• Title/Summary/Keyword: Direct Loss

Search Result 900, Processing Time 0.029 seconds

A Study of Barrier Insertion Loss Near a High Rise Building (고층 건물에 인접한 방음벽의 삽입손실에 관한 연구)

  • 진병주;김현실;김상렬
    • Journal of KSNVE
    • /
    • v.10 no.1
    • /
    • pp.49-56
    • /
    • 2000
  • In this paper performance of the noise barrier which is 53 m long and 6m high, and is located between the high rise apartment and road, is studied by using experimental and analytic method. The insertion loss is measured by using the direct method in accordance with the ISO code, while theoretical prediction is based on Muradali and Fyfe's method (Applied Acoustics, Vol. 53, 49~75, 1998). In addition to the diffraction at the top of the barrier, the waves are reflected infinite times between the building and the barrier, which is equivalent to replacing the building by the infinite series of the image receiver points. In two-dimensional study, the prediction of the insertion loss results in significantly overestimated values compared with the measurement. However three-dimensional analysis shows reasonable agreements, where traffic noise is assumed as incoherent line source and the length of the source is larger than that of the barrier.

  • PDF

DEVELOPMENT AND TESTS OF THE ALGORITHM FOR DIRECT DATA TRANSMISSION BETWEEN RVDB AND HUGE CAPACITY DATA SERVER (RVDB와 대용량 서버 간의 직접 데이터 전송 알고리즘 개발과 시험에 관한 연구)

  • Roh, Duk-Gyoo;Oh, Se-Jin;Yeom, Jae-Hwan;Jung, Dong-Kyu;Oh, Chung-Sik;Yun, Young-Joo;Kim, Hyo-Ryoung;Ozeki, Kensuke
    • Publications of The Korean Astronomical Society
    • /
    • v.29 no.3
    • /
    • pp.45-52
    • /
    • 2014
  • This paper describes the development of algorithm for direct data transmission between Raw VLBI Data Buffer (RVDB) and Huge Capacity Data Server (HCDS) operated in Korea-Japan Correlation Center (KJCC). The transmitted data is the VLBI observation data, which is recorded at each radio telescope site, and the data transmitting rate is varying from 1 Gbps, in usual case, upto 8 Gbps. The developed algorithm for data transmission enables the direct data transmission between RVDB and HCDS through 10 Gbps optical network using VLBI Data Interchange Format (VDIF). Proposed method adopts the conventional UDP/IP protocol, but in order to prevent the loss of data during data transmission, the packet error monitoring and data re-transmission functions are newly designed. The VDIF specification and VDIFCP (VDIF Control Protocol) are used for the direct data transmission between RVDB and HCDS. To validate the developed algorithm for data transmission, we conducted the data transmission from RVDB to HCDS, and compared to the transmitted data with the original data bit by bit. We confirmed that the transmitted data is identical to the original data without any loss and it has been recovered well even if there were some packet losses.

A Study on the Reduction of Entry Loss by Inner Structure in Square Hood in Industrial Ventilation System (산업환기시설에서 사각형 후드의 내부 설치에 의한 유입손실 감소에 관한 연구)

  • Bae, Hyun-Joo;Yang, Won-Ho;Kim, Jong-Oh;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.27-34
    • /
    • 2003
  • An objective of local exhaust hood design is to design the hood to operate as efficiently as possible. The greatest loss normally occurs at the entrance to the duct, due to the vena contracta in the throat of the duct. This can be accomplished by minimizing the loss that results from the vena contracta. There have been little studied to be cost-effective approach as installing simple instrument inside the throat of the hood. The aims of this paper were to minimize entry loss using inner square, and to measure the effect of inner square when installed inside hood throat. The results of this study were as follows; First, the magnitude of vena contracta could be considered as the difference between direct measured velocity and calculated velocity, which is from Bernoulli theory. In circle hood, calculated velocity and direct measured velocity were 10.7m/sec and 10.3n/sec, respectively. And the calculated velocity and direct measured velocity in square hood were 7.7m./sec and 6.5m/sec, respectively. Second, effect of inner square by width was carried out. The widths of inner square were L/1(18cm), L/2(9cm), L/3(6cm) and L/6(3cm). In case inner square was installed with 3cm width, the entry of coefficient was 0.93, comparing with 0.85 of entry of coefficient of general hood. Third, effect of inner square by distance from hood inside surface to inner square was carried out. The distances were L/3(6cm), L/6(3cm), L/9(2cm) and L/l8(1cm). In case the distance was 3cm the best efficiency was shown (Ce= 0.93). Fourth, effect of inner square by location from hood entry to duct inside was carried out. The locations of inner square were entry(0cm), L/6(3cm), L/3(6cm), L/2(9cm) and L/l(12cm). In case the location was 0cm, 3cm and 6cm the entry of coefficients were 0.93, 0.92 and 0.90, respectively.

