• Title/Summary/Keyword: Dipole Magnet

Search Result 24, Processing Time 0.025 seconds

Synthesis and Photoinduced Magnetic Properties of a Mn12 Single Molecule Magnet by the cis-trans Isomerism of Azobenzene

  • George, Sheby M.;Kim, Jin-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1143-1146
    • /
    • 2009
  • [$Mn_{12}O_{12}(azo-L)_{16}(H_2O)_4$] (1), a new Mn12 single molecule magnet containing a photochromic azobenzene ligand, has been successfully synthesized by substitution of acetate ligand of Mn12 with 6-[4-{4-hexyloxyphenyl( azo)}-phenoxy]hexanoic-1-acid. The reversible photoisomerization of the azobenzene group was confirmed by UV-visible absorption spectroscopy. The temperature and field dependence of dc susceptibility and the temperature and the frequency dependence of ac susceptibility were measured for the cis and the trans isomer of 1. The magnetization value of the cis isomer in dc measurement is higher than that of the trans isomer. The cis isomer of 1 has a slower relaxation because cis-trans photoisomerization of the azobenzene group in peripheral ligands induces changes in its structure and dipole moment.

Development of 7.5T Superconducting Wiggler for Pohang Light Source (포항방사광가속기용 중심자장7.5T를 초전도위글러 개발)

  • Bae, D.J.;Sohn, Y.U.;Yoon, Y.D.;Kim, D.E.;Seo, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.18-20
    • /
    • 1995
  • This paper describes a 7.5T magnetic flux density superconducting wiggler that minimize net angular deflection and displacement of an electron rotating along the orbit at storage ring in Pohang Light Source. It consist of dipole superconducting magnet,high uniformity flux distribution due to current source supply,cryostat,vacuum chamber,measurement system. In this paper magnet design procedure, manufacturing, experimental results are contained.

  • PDF

The Development of PLS-II Storage-ring Girder Systems at PAL (방사광 가속기 PLS-II 저장링 거더 시스템 개발)

  • Kim, Seungnam;Lee, Chaesun;Lee, Honggi;Kim, Kwangwoo;Nam, Sanghun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.690-697
    • /
    • 2013
  • The magnets and vacuum chambers, which are the main facilities of the Pohang light source are installed on the storage-ring girders. System safety and reliability should be taken into account for the precise operating of the main facilities, so vibration analysis is essential to do this. Static and seismic analyses were performed for the design of structure considering safety, and also frequency and response spectrum analyses were performed for the precise alignment. With these results, the effects of surrounding vibration were checked. This paper explains about the design and vibration analysis of girder systems.

Superconducting magnet system of in-flight separator for a heavy ion accelerator planned in Korea

  • Kim, J.W.;Kim, D.G.;Jo, H.C.;Choi, Y.S.;Kim, S.H.;Sim, K.D.;Sohn, M.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.28-31
    • /
    • 2015
  • An in-flight fragment separator, which aims to produce and study rare isotopes, consists of superferric quadrupole triplets and $30^{\circ}$ dipole magnets to focus and bend the beams for achromatic focusing and momentum dispersion, respectively. The separator is divided into pre and main stages, and we plan to use superconducting magnets employing high-Tc superconductor (HTS) coils in the pre-separator area, where radiation heating is high. The HTS coils will be cooled by cold He gas in 20-50 K, and in the other area, superferric magnets using low-temperature superconductor (LTS) will be used at 4 K. A few LTS coils were wound and successfully tested in a LHe dewar, and the design of cryostat has been optimized. Development of the HTS coils is ongoing in collaboration with a group at KERI. An HTS coil of racetrack shape was wound and tested in a $LN_2$ bath and in a dewar with cryocooler. No degradation on critical current due to coil winding was found.

Design and control of a permanent magnet spherical wheel motor

  • Park, Junbo;Kim, Minki;Jang, Hyun Gyu;Jung, Dong Yun;Park, Jong Moon
    • ETRI Journal
    • /
    • v.41 no.6
    • /
    • pp.838-849
    • /
    • 2019
  • We present a permanent magnet-based spherical wheel motor that can be used in omnidirectional mobility applications. The proposed motor consists of a ball-shaped rotor with a magnetic dipole and a hemispherical shell with circumferential air-core coils attached to the outer surface acting as a stator. Based on the rotational symmetry of the rotor poles and stator coils, we are able to model the rotor poles and stator coils as dipoles. A simple physical model constructed based on a torque model enables fast numerical simulations of motor dynamics. Based on these numerical simulations, we test various control schemes that enable constant-speed rotation along arbitrary axes with small rotational attitude error. Torque analysis reveals that the back electromotive force induced in the coils can be used to construct a control scheme that achieves the desired results. Numerical simulations of trajectories confirm that even without explicit methods for correcting the rotational attitude error, it is possible to drive the motor with a low attitude error (<5°) using the proposed control scheme.

