• 제목/요약/키워드: Direct cooling

검색결과 308건 처리시간 0.022초

Analysis of the Boron Concentration Behavior Using LTC code During Power Maneuvering

  • Kwon, Jong-Soo;Chi, Sung-Goo;Park, Hae-Yun;Park, Seong-Hoon;Lee, Gi-Won
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.413-418
    • /
    • 1996
  • The main purpose of this paper is to develop the modified LTC code for accurate analysis of the boron concentration behavior of all components in the Nuclear Steam Supply System (NSSS). This is achieved by adapting a multi-cell mad to the existing Long Term Cooling (LTC) code. To verify the modified LTC, the simulated results were compared with the actual test results measured during YGN 4 initial criticality test. It was shown that the simulated results of this modified LTC were in good agreement with the actual test results. Also, the boron concentration behavior analysis were performed using the modified LTC code for both direct and indirect dilution/boration nude using YGN 3,4 design data. This modified LTC code can provide a valuable information in predicting boron concentration behavior during power maneuvering such as startup operation, shutdown operation and load follow operation. It is expected that the modified LTC can be applied to both on-line and off-line mode using Plant Computer System(PCS).

  • PDF

Envi-Met.을 이용한 도심 대기경계층 내 확산장 변화 수치 모의 (Diffusion Simulation Using Envi-Met. in Urban Planetary Boundary Layer)

  • 최현정
    • 한국기후변화학회지
    • /
    • 제7권3호
    • /
    • pp.357-371
    • /
    • 2016
  • Buildings in the city acts as a cause of distorted wind direction, wind speed, causing the stagnation of the air flow. In the recent trend of climate change can not but consider the temperature rise of the urbanization. This study was aimed to analyze the thermal comfort of planetary boundary layer in different artificial constructions areas which has a direct impact on urban climate, and estimating the warming phenomena. Envi-met model was used to consider the urban structure associated with urban growth in order to precisely determine the impact of the building on the city weather condition. The analyzed values of thermal comfort index were temperature, wind speed, horizontal and vertical turbulent diffusivity. In particular, analysis of the PPD(Predicted Percentage of Dissatisfied) represents the human thermal comfort. In this study, by adjusting the arrangement and proportion of the top floor building in the urban it was found that the inflow of the fresh air and cooling can be derived low PPD. Vertical heat flux amount of the city caused by climate change was a factor to form a high potential temperature in the city and the accumulation of cold air does not appear near the surface. Based on this, to make the city effectively respond to climate change may require a long-term restructuring of urban spatial structure and density management.

폭방향 두께제어를 고려한 용탕직접 압연로울의 최적형상 설계기법 (Optimum Shape Design Techniques on Direct Roller of Molten Metal Considering Thickness Control of Width Direction)

  • 강충길;김영도;정영진
    • 한국정밀공학회지
    • /
    • 제14권12호
    • /
    • pp.73-85
    • /
    • 1997
  • The rolling force and roll deformation behavior in the twin roll type strip continuous casting process has been computed to estimate the thermal charcteristics of a caster roll. To calculation of rolling force, the relationship between flow stress and strain for a roll material and casting alloy are assumed as a function of strain-rate and temperature because mechanical properties of a casting materials depends on tempera- ture. The three dimensional thermal dlastic-plastic analysis of a cooling roll has also been carried out to obtain a roll stress and plastic strain distributions with the commercial finite element analysis package of ANSYS. Temperature fields data of caster roll which are provided by authors were used to estimated of roll deformation. Roll life considering thermal cycle is calculated by using thermal elastic-plastic analysis results. Roll life is proposed as a terms of a roll revolution in the caster roll with and without fine failure model on the roll surface. To obtain of plastic strain distributions of caster roll, thermomechan- ical properties of roll sleeve with a copper alloy is obtained by uniaxial tensile test for variation of temperature.

  • PDF

A Study on Ways to Improve the Smell of Pig Barn

  • Min-Jae JUNG;Su-Hye KIM;Young-Do KIM
    • 웰빙융합연구
    • /
    • 제6권2호
    • /
    • pp.9-13
    • /
    • 2023
  • Purpose: In this study, we would like to make a technical proposal to solve the odor problem in pig houses. Through this, we would like to suggest an effective way to reduce the odor generated in the pig house as a solution to civil complaints. Research design, data and methodology: Conduct direct visits to pig farms where many civil complaints about bad odor occur, and identify the problems of each farm. Identify elements related to odor control, such as structure, facility, equipment, odor management method, and ventilation type. Through this, the technology to be applied to reduce odor and the solution to the odor problem are presented. Results: The results of major improvements are as follows: 1. Improvement of the structure of the barn or composting shed to an airtight type 2. Improvement of the pig manure treatment structure using the slope inside the barn 3. Establishment of ventilation and cooling systems 4. Automation of the mist spray system. Conclusions: As a result, as practical measures, sealing of facilities using winch curtains, construction of air conditioning systems using negative pressure ventilation, and management systems using AIoT systems were presented. It is judged that this study can be helpful in determining the grievances caused by civil complaints of tenant livestock farms and the direction of facility improvement in the future.