Dissociation of the Phenylarsane Molecular Ion: A Theoretical Study

  • Kim, Sun-Young;Choe, Joong-Chul
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.9
    • /
    • pp.2588-2592
    • /
    • 2010
  • The potential energy surfaces (PESs) for the primary and secondary dissociations of the phenylarsane molecular ion (1a) were determined from the quantum chemical calculations using the G3(MP2)//B3LYP method. Several pathways for the loss of $H{\cdot}$ were determined and occurred though rearrangements as well as through direct bond cleavages. The kinetic analysis based on the PES for the primary dissociation showed that the loss of $H_2$ was more favored than the loss of $H{\cdot}$, but the $H{\cdot}$. loss competed with the $H_2$ loss at high energies. The bicyclic isomer, 7-arsa-norcaradiene radical cation, was formed through the 1,2 shift of an $\alpha$-H of 1a and played an important role as an intermediate for the further rearrangements in the loss of $H{\cdot}$ and the losses of $As{\cdot}$ and AsH. The reaction pathways for the formation of the major products in the secondary dissociations of $[M-H]^+$ and $[M-H_2]^{+\cdot}$. were examined. The theoretical prediction explained the previous experimental results for the dissociation at high energies but not the dissociation at low energies.

Economic Generation Allocation with Power Equation Constraints (모선 전력방정식을 제약조건으로 하는 경제적 발전력 연산방법)

  • Eom, Jae-Seon;Kim, Geon-Jung;Lee, Sang-Jung;Choe, Jang-Heum
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.8
    • /
    • pp.398-402
    • /
    • 2002
  • The ELD computation has been based upon the so-called B-coefficient which uses a quadratic approximation of system loss as a function of generation output. Direct derivation of system loss sensitivity based on the Jacobian-based method was developed in early 1970s', which could eliminate the dependence upon the approximate loss formula. However, both the B-coefficient and the Jacobian-based method require a complicated Procedure for calculating the system loss sensitivity included in the constraints of the optimization problem. In this paper, an ELD formulation in which only the bus power equations are defined as the constraints has been introduced. Derivation of the partial derivatives of the system loss with respect to the generator output and calculation of the penalty factors for individual generators are not required anymore in proposed method. A comprehensive solution procedure including calculation of the Jacobians and Hessians of the formulation has been presented in detail. Proposed ELD formulation has been tested on a sample system and the simulation indicated a satisfactory result.

Analysis of Efficiency and Loss due to Number of Poles in Magnetic Gears (마그네틱 기어의 극수 변화에 따른 효율 및 손실 분석)

  • Kim, Seung-Hyun;Kim, Dong-Wook;Lee, Do-Yeop;Gim, Chan-Seung;Kim, Yong-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1023-1028
    • /
    • 2018
  • Mechanical gears driven by direct contact have problems including noise, vibration and heat. In order to, solve these problems, magnetic gears having a non-contact magnetic coupling have been proposed. Through various studies on magnetic gears, we found that losses are changed when the number of magnetic poles varies in the same gear ratio. For this reason, research team expect the iron loss of the magnetic gear and the Eddy current loss of the permanent magnet will have a certain tendency depending on the number of poles. This paper identified the magnetic gear's loss tendency according to the number of poles, and laid the basis for efficiency improvement design.

A Study on the Resilience-Based Performance Evaluation Method of Structures and Their Application Plan (구조물의 회복탄력성 기반 성능평가법에 대한 고찰 및 적용 방안에 관한 연구)

  • Kim, Yu-Seong;Kang, Joo-Won;Lee, Joon-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.159-167
    • /
    • 2020
  • The resilience performance evaluation method of a structure can evaluate the ability to recover after an earthquake disaster, and this study deals with the consideration and introduction of the resilience performance evaluation method. The resilience evaluation method can be expressed as a quantified number by constructing a loss estimation model and a recovery evaluation model. The recovery evaluation model should consider downtime in addition to the repair time, and the loss estimation model should consider not only direct loss to structures and non-structures, but also indirect loss due to functional loss of the building. In addition, to build a loss estimation model, the structure should be simplified to perform an efficient analysis. Therefore, in this study, the equivalent terminal induction system proposed cantilever-type and rahmen-type SDOF, and it is evaluated somewhat conservatively compared to the example structure, and it is judged that there is a need to improve the hysteresis characteristics by applying the stiffness reduction factor of the SDOF model.