Fabrication and Installation of the MPK-EPU Vacuum System

  • Hong, Man-Su;Gwon, Hyeok-Chae;Han, Hong-Sik;Kim, Chang-Gyun;Ha, Tae-Gyun;Kim, Jae-Yeong;Park, Jong-Do
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.148.1-148.1
    • /
    • 2014
  • 포항가속기연구소는 Dipole Magnet, Wiggler, Undulator 등 다양한 광원에서 발생되는 강한 방사광을 여러 연구에 이용하고 있다. Max-Planck POSTECH 분원용 타원편광 Undulator (이하, MPK-EPU)는 carbon의 흡수선을 포함하는 250 eV에서 시작하여, 1,500 eV~3,000 eV 에너지 영역의 방사광을 발생시켜 자성물질을 비롯한 다양한 이방성 물질의 연구를 수행하는데 활용할 예정이다. 현재, MPK-EPU용 진공용기의 기계가공, 화학세척, 용접 및 최종 초고진공 진공 달성을 위한 탈기체처리, NEG 활성화 작업등을 마무리하고 PLS-II 저장링 6A 구간에 설치 완료하였다. 이 논문에서는 MPK-EPU용 진공시스템의 제작 및 설치작업에 대한 전반적인 사항과 진공작업 및 그 결과를 발표하고자 한다.

  • PDF

A Study on the Oxygen Saturation Level Changes in the Blood Exposed to the Static Magnetic Field (자속에 노출된 인체의 혈중 산소 포화농도의 변화에 관한 연구)

  • Jung, Yong-Chul;Lee, Dong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.87-90
    • /
    • 2007
  • The effects of static magnetic field on the human biological system are becoming increasingly more important with the adaption of static magnet in the medical community. It is the goal of this paper to review the effects of static magnetic fields on oxygen saturation level in blood. The results of this paper show that the oxygen saturation level increased in the blood in index finger when the static magnetic dipole was fitted on index finger.

ADC In-vacuum Undulator Upgrade

  • Hong, Man-Su;Kim, Se-Hyeon;Gwon, Hyeok-Chae;Han, Hong-Sik;Ha, Tae-Gyun;Park, Jong-Do
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.116.1-116.1
    • /
    • 2013
  • 포항가속기연구소 저장링에는 Dipole Magnet, Wiggler, Undulator 등 다양한 방사광발생장치를 설치하여 각종 실험에 사용하고 있다. 그중 ADC사에서 제작한 In- vacuum Undulator (이하, ADC-IVU)는 고휘도의 X-선 빔을 생성하여 생체고분자(단백질, DNA 등) 단결정의 X-선 회절 데이터를 획득하는 실험을 수행한다. 현재, ADC-IVU의 Rf finger 등 일부장치의 성능개선을 위한 장치 해체, 교체 작업과 재조립 및 정렬작업, 구동시험을 거치고 최종 초고진공 진공 달성을 위한 탈가스처리, NEG 활성화작업등을 마무리 하였다. 본 발표에서는 ADC-IVU의 성능개선 작업에 대한 전반적인 사항과 진공작업 및 그 결과를 내용으로 한다.

  • PDF

The design and fabricationt for ion fraction measurement of plasma generator (플라즈마발생기의 이온분율 측정 장치 설계 및 제작)

  • Lee, Chan-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.368-368
    • /
    • 2008
  • Ion implantation has been widely developed during the past decades to become a standard industrial tool. To comply with the growing needs in ion implantation, innovative technology for the control of ion beam parameters is required. Beam current, beam profile, ion fractions are of great interest when uniformity of the implant is an issue. Especially, it is important to measure the spatial distribution of beam power and also the energy distribution of accelerated ions. This energy distribution is influenced by the proportion of mass for ion in the plasma generator(ion source) and by charge exchange and dissociation within the accelerator structure and also by possible collective effects in the neutralizer which may affect the energy and divergence of ions. Hydrogen atom has been the object of a good study to investigate the energy distribution. Hydrogen ion sources typically produce multi-momentum beams consisting of atomic ion ($H^+$) and molecular ion ($H_2^+$ and $H_3^+$). In the beam injector, the molecular ions pass through a charge-exchanges gas cell and break up into atomic with one-half (from $H_2^+$) or one-third (from $H_3^+$) according to their accelerated energy. Burrell et al. have observed the Doppler shifted lines from incident $H^+$, $H_2^+$, and $H_3^+$ using a Doppler shift spectroscopy. Several authors have measured the proportion of mass for hydrogen ion and deuterium using an ion source equipped with a magnetic dipole filter. We developed an ion implanter with 50-KeV and 20-mA ion source and 100-keV accelerator tube, aiming at commercial uses. In order to measure the proportion of mass for ions, we designed a filter system which can be used to measure the ion fraction in any type of ion source. The hydrogen and helium ion species compositions are used a filter system with the two magnets configurations.

  • PDF