• Title/Summary/Keyword: Direct burning

Search Result 62, Processing Time 0.025 seconds

Prediction of a research vessel manoeuvring using numerical PMM and free running tests

  • Tiwari, Kunal;Hariharan, K.;Rameesha, T.V.;Krishnankutty, P.
    • Ocean Systems Engineering
    • /
    • v.10 no.3
    • /
    • pp.333-357
    • /
    • 2020
  • International Maritime Organisation (IMO) regulations insist on reduced emission of CO2, noxious and other environmentally dangerous gases from ship, which are usually let out while burning fossil fuel for running its propulsive machinery. Contrallability of ship during sailing has a direct implication on its course keeping and changing ability, and tries to have an optimised routing. Bad coursekeeping ability of a ship may lead to frequent use of rudder and resulting changes in the ship's drift angle. Consequently, it increases vessels resistance and also may lead to longer path for its journey due to zigzag movements. These adverse effects on the ship journey obviously lead to the increase in fuel consumption and higher emission. Hence, IMO has made it mandatory to evaluate the manoeuvring qualities of a ship at the designed stage itself. In this paper a numerical horizontal planar motion mechanism is simulated in CFD environment and from the force history, the hydrodynamic derivatives appearing in the manoeuvring equation of motion of a ship are estimated. These derivatives along with propeller thrust and rudder effects are used to simulate different standard manoeuvres of the vessel and check its parameters against the IMO requirements. The present study also simulates these manoeuvres by using numerical free running model for the same ship. The results obtained from both these studies are presented and discussed here.

A Study on the Combustion Characteristics of Food Waste Using the Experimental Apparatus for Combustibility (소형 연소장치를 이용한 음식폐기물 연소 특성 연구)

  • Chae, JongSeong;Yang, SeungJae;Kim, SeokWan;Lee, JaeHee;Ohm, TaeIn
    • New & Renewable Energy
    • /
    • v.16 no.2
    • /
    • pp.47-53
    • /
    • 2020
  • The amount of food waste and its water content depends on both the season and region. In particular, the water content typically varies between 73.8 wt.% and 83.3 wt.%, depending on the proportion of vegetables. Current food waste drying technologies are capable of reducing the water content to less than 10 wt.%, while increasing the heating value. Ongoing studies aim to utilize dried food waste as fuel. Food waste can be used to produce solid refuse fuel (SRF) by mixing it with various solid fuels or other types of waste. The analysis of specimens is very important when considering the direct combustion of food waste or its co-firing with solid fuels. In this study, the weight reduction of specimens after burning them in a small combustor, and compared with the results of thermogravimetric analysis (TGA). The concentration of various chemicals was also measured to define the characteristics of waste generation. Performed proximate analysis, elemental analysis, TGA, combustion experiment, the heating value, and derivative thermogravimetry (DTG).

Development of Misfire Detection Using Spark-plug (스파크플러그를 이용한 실화감지에 관한 연구)

  • 채재우;이상만;정영식;최동천
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.27-37
    • /
    • 1997
  • Internal combustion engine is the main source of environmental pollutants and therefore better technology is required to reduce harmful elements from the exhaust gases all over the world. Especially, harmful elements from the exhaust gases are caused by incomplete combustion of mixture inside the engine cylinder and this abnormal combustion like misfire or partial burning is the direct cause of the air pollution and engine performance degradation. the object of this research is to detect abnormal combustion like misfire and to keep the engine performance in the optimal operating state. Development of a new system therefore could be applied to a real car. To realize this, the spark-plug in a conventional ignition system is used as a misfire detection sensor and breakdown voltage is analyzed. In this research, bias voltage(about 3kV) was applied to the electrodes of spark-plug and breakdown voltage signal is obtained. This breakdown voltage signal is analyzed and found that a combustion phenomena in engine cylinder has close relationship with harmonic coefficient K which was introduced in this research. Newly developed combustion diagnostic method( breakdown voltage signal analysis) from this research can be used for the combustion diagnostic and combustion control system in an real car.

