• 제목/요약/키워드: Direct Load Control

검색결과 290건 처리시간 0.038초

A New Approach to Direct Torque Control for Induction Motor Drive Using Amplitude and Angle of the Stator Flux Control

  • Kumsuwan, Yuttana;Premrudeepreechacharn, Suttichai;Toliyat, Hamid A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.79-87
    • /
    • 2008
  • This paper proposes the design and implementation of a direct torque controlled induction motor drive system. The method is based on control of decoupling between amplitude and angle of reference stator flux for determining reference stator voltage vector in generating PWM output voltage for induction motors. The objective is to reduce electromagnetic torque ripple and stator flux droop which result in a decrease in current distortion in steady state condition. In addition, the proposed technique provides simplicity of a control system. The direct torque control is based on the relationship between instantaneous slip angular frequency and rotor angular frequency in adjustment of the reference stator flux angle. The amplitude of the reference stator flux is always kept constant at rated value. Experimental results are illustrated in this paper confirming the capability of the proposed system in regards to such issues as torque and stator flux response, stator phase current distortion both in dynamic and steady state with load variation, and low speed operation.

직접토크제어에 의한 위치검출기 없는 릴럭턴스 동기전동기의 위치 제어시스템 (A High-Performance Position Sensorless Motion Control System of Reluctance Synchronous Motor with Direct Torque Control)

  • 김동희;김민회;김남훈;배원식
    • 전력전자학회논문지
    • /
    • 제7권5호
    • /
    • pp.427-436
    • /
    • 2002
  • 본 논문은 직접토크제어(Direct torque control, DTC)를 사용한 릴럭턴스 동기전동기(Reluctance synchronous motor, RSM)의 위치센서 없는 모션제어 시스템을 제안한다. 고성능 효율제어를 수행하는데 있어서 DTC를 이용한 릴럭턴스 전동기 드라이브는 고정자 쇄교자속의 포화와 부하전류에 따라 비선형적으로 변하는 인덕턴스로 인해 여러 가지 문제점들이 발생한다. 이러한 이유로 본 논문에서는 정확한 고정자 쇄교자속과 토크를 계산하기 위해서 자속관측기의 $L_d\;와\; L_q$값을 회전자 위치와 고정자 전류에 대해 보상하였으며, 빠른 토크 응답특성과 최적 효율특성을 얻기 위해서 기준자속을 부하에 따라 계산하였다. 제안된 알고리즘의 정당성을 확인하기 위해서 1.0[kW] 릴럭턴스 동기 전동기를 사용하여 $\pm$20[rpm]과 $\pm$1500[rpm]에서 실험을 수행하였고, 실험을 수행한 결과 저속영역과 고속영역 모두 우수한 동특성과 향상된 효율을 얻을 수 있었다.

압력예측기법과 직접순시토크제어기법을 통한 유압펌프용 SRM의 압력제어구동 (Pressure Control Drive of SRM for Hydraulic Pump with Pressure Predict Method and Direct Torque Control Method)

  • 석승훈;;이동희;안진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.163-165
    • /
    • 2007
  • Direct Instantaneous Pressure Control(DIPC) method of SRM using pressure predict method is presented in this paper. A hydraulic pump system has an inherent defect that its dynamic behavior causes by interaction between the sensor and hydraulic load. It will make sometimes the whole system become oscillatory and unstable. Proposed system integrates direct instantaneous torque control (DITC) and Smith predictor to improve dynamic performance and stabilization. The proposed hydraulic oil pump system is verified by computer simulation and experimental results.

  • PDF

The Consumer Rationality Assumption in Incentive Based Demand Response Program via Reduction Bidding

  • Babar, Muhammad;Imthias Ahamed, T.P.;Alammar, Essam A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.64-74
    • /
    • 2015
  • Because of the burgeoning demand of the energy, the countries are finding sustainable solutions for these emerging challenges. Demand Side Management is playing a significant role in managing the demand with an aim to support the electrical grid during the peak hours. However, advancement in controls and communication technologies, the aggregators are appearing as a third party entity in implementing demand response program. In this paper, a detailed mathematical framework is discussed in which the aggregator acts as an energy service provider between the utility and the consumers, and facilitate the consumers to actively participate in demand side management by introducing the new concept of demand reduction bidding (DRB) under constrained direct load control. Paper also presented an algorithm for the proposed framework and demonstrated the efficacy of the algorithm by considering few case studies and concluded with simulation results and discussions.

