• Title/Summary/Keyword: Direct contact

Search Result 996, Processing Time 0.028 seconds

A Simple Condensation Model on the Vapor Jets in Subcooled Water (과냉각수로 방출되는 증기제트의 응축모델)

  • Kim, Hwan-Yeol;Ha, Kwang-Soon;Bae, Yoon-Yeong;Park, Jong-Kyun;Choi, Sang-Min
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.240-245
    • /
    • 2001
  • Phenomena of direct contact condensation (DCC) heat transfer between steam and water are characterized by the transport of heat and mass through a moving steam/water interface. Application of the phenomena of DCC heat transfer to the engineering industries provides some advantageous features in the viewpoint of enhanced heat transfer. This study proposes a simple condensation model on the steam jets discharging into subcooled water from a single horizontal pipe for the prediction of the steam jet shapes. The analysis model was derived from the mass, momentum and energy equations as well as a thermal balance equation with condensing characteristics at the steam/water interface for the axi-symmetric coordinates. The extremely large heat transfer rate at the steam/water interface was reflected in the effective thermal conductivity estimated from the previous experimental results. The analysis results were compared with the experimental ones. The analysis model predicted that the steam jet shape (i. e. radius and length) was increasing as the steam mass flux and the pool temperature were increasing, which was similar in trend to that observed in the experiment.

  • PDF

Effects of stranded oils and dispersant clean-up on intertidal gastropods (유류오염과 유처리제를 이용한 전화작업이 조간대에 서식하는 고둥류에 미치는 영향)

  • 제종길;강성현
    • 한국해양학회지
    • /
    • v.26 no.4
    • /
    • pp.350-357
    • /
    • 1991
  • An experimental approach was applied to test the effects of stranded oils and dispersant cleanup on marine gastropods, Nodilittorina exigua, littorina brevicula and Purpura clavigera. They were exposed to Labuan crude, Dubai crude and Bunker C fuel oil. Direct oil contact caused death of gastropods within 96 hours. N. exigua and L. brevicula were more sensitive than P. clavigera at the exposure of Bunker C fuel oil. Toxic effects of Bunker C oil was slower than crude oils. direct contact to concentrated dispersant killed gastropods, while clean-up with diluted dispersant still gave severe damage. P. clavigera could escape from dispersed crude oil below 250 ppm. Oiling and dispersant clean-up may have severe effects on marine gastropods by rendering them washed out to sea.

  • PDF

Inorgainc fouling and it fouling reduction in direct contact membrane distillation process (직접 접촉식 막 증발공정에서 무기 막오염 특성 분석 및 저감방법)

  • Lee, Tae-Min;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.115-125
    • /
    • 2020
  • This study was aimed to examine inorganic fouling and fouling reduction method in direct contact membrane distillation(DCMD) process. Synthetic seawater of NaCl solution with CaCO3 and CaSO4 was used for this purpose. It was found in this study that both CaCO3 and CaSO4 precipitates formed at the membrane surface. More fouling was observed with CaSO4(anhydrite) and CaSO4·0.5H2O(bassanite) than CaSO4·2H2O(gypsum). CaCO3 and gypsum were detected at the membrane surface when concentrates of SWRO(seawater reverse osmosis) were treated by the DCMD process, while gypsum was found with MED(multi effect distillation) concentrates. Air backwash(inside to out) was found more effective in fouling reduction than air scouring.

Experimental Study on Inward Melting of Phase Change Material in Inclined Circular Tube (경사진 원통형 용기내에서 상변화 물질의 내향 용융에 관한 실험적 연구)

  • Yim, Chang-Soon;Son, Ha-Jin
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.48-58
    • /
    • 1992
  • In the present investigation, experimental analysis was performed to research heat transfer phenomena generated by means of conduction and natural convection at a succession of tube-inclimations relative to the vertical tube during inward melting process of a phase change material. The phase change material used in the experiments is 99 percent pure n-docosane paraffin($C_{22}H_{46}$). When the tube is vertical, the dominant mode of energy transfer between the tube wall and the melting interface is natural convection. On the other hand, when the tube is inclined to the vertical, the melting solid is brought into direct contact with the tube wall by the action of gravity. In the experimental results, direct contact gave rise to substantial enhancements in the amount of melted mass, relative to those for natural-convection-dominated melting.