  • PDF

Combustion of PMMA in Liquid Oxygen Flow

  • Mitsutani, Toru;Ro, Takaaki;Yuasa, Saburo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.180-185
    • /
    • 2004
  • Our previous study showed that although the hybrid rocket engine with swirling gaseous oxygen had high performance, a direct injection of LOX with swirl into the combustion chamber of the hybrid rocket engine lowered the performance of the engine, compared to that with gaseous oxygen. In order to clarify this reason, combustion tests of a small PMMA combustor with an inner port diameter of 2 mm were conducted in liquid oxygen flow by comparison with gaseous oxygen flow. Although the oxygen mass fluxes of LOX were about two orders of magnitude larger than those of gaseous oxygen, the fuel regression rate of LOX were remarkably smaller than those of gaseous oxygen. For both liquid and gaseous oxygen, diffusion flames in the port of the grain controlled the combustion process of PMMA in oxygen flow. These results may be explained by the fact that only small amount of LOX vaporized and consumed in the combustion with PMMA while flowing through the port due to relatively larger latent heat of injected liquid oxygen compared to the heat of release by combustion which depended on the burning surface area of PMMA.

  • PDF

Study on the Fire Suppression by Heat Transfer of Thermal Insulation Materials (건축물 외단열재의 열전달평가를 통한 화재 억제 방안 연구)

  • Ryu, Hwa Sung;Shin, Sang Hun;Song, sung young;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.277-278
    • /
    • 2018
  • Improvement of insulation performance of buildings is a major part. Adiabatic method The adiabatic method minimizes the heat loss of the building. External insulation uses insulation to prevent fire. Ambient air hazards are less prone to fire. When a fire occurs, a phenolic pattern is formed and bond strength with the wall increases. EPS insulation and phenol foam were used to compare external heat transfer and external heat transfer. The heat transfer properties of phenolic foam and styrofoam were evaluated as follows. In the mortar and styrofoam structure, the problem of styrofoam reaching the burning point occurred before the collapse of the mortar, and the phenol foam had a problem in that when the direct fire was continued on the phenol foam. The characteristics of continuous infiltration appeared. In the case of mortar and phenol foam + styrofoam, the heat penetrated into the interior due to the shrinkage due to the shrinkage of the carbon screen on the phenol foam. However, when reinforced with glass mesh on the outer surface, And to reduce infiltration.

  • PDF

Atmospheric Distribution of PCDD/F Concentrations in Gyeonggi-do, South Korea (경기도 내 대기 중 다이옥신 분포 특성에 관한 연구)

  • Heo, Jong-Won;Min, Yoon-Ki;Kim, Dong-Gi;Choi, Il-Woo;Kim, Jong-Soo;Song, Il-Seok;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.6
    • /
    • pp.548-561
    • /
    • 2015
  • Atmospheric concentrations of polychlorinated dibezo-p-dioxins and furans (PCDD/Fs) were investigated at urban-residential (Group I: Suwon, Guri and Goyang), industrial (Group II: Ansan, Siheung and Bucheon), urban-rural mixed (Group III: Yangju, Pocheon and Dongducheon) and rural regions (Group IV: Yangpyeong) in Gyeonggi-do from February 2012 to November 2012 quarterly. The concentrations of PCDD/Fs ranged from 0.018 to $0.109pgTEQm^{-3}$ in Group I (mean value: $0.061pgTEQm^{-3}$), 0.059 to $0.367pgTEQm^{-3}$ in Group II (mean value: $0.179pgTEQm^{-3}$), 0.072 to $0.836pgTEQm^{-3}$ in Group III (mean value: $0.334pgTEQm^{-3}$) and 0.014 to $0.066pgTEQm^{-3}$ in Group IV (mean value: $0.034pgTEQm^{-3}$), respectively. In spite of the less PCDD/F emission sources than Group II (industrial regions), the level of PCDD/Fs in urban-rural mixed area showed the highest values with high fluctuation. It's likely that the Group III was affected by fugitive emissions such like biomass burning and unregulated open burning. The mean contribution of particle phase to total PCDD/F concentration was above 83% because most of PCDD/F congeners were partitioned into particle phase. We evaluated their gas-to-particles equilibriums with the regression between the particle-gas partition coefficient, $K_P(m^3{\mu}g^{-1})$ and corresponding subcooled liquid vapor pressure ($P_L$). The logarithm-$K_P$ of PCDD/Fs was poorly correlated with $P_L$ at low ambient temperature (below $10^{\circ}C$) and the slope (m) values for log-log plots of the $K_P$ vs. $P_L$ was steeper in the Group 2 and Group 3 than residential area. It implies that the slope values were likely influenced by both the direct emission source of PCDD/Fs and ambient temperature.

