• 제목/요약/키워드: Diode Rectifier

검색결과 291건 처리시간 0.025초

Novel Average Value Model for Faulty Three-Phase Diode Rectifier Bridges

  • Rahnama, Mehdi;Vahedi, Abolfazl;Alikhani, Arta Mohammad;Nahid-Mobarakeh, Babak;Takorabet, Noureddine
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.288-295
    • /
    • 2019
  • Rectifiers are widely used in industrial applications. Although detailed models of rectifiers are usually used to evaluate their performance, they are complex and time-consuming. Therefore, the Average Value Model (AVM) has been introduced to meet the demand for a simple and accurate model. This type of rectifier modeling can be used to simplify the simulations of large systems. The AVM of diode rectifiers has been an area of interest for many electrical engineers. However, healthy diode rectifiers are only considered for average value modeling. By contrast, faults occur frequently on diodes, which eventually cause the diodes to open-circuit. Therefore, it is essential to model bridge rectifiers under this faulty condition. Indeed, conventional AVMs are not appropriate or accurate for faulty rectifiers. In addition, they are significantly different in modeling. In this paper, a novel application of the parametric average value of a three-phase line-commutated rectifier is proposed in which one diode of the rectifier is considered open-circuited. In order to evaluate the proposed AVM, it is compared with experimental and simulation results for the application of a brushless synchronous generator field. The results clearly demonstrate the accuracy of the proposed model.

진동에너지 하베스팅을 위한 전파 정류기 성능 비교 (Performance Comparison of Full-Wave Rectifiers for Vibration-Energy Harvesting)

  • 윤은정;양민재;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.278-281
    • /
    • 2014
  • 본 논문에서는 진동에너지 하베스팅을 위한 세 가지 종류의 전파 정류기를 비교 분석 하였다. 첫번째 정류기는 두 개의 능동 다이오드(active diode)와 두 개의 MOSFET로 구성된 전파 정류기로 능동 다이오드의 비교기는 정류기의 출력으로부터 전력을 공급받는다. 두 번째는 네 개의 MOSFET로 구성된 정류기와 하나의 능동 다이오드로 구성된 2단 정류기이며, 마찬가지로 비교기는 정류기의 출력으로부터 전력을 공급받는다. 세 번째는 두 번째 정류기와 동일한 구조이나 비교기의 전력을 정류기의 입력으로부터 공급받는 input-powered 정류기이다. 이 정류기들을 0.35um CMOS 공정으로 설계하고 모의실험을 통해 성능을 비교, 분석하였다. 부하가 큰 경우에는 첫 번째 정류기를 이용하는 것이, 부하가 작은 경우에는 두 번째 정류기를 이용하는 것이 효율적인 측면에서 유리하다. 또한 효율보다는 진동에너지의 유무에 따른 전력 소모가 중요하다면 세 번째 정류기가 유리하다.

  • PDF

3상 다이오드 정류기의 Simulink 모델 (Simulink Model of 3-Phase Diode Rectifiers)

  • 이진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.514-519
    • /
    • 2001
  • Most of inverters adopt a diode rectifier as an input stage, which has very simple and rugged structure and therefore low cost. In order to properly design the 3-phase diode rectifier with an output smoothing capacitor and input inductors, it is necessary to fully simulate the system due to its nonlinear characteristics. Therefore this paper describes the operating behaviors including the current commutation in detail by using the proposed equivalent circuit, and also proposes the Simulink-based model of the system. The simulation results show the validity of the proposed model in all operating conditions.

  • PDF

A New 12-Pulse Diode Rectifier System With Low kVA Components For Clean Power Utility Interface

  • 이방섭
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.423-432
    • /
    • 1999
  • This paper proposes a 12­pulse diode rectifier system with low kVA components suitable for powering switch mode power supplies or ac/dc converter applications. The proposed 12-pulse system employs a polyphase transformer, a zero sequence blocking transformer (ZSBT) in the dc link, and an interphase transformer. Results produce near equal leakage inductance in series with each diode rectifier bridge ensuring equal current sharing and performance improvements, The utility input currents and the voltage across the ZSBT are analyzed the kVA rating of each component in the proposed system is computed. The 5th , 7th , 17th and 19th harmonics are eliminated in the input line currents resulting in clean input power. The dc link voltage magnitude generated by the proposed rectifier system is nearly identical to a conventional to a conventional 6-pulse system. The proposed system is suitable to retrofit applications as well as in new PWM drive systems. Simulation and experimental results from a 208V , 10kVA system are shown.

  • PDF

동기 정류기를 이용한 클램프 모드 포워드 다중 공진형 컨버터 (Clamp mode forward multi-resonant conveter with synchronous rectifier)

  • 안강순;김희준
    • 전자공학회논문지S
    • /
    • 제34S권2호
    • /
    • pp.112-120
    • /
    • 1997
  • The clamp mode (CM) forward zero voltage switching multi resonant converter (ZVS-MPC) with self-driven synchronous rectifier is studied. The loss at the synchronous rectification stage of the converter is analyzed using MOSFET piecewise linear model and is compared with the loss at the conventional schottky diode rectification stage of th econverter. From the results of the analysis, it is known that the use fo MOSFETs as a synchronous rectifier reduces the loss at the rectification stage overthe whole load range comparing the use of schottky diodes as a conventional rectifier in the converter. In order to verify the validit of the analysis, we have built a 33W(3.3V/10A) CM forward ZVS-MRC with self-driven synchronous rectifier, in which switching frequency is 1MHz, and tested. FRom the experimental results, it is known that the synchronous rectification achieved about 1W improvement in the loss at the rectification stage and about 3% in the efficiency at the converter as compared with the conventional schottky diode rectification.

