• 제목/요약/키워드: Direct Heating

검색결과 326건 처리시간 0.023초

2 kW급 MCFC용 평편형 개질기 운전결과 (The Performance & Operation Analysis of a Plate Type Reformet for 2 kW Class MCFC Stack)

  • 서혜경;안교상;임희천;이상득
    • 한국수소및신에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.159-167
    • /
    • 2002
  • The operation results of the 2kW class plate type reformer, which has several advantages compared with the tubular burner type reformer, are analyzed. This plate type reformer is composed of six combustion chambers and five reforming chambers by turns. The methane conversion rate at 1.6 absolute pressure is about 84%, which is reasonably similar to theoretical value, 85.3%. Though the abrupt interruption was made just by the carbon deposition during heating the fuel line to combustion chambers around 200 hours operation, the overall steady state operation is more than 450 hours. These operation results show the verification of long run performance and the possibility of direct connection between plate reformer and fuel cell stack.

Dimethyl-ether (DME) 연료의 분무, 연소 및 배기 특성에 관한 실험 및 수치해석적 연구 (A Study on the Spray, Combustion, and Exhaust Emission Characteristics of Dimethyl-ether (DME) by Experiment and Numerical Analysis)

  • 박수한;김형준;이창식
    • 한국분무공학회지
    • /
    • 제15권1호
    • /
    • pp.31-37
    • /
    • 2010
  • The aim of this work is to investigate the spray and combustion characteristics of dimethyl-ether (DME) at various injection conditions. The spray characteristics such as spray tip penetration and spray cone angle were experimentally studied from the spray images which obtained from the spray visualization system. Combustion and emissions characteristics were numerically investigated by using KIVA-3V code coupled with Chemkin chemistry solver. From these results, it revealed that DME spray had a shorter spray tip penetration and wider spray cone angle than that of diesel spray due to the low density, low surface tension, and fast evaporation characteristics. At the constant heating value condition, DME fuel showed higher peak combustion pressure and earlier ignition timing, because of high cetane number and superior evaporation characteristics. In addition, the combustion of DME exhausted more $NO_x$ emission and lower HC emission due to the active combustion reaction in the combustion chamber. The result shows that DME had a little soot emission due to its molecular structure characteristics with no direct connection between carbons.

피부의 광반응 (Photoreactions of the Skin)

  • 배성수;박래준;김진상;권혁철
    • The Journal of Korean Physical Therapy
    • /
    • 제4권1호
    • /
    • pp.13-18
    • /
    • 1992
  • Most of the electromagnetic agents used in physical therapy rely for their effects on tissue heating and photoreaction of the body. Infrared and untraviolet light on the other hand, owns its place in medicine because it produces direct photochemial reaction when it interacts with the body. This study was carried out to investigate and review for photoreaction of the akin. The results were an follows. 1. The effects of the infrared are heat production, increasing metabolism, increasing circulation, vasodilatation and pigmentation. 2. Directed photoreactions are divided into acute reaction and chronic reaction, and the acute reaction makes pigmentation from $290\~320nm$ of ultraviolet ray. 3. Ultraviolet ray formated pigmentations, which are melanoblasts excited from ultraviolet ray and received chemical stimulation, that make melanin granule. 4. If exposured with long duration, at ultraviolet ray, it makes skin thickening and epithelioma. 5. Indirected photoreaction is made by existenced hypersensitivity of photoreaction or lack of photodefence structure. 6. The phototoxic reactions are synthesized by chemical reaction of excitement from ultraviolet ray also this time analysis, synthesis and polymerization from energy of a circumferenced substance. 7. Sunscreen substances are P-amino benzoic acid and oxidate titan.

