthaul link for functional split choices starting from options 1 to 7a. These options are required under 25Gbps/λ for each upstream and downstream link direction. Furthermore, the proposed system utilized a bidirectional single-mode optical fiber within short optical spans of up to 10 km. The proposed system is characterized by a low-cost, simple, DSP-free and amplifier-free system with a reasonable system capacity.

MOSFET Rds(on) 온도-저항 특성을 이용한 과열보호회로 모델링 (Over-Temperature Protection Circuit Modeling Using MOSFET Rds(on) Temperature-Resistance Characteristics)

  • 최낙권;이상훈;김형우;김기현;서길수;김남균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.3019-3021
    • /
    • 2005
  • In this paper we suggest a novel temperature detection method utilized in direct over-temperature protection circuit modeling. The suggested model detects temperature variation using Rds(on) characteristics of MOSFET, while the conventional methods are using extra devices such as a temperature sensor or an over-temperature detection transistor. The temperature-dependant MOSFET model is implemented using Spice ABM(Spice Analog Behavior Model). The direct over-temperature protection circuit was designed including it. We verified effectiveness of the temperature dependant Rds(on) model characteristics and performance of the direct over-temperature protection circuit on PSpice simulation

  • PDF

Performance Comparison According to Image Generation Method in NIDS (Network Intrusion Detection System) using CNN

  • Sang Hyun, Kim
    • International journal of advanced smart convergence
    • /
    • 제12권2호
    • /
    • pp.67-75
    • /
    • 2023
  • Recently, many studies have been conducted on ways to utilize AI technology in NIDS (Network Intrusion Detection System). In particular, CNN-based NIDS generally shows excellent performance. CNN is basically a method of using correlation between pixels existing in an image. Therefore, the method of generating an image is very important in CNN. In this paper, the performance comparison of CNN-based NIDS according to the image generation method was performed. The image generation methods used in the experiment are a direct conversion method and a one-hot encoding based method. As a result of the experiment, the performance of NIDS was different depending on the image generation method. In particular, it was confirmed that the method combining the direct conversion method and the one-hot encoding based method proposed in this paper showed the best performance.