  • PDF

역회복 현상을 고려한 전기자동차용 IPT 시스템의 Semi-Bridgeless 정류기 분석 (Analysis of Semi-Bridgeless Rectifier in Inductive Power Transfer Systems for Electric Vehicles Considering Reverse Recovery Phenomenon)

  • 손원진;안상준;변종은;이재한;이병국
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.327-333
    • /
    • 2019
  • This study analyzes the reverse recovery phenomenon of a semi-bridgeless rectifier (SBR) in an inductive power transfer (IPT) system for electric vehicles. Ideally, the reverse recovery phenomenon does not occur in a diode rectifier, however, in practical systems, the reverse recovery phenomenon occurs even when the SBR operates like a diode rectifier due to high operating frequency. Therefore, a practical analysis of operation modes for SBRs is presented in this study, considering the reverse recovery phenomenon, and the requirements for SBR switches are proposed. The analysis results are experimentally verified using a 3.3 [kW] IPT system prototype to which three different types of switches are applied.

PWM 정류기를 적용한 직류급전시스템의 전압강하 및 비용 평가 (Analysis on Voltage and Cost of Substation with PWM Rectifier in DC Traction Power Supply System)

  • 김주락;박기준;박창릉;추은상;이준영
    • 전기학회논문지
    • /
    • 제64권4호
    • /
    • pp.640-645
    • /
    • 2015
  • Near surface transit system has should be constructed as installation cost of light rail transit with elevated track. So, distance between two substations is longer than conventional system. The long feeding distance results in severe voltage drop. This paper proposes a PWM rectifier instead of diode rectifier. The PWM rectifier has some advantages. This is able to control output voltage constantly to reduce voltage drop and to use regeneration power without additional inverter. This paper analyse on improved voltage profile and cost of substation with PWM rectifier. The analysis of voltage profile use PSIM, and the installation cost of substation with PWM rectifier is compared to substation with diode rectifier.

새로운 영상전류 주입법에 의한 다이오드 정류기의 고조파 저감 (Harmonic Reduction of Diode Rectifiers by a New Zero-Sequence Current Injection Method)

  • 김현정;장민수;최세완;원충연;김규식
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.596-603
    • /
    • 2002
  • 본 논문에서는 영상고조파 주입법을 사용하여 3상 다이오드 정류기의 입력전류를 개선하는 새로운 방식의 고조파 저감기술을 제안한다. 3고조파 주입을 근간으로 하는 본 방식은 다이오드 정류기의 상측과 하측의 전류를 독립적으로 제어하기 위하여 두 대의 단상 반파 인버터와 두 대의 단상 변압기로 구성되어져 있다. 이렇게 만들어진 영상전류는 zigzag 변압기에 의해서 다이오드 정류기의 상측과 하측으로 주입이 되어진다. 이 결과 3상 다이오드 정류기의 입력전류는 순수한 정현파 전류가 된다. 본 방식의 타당성을 1.5kVA 시작품의 실험을 통하여 입증하였다.

커패시터 필터를 갖는 3상 다이오드 정류회로의 불평형전원에서의 입력전류 특성 (Input Current Characteristics of a Three-Phase Diode Rectifier with Capacitive Filter Under Line Voltage Unbalance Condition)

  • 이동기;박기원;정승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.569-575
    • /
    • 2001
  • The three-phase diode rectifier with capacitive Inter is highly sensitive to line voltage unbalance. Because of its inherent nonlinear characteristics small line voltage unbalance may cause highly unbalanced line current causing detrimental effects on power quality. This paper presents a theoretical basis on this 'unbalance amplification effect' and derives an analytical model of line current characteristics under unbalanced line voltage condition for various modes of operation. The results provide a basic and important guideline for optimal design of a three-phase diode rectifier with capacitive filter that is most commonly used for interfacing various power conversion equipments to power lines.

  • PDF

An Injection-Locked Based Voltage Boost-up Rectifier for Wireless RF Power Harvesting Applications

  • Lee, Ji-Hoon;Jung, Won-Jae;Park, Jun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2441-2446
    • /
    • 2018
  • This paper presents a radio frequency-to-direct current (RF-to-DC) converter for special RF power harvesting application at 915 MHz. The major featured components of the proposed RF-to-DC converter is the combination of a cross-coupled rectifier and an active diode: first, the cross-coupled rectifier boosts the input voltage to desired level, and an active diode blocks the reverse current, respectively. A prototype was implemented using $0.18{\mu}m$ CMOS technology, and the performance was proven from the fact that the targeted RF harvesting system's full-operation with higher power efficiency; even if the system's input power gets lower (e.g., from nominal 0 to min. -12 dBm), the proposed RF-to-DC converter constantly provides 1.47 V, which is exactly the voltage level to drive follow up system components like DC-to-DC converter and so on. And, maximum power conversion efficiency is 82 % calculated from the 0 dBm input power, 2.3 mA load current.