  • PDF

A Study on the Polymer Lithography using Stereolithography (광조형법을 이용한 고분자 리소그래피에 관한 연구)

  • Jung Young Dae;Lee Hyun Seop;Son Jae Hyuk;Cho In Ho;Jeong Hae Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.1
    • /
    • pp.199-206
    • /
    • 2005
  • Mask manufacturing is a high COC and COO process in developing of semiconductor devices because of mask production tool with high resolution. Direct writing has been thought to be the one of the patterning method to cope with development or small-lot production of the device. This study consists two categories. One is the additional process of the direct and maskless patterning generation using SLA for easy and convenient application and the other is a removal process using wet-etching process. In this study, cured status of epoxy pattern is most important parameter because of the beer-lambert law according to the diffusion of UV light. In order to improve the contact force between patterns and substrate, prime process was performed and to remove the semi-cured resin which makes a bad effects to the pattern, spin cleaning process using TPM was also performed. At a removal process, contact force between photo-curable resin as an etching mask and Si wafer is important parameter.

Image Capturing of Dispersed Phases in DCHXs by Electric Tomography

  • Chun, Won-Gee;Kim, Min-Chan;Lee, Heon-Ju;Kang, Yong-Heack;Kwon, Hyok-Bo
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.2
    • /
    • pp.69-78
    • /
    • 2001
  • This paper introduces the physical phenomena involved in Direct Contact Heat Exchangers (DCHXs) and also investigates the possibility of applying of EIT(Electrical Impedance Tomography) technique for capturing the images of dispersed phases as they stream through a stagnant body of water. A number of cases are studied where two dimensional cross-sectional static images are given for fictitious and actual masses present in a column of water(saline solution). In most direct contact liquid-liquid heat exchangers, oil or hydrocarbon with a density different(lighter or heavier) from water is normally used as dispersed working fluid. The main difficulty that arises with this arrangement lies in the elucidation of complicated flow field where the dispersed phase fluid tends to change its shape and size constantly during its journey through the other phase(water). This paper presents a number of results with different types of dispersed phases that are immiscible with water. The EIT technique has been employed in this context to test its applicability in capturing the dynamic images of dispersed phases. It shows static images of dispersed phases where dynamic images could be obtained by simply extending the algorithms and strategies employed in the present analysis.

  • PDF

A CFD ANALYSIS FOR THERMAL MIXING IN A SUBCOOLED WATER UNDER TRANSIENT STEAM DISCHARGE CONDITIONS (과도상태 증기제트 방출시 과냉각수조 내의 열혼합 해석)

  • Kang H.S.;Kim Y.S.;Chun H.G.;Song C.H.
    • Journal of computational fluids engineering
    • /
    • v.11 no.2 s.33
    • /
    • pp.8-18
    • /
    • 2006
  • A CFD benchmark calculation for a steam blowdown test was performed for 30 seconds to develop the methodology of numerical analysis for the thermal mixing between steam and subcooled water. In the CFD analysis, the grid model simulating the sparger and the IRWST pool were developed by the axisymmetric condition and then the steam condensation phenomena by a direct contact was modelled by the so-called condensation region model. Thermal mixing phenomenon in the subcooled water tank was treated as an incompressible flow, a free surface flow between the air and the water, a turbulent flow, and a buoyancy flow. The comparison of the CFD results with the test data showed a good agreement as a whole, but a small temperature difference was locally found at some locations. The commercial CFD code of CFX4.4 together with the condensation region model can simulate the thermal mixing behavior reasonably well when a sufficient number of mesh distribution and a proper numerical method are adopted.

Family Pets as a Source of Microspoum canis Infection (Microspoum canis 감염원으로서의 애완동물)

  • Pal M.;Dahiya S.M.;Lee Changs-Woo
    • Journal of Veterinary Clinics
    • /
    • v.7 no.2
    • /
    • pp.521-525
    • /
    • 1990
  • The present investigation confirms the zoonotic significance of Microspoum canis infection in five patients who had direct contact with diseased dogs and cats. Typical ringworm type lesions were mainly encountered on the exposed areas of the body. M. canis was isolated from the cutaneous lesions of man ana infected pets ; and also directly demonstrated in skin materials. However, the fungus could neither be recovered from the non-contact group nor from the saprobic environment. The isolates from man, dog, and cat showed similar gross as well as microscopic morphology. Further genetic studies so indicated that all the human and animal isolates of M. canis were(-) mating type. It is believed that transmission of zoophilic dermatophytes from animal to man occurs more commonly with direct exposure. In addition, the epidemiology and preventive measures are also discussed.

  • PDF