• 제목/요약/키워드: Direct Load Control

검색결과 290건 처리시간 0.025초

직접부하제어시스템의 효율적인 제어절차 방안 연구 (A Study on Efficient Process of Direct Load Control)

  • 손학식;김형중;김인수;박종배;신중린;두석배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.642-644
    • /
    • 2004
  • DLC(Direct Load Control) program has been introduced and operated for the stabilization of power demand. DLC program takes effect in accordance with political judgment of government (operating reserve ratio etc), which is controlled by DLC system mechanism. So we would improve understanding of DLC program participant introducing about control procedure in detail and also propose direction of development about control system.

  • PDF

신경제어기를 이용한 직접구동모터의 속도제어 (Speed Control of a Direct Drive Motor Using a Neuro-Controller)

  • 조정호;이동욱;김영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1050-1052
    • /
    • 1996
  • This paper presents a neuro-control algorithm for the speed control of a direct drive motor without the knowledge of the dynamics of the motor and the characteristics of a nonlinear load. In the field of motor control, it is not possible to directly use the back-propagation method in order to train a network since the desired output of the network is not known. Hence, we propose an extended back-propagation algorithm to force the closed loop system to give desired results. Experimental results shown that the proposed neuro-controller can reduce the unknown load effects and have the good velocity tracking capabilities.

  • PDF

역기전력을 이용한 2MW급 가변속 풍력터빈용 영구자석 동기기의 센서리스 제어 (Sensorless Control Using the Back EMF of PM Generator for 2MW Variable Speed Wind Turbine)

  • 임지훈;오상근;송승호;이현영;권오정;장정익;이권희
    • 풍력에너지저널
    • /
    • 제2권2호
    • /
    • pp.54-60
    • /
    • 2011
  • A PMSG in variable speed wind turbine needs to know the position of rotor for vector control. Since the position sensor has the disadvantage in terms of cost, complexity of the system, a sensorless algorithm is needed. The sensorless strategy using the back EMF estimation is used for PMSG Wind Turbine. This algorithm is comparatively easy to implement than other strategies. This paper introduces the application of stable sensorless control for 2MW direct drive PMSG. In order to confirm the sensorless algorithm, the implementation is proceeded using 2MW direct drive PMSG from no-load condition to full-load condition. To drive 2MW PMSG artificially, 2MW PMSG connected PMSG through the mechanical coupling.

Demand Response Impact on Market Operator's Revenue and Load Profile of a Grid Connected with Wind Power Plants

  • Tahmasebi, Mehrdad;Pasupuleti, Jagadeesh
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.46-52
    • /
    • 2013
  • Economic properties of an integrated wind power plant (WPP) and the demand response (DR) programs in the sample electricity market are studied. Time of use (TOU) and direct load control (DLC) are two of the DR programs that are applied in the system. The influences of these methods and the incentive payments by market operator's (MOs) with variable elasticity are studied. It is observed that DR with TOU and DLC programs together yields better revenue and energy saving for MOs.

확률적 기법을 통한 직접부하제어의 제어지원금 산정 (Determination of Incentive Level of Direct Load Control using Probabilistic Technique with Variance Reduction Technique)

  • 정윤원;박종배;신중린
    • 에너지공학
    • /
    • 제14권1호
    • /
    • pp.46-53
    • /
    • 2005
  • 본 논문은 확률적 기법을 적용하여 직접부하제어의 적정한 지원금을 산정하는 새로운 방법론을 제안한다. 직접부하제어의 경제성 분석은 발전기의 고장정지 특성, 직접부하제어 자원의 차단용량 및 차단시간 등을 모두 고려해야 하기 때문에 현실적으로 불가능한 것으로 인식되었다. 따라서 기존의 연구에서는 시나리오 접근법을 사용하여 직접부하제어의 경제성 평가를 수행하였다. 본 논문에서는 몬테카를로 시뮬레이션을 적용하여 직접부하제어의 제어전력량을 확률적으로 추정하고 이를 기반으로 직접부하제어의 지원금을 산정하는 새로운 접근법을 개발하였다. 또한 시뮬레이션의 효율을 향상시키기 위하여 분산감소 기법을 적용하였다. 본 논문에서 제안한 방법론의 유용성을 보이기 위해 IEEE 24-모선 신뢰도 계통에 적용하여 사례연구를 수행하였다.

부하관리사업자의 비상시 부하제어량 배분 알고리즘 개발 (Development of the Load Curtailment Allocation Algorithm for Load Aggregator in Emergeney Demand Response)

  • 정구형;김진호;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.633-635
    • /
    • 2003
  • Electricity industries throughout the world are undergoing unprecedented changes. As a result, these changes lead to the separation of traditional integrated utilities and the introduction of competition in order that increase efficiency in electricity industry. Direct load control (DLC) system in competitive electricity market has a hierarchical interactive operation system, therefore, its control logic is also applied by bilateral interactive method that interchanges information related to interruptible load between operation hierarchies. Consequently, load curtailment allocation algorithm appropriate for new DLC system is required, and based on interchanged information, this algorithm should be implemented by most efficient way for each operation hierarchy. In this paper, we develop the load curtailment allocation algorithm in an emergency for new DLC system. Especially, the optimal algorithm for load aggregator (LA) that participates in competitive electricity market as a main operator for load management is developed.