플라즈몬 금속 산화물 나노입자를 활용한 차세대 전기변색 소자 개발 동향 (Recent Progress of Developing Next-Generation Electrochromic Windows from Plasmonic Metal Oxide Nanocrystals)

  • 나장한;김성빈;허성연
    • 한국전기전자재료학회논문지
    • /
    • 제37권1호
    • /
    • pp.1-10
    • /
    • 2024
  • Direct use of sunlight through the glass windows is an efficient way to reduce the energy consumption related to the heating, cooling, and lighting. Introduction of near-infrared modulating properties through colloidal doped metal oxide nanocrystals into the classical electrochromic materials accelerates the development of next-generation electrochromic devices. There has been a steady enhancement in the performance of electrochromic devices, necessitating a review of the recent progress in next-generation electrochromic devices employing doped metal oxide nanocrystals. This review provides an overview of the current developments in next-generation electrochromic smart windows utilizing colloidal doped metal oxide nanocrystals, with a focus on the key factors for achieving these advanced windows. Colloidal doped metal oxide nanocrystals are a crucial component in realizing and bringing to market the next generation of electrochromic windows, though further research and development are still required in this regard.

Effect of inlet throttling on thermohydraulic instability in a large scale water-based RCCS: An experimental study

  • Qiuping Lv;Matthew Jasica;Darius Lisowski;Zhiee Jhia Ooi;Rui Hu;Mitch Farmer
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.655-665
    • /
    • 2024
  • The objective of the present experimental study is to investigate the effect of inlet throttling on the thermohydraulic stability of a large scale water-based Reactor Cavity Cooling System (RCCS). The test was performed using the water-based Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne, which represented a ½ axial scale and 12.5° sector slice of the full scale Framatome 625 MWt SC-HTGR RCCS concept. A two-phase steady state was first established through direct condensate refill, followed by increased inlet throttling over 10 stages, corresponding to a loss coefficient K over the range of 0.05-653. With the inlet throttling gradually increased, the system experienced a unique transition process between stabilization and destabilization. Through a stability analysis, three instability mechanisms were identified in the present test, including a compound mechanism due to both natural circulation oscillations (NCOs) and density wave oscillations (DWOs), Type-II DWOs, and geysering.

Development of scaling approach based on experimental and CFD data for thermal stratification and mixing induced by steam injection through spargers

  • Xicheng Wang;Dmitry Grishchenko;Pavel Kudinov
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1052-1065
    • /
    • 2024
  • Advanced Pressurized Water Reactors (APWRs) and Boiling Water Reactors (BWRs) employ a suppression pool as a heat sink to prevent containment overpressure. Steam can be discharged into the pool through multi-hole spargers or blowdown pipes in both normal and accident conditions. Direct Contact Condensation (DCC) creates sources of momentum and heat. The competition between these two sources determines the development of thermal stratification or mixing of the pool. Thermal stratification is of safety concern as it reduces the cooling capability compared to a completely mixed pool condition. In this work we develop a scaling approach to prediction of the thermal stratification in a water pool induced by steam injection through spargers. Experimental data obtained from large-scale pool tests conducted in the PPOOLEX and PANDA facilities, as well as simulation results obtained using validated codes are used to develop the scaling. Two injection orientations, namely radial injection through multi-hole Sparger Head (SH) and vertical injection through Load Reduction Ring (LRR), are considered. We show that the erosion rate of the cold layer can be estimated using the Richardson number. In this work, scaling laws are proposed to estimate both the (i) transient erosion velocity and (ii) the stable position of the thermocline. These scaling laws are then implemented into a 1D model to simulate the thermal behavior of the pool during steam injection through the sparger.