  • PDF

NUMERICAL ANALYSIS OF A SO3 PACKED COLUMN DECOMPOSITION REACTOR WITH ALLOY RA 330 STRUCTURAL MATERIAL FOR NUCLEAR HYDROGEN PRODUCTION USING THE SULFUR- IODINE PROCESS

  • Choi, Jae-Hyuk;Tak, Nam-Il;Shin, Young-Joon;Kim, Chan-Soo;Lee, Ki-Young
    • Nuclear Engineering and Technology
    • /
    • 제41권10호
    • /
    • pp.1275-1284
    • /
    • 2009
  • A directly heated $SO_3$ decomposer for the sulfur-iodine and hybrid-sulfur processes has been introduced and analyzed using the computational fluid dynamics (CFD) code CFX 11. The use of a directly heated decomposition reactor in conjunction with a very high temperature reactor (VHTR) allows for higher decomposition reactor operating temperatures. However, the high temperatures and strongly corrosive operating conditions associated with $SO_3$ decomposition present challenges for the structural materials of decomposition reactors. In order to resolve these problems, we have designed a directly heated $SO_3$ decomposer using RA330 alloy as a structural material and have performed a CFD analysis of the design based on the finite rate chemistry model. The CFD results show the maximum temperature of the structural material could be maintained sufficiently below 1073 K, which is considered the target temperature for RA 330. The CFD simulations also indicated good performance in terms of $SO_3$ decomposition for the design parameters of the present study.

마이크로파 발열된 $V_2$$O_5$-PbO-$TeO_2$ 유리의 특성에 관한 연구 (The Study for the Characteristics of Microwave Coupled $V_2$$O_5$-PbO-$TeO_2$Glass System)

  • 박희찬;이상은;김병우;박성수
    • 한국세라믹학회지
    • /
    • 제38권5호
    • /
    • pp.438-445
    • /
    • 2001
  • 600 W의 마이크로파 출력 하에서 PbO, V$_2$O$_{5}$, TeO$_2$ 및 V$_2$O$_{5}$-PbO-TeO$_2$성분들의 마이크로파 발열 특성을 조사하였다. V$_2$O$_{5}$ 성분의 높은 마이크로파 흡수능에 기인하여 V$_2$O$_{5}$-PbO-TeO$_2$유리상 시편들은 마이크로파를 흡수하여 주어진 온도까지 직접 가열되었다. XRD, OM, SEM 및 고전압 발생 측정기를 통하여 재래식 열 및 마이크로파 공정에서 열처리된 시편들의 결정화 및 전기 전도도의 특성을 비교 조사하였다. PbV$_2$O$_{6}$ 및 Pb$_4$V$_2$O$_{9}$ 결정상들이 마이크로파 열처리된 시편에서는 존재하였다. 그러나, 재래식 열처리된 시편들에서는 존재하지 않는다는 것을 확인하였고, 재래식 열처리된 시편들에 비하여 마이크로파 열처리된 시편들의 전기 전도도 값이 상대적으로 높았다.

  • PDF

Antimutagenic Effects of Juices from the Peppers in Salmonella Assay System

  • Park, Kun-Young;Kweon, Young-Mi;Rhee, Sook-Hee
    • 한국식품영양과학회지
    • /
    • 제24권3호
    • /
    • pp.440-445
    • /
    • 1995
  • The antimutagenic effects of juices from green pepper(GP), red pepper leaf(RPL), red pepper(RP) and sweet pepper(SP) were examined by the Ames method using Salmonella typhimurium TA100. The juice supernatants of GP, RPL and RP showed antimutagenic activities against afltoxin B1(AFB1) in Salmonella typhimurium TA 100. The juice supermatants of GP and RPL also exhibited the inhibitory effects(p<0.05) to the mutagenicities induced by N-methyl-N'-nitro-N-nitrosoguanidine(MNNG) and 4-nitro-quinoline-1-oxide(4-NQO). The juice of RP showed antimutagenic activities against indirect mutagen of AFB1, however, the activity was reduced at higher concentration(5.0%), furthermore, as the adding concentration of sample increased to 5.0%, it exhibited slight comutagenicith on direct mutagen of MNNG. Theantimutagenic activities of GP and RPL juices were reduced significantly after heating at 100℃ for 20min, supposing that the antimutagenic compound(s) in the juices were heat labile.