  • PDF

고속전자밸브를 사용한 전기유압서보시스템의 위치제어에 관한 연구 (A Study on Position Control of an Electro-Hydraulic Servo System Using High Speed On-Off Valves)

  • 허준영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권3호
    • /
    • pp.369-378
    • /
    • 1999
  • This paper presents position control of an electro-hydraulic servo system whoch is operated by four 2-2way high speed on-off valves with either PWM PID control method or sliding mode control method, The advantages of using high speed on-off valves instead of electo-hydraulic servo valves or electro-hydraulic proportional valves are low price robustness for oil contamination and direct control without a D/A converter. The system consists of load cylinder inertia car potentiometer and external load cylinder. The experiments were carried out under several conditions and the results were compared. As a result the sliding mode method has shown good control performance and the robust and stable positioning of the elector-hydraulic servo system can be achieved accurately.

  • PDF

직접토크제어에 의한 리럭턴스 동기전동기의 고성능 제어시스템 (A High-Performance Control System of Reluctance Synchronous Motor with Direct Torque Control)

  • 김민회
    • 전기학회논문지P
    • /
    • 제51권2호
    • /
    • pp.68-76
    • /
    • 2002
  • This paper presents an implementation of high-dynamic performance control system of Reluctance Synchronous Motor (RSM) drives for an industrial servo system with direct torque control (DTC). The problems of DTC for high-dynamic performance and maximum efficiency RSM drives are the nonlinear variable flux and inductance due to a saturated stator linkage flux and nonlinear inductance curve with various load currents. The accurate estimation of the stator flux and torque are obtained using stator flux observer of which a saturated inductance Ld and Lq can be compensated by using the adapted neural network from measuring the modulus and angle of the stator current. To obtain fast torque response and maximum torque/current with varying load current, the reference command flux is ensured by imposing Ids=Iqs. This control strategy is proposed to fast response and optimal efficiency for RSM drive. In order to prove rightness of the suggested control algorithm, we have some actual experimental system using 6000 pulse/rev encoder at ${\pm}10$ and ${\pm}1500rpm$. The developed digitally high-performance control system are shown some good response characteristics of control results and high performance features using 1.0kW RSM of which has 2.57 Ld/Lq salient ratio.

함수제어 기법을 이용한 Buck 컨버터 제어 (Control of the Buck Converter using the Function Control Law)

  • 이성백;원영진;김태웅
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권6호
    • /
    • pp.81-89
    • /
    • 1997
  • In order to achieve the zero voltage regulation of the output voltage, the function control law will be used. In the previous function control law, only the proportional controller is used and the stability of the closed loop system was not analyzed. In this paper, for the realization of the control law, a new method to retrieve the low frequency component of the inductor voltage is proposed and analyzed. The large signal closed loop characteristics are alos analyzed to ensure the stable operation of the system disturbances. By using the function control law in the control system, the effect of the disturbance of the supply voltage is reduced in 93.3% for the direct dusty ration method. Also, in the effect of the disturbance of the load current, the output voltage has a logn recovery-time and is changed proportionally in the direct duty ratio method, but has stable in the function control law. Finally, the analysis shows that the disturbance of the output voltage being due to the supply voltage variation can be eliminated completely and the closed loop output voltage is insensitive to the disturbance of the load current. Therefore, it is proved that by using the function control law, the switching power supply with zero-voltage regulation output voltage can be realized.

  • PDF

신경회로망을 이용한 에어컨의 가변주기제어 방법론 개발 (Development of Variable Duty Cycle Control Method for Air Conditioner using Artificial Neural Networks)

  • 김형중;두석배;신중린;박종배
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권10호
    • /
    • pp.399-409
    • /
    • 2006
  • This paper presents a novel method for satisfying the thermal comfort of indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. Korea Electric Power Corporation (KEPCO) use the fixed duty cycle control method regardless of the indoor thermal environment. However, this method has disadvantages that energy saving depends on the set-point value of the Air-Conditioner and direct load control (DLC) has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. In this paper, the variable duty cycle control method is proposed in order to compensate the weakness of conventional fixed duty cycle control method and improve the satisfaction of residents and the reduction of peak demand. The proposed method estimates the predict mean vote (PMV) at the next step with predicted temperature and humidity using the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. To verify the effectiveness of the proposed variable duty cycle control method, the case study is performed using the historical data on Sep. 7th, 2001 acquired at a classroom in Seoul and the obtained results are compared with the fixed duty cycle control method.