The Effects of Burning on Composition and Productivity of Grasslands (초지의 구조 및 생산성에 미치는 산불의 영향)

  • 강상준
    • Journal of Plant Biology
    • /
    • v.14 no.3
    • /
    • pp.36-42
    • /
    • 1971
  • The effects of irregular burning of vegetation by man were studied in relation to composition and productivity in a non-agricultural montane grassland in the Chongsun area, Kangwon-Do, Korea. The floristic composition in all study area includes 38 species. Three of the stations are dominated by Arundinella hirta and one is dominated by Miscanthus sinensis. The standing crop of the first station, which was fired in early spring, 1970, was 358.7g/$m^2$ to 497.5g/$m^2$; that of the second station, fired in late 1969 was 351. 5g/$m^2$; the third station, fired sometime in 1968, had a standing crop of 314.5g/$m^2$ to 397.1/$m^2$; the fourth station, having had no recent fires, had a standing crop of 370.0g/$m^2$ to 448.0g/$m^2$. The daily productivity shows a maximum of 6.03g/$m^2$ in the first station, and a minimum of 0.85g/$m^2$ in the fourth station. The productivity of grassland in the study area is at a maximum during July and August because of much precipitation, and decreases rapidly in the months to follow. The productive structure of the first and fourth stations is shown in Fig. 2 and 3. At the first station the maximum height attained by the plants was 180cm. In the height range of 50cm to 100cm there was a maximum of assimilative organs (5.6g/0.25$m^2$$\times$10cm), while in the height range below 50cm there was a maximum of non-assimilative organs (13.0g/0.25$m^2$$\times$10cm). At the fourth station, which has not been fired recently, the maximum height reached by the plants was commonly below 100cm. The assimilative organs showed a maximum abundance in the height range of 40cm to 50cm (4.5g/0.25$m^2$$\times$10cm). while the non-assimilative organs showed their greated abundance in the height range below 10cm (6.0g/0.25$m^2$$\times$10cm). There was a direct relationship between daily productivity and organic matter, available phosphorous, exchangeable calcium and potassium. It appears that the nutrients provided by the ash created in the firing of the study can be an important factor in the productivity of these grasslands.

  • PDF

An Experimental Investigation of the Effect of Particle Size on the Combustion Characteristics of Pulverized Sub-Bituminous Coal with Low Calorific Value by Using an LFR System (LFR 장치를 이용한 입자 크기 변화에 따른 저열량 아역청 미분탄의 연소특성에 관한 실험적 연구)

  • Jeon, Chung-Hwan;Kim, Yong-Gyun;Kim, Jae-Dong;Kim, Gyu-Bo;Song, Ju-Hun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.259-267
    • /
    • 2010
  • In this study, the effect of particle size on the combustion characteristics of pulverized sub-bituminous coal was experimentally investigated. A laminar-flow-entrained reactor was designed and implemented to realize the desired heating ratio and temperature corresponding to the combustion atmosphere of a pulverized-coal-fueled furnace. The flame length and structure of burning particles according to different sizes were investigated. Coal combustion processes were clearly distinguished by direct visual observation of the flame structure. The onset point of volatile ignition is greatly affected by changes in the particle size, and the burning time of the volatiles is least affected by changes in the particle size. The length and instability of char flame also increase with the increase of the particle size. However, the char consumption rate within the residential time remains nearly constant.