  • PDF

10kW급 HVAC 시스템을 위한 Enhanced Interleaved PFC Boost 컨버터 형태의 650V IPM 개발 (Development of Enhanced Interleaved PFC Boost Converter typed 650V Intelligent Power Module for up to 10kW HVAC Systems)

  • 이기현;홍승현;김태현;정진용;권태성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.536-538
    • /
    • 2018
  • This paper introduces an enhanced interleaved (IL) PFC (Power Factor Correction) boost converter typed 650V Intelligent Power Module (IPM), which is fully optimized hybrid IGBT converter modules; Silicon (Si) IGBT and Silicon Carbide (SiC) diode, for up to 10kW HVAC (Heating, Ventilation, and Air Conditioning) systems. It utilizes newly developed $4^{th}$ Generation Field Stop (FS) trench IGBTs, $EXTREMEFAST^{TM}$ anti-paralleled diodes, SiC Junction Barrier Schottky (JBS) diodes, Bridge rectifiers, Multi-function LVIC, and Built-in thermistor provide good reliable characteristics for the entire system. This module also takes technical advantage of DBC (Direct Bonded Copper) substrate for the better thermal performance. It is shown that the Si IGBT/SiC diode hybrid IL PFC module can achieve excellent EMI performance and greatly enhance the power handling capability or switching frequency of various applications compared to the Si IGBT/Diode. This paper provides an overall description of the newly developed 650V/50A Hybrid SiC IL PFC IPM product.

  • PDF

$300{\mu}m$ 수평미세관내 R-410A의 비등열전달 특성 (Boiling Heat Transfer Characteristics of R-410A in $300{\mu}m$ Horizontal Smooth Microchannel)

  • 최광일;;;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.262-268
    • /
    • 2008
  • The present paper dealt with flow heat transfer characteristics of R-410A vaporization in horizontal smooth microchannel. The test sections were made of stainless steel tube with inner diameters of 300 mm and length of 300 mm. The refrigerant was supplied with mass flux range of 260-600 kg/$m^2s$ and applied under operating heat flux range of 5-20 kW/$m^2$ using a direct electric current heating method. The in let saturation temperature was set at $10^{\circ}C$ and vapor quality up to 1.0. The influences of mass flux, heat flux and inner tube diameter on local heat transfer coefficients were presented. Comparison with existing heat transfer coefficient correlations was performed. An improved heat transfer coefficient correlation for refrigerant vaporization in microchannel based on superposition model was developed with a mean deviation of 14.01%.

  • PDF

수평 microchannel의 $CO_2$ 비등열전달 (Boiling Heat Transfer Characteristics of $CO_2$ in Horizontal Smooth Microchannel)

  • 최광일;;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.241-246
    • /
    • 2007
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of $CO_2$. Heat transfer coefficients of the refrigerant flow inside horizontal smooth microchannel were obtained with inner tube diameter of 0.3mm and length of 300mm. The direct electric heating method was applied for supplying the heat uniformly to the refrigerant. The experiments were conducted with $CO_2$ purity of 99.99%, at saturation temperature of $10^{\circ}C$, mass flux ranges of $300{\sim}900\;kg/m^2s$, and heat flux ranges of $15{\sim}45\;kW/m^2$. While heat transfer coefficient increased with the increase of heat flux in the low quality region, the heat transfer coefficient decreased with the increase of quality in the high quality region. The heat transfer coefficients were compared with seven existing correlations with the Gungor-Winterton's(1986) correlation gave the best prediction. A new corelation to predict the two-phase flow heat transfer coefficient was developed based on the Chen(1966) correlation. The new correlation predicted the experimental data well with a mean deviation of 9.69% and average deviation of -3.03%.

  • PDF

진공관식 태양열 집열 튜브의 열성능 비교 분석 (A Comparative Analysis on the Thermal Performance of Solar Vacuum Collector Tubes)

  • 현준호;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.15-22
    • /
    • 2003
  • This study deals with the collection of solar energy and its storage in evacuated tubular collector systems for different types of header design, flow passage and heat transfer devices. In order to elicit the most efficient combination of header design, flow passage, heat transfer hardware and operating conditions, a series of tests were done for the four different types of solar collectors utilizing vacuum tubes. The systems studied here either has the evacuated collector tubes with a metal cap on one end or the all-glass evacuated solar collector tubes These evacuated tubular collectors are known to be more efficient than the flat-plate ones in both direct and diffuse solar radiation. Test results show that the system comprised of the all-glass evacuated tubes with U-shaped copper pipes inside outperforms the other configurations. Especially, a rolled copper sheet tightly placed along the inner surface of each inner tube enhances heat transfer between the heated collector surface and the water contained in the U-shaped copper pipe.