Probabilistic earthquake risk consideration of existing precast industrial buildings through loss curves

  • Ali Yesilyurt;Seyhan O. Akcan;Oguzhan Cetindemir;A. Can Zulfikar
    • Geomechanics and Engineering
    • /
    • v.37 no.6
    • /
    • pp.565-576
    • /
    • 2024
  • In this study, the earthquake risk assessment of single-story RC precast buildings in Turkey was carried out using loss curves. In this regard, Kocaeli, a seismically active city in the Marmara region, and this building class, which is preferred intensively, were considered. Quality and period parameters were defined based on structural and geometric properties. Depending on these parameters, nine main sub-classes were defined to represent the building stock in the region. First, considering the mean fragility curves and four different central damage ratio models, vulnerability curves for each sub-class were computed as a function of spectral acceleration. Then, probabilistic seismic hazard analyses were performed for stiff and soft soil conditions for different earthquake probabilities of exceedance in 50 years. In the last step, 90 loss curves were derived based on vulnerability and hazard results. Within the scope of the study, the comparative parametric evaluations for three different earthquake intensity levels showed that the structural damage ratio values for nine sub-classes changed significantly. In addition, the quality parameter was found to be more effective on a structure's damage state than the period parameter. It is evident that since loss curves allow direct loss ratio calculation for any hazard level without needing seismic hazard and damage analysis, they are considered essential tools in rapid earthquake risk estimation and mitigation initiatives.

The Effect of Economic Liberalization on Foreign Direct Investment (경제자유화가 외국인직접투자 유치에 미치는 영향)

  • Kim, Nam-Su
    • Asia-Pacific Journal of Business
    • /
    • v.12 no.4
    • /
    • pp.289-297
    • /
    • 2021
  • Purpose - This study analyzed the correlation between economic liberalization and foreign direct investment. The purpose of this study is to seek ways to attract foreign direct investment from developing countries. Design/methodology/approach - This study analysed with observations of 19 from 2000 to 2018 using a fixed effect model, a random effect model, and a two-way fixed effect model. Findings - First, it was found that economic liberalization had a positive effect on attracting foreign direct investment in the early stages of economic liberalization. Second, it was found that economic liberalization in the deepening stage of economic liberalization had a negative effect on attracting foreign direct investment. In general, it was found that the higher the level of economic liberalization in developing countries is not accompanied by innovative changes in the industrial structure, the higher the level of economic liberalization is likely to decrease the inducement of foreign direct investment due to negative factors such as an increase in labor costs. Overall, this study approved that Economic liberalization have a non-linear (inverted U-shape) relationship with the inflow of foreign direct investment. Research implications or Originality - First, this study attempted to expand the variables for the determinants of FDI by analyzing economic factors which is a determinent of FDI. Second, economic liberalization generally has a positive effect on foreign direct investment, but it proved that it does not have only positive effects as a factor of attracting foreign direct investment in developing countries. The advantage of low wages in ASEAN countries acts as a factor for foreign direct investment, but as the degree of economic liberalization increases, the environment such as government size, guarantee of property rights, international trade freedom, fiscal soundness, and regulations change positively. On the other hand, it can be suggested that if the industrial level is less, it may lead to a loss of comparative advantage and a decrease in investment.

Direct ECC Bypass Phenomena in the MIDAS Test Facility During LBLOCA Reflood Phase

  • B.J. Yun;T.S. Kwon;D.J. Euh;I.C. Chu;Park, W.M.;C.H. Song;Park, J.K.
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.421-432
    • /
    • 2002
  • As one of the advanced design features of the APR1400, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood phase of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, test results of direct ECC bypass performed in the steam-water test facility tailed MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) are presented. The test condition is determined, based on the preliminary analysis of TRAC code, by applying the ‘modified linear scaling method’with the l/4.93 length scale . From the tests, ECC direct bypass fraction, steam condensation rate and information on the flow distribution in the upper annulus downcomer region are obtained.