The Study on Temperature Measurement for the Standardization of Moxibustion (구법(灸法)의 표준화를 위한 온도 측정 연구(硏究))

  • Kim, Yoon-Hong;Lee, Seung-Ho;Yeo, Su-Jung;Choe, Il-Hwan;Kim, Young-Kon;Lim, Sabina
    • Journal of Acupuncture Research
    • /
    • v.25 no.2
    • /
    • pp.129-138
    • /
    • 2008
  • Objectives : The moxibustion is the method in using the heat stimulation made of attached and burned a moxa or other herbal materials on a healing point or acupuncture point and the chemical stimulation of a resin made from burning them. We need to standardize the characteristics of moxa combustion in order to get more systematic and objective result in operation mechanism and effects and then get more clinical abilities in these fields. Methods : In this study, using of labview system on the moxibustion. 1. we studied relation the size of barley and jujube seed with the moxa cone's peak combustion temperature and then measured and compared the moxa cone's peak combustion temperature by tonification and sedation method. 2. we measured the peak combustion temperature of indirect moxibustion. Results & comclusions : 1. When we measured a direct moxibustion's combustion temperature, the jujube seed sized moxa cone's peak temperature was higher than the barley sized moxa cone's when it burned and the time to peak temperature of the barley sized moxa cone was shorter than the jujube seed sized moxa cone's. 2. When the direct moxibustion was burned by the tonification and sedation method, the sedation method's peak temperature was higher than the tonification method's, the tonification's time to peak temperature was shorter than the sedation method's. 3. When we measured the temperature of the moxa combustion in the kinds of sliced herbal materials, the peak temperature of indirect moxibustion with a ginger when it sliced a 1.3mm size and a 1.5mm size was degreed within $40^{\circ}C$ to $52^{\circ}C$ and the peak temperature of indirect moxibustion with a garlic when it sliced a 1.7mm size was degreed within $46^{\circ}C$ to $62^{\circ}C$.

  • PDF

A comparison of marginal fitness by dental alloys (치관 보철물 제작에 사용되는 치과용 금속의 변연 적합도 비교)

  • Kim, Nam-Joong;Hwang, Kyung-Sook;Park, Yong-Duk
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.29-40
    • /
    • 2003
  • This study was aimed to verify a comparison by dental alloys upon the marginal fitness of dental prosthesis. Firstly, we waxed up on 45 epoxy resin dies, pressed the margin with hands, and identified the marginal fitness with microscope. And we made a single direct spruing system type of sprue by 3 dental alloys - metal crown alloys, PFM crown alloys, and gold crown alloys - each 15, total 45 waxing up, adjusting W/P ratio and invested the cast ring. Then, we made the dental prosthesis using the electric casting machine. In these processes we followed the manufacturer's instructions, in order to maintain the other conditions from the inner and outer, which included investment and burning out. After we tried on the dental prosthesis on epoxy resin dies, we have got the means of marginal gap at 9 points with same distances, around the cervical line which was checked already, using microscope($\times$300). The results of this study were as follows : 1. Metal crown alloys showed 2.9% better in marginal fitness than PFM crown alloys, and the difference was not statistically significant(P=0.497). 2. Gold crown alloys showed 31.3% better in marginal fitness than Metal crown alloys, and the difference was statistically significant(P=0.004). 3. Gold crown alloys showed 32.4% better in marginal fitness than PFM crown alloys, and the difference was statistically significant(P=0.002). 4. We saw that Gold crown alloys was the best dental alloys in the marginal fitness among the three.(P=0.049).

  • PDF