Performance evaluation of an improved pool scrubbing system for thermally-induced steam generator tube rupture accident in OPR1000

  • Juhyeong Lee;Byeonghee Lee;Sung Joong Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1513-1525
    • /
    • 2024
  • An improved mitigation system for thermally-induced steam generator tube rupture accidents was introduced to prevent direct environmental release of fission products bypassing the containment in the OPR1000. This involves injecting bypassed steam into the containment, cooling, and decontaminating it using a water coolant tank. To evaluate its performance, a severe accident analysis was performed using the MELCOR 2.2 code for OPR1000. Simulation results show that the proposed system sufficiently prevented the release of radioactive nuclides (RNs) into the environment via containment injection. The pool scrubbing system effectively decontaminated the injected RN and consequently reduced the aerosol mass in the containment atmosphere. However, the decay heat of the collected RNs causes re-vaporization. To restrict the re-vaporization, an external water source was considered, where the decontamination performance was significantly improved, and the RNs were effectively isolated. However, due to the continuous evaporation of the feed water caused by decay heat, a substantial amount of steam is released into the containment. Despite the slight pressurization inside the containment by the injected and evaporated steam, the steam decreased the hydrogen mole fraction, thereby reducing the possibility of ignition.

층류 대향류장에 형성된 분무화염의 2차원 비정상 모델링 -당량비 및 연료종에 관한 영향- (2-Dimensional Unsteady Modeling of Spray Flame Formed in a Laminar Counterflow Field - Effects of Equivalence Ratio and Fuel -)

  • 황승민;정진도;서병민;김영우
    • 대한환경공학회지
    • /
    • 제31권10호
    • /
    • pp.933-940
    • /
    • 2009
  • 본 연구에서는 분무화염의 기초적인 물리현상을 해명하기 위하여 층류 대향류장에 형성된 분무 화염에 2차원 직접 수치계산(Direct numerical simulation, DNS)을 적용하여, 당량비 및 연료종이 분무화염 구조에 미치는 영향에 대하여 관찰하였다. 기상에 대해서는 질량 보존식, 운동량 보존식, 에너지 보존식을 오일리안(Eulerian) 법으로 계산하였으며, 액적에 대해서는 화염중의 모든 개개의 유적을 라그란지안(Lagrangian) 법으로 추적하였다. 액체 연료로는 n-데칸 ($C_{10}H_{22}$)과 n-헵탄($C_7H_{16}$)을 이용하였으며, 연소반응 모델에는 총괄반응식을 이용하였다. 당량비가 증가함에 따라 착화가 빠르며, 고온영역도 넓게 분포하고 있다. 그러나, 최대 온도치는 당량비가 증가함에 따라 한번 증가한 후 감소하는 경향을 나타내고 있다. 당량비가 클수록 최대 온도가 감소하는 것은 분무화염 내부의 군연소 거동에 의한 냉각효과 때문이라고 생각된다. 또한, n-헵탄은 n-데칸과 비교하여 증발속도가 빠르기 때문에 넓은 고온 영역을 형성하지만 최대 온도는 거의 같은 값을 나타내었다.

소각재 및 산업부산물을 이용한 직접 수성탄산화 반응 특성 (Characteristics of Direct Aqueous Carbonation Reaction Using Incinerated Ash and Industrial By-Products)

  • 박동규;한승만;최창식
    • 청정기술
    • /
    • 제30권2호
    • /
    • pp.113-122
    • /
    • 2024
  • 본 연구에서는 이산화탄소 자원화의 일환으로 실험실 규모의 직접 수성탄산화 반응기를 이용하여 소각재와 더불어 탈황 석고, 저급 생석회 및 제강슬래그 등 다양한 알칼리성 산업부산물 6종을 대상으로 이산화탄소 포집 특성을 고찰하였다. 각 시료별 용해 특성과 더불어 반응 전, 후 열중량 분석을 통해 주요 반응 구조를 확인할 수 있었고, 이를 통해 반응성 CaO 함량을 정의하였다. 실험 결과, 생석회의 포집 용량 및 효율은 각각 473 g/kg, 86.9%로 결정할 수 있었으며, 탈황석고 및 소각재 역시 각각 51.1 ~ 131.7 g/kg, 51.2 ~ 87.7% 수준으로 비교적 높게 평가할 수 있다. 이에 반해 제강슬래그의 경우 생성 및 후처리 조건의 영향으로 포집 효율은 10% 미만으로 나타났으며 탄산화 공정 적용을 위해 생산 조건에 따른 영향에 대한 최적화가 요구된다. 본 연구를 통해 소각재를 비롯하여 생석회 및 탈황석고의 이산화탄소 포집특성이 이산화탄소 포집 공정 적용에 적절한 수준으로 판단할 수 있었으며, 이산화탄소전환 탄산칼슘의 건설소재 등 자원화 기술 개발의 기초자료를 확보할 수 있었다.