기동정지계획을 고려한 직접부하제어에 관한 연구 (Research of Direct Load Control Considering Unit Commitment)

  • 이범;김용하;김형중;문혁기;정현성;이영길;최상규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.220-222
    • /
    • 2001
  • This paper describes the optimizing method of direct load control (DLC) considering unit commitment which is based on dynamic programming. To consider the unit commitment on DLC, 3-Dimensional dynamic programming as a new unit commitment method is developed. And, this method is applied to DLC. As a result, optimization of operating schedule with DLC is possible. This method is applied to the test system, and usefulness of the method is verified.

  • PDF

Energy Payback을 고려한 직접부하제어의 경제성 분석 (A Study on Economic Analyse for Direct Load Control considering Energy Payback)

  • 김형중;김인수;김용하;이범;최상규;문정호;이형노
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.311-314
    • /
    • 2001
  • This paper describes the optimizing method of direct load control (DLC) considering unit commitment which is based on dynamic programming. To solve DLC problem considering unit commitment, 3-dimensional dynamic programming as a new unit commitment method is developed. And, energy payback is concerned for DLC. As a result, optimization of operating schedule with DLC is possible. This method is applied to the test system, and usefulness of the method is verified.

  • PDF

직접 구동용 BLDC 전동기의 정밀 Robust 위치제어 및 적응형 외란 관측기 연구 (A Study of Adaptive Load Torque Observer and Robust Precision Position Control of BLDD Motor)

  • 고종선;윤성구
    • 전력전자학회논문지
    • /
    • 제4권2호
    • /
    • pp.138-143
    • /
    • 1999
  • 본 논문에서는 직접 구동용 브러쉬 없는 직류 전동기(BLDD)에 있어서 외란에 강인한 위치 제어를 하기 위한 새로운 제어 방법으로 적응 제어형 외란 관측기를 제시하였다. 정밀 위치 제어를 위해서 Field-orientation 방법을 통해 선형화 하였다. BLDC 전동기는 뒤틈(backlash)이 없는 반면에 높은 가격과 비선형 특성에 의한 복잡한 제어기가 필요하다는 단점이 있다. 또한 외부 외란은 전동기의 축에 직접 영향을 미치고 있다. 이 외란은 영향을 줄이기 위해서 Lyapunov 안정성 이론을 이용하였다. 이 이론을 바탕으로 제안된 시스템의 안정성을 증명하였으며, 관측기에서 취한 값을 순간적으로 등가 전류로 계산하여 정궤환(feedforward)하여 보상하였다.

  • PDF

유전자 알고리즘과 콤플렉스법에 의한 직접구동형 서보밸브의 제어기 상수값 설계 (Controller Parameters Design of Direct Drive Servo Valve Using Genetic Algorithm and Complex Method)

  • 이성래
    • 대한기계학회논문집A
    • /
    • 제37권4호
    • /
    • pp.475-481
    • /
    • 2013
  • 직접구동형 서보밸브의 제어시스템은 비선형적이며 밸브스풀에 미치는 유체력의 영향은 매우 크고 부하압력의 크기에 좌우된다. 제어시스템의 설계요구조건을 만족시키기 위해, 제약직접탐색방법인 유전자 알고리즘과 콤플렉스법을 적절히 활용하여 진상-지상제어기 및 미분피드백제어기의 최적 상수값을 탐색하였다. 최적 제어기 상수값을 대입하여 제어시스템을 시뮬레이션한 결과 설계요구조건을 만족하였다.

주파수 변화에 따른 5상 농형 유도전동기의 정수 추정 (Parameters Estimation of Five-Phase Squirrel-Cage Induction Motor in Changing Variable Frequency)

  • 김민희
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.241-247
    • /
    • 2014
  • This paper propose a variable parameter estimations of five-phase squirrel-cage induction motor(IM) for speed control system. In order to high performance control of AC motor using a field oriented control(FOC) and direct torque control(DTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental of variable input power frequency. There are results of stator winding test, no-load test, locked-rotor test, variable actual load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004.

Sensorless Starting of Direct Drive Horizontal Axis Washing Machines

  • Dianov, Anton;Kim, Nam Su;Lim, Seung Moo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.148-154
    • /
    • 2014
  • This paper describes problems of the sensorless starting of horizontal axis washing machines with direct drive and suggests solution, which was experimentally verified. Horizontal axis washing machines have very difficult conditions for the drive starting, especially at full load. Inertia of the tub and water, torque from the laundry make load torque at starting higher than rated one and sometimes even higher than the maximum torque of the motor, which makes sensorless starting extremely challenging task. This paper suggests modified open-loop starting, where control system is closed shortly after beginning at low speed and rotates the drum until laundry restructuring. To ensure proper work of the sensorless algorithm at low speed additional measures for increasing of the estimation algorithm performance have been taken. These measures include special algorithm for the drive parameters estimation, which has been developed and verified by the experimental results.